medium 110 models total

A UV sterilizer disinfects water by exposing it to ultraviolet light as it flows past a lamp, killing bacteria and viruses without adding any chemical to the water, which is why it is fitted at the point of use rather than relied on to protect stored water over time.

Read more — UV Sterilizer explained

What Sets UV Sterilization Apart

A UV sterilizer inactivates microorganisms by damaging their DNA as water passes through a chamber past a UV-C lamp, with no chemical dosing and no taste or odour change to the water. That is its strength and its limitation at the same time: it works only at the point the water actually passes the lamp, and it leaves no residual protection afterward. Water sitting in a tank or a long dead-leg pipe run downstream of a UV unit can still support bacterial regrowth, which is exactly the gap that chlorination is used to cover. On ships, UV is typically fitted close to the point of use, for example just before the potable water distribution manifold or on a dedicated drinking water line, rather than as the sole treatment for stored water.

UV sterilizer, section
Cross section of an inline UV sterilizer: water flows through the annular gap between the chamber housing and the quartz sleeve while the UV lamp inside the sleeve disinfects it, with the ballast and lamp connector shown outside the flow.

Main Components

UV Lamp

A low-pressure or medium-pressure mercury vapour lamp, or increasingly a UV-C LED array, generating radiation at the wavelength that damages microbial DNA, housed inside a quartz sleeve.

Quartz Sleeve

A sleeve that keeps the lamp dry and out of direct contact with the water while remaining transparent to UV light; fouling of this sleeve is the most common cause of falling dose delivered.

Reactor Chamber

The stainless steel vessel the water flows through, designed so every parcel of water gets adequate exposure time and does not short-circuit past the lamp.

UV Intensity Sensor

A sensor monitoring actual UV output through the water, allowing the controller to flag a failing lamp or a fouled sleeve before dose delivery drops below the safe threshold.

Automatic Wiper or Cleaning Mechanism

Fitted on some units to mechanically clean the quartz sleeve without shutting the unit down, reducing the manual cleaning burden.

Selection and Sizing

  • Flow rate through the unit at the point it is installed, which sets chamber size and required lamp power to hold dose above the target at maximum flow.
  • Water UV transmittance, since turbid or coloured water absorbs UV and reduces the effective dose reaching microorganisms.
  • Target dose, generally expressed in mJ/cm2, sufficient to inactivate the organisms of concern at the design flow rate.
  • Lamp type and expected service life, since output degrades over the lamp's life well before it fails outright.

Regulations and Class

UV treatment of potable water is assessed against the same flag state and WHO-based drinking water quality benchmarks as other treatment methods, with the focus on microbiological rather than chemical parameters since UV adds nothing to the water. Where UV treats ballast water rather than potable water, it typically forms part of a type-approved system under the IMO Ballast Water Management Convention, and that is a materially different application from a domestic potable water UV unit; the two should not be confused when specifying equipment or reviewing certification.

Typical Faults

FaultCauseConsequence
Falling UV doseFouled quartz sleeve or lamp reaching end of rated lifeIncomplete disinfection despite the unit still running normally
Lamp failure without alarmIntensity sensor not fitted or not monitoredWater passes untreated with no indication to the crew
Reduced flow capacityScale buildup inside the reactor chamberIncreased contact time needed, or bypass of unit under high demand
Frequent lamp failuresVoltage fluctuations or vibration at the installation locationRising spare lamp consumption and unplanned downtime

What to Look for in a Supplier

  • A UV intensity sensor with an alarm output, not just a lamp-on indicator, since a dim lamp still lights up.
  • Rated dose delivery at the vessel's actual maximum flow rate and expected water transmittance, not a best-case laboratory figure.
  • Lamp replacement interval and cost of consumables clearly stated, since lamps are a recurring maintenance item.
  • Chamber material and fittings suited to shipboard vibration and the water chemistry on board.

A UV unit with no working intensity sensor gives false confidence, always confirm the sensor and its alarm are actually monitored, not just the lamp indicator light.

8 manufacturers · 110 models

Alfa Laval

16
Smit UV 1 Marine unverified
Capacity (m³/h)
1
Treatment Type
UV Sterilization
Uv dose mj cm2
40
Common Failures & Inspection Points
  • Scale, membrane fouling or dirty optical surfaces reduce treatment capacity or water quality
  • Pump, vacuum, lamp or power-supply faults cause low production, low treatment intensity or shutdown
  • Conductivity, salinity or intensity-sensor faults cause false acceptance, rejection or alarms
  • Seal, gasket or piping leakage causes loss of pressure, vacuum or visible water leakage
  • Pretreatment or strainer blockage reduces feed flow and causes unstable operation
Service: Inspect feed strainers, pumps, membranes or heat-transfer surfaces, UV lamps where fitted, product-water monitoring and diverting arrangements. Trend production and water quality. Keep pretreatment equipment clean and prevent doubtful product water from entering service tanks. Refer to the manufacturer documentation for the exact figure for pressure, cleaning and quality criteria.
Spare Parts: Carry filters, strainers, pump seals, membrane or UV components as applicable, conductivity or intensity sensors, valve parts and approved cleaning consumables.
Use Cases: Freshwater production and potable or process-water disinfection.
Smit UV 3 Marine unverified
Capacity (m³/h)
3
Treatment Type
UV Sterilization
Uv dose mj cm2
40
Common Failures & Inspection Points
  • Scale, membrane fouling or dirty optical surfaces reduce treatment capacity or water quality
  • Pump, vacuum, lamp or power-supply faults cause low production, low treatment intensity or shutdown
  • Conductivity, salinity or intensity-sensor faults cause false acceptance, rejection or alarms
  • Seal, gasket or piping leakage causes loss of pressure, vacuum or visible water leakage
  • Pretreatment or strainer blockage reduces feed flow and causes unstable operation
Service: Inspect feed strainers, pumps, membranes or heat-transfer surfaces, UV lamps where fitted, product-water monitoring and diverting arrangements. Trend production and water quality. Keep pretreatment equipment clean and prevent doubtful product water from entering service tanks. Refer to the manufacturer documentation for the exact figure for pressure, cleaning and quality criteria.
Spare Parts: Carry filters, strainers, pump seals, membrane or UV components as applicable, conductivity or intensity sensors, valve parts and approved cleaning consumables.
Use Cases: Freshwater production and potable or process-water disinfection.
Smit UV 5 Marine unverified
Capacity (m³/h)
5
Treatment Type
UV Sterilization
Uv dose mj cm2
40
Common Failures & Inspection Points
  • Scale, membrane fouling or dirty optical surfaces reduce treatment capacity or water quality
  • Pump, vacuum, lamp or power-supply faults cause low production, low treatment intensity or shutdown
  • Conductivity, salinity or intensity-sensor faults cause false acceptance, rejection or alarms
  • Seal, gasket or piping leakage causes loss of pressure, vacuum or visible water leakage
  • Pretreatment or strainer blockage reduces feed flow and causes unstable operation
Service: Inspect feed strainers, pumps, membranes or heat-transfer surfaces, UV lamps where fitted, product-water monitoring and diverting arrangements. Trend production and water quality. Keep pretreatment equipment clean and prevent doubtful product water from entering service tanks. Refer to the manufacturer documentation for the exact figure for pressure, cleaning and quality criteria.
Spare Parts: Carry filters, strainers, pump seals, membrane or UV components as applicable, conductivity or intensity sensors, valve parts and approved cleaning consumables.
Use Cases: Freshwater production and potable or process-water disinfection.
Smit UV 10 Marine unverified
Capacity (m³/h)
10
Treatment Type
UV Sterilization
Uv dose mj cm2
40
Common Failures & Inspection Points
  • Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
  • Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
  • Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
  • Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
  • Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
Service: Inspect the unit for leakage, corrosion, contamination, loose connections, abnormal noise or vibration, condition of guards and mountings, service supplies, controls, alarms, and functional performance. Use the vessel maintenance history to identify deterioration trends and refer to the manufacturer documentation for exact settings, tolerances, test values, and overhaul criteria.
Spare Parts: Keep the manufacturer-recommended seals and gaskets, filters where fitted, fuses or protection items, common sensors and switches, and critical actuator, control, or wear components appropriate to the installed configuration. Exact part numbers and quantities must come from the manufacturer spare-parts documentation.
Use Cases: Used on vessel types fitted with water treatment equipment, including merchant, offshore, passenger, fishing, or workboat installations where this specific uv sterilizer duty is required.
Smit UV 20 Marine unverified
Capacity (m³/h)
20
Treatment Type
UV Sterilization
Uv dose mj cm2
40
Common Failures & Inspection Points
  • Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
  • Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
  • Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
  • Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
  • Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
Service: Inspect the unit for leakage, corrosion, contamination, loose connections, abnormal noise or vibration, condition of guards and mountings, service supplies, controls, alarms, and functional performance. Use the vessel maintenance history to identify deterioration trends and refer to the manufacturer documentation for exact settings, tolerances, test values, and overhaul criteria.
Spare Parts: Keep the manufacturer-recommended seals and gaskets, filters where fitted, fuses or protection items, common sensors and switches, and critical actuator, control, or wear components appropriate to the installed configuration. Exact part numbers and quantities must come from the manufacturer spare-parts documentation.
Use Cases: Used on vessel types fitted with water treatment equipment, including merchant, offshore, passenger, fishing, or workboat installations where this specific uv sterilizer duty is required.
UV Sterilizer 0.5m3h Alfa Marine unverified
Capacity (m³/h)
0.5
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Scale, exhausted media or dirty treatment surfaces reduce treatment effectiveness and cause poor water quality
  • Lamp, dosing pump, valve or power-supply faults cause loss of treatment and system alarms
  • Sensor, conductivity or dosing-control faults cause under-treatment, over-treatment or false indication
  • Filter or strainer blockage reduces flow and increases differential pressure
  • Seal, vessel or piping leakage causes water loss and may contaminate the treatment area
Service: Inspect treatment elements, filters, pumps, dosing equipment, sensors, valves and leakage according to the installed process. Trend water-quality results and replace or regenerate treatment media using approved procedures. Keep chemical and UV safety controls intact. Refer to the manufacturer documentation for the exact figure for dose, flow, regeneration and water-quality criteria.
Spare Parts: Carry filters, lamps or treatment media as applicable, pump seals, dosing tubing, sensors, valve parts and approved treatment consumables.
Use Cases: Potable-water disinfection, softening, mineral conditioning and domestic water treatment.
UV Sterilizer 1m3h Alfa Marine unverified
Capacity (m³/h)
1
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • UV lamp/sleeve fouling or lamp failure where applicable, typically indicated by low-UV alarm or inadequate sterilization
  • Dosing pump or chemical-feed blockage, typically indicated by incorrect treatment rate or water-quality deviation
  • Softener resin exhaustion/fouling where applicable, typically indicated by hardness breakthrough or poor regeneration
  • Sensor or flow-switch fault, typically indicated by incorrect dosing/control or alarm
  • Filter/line blockage or scaling, typically indicated by reduced flow or pressure
Service: Inspect treatment vessels, lamps/dosing equipment, filters, sensors, chemical levels and water-quality records; clean and replace consumables under approved procedures and use manufacturer documentation for exact dosing or exposure values.
Spare Parts: Keep UV lamps/sleeves where fitted, dosing-pump kits, filters, seals, sensors and approved treatment consumables.
Use Cases: Used on passenger, cargo, offshore and naval vessels to maintain potable and service-water quality. This entry applies specifically to the UV Sterilizer variant identified as Alfa Laval UV Sterilizer 1m3h Alfa Marine.
UV Sterilizer 2m3h Alfa Marine unverified
Capacity (m³/h)
2
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • UV lamp/sleeve fouling or lamp failure where applicable, typically indicated by low-UV alarm or inadequate sterilization
  • Dosing pump or chemical-feed blockage, typically indicated by incorrect treatment rate or water-quality deviation
  • Softener resin exhaustion/fouling where applicable, typically indicated by hardness breakthrough or poor regeneration
  • Sensor or flow-switch fault, typically indicated by incorrect dosing/control or alarm
  • Filter/line blockage or scaling, typically indicated by reduced flow or pressure
Service: Inspect treatment vessels, lamps/dosing equipment, filters, sensors, chemical levels and water-quality records; clean and replace consumables under approved procedures and use manufacturer documentation for exact dosing or exposure values.
Spare Parts: Keep UV lamps/sleeves where fitted, dosing-pump kits, filters, seals, sensors and approved treatment consumables.
Use Cases: Used on passenger, cargo, offshore and naval vessels to maintain potable and service-water quality. This entry applies specifically to the UV Sterilizer variant identified as Alfa Laval UV Sterilizer 2m3h Alfa Marine.
UV Sterilizer 3m3h Alfa Marine unverified
Capacity (m³/h)
3
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • UV lamp/sleeve fouling or lamp failure where applicable, typically indicated by low-UV alarm or inadequate sterilization
  • Dosing pump or chemical-feed blockage, typically indicated by incorrect treatment rate or water-quality deviation
  • Softener resin exhaustion/fouling where applicable, typically indicated by hardness breakthrough or poor regeneration
  • Sensor or flow-switch fault, typically indicated by incorrect dosing/control or alarm
  • Filter/line blockage or scaling, typically indicated by reduced flow or pressure
Service: Inspect treatment vessels, lamps/dosing equipment, filters, sensors, chemical levels and water-quality records; clean and replace consumables under approved procedures and use manufacturer documentation for exact dosing or exposure values.
Spare Parts: Keep UV lamps/sleeves where fitted, dosing-pump kits, filters, seals, sensors and approved treatment consumables.
Use Cases: Used on passenger, cargo, offshore and naval vessels to maintain potable and service-water quality. This entry applies specifically to the UV Sterilizer variant identified as Alfa Laval UV Sterilizer 3m3h Alfa Marine.
UV Sterilizer 5m3h Alfa Marine unverified
Capacity (m³/h)
5
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • UV lamp/sleeve fouling or lamp failure where applicable, typically indicated by low-UV alarm or inadequate sterilization
  • Dosing pump or chemical-feed blockage, typically indicated by incorrect treatment rate or water-quality deviation
  • Softener resin exhaustion/fouling where applicable, typically indicated by hardness breakthrough or poor regeneration
  • Sensor or flow-switch fault, typically indicated by incorrect dosing/control or alarm
  • Filter/line blockage or scaling, typically indicated by reduced flow or pressure
Service: Inspect treatment vessels, lamps/dosing equipment, filters, sensors, chemical levels and water-quality records; clean and replace consumables under approved procedures and use manufacturer documentation for exact dosing or exposure values.
Spare Parts: Keep UV lamps/sleeves where fitted, dosing-pump kits, filters, seals, sensors and approved treatment consumables.
Use Cases: Used on passenger, cargo, offshore and naval vessels to maintain potable and service-water quality. This entry applies specifically to the UV Sterilizer variant identified as Alfa Laval UV Sterilizer 5m3h Alfa Marine.
UV Sterilizer 8m3h Alfa Marine unverified
Capacity (m³/h)
8
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • UV lamp/sleeve fouling or lamp failure where applicable, typically indicated by low-UV alarm or inadequate sterilization
  • Dosing pump or chemical-feed blockage, typically indicated by incorrect treatment rate or water-quality deviation
  • Softener resin exhaustion/fouling where applicable, typically indicated by hardness breakthrough or poor regeneration
  • Sensor or flow-switch fault, typically indicated by incorrect dosing/control or alarm
  • Filter/line blockage or scaling, typically indicated by reduced flow or pressure
Service: Inspect treatment vessels, lamps/dosing equipment, filters, sensors, chemical levels and water-quality records; clean and replace consumables under approved procedures and use manufacturer documentation for exact dosing or exposure values.
Spare Parts: Keep UV lamps/sleeves where fitted, dosing-pump kits, filters, seals, sensors and approved treatment consumables.
Use Cases: Used on passenger, cargo, offshore and naval vessels to maintain potable and service-water quality. This entry applies specifically to the UV Sterilizer variant identified as Alfa Laval UV Sterilizer 8m3h Alfa Marine.
UV Sterilizer 10m3h Alfa Marine unverified
Capacity (m³/h)
10
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Scale, exhausted media or dirty treatment surfaces reduce treatment effectiveness and cause poor water quality
  • Lamp, dosing pump, valve or power-supply faults cause loss of treatment and system alarms
  • Sensor, conductivity or dosing-control faults cause under-treatment, over-treatment or false indication
  • Filter or strainer blockage reduces flow and increases differential pressure
  • Seal, vessel or piping leakage causes water loss and may contaminate the treatment area
Service: Inspect treatment elements, filters, pumps, dosing equipment, sensors, valves and leakage according to the installed process. Trend water-quality results and replace or regenerate treatment media using approved procedures. Keep chemical and UV safety controls intact. Refer to the manufacturer documentation for the exact figure for dose, flow, regeneration and water-quality criteria.
Spare Parts: Carry filters, lamps or treatment media as applicable, pump seals, dosing tubing, sensors, valve parts and approved treatment consumables.
Use Cases: Potable-water disinfection, softening, mineral conditioning and domestic water treatment.
UV Sterilizer 15m3h Alfa Marine unverified
Capacity (m³/h)
15
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Scale, exhausted media or dirty treatment surfaces reduce treatment effectiveness and cause poor water quality
  • Lamp, dosing pump, valve or power-supply faults cause loss of treatment and system alarms
  • Sensor, conductivity or dosing-control faults cause under-treatment, over-treatment or false indication
  • Filter or strainer blockage reduces flow and increases differential pressure
  • Seal, vessel or piping leakage causes water loss and may contaminate the treatment area
Service: Inspect treatment elements, filters, pumps, dosing equipment, sensors, valves and leakage according to the installed process. Trend water-quality results and replace or regenerate treatment media using approved procedures. Keep chemical and UV safety controls intact. Refer to the manufacturer documentation for the exact figure for dose, flow, regeneration and water-quality criteria.
Spare Parts: Carry filters, lamps or treatment media as applicable, pump seals, dosing tubing, sensors, valve parts and approved treatment consumables.
Use Cases: Potable-water disinfection, softening, mineral conditioning and domestic water treatment.
UV Sterilizer 20m3h Alfa Marine unverified
Capacity (m³/h)
20
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Scale, exhausted media or dirty treatment surfaces reduce treatment effectiveness and cause poor water quality
  • Lamp, dosing pump, valve or power-supply faults cause loss of treatment and system alarms
  • Sensor, conductivity or dosing-control faults cause under-treatment, over-treatment or false indication
  • Filter or strainer blockage reduces flow and increases differential pressure
  • Seal, vessel or piping leakage causes water loss and may contaminate the treatment area
Service: Inspect treatment elements, filters, pumps, dosing equipment, sensors, valves and leakage according to the installed process. Trend water-quality results and replace or regenerate treatment media using approved procedures. Keep chemical and UV safety controls intact. Refer to the manufacturer documentation for the exact figure for dose, flow, regeneration and water-quality criteria.
Spare Parts: Carry filters, lamps or treatment media as applicable, pump seals, dosing tubing, sensors, valve parts and approved treatment consumables.
Use Cases: Potable-water disinfection, softening, mineral conditioning and domestic water treatment.
UV Sterilizer 30m3h Alfa Marine unverified
Capacity (m³/h)
30
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Scale, exhausted media or dirty treatment surfaces reduce treatment effectiveness and cause poor water quality
  • Lamp, dosing pump, valve or power-supply faults cause loss of treatment and system alarms
  • Sensor, conductivity or dosing-control faults cause under-treatment, over-treatment or false indication
  • Filter or strainer blockage reduces flow and increases differential pressure
  • Seal, vessel or piping leakage causes water loss and may contaminate the treatment area
Service: Inspect treatment elements, filters, pumps, dosing equipment, sensors, valves and leakage according to the installed process. Trend water-quality results and replace or regenerate treatment media using approved procedures. Keep chemical and UV safety controls intact. Refer to the manufacturer documentation for the exact figure for dose, flow, regeneration and water-quality criteria.
Spare Parts: Carry filters, lamps or treatment media as applicable, pump seals, dosing tubing, sensors, valve parts and approved treatment consumables.
Use Cases: Potable-water disinfection, softening, mineral conditioning and domestic water treatment.
Alfa Laval UV Sterilizer 50m3h Alfa Marine
UV Sterilizer 50m3h Alfa Marine unverified
Capacity (m³/h)
50
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Scale, exhausted media or dirty treatment surfaces reduce treatment effectiveness and cause poor water quality
  • Lamp, dosing pump, valve or power-supply faults cause loss of treatment and system alarms
  • Sensor, conductivity or dosing-control faults cause under-treatment, over-treatment or false indication
  • Filter or strainer blockage reduces flow and increases differential pressure
  • Seal, vessel or piping leakage causes water loss and may contaminate the treatment area
Service: Inspect treatment elements, filters, pumps, dosing equipment, sensors, valves and leakage according to the installed process. Trend water-quality results and replace or regenerate treatment media using approved procedures. Keep chemical and UV safety controls intact. Refer to the manufacturer documentation for the exact figure for dose, flow, regeneration and water-quality criteria.
Spare Parts: Carry filters, lamps or treatment media as applicable, pump seals, dosing tubing, sensors, valve parts and approved treatment consumables.
Use Cases: Potable-water disinfection, softening, mineral conditioning and domestic water treatment.

