Oil Mist Detector

An oil mist detector samples crankcase atmosphere continuously and alarms or trips the engine when oil mist concentration crosses a set threshold, giving the crew minutes of warning before a hot bearing or piston can raise mist density enough to explode.

13models
Hanla IMS
Knowledge

What to check on an Oil Mist Detector.

13 models from Hanla IMS in Oil Mist Detector. Below: the full model list.

What sets an oil mist detector apart

An oil mist detector measures the fine suspended oil droplets inside a running engine's crankcase, not smoke or open flame like a conventional fire detector. It works because a failing bearing or an overheating piston skirt throws off oil mist well before the surface is hot enough to ignite anything directly, so the detector catches the failure at its earliest physical sign. This is what separates it from a simple high-temperature alarm on the lubricating oil system, which reacts only after bulk oil temperature has already risen.

Oil mist detector flow schematic
Flow schematic of a crankcase oil mist detector showing sample tubes from the crankcase converging on the rotary sampling head, the exhauster fan drawing the sample through the measuring chamber with its light source and photocell, and the signal to the alarm and trip unit.

Legend

  1. rotary sampling head
  2. measuring chamber
  3. CRANKCASE
  4. light source
  5. photocell
  6. exhauster fan
  7. ALARM & TRIP UNIT
  8. alarm / engine trip

Main components

Sampling points and pipework

Each crankcase compartment, or in older point-type systems a single central chamber, is connected by small-bore sampling tubes to the detector unit, drawing a continuous air sample past a light source.

Optical measuring chamber

Mist density is measured by light obscuration or scatter as the sample passes through a beam; a rising mist concentration reduces light transmission, which the unit converts into an alarm or trip signal.

Read the full guide

Alarm and trip logic

Modern centralised systems monitor every cylinder individually and can pinpoint which compartment triggered the alarm, unlike older single-point designs that only confirm a mist condition exists somewhere in the crankcase. The unit interfaces with the engine safety system to trip the engine automatically at the highest alarm level.

Selection and sizing

Selection follows the engine builder's specification for cylinder count and crankcase volume, since the sampling cycle time and number of measuring points must match the number of compartments to give a useful response time. Response speed matters more than absolute sensitivity: a system that samples every cylinder every few seconds catches a developing fault sooner than one with a longer scan cycle.

Regulations and class requirements

SOLAS Chapter II-2 requires crankcase oil mist detection or an equivalent bearing temperature monitoring arrangement on propulsion and auxiliary engines above a threshold power, following IACS unified requirements on crankcase explosion protection. Class surveys check that the detector is functional, that alarm and trip set points match the engine builder's approved values, and that the system has not been bypassed or left in an inhibited state.

Typical faults

  • Blocked or oil-fouled sampling tube — that compartment reads falsely low and a real mist condition goes undetected
  • Contaminated optical chamber — false alarms that crews learn to distrust, increasing the risk a real alarm gets ignored
  • Sampling fan or exhauster failure — no sample reaches the measuring chamber at all, often with no obvious external symptom
  • Alarm inhibited during maintenance and not reset — engine runs unprotected after the work is finished
  • Set points altered from the engine builder's approved values — either nuisance trips or a dangerously late trip

What to look for in a supplier

  • Type approval matching the specific engine builder's crankcase explosion relief and monitoring requirements
  • Individual cylinder resolution rather than single-point detection for faster fault location
  • Sample cycle time suited to the engine's cylinder count and running speed
  • Clear local and remote alarm indication, distinguishing a sensor fault from an actual mist alarm
  • Spare optical chambers and sampling tube kits held for the exact model fitted

Never leave a detector inhibited after maintenance without a clear handover note and a positive check that it has been re-enabled; an unprotected engine gives no other warning before a crankcase explosion.

By manufacturer

Manufacturers.

All 15 manufacturers with models of Oil Mist Detector. Names with a manufacturer page open it; the others open a search across the full library.

All manufacturers
Related types

Also in Oil Mist Detection.

The other equipment types in this category.

Bearing Temperature Monitor
Would you like to know more?

One request. A person reads it and replies by e-mail.

Tell us the manufacturer, the model and what you need — a part, a service call, a second opinion. A person reads every request and replies by e-mail.

No details at hand? A photo of the rating plate or the part is enough — simply attach it to the request.

Frequently asked

Three things people ask first.

Is Oil Mist Detector data free?

Yes. Every model page, every guide and every datasheet for this type is readable without an account. An account adds saved searches and requests, nothing is taken away.

My model is missing — what now?

Send us the nameplate. We identify it by hand, add it to the library, and if you need a part or a service, the request is already on our desk.

Can you source a Oil Mist Detector part?

Yes. Tell us the manufacturer, the model and what you need — a person reads every request and replies by e-mail.