Rockwool and mineral wool insulation on a ship is chosen first for fire class -- how it behaves when it, not the space around it, is what stands between a fire and the next compartment -- and only afterward for its thermal or acoustic performance.

6models
Sika Services
Knowledge

What to check on an Insulation Materials.

6 models from Sika Services in Insulation Materials. Below: the full model list.

What sets this material apart

Insulation materials in accommodation and machinery spaces do two unrelated jobs at once: they slow heat transfer or absorb sound, and they form part of the structural fire protection that keeps a fire contained to its compartment of origin for a defined time. Rockwool and mineral wool are used precisely because they are non-combustible and keep performing that second job at temperatures that would destroy foam-based insulation outright. That is the real difference from ordinary building insulation, where thermal or acoustic performance is the only criterion.

Bulkhead insulation build-up
Cross section through an insulated steel bulkhead showing, layer by layer, the steel plate, the mineral wool insulation batt held by a fixing pin and washer, the vapour barrier and the outer lining panel.

Legend

  1. steel deck / bulkhead
  2. insulation batt (mineral wool)
  3. vapour barrier
  4. lining panel
  5. fixing pin and washer
Read the full guide

Main components

Bulkhead and deck insulation slabs

Rigid or semi-rigid mineral wool slabs fitted to steel bulkheads and decks as part of an A-class or B-class division, faced with foil or wire mesh to hold shape and resist vibration damage.

Pipe insulation

Preformed mineral wool sections or wrap-around mats for steam, exhaust and hot water piping, finished with cladding to protect against physical damage and moisture.

Loose or blanket fill

Used behind linings and in irregular spaces where preformed slabs do not fit, held in place with pins or mesh.

Facings and cladding

Aluminium foil, wire mesh reinforcement, or metal cladding sheets that protect the wool from mechanical damage and, on pipework, from oil or fuel contact that would otherwise saturate it.

Selection and sizing

Thickness and density are set by the fire division rating required (A-0 through A-60, or B-0/B-15), by the thermal performance needed for the surface temperature limit on hot pipework, and by acoustic requirements in accommodation spaces. Density matters as much as thickness: a low-density wool insulates well thermally but performs worse acoustically and can compress over time, while higher-density product holds its fire and acoustic rating longer under vibration.

Regulations and class

SOLAS Ch. II-2 sets the fire division standards (A-class, B-class) that determine which insulation, thickness and facing combination is acceptable in a given bulkhead or deck. Materials must be non-combustible to IMO FTP Code Part 1 test standards, with type approval certificates tying the specific product to its tested fire rating. Substituting an untested product of similar appearance invalidates the fire division even if the insulation looks identical.

Typical faults

  • Oil or fuel saturation of pipe insulation -- a leaking flange soaks the wool; the consequence is a serious fire risk, since saturated mineral wool can smoulder and sustain a fire rather than resist it.
  • Compressed or displaced slabs -- vibration and inadequate fixing let insulation slump away from the steel; the consequence is a cold bridge or, on a fire division, a gap in the rated barrier.
  • Moisture ingress behind cladding -- damaged cladding lets condensation or wash water in; the consequence is corrosion of the steel underneath, hidden from view until the cladding is removed.
  • Wrong product substituted at repair -- using generic insulation instead of the type-approved product; the consequence is an invalid fire division that will fail the next survey.

What to look for in a supplier

  • Type approval certificates for the specific fire class the insulation is being installed to satisfy.
  • Density and thickness matched to both the fire rating and the acoustic or thermal target, not the cheapest slab that meets one of the two.
  • Facing and cladding compatible with the space's exposure to oil, fuel or moisture.
  • Consistent batch documentation so a fire division can be traced back to its certificate at survey.

Inspect pipe insulation near flanges and valves for oil staining at every opportunity -- saturated wool is invisible from the outside once cladding is refitted, and it is one of the few insulation faults that turns a maintenance item into a fire hazard.

Models

Models in this type.

The best-documented model of each manufacturer first, then the next — 6 of 6 models in Insulation Materials. Every row links to full specifications, documents and service notes.

Showing only Sika Services. Show all manufacturers
6 models
By manufacturer

Manufacturers.

All 137 manufacturers with models of Insulation Materials. Names with a manufacturer page open it; the others open a search across the full library.

All manufacturers
Show all 137 manufacturers
Related types

Also in Marine Interior & Construction Materials.

The other equipment types in this category.

Adhesives & SealantsAnti-Glare SunscreenFRP GratingFire Division Penetration Seal (Class A/B)Flame-Retardant Curtains & TextilesGeneral Interior MaterialsMarine FlooringMarine SeatingWall & Ceiling PanelsWood Products (Plywood / Laminated Wood)
Would you like to know more?

One request. A person reads it and replies by e-mail.

Tell us the manufacturer, the model and what you need — a part, a service call, a second opinion. A person reads every request and replies by e-mail.

No details at hand? A photo of the rating plate or the part is enough — simply attach it to the request.

Frequently asked

Three things people ask first.

Is Insulation Materials data free?

Yes. Every model page, every guide and every datasheet for this type is readable without an account. An account adds saved searches and requests, nothing is taken away.

My model is missing — what now?

Send us the nameplate. We identify it by hand, add it to the library, and if you need a part or a service, the request is already on our desk.

Can you source a Insulation Materials part?

Yes. Tell us the manufacturer, the model and what you need — a person reads every request and replies by e-mail.