Evoqua/Xylem Marine

16
UV-1M Marine unverified
Capacity (m³/h)
1
Treatment Type
UV Sterilization
Uv dose mj cm2
40
Common Failures & Inspection Points
  • Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
  • Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
  • Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
  • Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
  • Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
Service: Inspect the unit for leakage, corrosion, contamination, loose connections, abnormal noise or vibration, condition of guards and mountings, service supplies, controls, alarms, and functional performance. Use the vessel maintenance history to identify deterioration trends and refer to the manufacturer documentation for exact settings, tolerances, test values, and overhaul criteria.
Spare Parts: Keep the manufacturer-recommended seals and gaskets, filters where fitted, fuses or protection items, common sensors and switches, and critical actuator, control, or wear components appropriate to the installed configuration. Exact part numbers and quantities must come from the manufacturer spare-parts documentation.
Use Cases: Used on vessel types fitted with water treatment equipment, including merchant, offshore, passenger, fishing, or workboat installations where this specific uv sterilizer duty is required.
UV-3M Marine unverified
Capacity (m³/h)
3
Treatment Type
UV Sterilization
Uv dose mj cm2
40
Common Failures & Inspection Points
  • Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
  • Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
  • Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
  • Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
  • Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
Service: Inspect the unit for leakage, corrosion, contamination, loose connections, abnormal noise or vibration, condition of guards and mountings, service supplies, controls, alarms, and functional performance. Use the vessel maintenance history to identify deterioration trends and refer to the manufacturer documentation for exact settings, tolerances, test values, and overhaul criteria.
Spare Parts: Keep the manufacturer-recommended seals and gaskets, filters where fitted, fuses or protection items, common sensors and switches, and critical actuator, control, or wear components appropriate to the installed configuration. Exact part numbers and quantities must come from the manufacturer spare-parts documentation.
Use Cases: Used on vessel types fitted with water treatment equipment, including merchant, offshore, passenger, fishing, or workboat installations where this specific uv sterilizer duty is required.
UV-5M Marine unverified
Capacity (m³/h)
5
Treatment Type
UV Sterilization
Uv dose mj cm2
40
Common Failures & Inspection Points
  • Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
  • Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
  • Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
  • Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
  • Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
Service: Inspect the unit for leakage, corrosion, contamination, loose connections, abnormal noise or vibration, condition of guards and mountings, service supplies, controls, alarms, and functional performance. Use the vessel maintenance history to identify deterioration trends and refer to the manufacturer documentation for exact settings, tolerances, test values, and overhaul criteria.
Spare Parts: Keep the manufacturer-recommended seals and gaskets, filters where fitted, fuses or protection items, common sensors and switches, and critical actuator, control, or wear components appropriate to the installed configuration. Exact part numbers and quantities must come from the manufacturer spare-parts documentation.
Use Cases: Used on vessel types fitted with water treatment equipment, including merchant, offshore, passenger, fishing, or workboat installations where this specific uv sterilizer duty is required.
UV-10M Marine unverified
Capacity (m³/h)
10
Treatment Type
UV Sterilization
Uv dose mj cm2
40
Common Failures & Inspection Points
  • Filter, membrane, separator or treatment-stage fouling caused by solids, oil, scale or biological contamination can reduce throughput and increase differential pressure
  • Pump or valve faults caused by wear, blockage or actuator problems can cause low flow, unstable pressure or failure to complete an operating sequence
  • Sensor or monitor contamination caused by dirty process fluid or poor maintenance can produce implausible readings, alarms or automatic discharge inhibition
  • Seal, gasket or piping leakage caused by corrosion, ageing or vibration can lead to visible leakage, air ingress or loss of process pressure
  • Control or treatment-component failure caused by electrical faults, lamp or cell deterioration where fitted, or software issues can lead to shutdown or inability to meet the required treatment condition
Service: Inspect filters or treatment elements, pumps, valves, piping, sampling points and monitors, and review trend data for loss of throughput or abnormal pressure. Verify alarms, automatic diversion or interlocks where applicable and check cleanliness of sensors and sample lines. Use statutory procedures and manufacturer documentation for exact discharge, treatment and calibration limits.
Spare Parts: Typical spares include filters or treatment elements, seal and gasket kits, pump service parts, lamps or electrodes where applicable, monitor consumables, sensors and valve or actuator repair items.
Use Cases: Bilge-water treatment, fuel or lube purification, freshwater production, potable-water conditioning and ballast-water management on commercial vessels.
UV-20M Marine unverified
Capacity (m³/h)
20
Treatment Type
UV Sterilization
Uv dose mj cm2
40
Common Failures & Inspection Points
  • Filter, membrane, separator or treatment-stage fouling caused by solids, oil, scale or biological contamination can reduce throughput and increase differential pressure
  • Pump or valve faults caused by wear, blockage or actuator problems can cause low flow, unstable pressure or failure to complete an operating sequence
  • Sensor or monitor contamination caused by dirty process fluid or poor maintenance can produce implausible readings, alarms or automatic discharge inhibition
  • Seal, gasket or piping leakage caused by corrosion, ageing or vibration can lead to visible leakage, air ingress or loss of process pressure
  • Control or treatment-component failure caused by electrical faults, lamp or cell deterioration where fitted, or software issues can lead to shutdown or inability to meet the required treatment condition
Service: Inspect filters or treatment elements, pumps, valves, piping, sampling points and monitors, and review trend data for loss of throughput or abnormal pressure. Verify alarms, automatic diversion or interlocks where applicable and check cleanliness of sensors and sample lines. Use statutory procedures and manufacturer documentation for exact discharge, treatment and calibration limits.
Spare Parts: Typical spares include filters or treatment elements, seal and gasket kits, pump service parts, lamps or electrodes where applicable, monitor consumables, sensors and valve or actuator repair items.
Use Cases: Bilge-water treatment, fuel or lube purification, freshwater production, potable-water conditioning and ballast-water management on commercial vessels.
UV Sterilizer 0.5m3h Evoqua/Xylem Marine unverified
Capacity (m³/h)
0.5
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Fouling or exhausted treatment media can reduce treatment effectiveness, seen as deteriorating outlet-water quality or rising differential pressure
  • Dosing-pump or chemical-feed faults can interrupt treatment, noticed as unstable readings, low dosing indication or quality alarms
  • Blocked strainers or restricted piping can reduce flow, seen as low throughput or abnormal pump loading
  • Sensor drift or contamination can give incorrect control feedback, noticed as implausible readings or unnecessary alarms
  • Valve, seal or hose leakage can cause loss of treatment fluid or water, seen as wetness around the skid and inability to maintain normal operation
Service: Check water quality indicators, strainers, dosing points, media condition, pumps, valves, sensors and leak tightness. Confirm the unit changes state correctly between service, regeneration, flushing or standby modes where fitted. For chemical concentration, flow limits or replacement criteria not stated in the source entry, refer to the manufacturer documentation for the exact figure.
Spare Parts: Carry the maker-recommended filter elements or treatment consumables, dosing-pump service parts, seals, hoses, sensor consumables and common electrical fuses.
Use Cases: Applied to potable-water production and conditioning, domestic-water systems and other shipboard water services on merchant, passenger and offshore vessels.
UV Sterilizer 1m3h Evoqua/Xylem Marine unverified
Capacity (m³/h)
1
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Fouling or exhausted treatment media can reduce treatment effectiveness, seen as deteriorating outlet-water quality or rising differential pressure
  • Dosing-pump or chemical-feed faults can interrupt treatment, noticed as unstable readings, low dosing indication or quality alarms
  • Blocked strainers or restricted piping can reduce flow, seen as low throughput or abnormal pump loading
  • Sensor drift or contamination can give incorrect control feedback, noticed as implausible readings or unnecessary alarms
  • Valve, seal or hose leakage can cause loss of treatment fluid or water, seen as wetness around the skid and inability to maintain normal operation
Service: Check water quality indicators, strainers, dosing points, media condition, pumps, valves, sensors and leak tightness. Confirm the unit changes state correctly between service, regeneration, flushing or standby modes where fitted. For chemical concentration, flow limits or replacement criteria not stated in the source entry, refer to the manufacturer documentation for the exact figure.
Spare Parts: Carry the maker-recommended filter elements or treatment consumables, dosing-pump service parts, seals, hoses, sensor consumables and common electrical fuses.
Use Cases: Applied to potable-water production and conditioning, domestic-water systems and other shipboard water services on merchant, passenger and offshore vessels.
UV Sterilizer 2m3h Evoqua/Xylem Marine unverified
Capacity (m³/h)
2
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Fouling or exhausted treatment media can reduce treatment effectiveness, seen as deteriorating outlet-water quality or rising differential pressure
  • Dosing-pump or chemical-feed faults can interrupt treatment, noticed as unstable readings, low dosing indication or quality alarms
  • Blocked strainers or restricted piping can reduce flow, seen as low throughput or abnormal pump loading
  • Sensor drift or contamination can give incorrect control feedback, noticed as implausible readings or unnecessary alarms
  • Valve, seal or hose leakage can cause loss of treatment fluid or water, seen as wetness around the skid and inability to maintain normal operation
Service: Check water quality indicators, strainers, dosing points, media condition, pumps, valves, sensors and leak tightness. Confirm the unit changes state correctly between service, regeneration, flushing or standby modes where fitted. For chemical concentration, flow limits or replacement criteria not stated in the source entry, refer to the manufacturer documentation for the exact figure.
Spare Parts: Carry the maker-recommended filter elements or treatment consumables, dosing-pump service parts, seals, hoses, sensor consumables and common electrical fuses.
Use Cases: Applied to potable-water production and conditioning, domestic-water systems and other shipboard water services on merchant, passenger and offshore vessels.
UV Sterilizer 3m3h Evoqua/Xylem Marine unverified
Capacity (m³/h)
3
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Fouling or exhausted treatment media can reduce treatment effectiveness, seen as deteriorating outlet-water quality or rising differential pressure
  • Dosing-pump or chemical-feed faults can interrupt treatment, noticed as unstable readings, low dosing indication or quality alarms
  • Blocked strainers or restricted piping can reduce flow, seen as low throughput or abnormal pump loading
  • Sensor drift or contamination can give incorrect control feedback, noticed as implausible readings or unnecessary alarms
  • Valve, seal or hose leakage can cause loss of treatment fluid or water, seen as wetness around the skid and inability to maintain normal operation
Service: Check water quality indicators, strainers, dosing points, media condition, pumps, valves, sensors and leak tightness. Confirm the unit changes state correctly between service, regeneration, flushing or standby modes where fitted. For chemical concentration, flow limits or replacement criteria not stated in the source entry, refer to the manufacturer documentation for the exact figure.
Spare Parts: Carry the maker-recommended filter elements or treatment consumables, dosing-pump service parts, seals, hoses, sensor consumables and common electrical fuses.
Use Cases: Applied to potable-water production and conditioning, domestic-water systems and other shipboard water services on merchant, passenger and offshore vessels.
UV Sterilizer 5m3h Evoqua/Xylem Marine unverified
Capacity (m³/h)
5
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Fouling or exhausted treatment media can reduce treatment effectiveness, seen as deteriorating outlet-water quality or rising differential pressure
  • Dosing-pump or chemical-feed faults can interrupt treatment, noticed as unstable readings, low dosing indication or quality alarms
  • Blocked strainers or restricted piping can reduce flow, seen as low throughput or abnormal pump loading
  • Sensor drift or contamination can give incorrect control feedback, noticed as implausible readings or unnecessary alarms
  • Valve, seal or hose leakage can cause loss of treatment fluid or water, seen as wetness around the skid and inability to maintain normal operation
Service: Check water quality indicators, strainers, dosing points, media condition, pumps, valves, sensors and leak tightness. Confirm the unit changes state correctly between service, regeneration, flushing or standby modes where fitted. For chemical concentration, flow limits or replacement criteria not stated in the source entry, refer to the manufacturer documentation for the exact figure.
Spare Parts: Carry the maker-recommended filter elements or treatment consumables, dosing-pump service parts, seals, hoses, sensor consumables and common electrical fuses.
Use Cases: Applied to potable-water production and conditioning, domestic-water systems and other shipboard water services on merchant, passenger and offshore vessels.
UV Sterilizer 8m3h Evoqua/Xylem Marine unverified
Capacity (m³/h)
8
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Fouling or exhausted treatment media can reduce treatment effectiveness, seen as deteriorating outlet-water quality or rising differential pressure
  • Dosing-pump or chemical-feed faults can interrupt treatment, noticed as unstable readings, low dosing indication or quality alarms
  • Blocked strainers or restricted piping can reduce flow, seen as low throughput or abnormal pump loading
  • Sensor drift or contamination can give incorrect control feedback, noticed as implausible readings or unnecessary alarms
  • Valve, seal or hose leakage can cause loss of treatment fluid or water, seen as wetness around the skid and inability to maintain normal operation
Service: Check water quality indicators, strainers, dosing points, media condition, pumps, valves, sensors and leak tightness. Confirm the unit changes state correctly between service, regeneration, flushing or standby modes where fitted. For chemical concentration, flow limits or replacement criteria not stated in the source entry, refer to the manufacturer documentation for the exact figure.
Spare Parts: Carry the maker-recommended filter elements or treatment consumables, dosing-pump service parts, seals, hoses, sensor consumables and common electrical fuses.
Use Cases: Applied to potable-water production and conditioning, domestic-water systems and other shipboard water services on merchant, passenger and offshore vessels.
UV Sterilizer 10m3h Evoqua/Xylem Marine unverified
Capacity (m³/h)
10
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Fouling or exhausted treatment media can reduce treatment effectiveness, seen as deteriorating outlet-water quality or rising differential pressure
  • Dosing-pump or chemical-feed faults can interrupt treatment, noticed as unstable readings, low dosing indication or quality alarms
  • Blocked strainers or restricted piping can reduce flow, seen as low throughput or abnormal pump loading
  • Sensor drift or contamination can give incorrect control feedback, noticed as implausible readings or unnecessary alarms
  • Valve, seal or hose leakage can cause loss of treatment fluid or water, seen as wetness around the skid and inability to maintain normal operation
Service: Check water quality indicators, strainers, dosing points, media condition, pumps, valves, sensors and leak tightness. Confirm the unit changes state correctly between service, regeneration, flushing or standby modes where fitted. For chemical concentration, flow limits or replacement criteria not stated in the source entry, refer to the manufacturer documentation for the exact figure.
Spare Parts: Carry the maker-recommended filter elements or treatment consumables, dosing-pump service parts, seals, hoses, sensor consumables and common electrical fuses.
Use Cases: Applied to potable-water production and conditioning, domestic-water systems and other shipboard water services on merchant, passenger and offshore vessels.
UV Sterilizer 15m3h Evoqua/Xylem Marine unverified
Capacity (m³/h)
15
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Fouling or exhausted treatment media can reduce treatment effectiveness, seen as deteriorating outlet-water quality or rising differential pressure
  • Dosing-pump or chemical-feed faults can interrupt treatment, noticed as unstable readings, low dosing indication or quality alarms
  • Blocked strainers or restricted piping can reduce flow, seen as low throughput or abnormal pump loading
  • Sensor drift or contamination can give incorrect control feedback, noticed as implausible readings or unnecessary alarms
  • Valve, seal or hose leakage can cause loss of treatment fluid or water, seen as wetness around the skid and inability to maintain normal operation
Service: Check water quality indicators, strainers, dosing points, media condition, pumps, valves, sensors and leak tightness. Confirm the unit changes state correctly between service, regeneration, flushing or standby modes where fitted. For chemical concentration, flow limits or replacement criteria not stated in the source entry, refer to the manufacturer documentation for the exact figure.
Spare Parts: Carry the maker-recommended filter elements or treatment consumables, dosing-pump service parts, seals, hoses, sensor consumables and common electrical fuses.
Use Cases: Applied to potable-water production and conditioning, domestic-water systems and other shipboard water services on merchant, passenger and offshore vessels.
UV Sterilizer 20m3h Evoqua/Xylem Marine unverified
Capacity (m³/h)
20
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Fouling or exhausted treatment media can reduce treatment effectiveness, seen as deteriorating outlet-water quality or rising differential pressure
  • Dosing-pump or chemical-feed faults can interrupt treatment, noticed as unstable readings, low dosing indication or quality alarms
  • Blocked strainers or restricted piping can reduce flow, seen as low throughput or abnormal pump loading
  • Sensor drift or contamination can give incorrect control feedback, noticed as implausible readings or unnecessary alarms
  • Valve, seal or hose leakage can cause loss of treatment fluid or water, seen as wetness around the skid and inability to maintain normal operation
Service: Check water quality indicators, strainers, dosing points, media condition, pumps, valves, sensors and leak tightness. Confirm the unit changes state correctly between service, regeneration, flushing or standby modes where fitted. For chemical concentration, flow limits or replacement criteria not stated in the source entry, refer to the manufacturer documentation for the exact figure.
Spare Parts: Carry the maker-recommended filter elements or treatment consumables, dosing-pump service parts, seals, hoses, sensor consumables and common electrical fuses.
Use Cases: Applied to potable-water production and conditioning, domestic-water systems and other shipboard water services on merchant, passenger and offshore vessels.
UV Sterilizer 30m3h Evoqua/Xylem Marine unverified
Capacity (m³/h)
30
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Fouling or exhausted treatment media can reduce treatment effectiveness, seen as deteriorating outlet-water quality or rising differential pressure
  • Dosing-pump or chemical-feed faults can interrupt treatment, noticed as unstable readings, low dosing indication or quality alarms
  • Blocked strainers or restricted piping can reduce flow, seen as low throughput or abnormal pump loading
  • Sensor drift or contamination can give incorrect control feedback, noticed as implausible readings or unnecessary alarms
  • Valve, seal or hose leakage can cause loss of treatment fluid or water, seen as wetness around the skid and inability to maintain normal operation
Service: Check water quality indicators, strainers, dosing points, media condition, pumps, valves, sensors and leak tightness. Confirm the unit changes state correctly between service, regeneration, flushing or standby modes where fitted. For chemical concentration, flow limits or replacement criteria not stated in the source entry, refer to the manufacturer documentation for the exact figure.
Spare Parts: Carry the maker-recommended filter elements or treatment consumables, dosing-pump service parts, seals, hoses, sensor consumables and common electrical fuses.
Use Cases: Applied to potable-water production and conditioning, domestic-water systems and other shipboard water services on merchant, passenger and offshore vessels.
UV Sterilizer 50m3h Evoqua/Xylem Marine unverified
Capacity (m³/h)
50
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Fouling or exhausted treatment media can reduce treatment effectiveness, seen as deteriorating outlet-water quality or rising differential pressure
  • Dosing-pump or chemical-feed faults can interrupt treatment, noticed as unstable readings, low dosing indication or quality alarms
  • Blocked strainers or restricted piping can reduce flow, seen as low throughput or abnormal pump loading
  • Sensor drift or contamination can give incorrect control feedback, noticed as implausible readings or unnecessary alarms
  • Valve, seal or hose leakage can cause loss of treatment fluid or water, seen as wetness around the skid and inability to maintain normal operation
Service: Check water quality indicators, strainers, dosing points, media condition, pumps, valves, sensors and leak tightness. Confirm the unit changes state correctly between service, regeneration, flushing or standby modes where fitted. For chemical concentration, flow limits or replacement criteria not stated in the source entry, refer to the manufacturer documentation for the exact figure.
Spare Parts: Carry the maker-recommended filter elements or treatment consumables, dosing-pump service parts, seals, hoses, sensor consumables and common electrical fuses.
Use Cases: Applied to potable-water production and conditioning, domestic-water systems and other shipboard water services on merchant, passenger and offshore vessels.

