Volcano (Bono) Volcano VS 5t/10bar is identified in the source list as a composite boiler. It is normally installed in the engine room or funnel region and combines waste-heat recovery with an auxiliary firing arrangement within the overall boiler plant. Its purpose is to generate steam using engine exhaust heat when available and auxiliary fuel firing when additional or independent steam production is required. The source record provides the existing record note 'HFO/MDO'. The combination of exhaust-gas and fired heating sections means both burner condition and gas-side cleanliness affect plant performance. The exact model designation and any pressure, steam-output or fuel information contained in the source distinguish this unit from neighboring boiler variants; refer to approved manufacturer documentation for the exact figures.

Components & Design

Component data being added…

Technical Data

boiler type composite_boiler
steam capacity th 5
design pressure bar 10
fuel type HFO/MDO

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Burner ignition or flame failure caused by fuel, atomization or combustion-air problems, resulting in failed fired operation or burner trips
Soot fouling on exhaust-gas heating surfaces caused by engine operation, resulting in increased backpressure and reduced heat recovery
Tube or pressure-part leakage caused by corrosion, overheating or thermal fatigue, resulting in water loss or steam leakage
Feedwater or level-control malfunction caused by pump, valve, sensor or control faults, resulting in unstable water level or protective shutdown
Safety or combustion-control device malfunction caused by fouling, calibration drift or electrical faults, resulting in alarms, trips or unsafe indications

Service & Maintenance

Inspect burner or exhaust-gas sections as applicable, feedwater equipment, water-level controls, gauge glasses, safety devices and accessible pressure parts. Maintain boiler-water treatment and investigate abnormal level, pressure or temperature behavior before returning the unit to unattended service. Clean fireside or gas-side heating surfaces when fouling is indicated and inspect for soot accumulation, corrosion and leakage. Function-test alarms, trips, flame safeguards and automatic controls after maintenance. Examine refractory, casing and insulation where fitted for damage or hot spots. Refer to manufacturer, class and statutory documentation for exact pressure settings, water chemistry limits, inspection intervals and acceptance criteria.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

Replacement Parts

Keep burner service parts where fitted, ignition and flame-detection components, gaskets, gauge-glass consumables, feedwater-control parts and selected sensors recommended by the manufacturer. Pressure-part repair materials and safety-valve components must follow approved vessel and class procedures. Confirm exact spares from the boiler and burner documentation.