Skip to content
OceanSphereENGINES
Library › Inspection & safety data › Beams, frames, floors-op. damage
Inspection & safety data

Beams, frames, floors-op. damage

System: 02 - Structural Conditions · 788 findings in total, 8 of them with a detention (1.0 %).

What the data shows

Findings for this component on all vessels averaged 87 per year in 2022–2024, down 32.0 % from 128 per year in 2019–2021.

Only 15 findings for this component on foreign-flag vessels in 2019–2024: too few cases for a trend statement.

The latest year, 2025, only covers data up to 29 Nov 2025 and is not used in the trend.

Trend: average of 2022–2024 vs. 2019–2021; ±15 % counts as rising/falling; fewer than 30 cases: no statement.

Related deficiency codes

For components with a deficiency code, the yearly figures are on the code page.

Findings by year

US Coast Guard, inspections 2018–2025; “foreign flag” = findings on foreign-flag vessels.

Beams, frames, floors-op. damage20187520191512020121202111220228020237620241052025*68
YearFindingswith detentionShareforeign flag
20187522.7 %3
201915132.0 %6
202012100.0 %3
202111200.0 %4
20228011.2 %1
20237611.3 %0
202410500.0 %1
2025*6811.5 %4

* 2025 (hatched bar): data to 29 Nov 2025 (incomplete year; not used in the trends).

By vessel type

Vessel typeFindings
Passenger Ship418
Barge211
not specified70
Towing Vessel39
Offshore13
General Dry Cargo Ship12
Miscellaneous Vessel11
Bulk Carrier8
Ro-Ro Cargo Ship2
School Ship2
Tank Ship2