ENWA Marine

15
UV-1 Marine unverified
Capacity (m³/h)
1
Treatment Type
UV Sterilization
Uv dose mj cm2
40
Common Failures & Inspection Points
  • Lamp ageing or failure reduces UV output and produces lamp or intensity alarms
  • Quartz-sleeve fouling reduces transmitted UV energy and causes low-intensity indication
  • Ballast, power-supply or control faults cause lamp failure or system shutdown
  • Flow above the validated condition or poor water clarity reduces effective disinfection without obvious mechanical failure
  • Seal leakage around quartz sleeves causes water leakage into electrical areas
Service: Inspect lamp status, quartz sleeves, seals, intensity monitor, power supply and flow arrangement. Clean sleeves with approved methods and verify alarm functions. Ensure upstream filtration is maintained. Exact UV dose, lamp replacement and flow criteria require manufacturer documentation.
Spare Parts: Carry UV lamps, quartz sleeves, seals, ballasts or power supplies, fuses and approved cleaning materials.
Use Cases: Potable-water and process-water disinfection on ships and offshore units.
UV-3 Marine unverified
Capacity (m³/h)
3
Treatment Type
UV Sterilization
Uv dose mj cm2
40
Common Failures & Inspection Points
  • Lamp ageing or failure reduces UV output and produces lamp or intensity alarms
  • Quartz-sleeve fouling reduces transmitted UV energy and causes low-intensity indication
  • Ballast, power-supply or control faults cause lamp failure or system shutdown
  • Flow above the validated condition or poor water clarity reduces effective disinfection without obvious mechanical failure
  • Seal leakage around quartz sleeves causes water leakage into electrical areas
Service: Inspect lamp status, quartz sleeves, seals, intensity monitor, power supply and flow arrangement. Clean sleeves with approved methods and verify alarm functions. Ensure upstream filtration is maintained. Exact UV dose, lamp replacement and flow criteria require manufacturer documentation.
Spare Parts: Carry UV lamps, quartz sleeves, seals, ballasts or power supplies, fuses and approved cleaning materials.
Use Cases: Potable-water and process-water disinfection on ships and offshore units.
UV-5 Marine unverified
Capacity (m³/h)
5
Treatment Type
UV Sterilization
Uv dose mj cm2
40
Common Failures & Inspection Points
  • Lamp ageing or failure reduces UV output and produces lamp or intensity alarms
  • Quartz-sleeve fouling reduces transmitted UV energy and causes low-intensity indication
  • Ballast, power-supply or control faults cause lamp failure or system shutdown
  • Flow above the validated condition or poor water clarity reduces effective disinfection without obvious mechanical failure
  • Seal leakage around quartz sleeves causes water leakage into electrical areas
Service: Inspect lamp status, quartz sleeves, seals, intensity monitor, power supply and flow arrangement. Clean sleeves with approved methods and verify alarm functions. Ensure upstream filtration is maintained. Exact UV dose, lamp replacement and flow criteria require manufacturer documentation.
Spare Parts: Carry UV lamps, quartz sleeves, seals, ballasts or power supplies, fuses and approved cleaning materials.
Use Cases: Potable-water and process-water disinfection on ships and offshore units.
UV-10 Marine unverified
Capacity (m³/h)
10
Treatment Type
UV Sterilization
Uv dose mj cm2
40
Common Failures & Inspection Points
  • Fouling or scaling of heat-transfer surfaces, membranes or UV components reduces output or treatment effectiveness
  • Feed-pump wear or restricted strainers reduces flow and causes low-pressure or low-production alarms
  • Seal, hose or piping leakage causes loss of pressure and visible water leakage
  • Sensor or conductivity-monitor faults can reject acceptable product or permit unreliable quality indication
  • Control-valve or electrical faults can interrupt automatic sequencing and stop production
Service: Trend production rate and product-water quality, inspect feed strainers, pumps, valves, seals and the treatment element appropriate to the technology. Clean or replace membranes, heat-transfer surfaces or UV lamps only by approved procedures and verify alarms and automatic diversion or shutdown functions. Exact chemical-cleaning limits, pressures and water-quality criteria must follow manufacturer and vessel documentation.
Spare Parts: Typical spares include prefilter elements, pump seals, O-rings, conductivity or flow-sensor service parts and the technology-specific consumables such as membranes or UV lamps recommended by the manufacturer.
Use Cases: Used on merchant, offshore, passenger and naval vessels to produce or condition freshwater for domestic and technical services.
UV Sterilizer 0.5m3h ENWA Marine unverified
Capacity (m³/h)
0.5
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Reduced treatment or sanitary performance caused by fouled filters, exhausted media, scaled membranes, aged lamps or blocked piping, resulting in poor water quality, low flow or system alarms
  • Dosing, regeneration or vacuum failure caused by empty chemical supply, pump faults, air leakage or control errors, resulting in incorrect water chemistry or poor sanitary operation
  • Sensor or conductivity fault caused by fouling, calibration drift or wiring problems, resulting in implausible readings or alarms
  • Pump or valve failure caused by wear, blockage or electrical faults, resulting in low treatment flow or inability to route water correctly
  • Leakage caused by seal, housing, membrane or piping deterioration, resulting in water loss, vacuum loss or unstable process conditions
Service: Inspect filters, membranes, lamps, dosing equipment, softener vessels, pumps, valves, vacuum equipment, sensors and sample points as applicable to the installed process. Maintain hygienic conditions during opening of potable-water treatment equipment. Trend pressure, vacuum and water-quality indications and investigate abnormal values promptly. Verify alarms, regeneration, diversion, flushing or shutdown functions after maintenance. Store chemicals and treatment media according to approved procedures. Refer to the manufacturer documentation for the exact figure for dosing, replacement, cleaning and operating settings.
Spare Parts: Keep filter elements, membrane or lamp components, approved treatment media, dosing-pump or vacuum-system service parts, seals, valves, sensors and sampling consumables recommended for the installed process. Chemicals must be approved for the intended water service. Confirm exact replacement parts against unit configuration.
Use Cases: Freshwater production, conditioning, disinfection, domestic hot-water and sanitary treatment on merchant ships, passenger vessels and offshore units.
UV Sterilizer 1m3h ENWA Marine unverified
Capacity (m³/h)
1
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Scale, exhausted media or dirty treatment surfaces reduce treatment effectiveness and cause poor water quality
  • Lamp, dosing pump, valve or power-supply faults cause loss of treatment and system alarms
  • Sensor, conductivity or dosing-control faults cause under-treatment, over-treatment or false indication
  • Filter or strainer blockage reduces flow and increases differential pressure
  • Seal, vessel or piping leakage causes water loss and may contaminate the treatment area
Service: Inspect treatment elements, filters, pumps, dosing equipment, sensors, valves and leakage according to the installed process. Trend water-quality results and replace or regenerate treatment media using approved procedures. Keep chemical and UV safety controls intact. Refer to the manufacturer documentation for the exact figure for dose, flow, regeneration and water-quality criteria.
Spare Parts: Carry filters, lamps or treatment media as applicable, pump seals, dosing tubing, sensors, valve parts and approved treatment consumables.
Use Cases: Potable-water disinfection, softening, mineral conditioning and domestic water treatment.
UV Sterilizer 2m3h ENWA Marine unverified
Capacity (m³/h)
2
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Scale, exhausted media or dirty treatment surfaces reduce treatment effectiveness and cause poor water quality
  • Lamp, dosing pump, valve or power-supply faults cause loss of treatment and system alarms
  • Sensor, conductivity or dosing-control faults cause under-treatment, over-treatment or false indication
  • Filter or strainer blockage reduces flow and increases differential pressure
  • Seal, vessel or piping leakage causes water loss and may contaminate the treatment area
Service: Inspect treatment elements, filters, pumps, dosing equipment, sensors, valves and leakage according to the installed process. Trend water-quality results and replace or regenerate treatment media using approved procedures. Keep chemical and UV safety controls intact. Refer to the manufacturer documentation for the exact figure for dose, flow, regeneration and water-quality criteria.
Spare Parts: Carry filters, lamps or treatment media as applicable, pump seals, dosing tubing, sensors, valve parts and approved treatment consumables.
Use Cases: Potable-water disinfection, softening, mineral conditioning and domestic water treatment.
UV Sterilizer 3m3h ENWA Marine unverified
Capacity (m³/h)
3
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Scale, exhausted media or dirty treatment surfaces reduce treatment effectiveness and cause poor water quality
  • Lamp, dosing pump, valve or power-supply faults cause loss of treatment and system alarms
  • Sensor, conductivity or dosing-control faults cause under-treatment, over-treatment or false indication
  • Filter or strainer blockage reduces flow and increases differential pressure
  • Seal, vessel or piping leakage causes water loss and may contaminate the treatment area
Service: Inspect treatment elements, filters, pumps, dosing equipment, sensors, valves and leakage according to the installed process. Trend water-quality results and replace or regenerate treatment media using approved procedures. Keep chemical and UV safety controls intact. Refer to the manufacturer documentation for the exact figure for dose, flow, regeneration and water-quality criteria.
Spare Parts: Carry filters, lamps or treatment media as applicable, pump seals, dosing tubing, sensors, valve parts and approved treatment consumables.
Use Cases: Potable-water disinfection, softening, mineral conditioning and domestic water treatment.
UV Sterilizer 5m3h ENWA Marine unverified
Capacity (m³/h)
5
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Scale, exhausted media or dirty treatment surfaces reduce treatment effectiveness and cause poor water quality
  • Lamp, dosing pump, valve or power-supply faults cause loss of treatment and system alarms
  • Sensor, conductivity or dosing-control faults cause under-treatment, over-treatment or false indication
  • Filter or strainer blockage reduces flow and increases differential pressure
  • Seal, vessel or piping leakage causes water loss and may contaminate the treatment area
Service: Inspect treatment elements, filters, pumps, dosing equipment, sensors, valves and leakage according to the installed process. Trend water-quality results and replace or regenerate treatment media using approved procedures. Keep chemical and UV safety controls intact. Refer to the manufacturer documentation for the exact figure for dose, flow, regeneration and water-quality criteria.
Spare Parts: Carry filters, lamps or treatment media as applicable, pump seals, dosing tubing, sensors, valve parts and approved treatment consumables.
Use Cases: Potable-water disinfection, softening, mineral conditioning and domestic water treatment.
UV Sterilizer 8m3h ENWA Marine unverified
Capacity (m³/h)
8
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Scale, exhausted media or dirty treatment surfaces reduce treatment effectiveness and cause poor water quality
  • Lamp, dosing pump, valve or power-supply faults cause loss of treatment and system alarms
  • Sensor, conductivity or dosing-control faults cause under-treatment, over-treatment or false indication
  • Filter or strainer blockage reduces flow and increases differential pressure
  • Seal, vessel or piping leakage causes water loss and may contaminate the treatment area
Service: Inspect treatment elements, filters, pumps, dosing equipment, sensors, valves and leakage according to the installed process. Trend water-quality results and replace or regenerate treatment media using approved procedures. Keep chemical and UV safety controls intact. Refer to the manufacturer documentation for the exact figure for dose, flow, regeneration and water-quality criteria.
Spare Parts: Carry filters, lamps or treatment media as applicable, pump seals, dosing tubing, sensors, valve parts and approved treatment consumables.
Use Cases: Potable-water disinfection, softening, mineral conditioning and domestic water treatment.
UV Sterilizer 10m3h ENWA Marine unverified
Capacity (m³/h)
10
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Scale, exhausted media or dirty treatment surfaces reduce treatment effectiveness and cause poor water quality
  • Lamp, dosing pump, valve or power-supply faults cause loss of treatment and system alarms
  • Sensor, conductivity or dosing-control faults cause under-treatment, over-treatment or false indication
  • Filter or strainer blockage reduces flow and increases differential pressure
  • Seal, vessel or piping leakage causes water loss and may contaminate the treatment area
Service: Inspect treatment elements, filters, pumps, dosing equipment, sensors, valves and leakage according to the installed process. Trend water-quality results and replace or regenerate treatment media using approved procedures. Keep chemical and UV safety controls intact. Refer to the manufacturer documentation for the exact figure for dose, flow, regeneration and water-quality criteria.
Spare Parts: Carry filters, lamps or treatment media as applicable, pump seals, dosing tubing, sensors, valve parts and approved treatment consumables.
Use Cases: Potable-water disinfection, softening, mineral conditioning and domestic water treatment.
UV Sterilizer 15m3h ENWA Marine unverified
Capacity (m³/h)
15
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Scale, exhausted media or dirty treatment surfaces reduce treatment effectiveness and cause poor water quality
  • Lamp, dosing pump, valve or power-supply faults cause loss of treatment and system alarms
  • Sensor, conductivity or dosing-control faults cause under-treatment, over-treatment or false indication
  • Filter or strainer blockage reduces flow and increases differential pressure
  • Seal, vessel or piping leakage causes water loss and may contaminate the treatment area
Service: Inspect treatment elements, filters, pumps, dosing equipment, sensors, valves and leakage according to the installed process. Trend water-quality results and replace or regenerate treatment media using approved procedures. Keep chemical and UV safety controls intact. Refer to the manufacturer documentation for the exact figure for dose, flow, regeneration and water-quality criteria.
Spare Parts: Carry filters, lamps or treatment media as applicable, pump seals, dosing tubing, sensors, valve parts and approved treatment consumables.
Use Cases: Potable-water disinfection, softening, mineral conditioning and domestic water treatment.
UV Sterilizer 20m3h ENWA Marine unverified
Capacity (m³/h)
20
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Scale, exhausted media or dirty treatment surfaces reduce treatment effectiveness and cause poor water quality
  • Lamp, dosing pump, valve or power-supply faults cause loss of treatment and system alarms
  • Sensor, conductivity or dosing-control faults cause under-treatment, over-treatment or false indication
  • Filter or strainer blockage reduces flow and increases differential pressure
  • Seal, vessel or piping leakage causes water loss and may contaminate the treatment area
Service: Inspect treatment elements, filters, pumps, dosing equipment, sensors, valves and leakage according to the installed process. Trend water-quality results and replace or regenerate treatment media using approved procedures. Keep chemical and UV safety controls intact. Refer to the manufacturer documentation for the exact figure for dose, flow, regeneration and water-quality criteria.
Spare Parts: Carry filters, lamps or treatment media as applicable, pump seals, dosing tubing, sensors, valve parts and approved treatment consumables.
Use Cases: Potable-water disinfection, softening, mineral conditioning and domestic water treatment.
UV Sterilizer 30m3h ENWA Marine unverified
Capacity (m³/h)
30
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Scale, exhausted media or dirty treatment surfaces reduce treatment effectiveness and cause poor water quality
  • Lamp, dosing pump, valve or power-supply faults cause loss of treatment and system alarms
  • Sensor, conductivity or dosing-control faults cause under-treatment, over-treatment or false indication
  • Filter or strainer blockage reduces flow and increases differential pressure
  • Seal, vessel or piping leakage causes water loss and may contaminate the treatment area
Service: Inspect treatment elements, filters, pumps, dosing equipment, sensors, valves and leakage according to the installed process. Trend water-quality results and replace or regenerate treatment media using approved procedures. Keep chemical and UV safety controls intact. Refer to the manufacturer documentation for the exact figure for dose, flow, regeneration and water-quality criteria.
Spare Parts: Carry filters, lamps or treatment media as applicable, pump seals, dosing tubing, sensors, valve parts and approved treatment consumables.
Use Cases: Potable-water disinfection, softening, mineral conditioning and domestic water treatment.
UV Sterilizer 50m3h ENWA Marine unverified
Capacity (m³/h)
50
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Scale, exhausted media or dirty treatment surfaces reduce treatment effectiveness and cause poor water quality
  • Lamp, dosing pump, valve or power-supply faults cause loss of treatment and system alarms
  • Sensor, conductivity or dosing-control faults cause under-treatment, over-treatment or false indication
  • Filter or strainer blockage reduces flow and increases differential pressure
  • Seal, vessel or piping leakage causes water loss and may contaminate the treatment area
Service: Inspect treatment elements, filters, pumps, dosing equipment, sensors, valves and leakage according to the installed process. Trend water-quality results and replace or regenerate treatment media using approved procedures. Keep chemical and UV safety controls intact. Refer to the manufacturer documentation for the exact figure for dose, flow, regeneration and water-quality criteria.
Spare Parts: Carry filters, lamps or treatment media as applicable, pump seals, dosing tubing, sensors, valve parts and approved treatment consumables.
Use Cases: Potable-water disinfection, softening, mineral conditioning and domestic water treatment.

