"> Alfa Laval Smit Smit Gas FU (Smit Combustion)
⚓ Working on this equipment?
Ask the AI troubleshooter, log your hours on board and turn them into invoice-ready service reports — for this exact model.
Start free — 14 days →
No credit card required
🔧 80 verified suppliers & service companies for Alfa Laval Smit in the Maritime Network Find suppliers →
Alfa Laval Smit

Smit Gas FU (Smit Combustion)

Alfa Laval Smit Smit Gas FU (Smit Combustion) — Oil Tanker, Chemical Tanker, Product Tanker.

Alfa Laval Smit Smit Gas FU (Smit Combustion)

Components & Design

Component data being added…

Technical Data

Capacity 1,000-20,000 m³/h
Pressure 0.15 or 0.25 bar(g)
Oxygen Content 2-4%
Type Low-pressure combustion-based
Burner Technology Ultramizing® steam-atomizing, soot-free
Cooling Seawater indirect cooling or Air-cooled (FU-type)

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Combustion Chamber Deterioration, Burner Erosion, Soot/Scale Buildup

Visual inspection of combustion chamber for corrosion, erosion, scale deposits, or soot; verify Ultramizing® burner nozzles for proper spray pattern and flame stability; check fuel oil atomization quality; minimum annual inspection, more frequent if operating in harsh marine conditions

Oxygen Analyzer Calibration Drift, Sensor Malfunction, False Readings

Calibrate oxygen analyzer per manufacturer schedule (typical: quarterly to semi-annually); verify actual oxygen levels match analyzer display; check for sensor contamination or fouling; ensure blow-back system (if equipped) functions properly; test analyzer accuracy across full range (0.5-4% O₂ depending on system type)

Scrubber Fouling, Demisters Blockage, Particulate Accumulation, Corrosion

Inspect scrubber nozzles, cooling pipes, floats, sensors and demisters for fouling or scaling; verify cooling spray system operates uniformly; check for salt crystal formation (especially in water evaporation zones); inspect for corrosion on contact surfaces (SUS 316 material); clean demisters and verify gas-liquid separation; recommended twice yearly or per manufacturer schedule

Dew Point Control Failure, Moisture Ingress (Critical for LNG/LPG Systems)

Monitor dew point readings continuously (target: below -45°C for LNG/LPG, dry saturated for flue gas systems); test cooler and chiller effectiveness; inspect dryer unit redundancy (LNG/LPG systems); verify salt-crystal-free spray system functionality; check condensate drain lines for blockage; perform annual dew point trending analysis

Seawater Cooling System Corrosion, Leakage, Blockage (FU/FIN Systems)

Inspect seawater inlet/outlet for scale or debris; check for leaks in combustion chamber cooling jackets (particularly FU-type where seawater cooling is used); evaluate biofouling in cooling pipes; consider FU-type air-cooled burner alternative if corrosion issues persist; verify pump/fan operation; half-yearly inspection recommended, full dry dock overhaul per IMO intervals (typically 5-10 years)

Type-general inspection and maintenance points for this equipment category — not model-specific.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →
Equipment Model #149252 · ✓ still in production