Prominent Marine

15
Dulcodes UV-1 Marine unverified
Capacity (m³/h)
1
Treatment Type
UV Sterilization
Uv dose mj cm2
40
Common Failures & Inspection Points
  • Loss of electrical, hydraulic, pneumatic, fluid, or other service supply from a protection trip, leakage, blockage, or upstream fault results in failed starting or loss of function
  • Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
  • Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
  • Sensor, switch, actuator, relay, or control-system faults cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
  • Incorrect adjustment, assembly, or maintenance leads to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
Service: Inspect the unit for leakage, corrosion, contamination, loose connections, abnormal noise or vibration, condition of guards and mountings, service supplies, controls, alarms, and functional performance. Use maintenance history to identify deterioration trends and refer to manufacturer documentation for exact settings, tolerances, test values, and overhaul criteria.
Spare Parts: Keep the manufacturer-recommended seals and gaskets, filters where fitted, fuses or protection items, common sensors and switches, and critical actuator, control, or wear components appropriate to the installed configuration. Exact part numbers and quantities must come from the manufacturer spare-parts documentation.
Use Cases: Used on vessel types fitted with water treatment equipment, including merchant, offshore, passenger, fishing, or workboat installations where this specific uv sterilizer duty is required.
Dulcodes UV-3 Marine unverified
Capacity (m³/h)
3
Treatment Type
UV Sterilization
Uv dose mj cm2
40
Common Failures & Inspection Points
  • Loss of electrical, hydraulic, pneumatic, fluid, or other service supply from a protection trip, leakage, blockage, or upstream fault results in failed starting or loss of function
  • Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
  • Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
  • Sensor, switch, actuator, relay, or control-system faults cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
  • Incorrect adjustment, assembly, or maintenance leads to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
Service: Inspect the unit for leakage, corrosion, contamination, loose connections, abnormal noise or vibration, condition of guards and mountings, service supplies, controls, alarms, and functional performance. Use maintenance history to identify deterioration trends and refer to manufacturer documentation for exact settings, tolerances, test values, and overhaul criteria.
Spare Parts: Keep the manufacturer-recommended seals and gaskets, filters where fitted, fuses or protection items, common sensors and switches, and critical actuator, control, or wear components appropriate to the installed configuration. Exact part numbers and quantities must come from the manufacturer spare-parts documentation.
Use Cases: Used on vessel types fitted with water treatment equipment, including merchant, offshore, passenger, fishing, or workboat installations where this specific uv sterilizer duty is required.
Dulcodes UV-5 Marine unverified
Capacity (m³/h)
5
Treatment Type
UV Sterilization
Uv dose mj cm2
40
Common Failures & Inspection Points
  • Loss of electrical, hydraulic, pneumatic, fluid, or other service supply from a protection trip, leakage, blockage, or upstream fault results in failed starting or loss of function
  • Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
  • Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
  • Sensor, switch, actuator, relay, or control-system faults cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
  • Incorrect adjustment, assembly, or maintenance leads to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
Service: Inspect the unit for leakage, corrosion, contamination, loose connections, abnormal noise or vibration, condition of guards and mountings, service supplies, controls, alarms, and functional performance. Use maintenance history to identify deterioration trends and refer to manufacturer documentation for exact settings, tolerances, test values, and overhaul criteria.
Spare Parts: Keep the manufacturer-recommended seals and gaskets, filters where fitted, fuses or protection items, common sensors and switches, and critical actuator, control, or wear components appropriate to the installed configuration. Exact part numbers and quantities must come from the manufacturer spare-parts documentation.
Use Cases: Used on vessel types fitted with water treatment equipment, including merchant, offshore, passenger, fishing, or workboat installations where this specific uv sterilizer duty is required.
Dulcodes UV-10 Marine unverified
Capacity (m³/h)
10
Treatment Type
UV Sterilization
Uv dose mj cm2
40
Common Failures & Inspection Points
  • UV lamp/sleeve fouling or lamp failure where applicable, typically indicated by low-UV alarm or inadequate sterilization
  • Dosing pump or chemical-feed blockage, typically indicated by incorrect treatment rate or water-quality deviation
  • Softener resin exhaustion/fouling where applicable, typically indicated by hardness breakthrough or poor regeneration
  • Sensor or flow-switch fault, typically indicated by incorrect dosing/control or alarm
  • Filter/line blockage or scaling, typically indicated by reduced flow or pressure
Service: Inspect treatment vessels, lamps/dosing equipment, filters, sensors, chemical levels and water-quality records; clean and replace consumables under approved procedures and use manufacturer documentation for exact dosing or exposure values.
Spare Parts: Keep UV lamps/sleeves where fitted, dosing-pump kits, filters, seals, sensors and approved treatment consumables.
Use Cases: Used on passenger, cargo, offshore and naval vessels to maintain potable and service-water quality. This entry applies specifically to the UV Sterilizer variant identified as Prominent Marine Dulcodes UV-10 Marine.
UV Sterilizer 0.5m3h Prominent Marine unverified
Capacity (m³/h)
0.5
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Reduced treatment performance caused by fouled filters, exhausted media, scaled membranes, aged lamps or contaminated process surfaces, resulting in poor water quality or increased pressure drop
  • Dosing, regeneration or process-control failure caused by empty consumables, pump faults or control errors, resulting in incorrect treatment conditions
  • Sensor or conductivity fault caused by fouling, calibration drift or wiring problems, resulting in implausible readings or alarms
  • Pump or valve failure caused by wear, blockage or electrical faults, resulting in low treatment flow or inability to route water correctly
  • Leakage caused by seal, housing, membrane, pressure-vessel or piping deterioration, resulting in water loss and unstable process conditions
Service: Inspect filters, membranes, lamps, dosing equipment, treatment vessels, pumps, valves, sensors and sample points as applicable to the installed process. Maintain hygienic conditions during opening of potable-water equipment. Trend pressure drop and water-quality indications and investigate abnormal values promptly. Verify alarms, regeneration, diversion or shutdown functions after maintenance. Store chemicals and treatment media according to approved procedures. Refer to the manufacturer documentation for the exact figure for dosing, replacement, cleaning and water-quality settings.
Spare Parts: Keep filter elements, membrane or lamp components, approved treatment media, dosing-pump service parts, seals, valves, sensors and sampling consumables recommended for the installed process. Chemicals must be approved for the intended water service.
Use Cases: It is used for freshwater, potable-water and sanitary treatment on merchant ships, passenger vessels, offshore units or other vessel types where this equipment category is fitted.
UV Sterilizer 1m3h Prominent Marine unverified
Capacity (m³/h)
1
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Reduced treatment performance caused by fouled filters, exhausted media, scaled membranes, aged lamps or contaminated process surfaces, resulting in poor water quality or increased pressure drop
  • Dosing, regeneration or process-control failure caused by empty consumables, pump faults or control errors, resulting in incorrect treatment conditions
  • Sensor or conductivity fault caused by fouling, calibration drift or wiring problems, resulting in implausible readings or alarms
  • Pump or valve failure caused by wear, blockage or electrical faults, resulting in low treatment flow or inability to route water correctly
  • Leakage caused by seal, housing, membrane, pressure-vessel or piping deterioration, resulting in water loss and unstable process conditions
Service: Inspect filters, membranes, lamps, dosing equipment, treatment vessels, pumps, valves, sensors and sample points as applicable to the installed process. Maintain hygienic conditions during opening of potable-water equipment. Trend pressure drop and water-quality indications and investigate abnormal values promptly. Verify alarms, regeneration, diversion or shutdown functions after maintenance. Store chemicals and treatment media according to approved procedures. Refer to the manufacturer documentation for the exact figure for dosing, replacement, cleaning and water-quality settings.
Spare Parts: Keep filter elements, membrane or lamp components, approved treatment media, dosing-pump service parts, seals, valves, sensors and sampling consumables recommended for the installed process. Chemicals must be approved for the intended water service.
Use Cases: It is used for freshwater, potable-water and sanitary treatment on merchant ships, passenger vessels, offshore units or other vessel types where this equipment category is fitted.
UV Sterilizer 2m3h Prominent Marine unverified
Capacity (m³/h)
2
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Reduced treatment performance caused by fouled filters, exhausted media, scaled membranes, aged lamps or contaminated process surfaces, resulting in poor water quality or increased pressure drop
  • Dosing, regeneration or process-control failure caused by empty consumables, pump faults or control errors, resulting in incorrect treatment conditions
  • Sensor or conductivity fault caused by fouling, calibration drift or wiring problems, resulting in implausible readings or alarms
  • Pump or valve failure caused by wear, blockage or electrical faults, resulting in low treatment flow or inability to route water correctly
  • Leakage caused by seal, housing, membrane, pressure-vessel or piping deterioration, resulting in water loss and unstable process conditions
Service: Inspect filters, membranes, lamps, dosing equipment, treatment vessels, pumps, valves, sensors and sample points as applicable to the installed process. Maintain hygienic conditions during opening of potable-water equipment. Trend pressure drop and water-quality indications and investigate abnormal values promptly. Verify alarms, regeneration, diversion or shutdown functions after maintenance. Store chemicals and treatment media according to approved procedures. Refer to the manufacturer documentation for the exact figure for dosing, replacement, cleaning and water-quality settings.
Spare Parts: Keep filter elements, membrane or lamp components, approved treatment media, dosing-pump service parts, seals, valves, sensors and sampling consumables recommended for the installed process. Chemicals must be approved for the intended water service.
Use Cases: It is used for freshwater, potable-water and sanitary treatment on merchant ships, passenger vessels, offshore units or other vessel types where this equipment category is fitted.
UV Sterilizer 3m3h Prominent Marine unverified
Capacity (m³/h)
3
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Reduced treatment performance caused by fouled filters, exhausted media, scaled membranes, aged lamps or contaminated process surfaces, resulting in poor water quality or increased pressure drop
  • Dosing, regeneration or process-control failure caused by empty consumables, pump faults or control errors, resulting in incorrect treatment conditions
  • Sensor or conductivity fault caused by fouling, calibration drift or wiring problems, resulting in implausible readings or alarms
  • Pump or valve failure caused by wear, blockage or electrical faults, resulting in low treatment flow or inability to route water correctly
  • Leakage caused by seal, housing, membrane, pressure-vessel or piping deterioration, resulting in water loss and unstable process conditions
Service: Inspect filters, membranes, lamps, dosing equipment, treatment vessels, pumps, valves, sensors and sample points as applicable to the installed process. Maintain hygienic conditions during opening of potable-water equipment. Trend pressure drop and water-quality indications and investigate abnormal values promptly. Verify alarms, regeneration, diversion or shutdown functions after maintenance. Store chemicals and treatment media according to approved procedures. Refer to the manufacturer documentation for the exact figure for dosing, replacement, cleaning and water-quality settings.
Spare Parts: Keep filter elements, membrane or lamp components, approved treatment media, dosing-pump service parts, seals, valves, sensors and sampling consumables recommended for the installed process. Chemicals must be approved for the intended water service.
Use Cases: It is used for freshwater, potable-water and sanitary treatment on merchant ships, passenger vessels, offshore units or other vessel types where this equipment category is fitted.
UV Sterilizer 5m3h Prominent Marine unverified
Capacity (m³/h)
5
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Reduced treatment performance caused by fouled filters, exhausted media, scaled membranes, aged lamps or contaminated process surfaces, resulting in poor water quality or increased pressure drop
  • Dosing, regeneration or process-control failure caused by empty consumables, pump faults or control errors, resulting in incorrect treatment conditions
  • Sensor or conductivity fault caused by fouling, calibration drift or wiring problems, resulting in implausible readings or alarms
  • Pump or valve failure caused by wear, blockage or electrical faults, resulting in low treatment flow or inability to route water correctly
  • Leakage caused by seal, housing, membrane, pressure-vessel or piping deterioration, resulting in water loss and unstable process conditions
Service: Inspect filters, membranes, lamps, dosing equipment, treatment vessels, pumps, valves, sensors and sample points as applicable to the installed process. Maintain hygienic conditions during opening of potable-water equipment. Trend pressure drop and water-quality indications and investigate abnormal values promptly. Verify alarms, regeneration, diversion or shutdown functions after maintenance. Store chemicals and treatment media according to approved procedures. Refer to the manufacturer documentation for the exact figure for dosing, replacement, cleaning and water-quality settings.
Spare Parts: Keep filter elements, membrane or lamp components, approved treatment media, dosing-pump service parts, seals, valves, sensors and sampling consumables recommended for the installed process. Chemicals must be approved for the intended water service.
Use Cases: It is used for freshwater, potable-water and sanitary treatment on merchant ships, passenger vessels, offshore units or other vessel types where this equipment category is fitted.
UV Sterilizer 8m3h Prominent Marine unverified
Capacity (m³/h)
8
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Reduced treatment performance caused by fouled filters, exhausted media, scaled membranes, aged lamps or contaminated process surfaces, resulting in poor water quality or increased pressure drop
  • Dosing, regeneration or process-control failure caused by empty consumables, pump faults or control errors, resulting in incorrect treatment conditions
  • Sensor or conductivity fault caused by fouling, calibration drift or wiring problems, resulting in implausible readings or alarms
  • Pump or valve failure caused by wear, blockage or electrical faults, resulting in low treatment flow or inability to route water correctly
  • Leakage caused by seal, housing, membrane, pressure-vessel or piping deterioration, resulting in water loss and unstable process conditions
Service: Inspect filters, membranes, lamps, dosing equipment, treatment vessels, pumps, valves, sensors and sample points as applicable to the installed process. Maintain hygienic conditions during opening of potable-water equipment. Trend pressure drop and water-quality indications and investigate abnormal values promptly. Verify alarms, regeneration, diversion or shutdown functions after maintenance. Store chemicals and treatment media according to approved procedures. Refer to the manufacturer documentation for the exact figure for dosing, replacement, cleaning and water-quality settings.
Spare Parts: Keep filter elements, membrane or lamp components, approved treatment media, dosing-pump service parts, seals, valves, sensors and sampling consumables recommended for the installed process. Chemicals must be approved for the intended water service.
Use Cases: It is used for freshwater, potable-water and sanitary treatment on merchant ships, passenger vessels, offshore units or other vessel types where this equipment category is fitted.
UV Sterilizer 10m3h Prominent Marine unverified
Capacity (m³/h)
10
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Reduced treatment performance caused by fouled filters, exhausted media, scaled membranes, aged lamps or contaminated process surfaces, resulting in poor water quality or increased pressure drop
  • Dosing, regeneration or process-control failure caused by empty consumables, pump faults or control errors, resulting in incorrect treatment conditions
  • Sensor or conductivity fault caused by fouling, calibration drift or wiring problems, resulting in implausible readings or alarms
  • Pump or valve failure caused by wear, blockage or electrical faults, resulting in low treatment flow or inability to route water correctly
  • Leakage caused by seal, housing, membrane, pressure-vessel or piping deterioration, resulting in water loss and unstable process conditions
Service: Inspect filters, membranes, lamps, dosing equipment, treatment vessels, pumps, valves, sensors and sample points as applicable to the installed process. Maintain hygienic conditions during opening of potable-water equipment. Trend pressure drop and water-quality indications and investigate abnormal values promptly. Verify alarms, regeneration, diversion or shutdown functions after maintenance. Store chemicals and treatment media according to approved procedures. Refer to the manufacturer documentation for the exact figure for dosing, replacement, cleaning and water-quality settings.
Spare Parts: Keep filter elements, membrane or lamp components, approved treatment media, dosing-pump service parts, seals, valves, sensors and sampling consumables recommended for the installed process. Chemicals must be approved for the intended water service.
Use Cases: It is used for freshwater, potable-water and sanitary treatment on merchant ships, passenger vessels, offshore units or other vessel types where this equipment category is fitted.
UV Sterilizer 15m3h Prominent Marine unverified
Capacity (m³/h)
15
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Reduced treatment performance caused by fouled filters, exhausted media, scaled membranes, aged lamps or contaminated process surfaces, resulting in poor water quality or increased pressure drop
  • Dosing, regeneration or process-control failure caused by empty consumables, pump faults or control errors, resulting in incorrect treatment conditions
  • Sensor or conductivity fault caused by fouling, calibration drift or wiring problems, resulting in implausible readings or alarms
  • Pump or valve failure caused by wear, blockage or electrical faults, resulting in low treatment flow or inability to route water correctly
  • Leakage caused by seal, housing, membrane, pressure-vessel or piping deterioration, resulting in water loss and unstable process conditions
Service: Inspect filters, membranes, lamps, dosing equipment, treatment vessels, pumps, valves, sensors and sample points as applicable to the installed process. Maintain hygienic conditions during opening of potable-water equipment. Trend pressure drop and water-quality indications and investigate abnormal values promptly. Verify alarms, regeneration, diversion or shutdown functions after maintenance. Store chemicals and treatment media according to approved procedures. Refer to the manufacturer documentation for the exact figure for dosing, replacement, cleaning and water-quality settings.
Spare Parts: Keep filter elements, membrane or lamp components, approved treatment media, dosing-pump service parts, seals, valves, sensors and sampling consumables recommended for the installed process. Chemicals must be approved for the intended water service.
Use Cases: It is used for freshwater, potable-water and sanitary treatment on merchant ships, passenger vessels, offshore units or other vessel types where this equipment category is fitted.
UV Sterilizer 20m3h Prominent Marine unverified
Capacity (m³/h)
20
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Reduced treatment performance caused by fouled filters, exhausted media, scaled membranes, aged lamps or contaminated process surfaces, resulting in poor water quality or increased pressure drop
  • Dosing, regeneration or process-control failure caused by empty consumables, pump faults or control errors, resulting in incorrect treatment conditions
  • Sensor or conductivity fault caused by fouling, calibration drift or wiring problems, resulting in implausible readings or alarms
  • Pump or valve failure caused by wear, blockage or electrical faults, resulting in low treatment flow or inability to route water correctly
  • Leakage caused by seal, housing, membrane, pressure-vessel or piping deterioration, resulting in water loss and unstable process conditions
Service: Inspect filters, membranes, lamps, dosing equipment, treatment vessels, pumps, valves, sensors and sample points as applicable to the installed process. Maintain hygienic conditions during opening of potable-water equipment. Trend pressure drop and water-quality indications and investigate abnormal values promptly. Verify alarms, regeneration, diversion or shutdown functions after maintenance. Store chemicals and treatment media according to approved procedures. Refer to the manufacturer documentation for the exact figure for dosing, replacement, cleaning and water-quality settings.
Spare Parts: Keep filter elements, membrane or lamp components, approved treatment media, dosing-pump service parts, seals, valves, sensors and sampling consumables recommended for the installed process. Chemicals must be approved for the intended water service.
Use Cases: It is used for freshwater, potable-water and sanitary treatment on merchant ships, passenger vessels, offshore units or other vessel types where this equipment category is fitted.
UV Sterilizer 30m3h Prominent Marine unverified
Capacity (m³/h)
30
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Reduced treatment performance caused by fouled filters, exhausted media, scaled membranes, aged lamps or contaminated process surfaces, resulting in poor water quality or increased pressure drop
  • Dosing, regeneration or process-control failure caused by empty consumables, pump faults or control errors, resulting in incorrect treatment conditions
  • Sensor or conductivity fault caused by fouling, calibration drift or wiring problems, resulting in implausible readings or alarms
  • Pump or valve failure caused by wear, blockage or electrical faults, resulting in low treatment flow or inability to route water correctly
  • Leakage caused by seal, housing, membrane, pressure-vessel or piping deterioration, resulting in water loss and unstable process conditions
Service: Inspect filters, membranes, lamps, dosing equipment, treatment vessels, pumps, valves, sensors and sample points as applicable to the installed process. Maintain hygienic conditions during opening of potable-water equipment. Trend pressure drop and water-quality indications and investigate abnormal values promptly. Verify alarms, regeneration, diversion or shutdown functions after maintenance. Store chemicals and treatment media according to approved procedures. Refer to the manufacturer documentation for the exact figure for dosing, replacement, cleaning and water-quality settings.
Spare Parts: Keep filter elements, membrane or lamp components, approved treatment media, dosing-pump service parts, seals, valves, sensors and sampling consumables recommended for the installed process. Chemicals must be approved for the intended water service.
Use Cases: It is used for freshwater, potable-water and sanitary treatment on merchant ships, passenger vessels, offshore units or other vessel types where this equipment category is fitted.
UV Sterilizer 50m3h Prominent Marine unverified
Capacity (m³/h)
50
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Reduced treatment performance caused by fouled filters, exhausted media, scaled membranes, aged lamps or contaminated process surfaces, resulting in poor water quality or increased pressure drop
  • Dosing, regeneration or process-control failure caused by empty consumables, pump faults or control errors, resulting in incorrect treatment conditions
  • Sensor or conductivity fault caused by fouling, calibration drift or wiring problems, resulting in implausible readings or alarms
  • Pump or valve failure caused by wear, blockage or electrical faults, resulting in low treatment flow or inability to route water correctly
  • Leakage caused by seal, housing, membrane, pressure-vessel or piping deterioration, resulting in water loss and unstable process conditions
Service: Inspect filters, membranes, lamps, dosing equipment, treatment vessels, pumps, valves, sensors and sample points as applicable to the installed process. Maintain hygienic conditions during opening of potable-water equipment. Trend pressure drop and water-quality indications and investigate abnormal values promptly. Verify alarms, regeneration, diversion or shutdown functions after maintenance. Store chemicals and treatment media according to approved procedures. Refer to the manufacturer documentation for the exact figure for dosing, replacement, cleaning and water-quality settings.
Spare Parts: Keep filter elements, membrane or lamp components, approved treatment media, dosing-pump service parts, seals, valves, sensors and sampling consumables recommended for the installed process. Chemicals must be approved for the intended water service.
Use Cases: It is used for freshwater, potable-water and sanitary treatment on merchant ships, passenger vessels, offshore units or other vessel types where this equipment category is fitted.

RWO/Veolia

15
RWO/Veolia SanSea UV-1 Marine
SanSea UV-1 Marine unverified
Capacity (m³/h)
1
Treatment Type
UV Sterilization
Uv dose mj cm2
40
Common Failures & Inspection Points
  • Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
  • Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
  • Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
  • Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
  • Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
Service: Inspect the unit for leakage, corrosion, contamination, loose connections, abnormal noise or vibration, condition of guards and mountings, service supplies, controls, alarms, and functional performance. Use the vessel maintenance history to identify deterioration trends and refer to the manufacturer documentation for exact settings, tolerances, test values, and overhaul criteria.
Spare Parts: Keep the manufacturer-recommended seals and gaskets, filters where fitted, fuses or protection items, common sensors and switches, and critical actuator, control, or wear components appropriate to the installed configuration. Exact part numbers and quantities must come from the manufacturer spare-parts documentation.
Use Cases: Used on vessel types fitted with water treatment equipment, including merchant, offshore, passenger, fishing, or workboat installations where this specific uv sterilizer duty is required.
SanSea UV-3 Marine unverified
Capacity (m³/h)
3
Treatment Type
UV Sterilization
Uv dose mj cm2
40
Common Failures & Inspection Points
  • Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
  • Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
  • Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
  • Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
  • Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
Service: Inspect the unit for leakage, corrosion, contamination, loose connections, abnormal noise or vibration, condition of guards and mountings, service supplies, controls, alarms, and functional performance. Use the vessel maintenance history to identify deterioration trends and refer to the manufacturer documentation for exact settings, tolerances, test values, and overhaul criteria.
Spare Parts: Keep the manufacturer-recommended seals and gaskets, filters where fitted, fuses or protection items, common sensors and switches, and critical actuator, control, or wear components appropriate to the installed configuration. Exact part numbers and quantities must come from the manufacturer spare-parts documentation.
Use Cases: Used on vessel types fitted with water treatment equipment, including merchant, offshore, passenger, fishing, or workboat installations where this specific uv sterilizer duty is required.
RWO/Veolia SanSea UV-5 Marine
SanSea UV-5 Marine unverified
Capacity (m³/h)
5
Treatment Type
UV Sterilization
Uv dose mj cm2
40
Common Failures & Inspection Points
  • Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
  • Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
  • Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
  • Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
  • Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
Service: Inspect the unit for leakage, corrosion, contamination, loose connections, abnormal noise or vibration, condition of guards and mountings, service supplies, controls, alarms, and functional performance. Use the vessel maintenance history to identify deterioration trends and refer to the manufacturer documentation for exact settings, tolerances, test values, and overhaul criteria.
Spare Parts: Keep the manufacturer-recommended seals and gaskets, filters where fitted, fuses or protection items, common sensors and switches, and critical actuator, control, or wear components appropriate to the installed configuration. Exact part numbers and quantities must come from the manufacturer spare-parts documentation.
Use Cases: Used on vessel types fitted with water treatment equipment, including merchant, offshore, passenger, fishing, or workboat installations where this specific uv sterilizer duty is required.
SanSea UV-10 Marine unverified
Capacity (m³/h)
10
Treatment Type
UV Sterilization
Uv dose mj cm2
40
Common Failures & Inspection Points
  • Loss of electrical, hydraulic, pneumatic, or other service supply caused by a tripped protection device, leakage, blockage, or upstream fault results in failed starting or loss of function
  • Mechanical wear, corrosion, fouling, or contamination of moving and wetted parts causes increased noise, leakage, sticking, vibration, or reduced performance
  • Seal, gasket, hose, cable, or connection deterioration from age, heat, vibration, or environmental exposure produces visible leakage, intermittent signals, or loss of pressure
  • Sensor, switch, actuator, relay, or control-system faults can cause incorrect indication, nuisance alarms, failed automatic sequences, or loss of remote control
  • Incorrect adjustment, assembly, or maintenance can lead to unstable operation, recurrent alarms, or performance that differs from the vessel's normal baseline
Service: Inspect the unit for leakage, corrosion, contamination, loose connections, abnormal noise or vibration, condition of guards and mountings, service supplies, controls, alarms, and functional performance. Use the vessel maintenance history to identify deterioration trends and refer to the manufacturer documentation for exact settings, tolerances, test values, and overhaul criteria.
Spare Parts: Keep the manufacturer-recommended seals and gaskets, filters where fitted, fuses or protection items, common sensors and switches, and critical actuator, control, or wear components appropriate to the installed configuration. Exact part numbers and quantities must come from the manufacturer spare-parts documentation.
Use Cases: Used on vessel types fitted with water treatment equipment, including merchant, offshore, passenger, fishing, or workboat installations where this specific uv sterilizer duty is required.
UV Sterilizer 0.5m3h RWO/Veolia Marine unverified
Capacity (m³/h)
0.5
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Reduced treatment performance caused by fouled filters, exhausted media, scaled membranes, aged lamps or contaminated process surfaces, resulting in poor water quality or increased pressure drop
  • Dosing, regeneration or process-control failure caused by empty consumables, pump faults or control errors, resulting in incorrect treatment conditions
  • Sensor or conductivity fault caused by fouling, calibration drift or wiring problems, resulting in implausible readings or alarms
  • Pump or valve failure caused by wear, blockage or electrical faults, resulting in low treatment flow or inability to route water correctly
  • Leakage caused by seal, housing, membrane, pressure-vessel or piping deterioration, resulting in water loss and unstable process conditions
Service: Inspect filters, membranes, lamps, dosing equipment, treatment vessels, pumps, valves, sensors and sample points as applicable to the installed process. Maintain hygienic conditions during opening of potable-water equipment. Trend pressure drop and water-quality indications and investigate abnormal values promptly. Verify alarms, regeneration, diversion or shutdown functions after maintenance. Store chemicals and treatment media according to approved procedures. Refer to the manufacturer documentation for the exact figure for dosing, replacement, cleaning and water-quality settings.
Spare Parts: Keep filter elements, membrane or lamp components, approved treatment media, dosing-pump service parts, seals, valves, sensors and sampling consumables recommended for the installed process. Chemicals must be approved for the intended water service.
Use Cases: It is used for freshwater, potable-water and sanitary treatment on merchant ships, passenger vessels, offshore units or other vessel types where this equipment category is fitted.
UV Sterilizer 1m3h RWO/Veolia Marine unverified
Capacity (m³/h)
1
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Reduced treatment or sanitary performance caused by fouled filters, exhausted media, scaled membranes, aged lamps or blocked piping, resulting in poor water quality, low flow or system alarms
  • Dosing, regeneration or vacuum failure caused by empty chemical supply, pump faults, air leakage or control errors, resulting in incorrect water chemistry or poor sanitary operation
  • Sensor or conductivity fault caused by fouling, calibration drift or wiring problems, resulting in implausible readings or alarms
  • Pump or valve failure caused by wear, blockage or electrical faults, resulting in low treatment flow or inability to route water correctly
  • Leakage caused by seal, housing, membrane or piping deterioration, resulting in water loss, vacuum loss or unstable process conditions
Service: Inspect filters, membranes, lamps, dosing equipment, softener vessels, pumps, valves, vacuum equipment, sensors and sample points as applicable to the installed process. Maintain hygienic conditions during opening of potable-water treatment equipment. Trend pressure, vacuum and water-quality indications and investigate abnormal values promptly. Verify alarms, regeneration, diversion, flushing or shutdown functions after maintenance. Store chemicals and treatment media according to approved procedures. Refer to the manufacturer documentation for the exact figure for dosing, replacement, cleaning and operating settings.
Spare Parts: Keep filter elements, membrane or lamp components, approved treatment media, dosing-pump or vacuum-system service parts, seals, valves, sensors and sampling consumables recommended for the installed process. Chemicals must be approved for the intended water service. Confirm exact replacement parts against unit configuration.
Use Cases: Freshwater production, conditioning, disinfection, domestic hot-water and sanitary treatment on merchant ships, passenger vessels and offshore units.
UV Sterilizer 2m3h RWO/Veolia Marine unverified
Capacity (m³/h)
2
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Reduced treatment or sanitary performance caused by fouled filters, exhausted media, scaled membranes, aged lamps or blocked piping, resulting in poor water quality, low flow or system alarms
  • Dosing, regeneration or vacuum failure caused by empty chemical supply, pump faults, air leakage or control errors, resulting in incorrect water chemistry or poor sanitary operation
  • Sensor or conductivity fault caused by fouling, calibration drift or wiring problems, resulting in implausible readings or alarms
  • Pump or valve failure caused by wear, blockage or electrical faults, resulting in low treatment flow or inability to route water correctly
  • Leakage caused by seal, housing, membrane or piping deterioration, resulting in water loss, vacuum loss or unstable process conditions
Service: Inspect filters, membranes, lamps, dosing equipment, softener vessels, pumps, valves, vacuum equipment, sensors and sample points as applicable to the installed process. Maintain hygienic conditions during opening of potable-water treatment equipment. Trend pressure, vacuum and water-quality indications and investigate abnormal values promptly. Verify alarms, regeneration, diversion, flushing or shutdown functions after maintenance. Store chemicals and treatment media according to approved procedures. Refer to the manufacturer documentation for the exact figure for dosing, replacement, cleaning and operating settings.
Spare Parts: Keep filter elements, membrane or lamp components, approved treatment media, dosing-pump or vacuum-system service parts, seals, valves, sensors and sampling consumables recommended for the installed process. Chemicals must be approved for the intended water service. Confirm exact replacement parts against unit configuration.
Use Cases: Freshwater production, conditioning, disinfection, domestic hot-water and sanitary treatment on merchant ships, passenger vessels and offshore units.
UV Sterilizer 3m3h RWO/Veolia Marine unverified
Capacity (m³/h)
3
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Reduced treatment or sanitary performance caused by fouled filters, exhausted media, scaled membranes, aged lamps or blocked piping, resulting in poor water quality, low flow or system alarms
  • Dosing, regeneration or vacuum failure caused by empty chemical supply, pump faults, air leakage or control errors, resulting in incorrect water chemistry or poor sanitary operation
  • Sensor or conductivity fault caused by fouling, calibration drift or wiring problems, resulting in implausible readings or alarms
  • Pump or valve failure caused by wear, blockage or electrical faults, resulting in low treatment flow or inability to route water correctly
  • Leakage caused by seal, housing, membrane or piping deterioration, resulting in water loss, vacuum loss or unstable process conditions
Service: Inspect filters, membranes, lamps, dosing equipment, softener vessels, pumps, valves, vacuum equipment, sensors and sample points as applicable to the installed process. Maintain hygienic conditions during opening of potable-water treatment equipment. Trend pressure, vacuum and water-quality indications and investigate abnormal values promptly. Verify alarms, regeneration, diversion, flushing or shutdown functions after maintenance. Store chemicals and treatment media according to approved procedures. Refer to the manufacturer documentation for the exact figure for dosing, replacement, cleaning and operating settings.
Spare Parts: Keep filter elements, membrane or lamp components, approved treatment media, dosing-pump or vacuum-system service parts, seals, valves, sensors and sampling consumables recommended for the installed process. Chemicals must be approved for the intended water service. Confirm exact replacement parts against unit configuration.
Use Cases: Freshwater production, conditioning, disinfection, domestic hot-water and sanitary treatment on merchant ships, passenger vessels and offshore units.
UV Sterilizer 5m3h RWO/Veolia Marine unverified
Capacity (m³/h)
5
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Reduced treatment or sanitary performance caused by fouled filters, exhausted media, scaled membranes, aged lamps or blocked piping, resulting in poor water quality, low flow or system alarms
  • Dosing, regeneration or vacuum failure caused by empty chemical supply, pump faults, air leakage or control errors, resulting in incorrect water chemistry or poor sanitary operation
  • Sensor or conductivity fault caused by fouling, calibration drift or wiring problems, resulting in implausible readings or alarms
  • Pump or valve failure caused by wear, blockage or electrical faults, resulting in low treatment flow or inability to route water correctly
  • Leakage caused by seal, housing, membrane or piping deterioration, resulting in water loss, vacuum loss or unstable process conditions
Service: Inspect filters, membranes, lamps, dosing equipment, softener vessels, pumps, valves, vacuum equipment, sensors and sample points as applicable to the installed process. Maintain hygienic conditions during opening of potable-water treatment equipment. Trend pressure, vacuum and water-quality indications and investigate abnormal values promptly. Verify alarms, regeneration, diversion, flushing or shutdown functions after maintenance. Store chemicals and treatment media according to approved procedures. Refer to the manufacturer documentation for the exact figure for dosing, replacement, cleaning and operating settings.
Spare Parts: Keep filter elements, membrane or lamp components, approved treatment media, dosing-pump or vacuum-system service parts, seals, valves, sensors and sampling consumables recommended for the installed process. Chemicals must be approved for the intended water service. Confirm exact replacement parts against unit configuration.
Use Cases: Freshwater production, conditioning, disinfection, domestic hot-water and sanitary treatment on merchant ships, passenger vessels and offshore units.
UV Sterilizer 8m3h RWO/Veolia Marine unverified
Capacity (m³/h)
8
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Reduced treatment or sanitary performance caused by fouled filters, exhausted media, scaled membranes, aged lamps or blocked piping, resulting in poor water quality, low flow or system alarms
  • Dosing, regeneration or vacuum failure caused by empty chemical supply, pump faults, air leakage or control errors, resulting in incorrect water chemistry or poor sanitary operation
  • Sensor or conductivity fault caused by fouling, calibration drift or wiring problems, resulting in implausible readings or alarms
  • Pump or valve failure caused by wear, blockage or electrical faults, resulting in low treatment flow or inability to route water correctly
  • Leakage caused by seal, housing, membrane or piping deterioration, resulting in water loss, vacuum loss or unstable process conditions
Service: Inspect filters, membranes, lamps, dosing equipment, softener vessels, pumps, valves, vacuum equipment, sensors and sample points as applicable to the installed process. Maintain hygienic conditions during opening of potable-water treatment equipment. Trend pressure, vacuum and water-quality indications and investigate abnormal values promptly. Verify alarms, regeneration, diversion, flushing or shutdown functions after maintenance. Store chemicals and treatment media according to approved procedures. Refer to the manufacturer documentation for the exact figure for dosing, replacement, cleaning and operating settings.
Spare Parts: Keep filter elements, membrane or lamp components, approved treatment media, dosing-pump or vacuum-system service parts, seals, valves, sensors and sampling consumables recommended for the installed process. Chemicals must be approved for the intended water service. Confirm exact replacement parts against unit configuration.
Use Cases: Freshwater production, conditioning, disinfection, domestic hot-water and sanitary treatment on merchant ships, passenger vessels and offshore units.
UV Sterilizer 10m3h RWO/Veolia Marine unverified
Capacity (m³/h)
10
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Reduced treatment performance caused by fouled filters, exhausted media, scaled membranes, aged lamps or contaminated process surfaces, resulting in poor water quality or increased pressure drop
  • Dosing, regeneration or process-control failure caused by empty consumables, pump faults or control errors, resulting in incorrect treatment conditions
  • Sensor or conductivity fault caused by fouling, calibration drift or wiring problems, resulting in implausible readings or alarms
  • Pump or valve failure caused by wear, blockage or electrical faults, resulting in low treatment flow or inability to route water correctly
  • Leakage caused by seal, housing, membrane, pressure-vessel or piping deterioration, resulting in water loss and unstable process conditions
Service: Inspect filters, membranes, lamps, dosing equipment, treatment vessels, pumps, valves, sensors and sample points as applicable to the installed process. Maintain hygienic conditions during opening of potable-water equipment. Trend pressure drop and water-quality indications and investigate abnormal values promptly. Verify alarms, regeneration, diversion or shutdown functions after maintenance. Store chemicals and treatment media according to approved procedures. Refer to the manufacturer documentation for the exact figure for dosing, replacement, cleaning and water-quality settings.
Spare Parts: Keep filter elements, membrane or lamp components, approved treatment media, dosing-pump service parts, seals, valves, sensors and sampling consumables recommended for the installed process. Chemicals must be approved for the intended water service.
Use Cases: It is used for freshwater, potable-water and sanitary treatment on merchant ships, passenger vessels, offshore units or other vessel types where this equipment category is fitted.
UV Sterilizer 15m3h RWO/Veolia Marine unverified
Capacity (m³/h)
15
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Reduced treatment performance caused by fouled filters, exhausted media, scaled membranes, aged lamps or contaminated process surfaces, resulting in poor water quality or increased pressure drop
  • Dosing, regeneration or process-control failure caused by empty consumables, pump faults or control errors, resulting in incorrect treatment conditions
  • Sensor or conductivity fault caused by fouling, calibration drift or wiring problems, resulting in implausible readings or alarms
  • Pump or valve failure caused by wear, blockage or electrical faults, resulting in low treatment flow or inability to route water correctly
  • Leakage caused by seal, housing, membrane, pressure-vessel or piping deterioration, resulting in water loss and unstable process conditions
Service: Inspect filters, membranes, lamps, dosing equipment, treatment vessels, pumps, valves, sensors and sample points as applicable to the installed process. Maintain hygienic conditions during opening of potable-water equipment. Trend pressure drop and water-quality indications and investigate abnormal values promptly. Verify alarms, regeneration, diversion or shutdown functions after maintenance. Store chemicals and treatment media according to approved procedures. Refer to the manufacturer documentation for the exact figure for dosing, replacement, cleaning and water-quality settings.
Spare Parts: Keep filter elements, membrane or lamp components, approved treatment media, dosing-pump service parts, seals, valves, sensors and sampling consumables recommended for the installed process. Chemicals must be approved for the intended water service.
Use Cases: It is used for freshwater, potable-water and sanitary treatment on merchant ships, passenger vessels, offshore units or other vessel types where this equipment category is fitted.
UV Sterilizer 20m3h RWO/Veolia Marine unverified
Capacity (m³/h)
20
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Reduced treatment performance caused by fouled filters, exhausted media, scaled membranes, aged lamps or contaminated process surfaces, resulting in poor water quality or increased pressure drop
  • Dosing, regeneration or process-control failure caused by empty consumables, pump faults or control errors, resulting in incorrect treatment conditions
  • Sensor or conductivity fault caused by fouling, calibration drift or wiring problems, resulting in implausible readings or alarms
  • Pump or valve failure caused by wear, blockage or electrical faults, resulting in low treatment flow or inability to route water correctly
  • Leakage caused by seal, housing, membrane, pressure-vessel or piping deterioration, resulting in water loss and unstable process conditions
Service: Inspect filters, membranes, lamps, dosing equipment, treatment vessels, pumps, valves, sensors and sample points as applicable to the installed process. Maintain hygienic conditions during opening of potable-water equipment. Trend pressure drop and water-quality indications and investigate abnormal values promptly. Verify alarms, regeneration, diversion or shutdown functions after maintenance. Store chemicals and treatment media according to approved procedures. Refer to the manufacturer documentation for the exact figure for dosing, replacement, cleaning and water-quality settings.
Spare Parts: Keep filter elements, membrane or lamp components, approved treatment media, dosing-pump service parts, seals, valves, sensors and sampling consumables recommended for the installed process. Chemicals must be approved for the intended water service.
Use Cases: It is used for freshwater, potable-water and sanitary treatment on merchant ships, passenger vessels, offshore units or other vessel types where this equipment category is fitted.
UV Sterilizer 30m3h RWO/Veolia Marine unverified
Capacity (m³/h)
30
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Reduced treatment performance caused by fouled filters, exhausted media, scaled membranes, aged lamps or contaminated process surfaces, resulting in poor water quality or increased pressure drop
  • Dosing, regeneration or process-control failure caused by empty consumables, pump faults or control errors, resulting in incorrect treatment conditions
  • Sensor or conductivity fault caused by fouling, calibration drift or wiring problems, resulting in implausible readings or alarms
  • Pump or valve failure caused by wear, blockage or electrical faults, resulting in low treatment flow or inability to route water correctly
  • Leakage caused by seal, housing, membrane, pressure-vessel or piping deterioration, resulting in water loss and unstable process conditions
Service: Inspect filters, membranes, lamps, dosing equipment, treatment vessels, pumps, valves, sensors and sample points as applicable to the installed process. Maintain hygienic conditions during opening of potable-water equipment. Trend pressure drop and water-quality indications and investigate abnormal values promptly. Verify alarms, regeneration, diversion or shutdown functions after maintenance. Store chemicals and treatment media according to approved procedures. Refer to the manufacturer documentation for the exact figure for dosing, replacement, cleaning and water-quality settings.
Spare Parts: Keep filter elements, membrane or lamp components, approved treatment media, dosing-pump service parts, seals, valves, sensors and sampling consumables recommended for the installed process. Chemicals must be approved for the intended water service.
Use Cases: It is used for freshwater, potable-water and sanitary treatment on merchant ships, passenger vessels, offshore units or other vessel types where this equipment category is fitted.
UV Sterilizer 50m3h RWO/Veolia Marine unverified
Capacity (m³/h)
50
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Reduced treatment performance caused by fouled filters, exhausted media, scaled membranes, aged lamps or contaminated process surfaces, resulting in poor water quality or increased pressure drop
  • Dosing, regeneration or process-control failure caused by empty consumables, pump faults or control errors, resulting in incorrect treatment conditions
  • Sensor or conductivity fault caused by fouling, calibration drift or wiring problems, resulting in implausible readings or alarms
  • Pump or valve failure caused by wear, blockage or electrical faults, resulting in low treatment flow or inability to route water correctly
  • Leakage caused by seal, housing, membrane, pressure-vessel or piping deterioration, resulting in water loss and unstable process conditions
Service: Inspect filters, membranes, lamps, dosing equipment, treatment vessels, pumps, valves, sensors and sample points as applicable to the installed process. Maintain hygienic conditions during opening of potable-water equipment. Trend pressure drop and water-quality indications and investigate abnormal values promptly. Verify alarms, regeneration, diversion or shutdown functions after maintenance. Store chemicals and treatment media according to approved procedures. Refer to the manufacturer documentation for the exact figure for dosing, replacement, cleaning and water-quality settings.
Spare Parts: Keep filter elements, membrane or lamp components, approved treatment media, dosing-pump service parts, seals, valves, sensors and sampling consumables recommended for the installed process. Chemicals must be approved for the intended water service.
Use Cases: It is used for freshwater, potable-water and sanitary treatment on merchant ships, passenger vessels, offshore units or other vessel types where this equipment category is fitted.

BWT Marine

11
UV Sterilizer 0.5m3h BWT Marine unverified
Capacity (m³/h)
0.5
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Scale, exhausted media or dirty treatment surfaces reduce treatment effectiveness and cause poor water quality
  • Lamp, dosing pump, valve or power-supply faults cause loss of treatment and system alarms
  • Sensor, conductivity or dosing-control faults cause under-treatment, over-treatment or false indication
  • Filter or strainer blockage reduces flow and increases differential pressure
  • Seal, vessel or piping leakage causes water loss and may contaminate the treatment area
Service: Inspect treatment elements, filters, pumps, dosing equipment, sensors, valves and leakage according to the installed process. Trend water-quality results and replace or regenerate treatment media using approved procedures. Keep chemical and UV safety controls intact. Refer to the manufacturer documentation for the exact figure for dose, flow, regeneration and water-quality criteria.
Spare Parts: Carry filters, lamps or treatment media as applicable, pump seals, dosing tubing, sensors, valve parts and approved treatment consumables.
Use Cases: Potable-water disinfection, softening, mineral conditioning and domestic water treatment.
UV Sterilizer 1m3h BWT Marine unverified
Capacity (m³/h)
1
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • UV lamp/sleeve fouling or lamp failure where applicable, typically indicated by low-UV alarm or inadequate sterilization
  • Dosing pump or chemical-feed blockage, typically indicated by incorrect treatment rate or water-quality deviation
  • Softener resin exhaustion/fouling where applicable, typically indicated by hardness breakthrough or poor regeneration
  • Sensor or flow-switch fault, typically indicated by incorrect dosing/control or alarm
  • Filter/line blockage or scaling, typically indicated by reduced flow or pressure
Service: Inspect treatment vessels, lamps/dosing equipment, filters, sensors, chemical levels and water-quality records; clean and replace consumables under approved procedures and use manufacturer documentation for exact dosing or exposure values.
Spare Parts: Keep UV lamps/sleeves where fitted, dosing-pump kits, filters, seals, sensors and approved treatment consumables.
Use Cases: Used on passenger, cargo, offshore and naval vessels to maintain potable and service-water quality. This entry applies specifically to the UV Sterilizer variant identified as BWT Marine UV Sterilizer 1m3h BWT Marine.
UV Sterilizer 2m3h BWT Marine unverified
Capacity (m³/h)
2
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • UV lamp/sleeve fouling or lamp failure where applicable, typically indicated by low-UV alarm or inadequate sterilization
  • Dosing pump or chemical-feed blockage, typically indicated by incorrect treatment rate or water-quality deviation
  • Softener resin exhaustion/fouling where applicable, typically indicated by hardness breakthrough or poor regeneration
  • Sensor or flow-switch fault, typically indicated by incorrect dosing/control or alarm
  • Filter/line blockage or scaling, typically indicated by reduced flow or pressure
Service: Inspect treatment vessels, lamps/dosing equipment, filters, sensors, chemical levels and water-quality records; clean and replace consumables under approved procedures and use manufacturer documentation for exact dosing or exposure values.
Spare Parts: Keep UV lamps/sleeves where fitted, dosing-pump kits, filters, seals, sensors and approved treatment consumables.
Use Cases: Used on passenger, cargo, offshore and naval vessels to maintain potable and service-water quality. This entry applies specifically to the UV Sterilizer variant identified as BWT Marine UV Sterilizer 2m3h BWT Marine.
UV Sterilizer 3m3h BWT Marine unverified
Capacity (m³/h)
3
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • UV lamp/sleeve fouling or lamp failure where applicable, typically indicated by low-UV alarm or inadequate sterilization
  • Dosing pump or chemical-feed blockage, typically indicated by incorrect treatment rate or water-quality deviation
  • Softener resin exhaustion/fouling where applicable, typically indicated by hardness breakthrough or poor regeneration
  • Sensor or flow-switch fault, typically indicated by incorrect dosing/control or alarm
  • Filter/line blockage or scaling, typically indicated by reduced flow or pressure
Service: Inspect treatment vessels, lamps/dosing equipment, filters, sensors, chemical levels and water-quality records; clean and replace consumables under approved procedures and use manufacturer documentation for exact dosing or exposure values.
Spare Parts: Keep UV lamps/sleeves where fitted, dosing-pump kits, filters, seals, sensors and approved treatment consumables.
Use Cases: Used on passenger, cargo, offshore and naval vessels to maintain potable and service-water quality. This entry applies specifically to the UV Sterilizer variant identified as BWT Marine UV Sterilizer 3m3h BWT Marine.
UV Sterilizer 5m3h BWT Marine unverified
Capacity (m³/h)
5
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • UV lamp/sleeve fouling or lamp failure where applicable, typically indicated by low-UV alarm or inadequate sterilization
  • Dosing pump or chemical-feed blockage, typically indicated by incorrect treatment rate or water-quality deviation
  • Softener resin exhaustion/fouling where applicable, typically indicated by hardness breakthrough or poor regeneration
  • Sensor or flow-switch fault, typically indicated by incorrect dosing/control or alarm
  • Filter/line blockage or scaling, typically indicated by reduced flow or pressure
Service: Inspect treatment vessels, lamps/dosing equipment, filters, sensors, chemical levels and water-quality records; clean and replace consumables under approved procedures and use manufacturer documentation for exact dosing or exposure values.
Spare Parts: Keep UV lamps/sleeves where fitted, dosing-pump kits, filters, seals, sensors and approved treatment consumables.
Use Cases: Used on passenger, cargo, offshore and naval vessels to maintain potable and service-water quality. This entry applies specifically to the UV Sterilizer variant identified as BWT Marine UV Sterilizer 5m3h BWT Marine.
UV Sterilizer 8m3h BWT Marine unverified
Capacity (m³/h)
8
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • UV lamp/sleeve fouling or lamp failure where applicable, typically indicated by low-UV alarm or inadequate sterilization
  • Dosing pump or chemical-feed blockage, typically indicated by incorrect treatment rate or water-quality deviation
  • Softener resin exhaustion/fouling where applicable, typically indicated by hardness breakthrough or poor regeneration
  • Sensor or flow-switch fault, typically indicated by incorrect dosing/control or alarm
  • Filter/line blockage or scaling, typically indicated by reduced flow or pressure
Service: Inspect treatment vessels, lamps/dosing equipment, filters, sensors, chemical levels and water-quality records; clean and replace consumables under approved procedures and use manufacturer documentation for exact dosing or exposure values.
Spare Parts: Keep UV lamps/sleeves where fitted, dosing-pump kits, filters, seals, sensors and approved treatment consumables.
Use Cases: Used on passenger, cargo, offshore and naval vessels to maintain potable and service-water quality. This entry applies specifically to the UV Sterilizer variant identified as BWT Marine UV Sterilizer 8m3h BWT Marine.
UV Sterilizer 10m3h BWT Marine unverified
Capacity (m³/h)
10
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Scale, exhausted media or dirty treatment surfaces reduce treatment effectiveness and cause poor water quality
  • Lamp, dosing pump, valve or power-supply faults cause loss of treatment and system alarms
  • Sensor, conductivity or dosing-control faults cause under-treatment, over-treatment or false indication
  • Filter or strainer blockage reduces flow and increases differential pressure
  • Seal, vessel or piping leakage causes water loss and may contaminate the treatment area
Service: Inspect treatment elements, filters, pumps, dosing equipment, sensors, valves and leakage according to the installed process. Trend water-quality results and replace or regenerate treatment media using approved procedures. Keep chemical and UV safety controls intact. Refer to the manufacturer documentation for the exact figure for dose, flow, regeneration and water-quality criteria.
Spare Parts: Carry filters, lamps or treatment media as applicable, pump seals, dosing tubing, sensors, valve parts and approved treatment consumables.
Use Cases: Potable-water disinfection, softening, mineral conditioning and domestic water treatment.
UV Sterilizer 15m3h BWT Marine unverified
Capacity (m³/h)
15
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Scale, exhausted media or dirty treatment surfaces reduce treatment effectiveness and cause poor water quality
  • Lamp, dosing pump, valve or power-supply faults cause loss of treatment and system alarms
  • Sensor, conductivity or dosing-control faults cause under-treatment, over-treatment or false indication
  • Filter or strainer blockage reduces flow and increases differential pressure
  • Seal, vessel or piping leakage causes water loss and may contaminate the treatment area
Service: Inspect treatment elements, filters, pumps, dosing equipment, sensors, valves and leakage according to the installed process. Trend water-quality results and replace or regenerate treatment media using approved procedures. Keep chemical and UV safety controls intact. Refer to the manufacturer documentation for the exact figure for dose, flow, regeneration and water-quality criteria.
Spare Parts: Carry filters, lamps or treatment media as applicable, pump seals, dosing tubing, sensors, valve parts and approved treatment consumables.
Use Cases: Potable-water disinfection, softening, mineral conditioning and domestic water treatment.
UV Sterilizer 20m3h BWT Marine unverified
Capacity (m³/h)
20
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Scale, exhausted media or dirty treatment surfaces reduce treatment effectiveness and cause poor water quality
  • Lamp, dosing pump, valve or power-supply faults cause loss of treatment and system alarms
  • Sensor, conductivity or dosing-control faults cause under-treatment, over-treatment or false indication
  • Filter or strainer blockage reduces flow and increases differential pressure
  • Seal, vessel or piping leakage causes water loss and may contaminate the treatment area
Service: Inspect treatment elements, filters, pumps, dosing equipment, sensors, valves and leakage according to the installed process. Trend water-quality results and replace or regenerate treatment media using approved procedures. Keep chemical and UV safety controls intact. Refer to the manufacturer documentation for the exact figure for dose, flow, regeneration and water-quality criteria.
Spare Parts: Carry filters, lamps or treatment media as applicable, pump seals, dosing tubing, sensors, valve parts and approved treatment consumables.
Use Cases: Potable-water disinfection, softening, mineral conditioning and domestic water treatment.
UV Sterilizer 30m3h BWT Marine unverified
Capacity (m³/h)
30
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Scale, exhausted media or dirty treatment surfaces reduce treatment effectiveness and cause poor water quality
  • Lamp, dosing pump, valve or power-supply faults cause loss of treatment and system alarms
  • Sensor, conductivity or dosing-control faults cause under-treatment, over-treatment or false indication
  • Filter or strainer blockage reduces flow and increases differential pressure
  • Seal, vessel or piping leakage causes water loss and may contaminate the treatment area
Service: Inspect treatment elements, filters, pumps, dosing equipment, sensors, valves and leakage according to the installed process. Trend water-quality results and replace or regenerate treatment media using approved procedures. Keep chemical and UV safety controls intact. Refer to the manufacturer documentation for the exact figure for dose, flow, regeneration and water-quality criteria.
Spare Parts: Carry filters, lamps or treatment media as applicable, pump seals, dosing tubing, sensors, valve parts and approved treatment consumables.
Use Cases: Potable-water disinfection, softening, mineral conditioning and domestic water treatment.
UV Sterilizer 50m3h BWT Marine unverified
Capacity (m³/h)
50
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Scale, exhausted media or dirty treatment surfaces reduce treatment effectiveness and cause poor water quality
  • Lamp, dosing pump, valve or power-supply faults cause loss of treatment and system alarms
  • Sensor, conductivity or dosing-control faults cause under-treatment, over-treatment or false indication
  • Filter or strainer blockage reduces flow and increases differential pressure
  • Seal, vessel or piping leakage causes water loss and may contaminate the treatment area
Service: Inspect treatment elements, filters, pumps, dosing equipment, sensors, valves and leakage according to the installed process. Trend water-quality results and replace or regenerate treatment media using approved procedures. Keep chemical and UV safety controls intact. Refer to the manufacturer documentation for the exact figure for dose, flow, regeneration and water-quality criteria.
Spare Parts: Carry filters, lamps or treatment media as applicable, pump seals, dosing tubing, sensors, valve parts and approved treatment consumables.
Use Cases: Potable-water disinfection, softening, mineral conditioning and domestic water treatment.

Lutz-Jesco Marine

11
UV Sterilizer 0.5m3h Lutz-Jesco Marine unverified
Capacity (m³/h)
0.5
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Fouling or exhausted treatment media can reduce treatment effectiveness, seen as deteriorating outlet-water quality or rising differential pressure
  • Dosing-pump or chemical-feed faults can interrupt treatment, noticed as unstable readings, low dosing indication or quality alarms
  • Blocked strainers or restricted piping can reduce flow, seen as low throughput or abnormal pump loading
  • Sensor drift or contamination can give incorrect control feedback, noticed as implausible readings or unnecessary alarms
  • Valve, seal or hose leakage can cause loss of treatment fluid or water, seen as wetness around the skid and inability to maintain normal operation
Service: Check water quality indicators, strainers, dosing points, media condition, pumps, valves, sensors and leak tightness. Confirm the unit changes state correctly between service, regeneration, flushing or standby modes where fitted. For chemical concentration, flow limits or replacement criteria not stated in the source entry, refer to the manufacturer documentation for the exact figure.
Spare Parts: Carry the maker-recommended filter elements or treatment consumables, dosing-pump service parts, seals, hoses, sensor consumables and common electrical fuses.
Use Cases: Applied to potable-water production and conditioning, domestic-water systems and other shipboard water services on merchant, passenger and offshore vessels.
UV Sterilizer 1m3h Lutz-Jesco Marine unverified
Capacity (m³/h)
1
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Reduced treatment performance caused by fouled filters, exhausted media, scaled membranes, aged lamps or contaminated process surfaces, resulting in poor water quality or increased pressure drop
  • Dosing, regeneration or process-control failure caused by empty consumables, pump faults or control errors, resulting in incorrect treatment conditions
  • Sensor or conductivity fault caused by fouling, calibration drift or wiring problems, resulting in implausible readings or alarms
  • Pump or valve failure caused by wear, blockage or electrical faults, resulting in low treatment flow or inability to route water correctly
  • Leakage caused by seal, housing, membrane, pressure-vessel or piping deterioration, resulting in water loss and unstable process conditions
Service: Inspect filters, membranes, lamps, dosing equipment, treatment vessels, pumps, valves, sensors and sample points as applicable to the installed process. Maintain hygienic conditions during opening of potable-water equipment. Trend pressure drop and water-quality indications and investigate abnormal values promptly. Verify alarms, regeneration, diversion or shutdown functions after maintenance. Store chemicals and treatment media according to approved procedures. Refer to the manufacturer documentation for the exact figure for dosing, replacement, cleaning and water-quality settings.
Spare Parts: Keep filter elements, membrane or lamp components, approved treatment media, dosing-pump service parts, seals, valves, sensors and sampling consumables recommended for the installed process. Chemicals must be approved for the intended water service.
Use Cases: It is used for freshwater, potable-water and sanitary treatment on merchant ships, passenger vessels, offshore units or other vessel types where this equipment category is fitted.
UV Sterilizer 2m3h Lutz-Jesco Marine unverified
Capacity (m³/h)
2
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Reduced treatment performance caused by fouled filters, exhausted media, scaled membranes, aged lamps or contaminated process surfaces, resulting in poor water quality or increased pressure drop
  • Dosing, regeneration or process-control failure caused by empty consumables, pump faults or control errors, resulting in incorrect treatment conditions
  • Sensor or conductivity fault caused by fouling, calibration drift or wiring problems, resulting in implausible readings or alarms
  • Pump or valve failure caused by wear, blockage or electrical faults, resulting in low treatment flow or inability to route water correctly
  • Leakage caused by seal, housing, membrane, pressure-vessel or piping deterioration, resulting in water loss and unstable process conditions
Service: Inspect filters, membranes, lamps, dosing equipment, treatment vessels, pumps, valves, sensors and sample points as applicable to the installed process. Maintain hygienic conditions during opening of potable-water equipment. Trend pressure drop and water-quality indications and investigate abnormal values promptly. Verify alarms, regeneration, diversion or shutdown functions after maintenance. Store chemicals and treatment media according to approved procedures. Refer to the manufacturer documentation for the exact figure for dosing, replacement, cleaning and water-quality settings.
Spare Parts: Keep filter elements, membrane or lamp components, approved treatment media, dosing-pump service parts, seals, valves, sensors and sampling consumables recommended for the installed process. Chemicals must be approved for the intended water service.
Use Cases: It is used for freshwater, potable-water and sanitary treatment on merchant ships, passenger vessels, offshore units or other vessel types where this equipment category is fitted.
UV Sterilizer 3m3h Lutz-Jesco Marine unverified
Capacity (m³/h)
3
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Reduced treatment performance caused by fouled filters, exhausted media, scaled membranes, aged lamps or contaminated process surfaces, resulting in poor water quality or increased pressure drop
  • Dosing, regeneration or process-control failure caused by empty consumables, pump faults or control errors, resulting in incorrect treatment conditions
  • Sensor or conductivity fault caused by fouling, calibration drift or wiring problems, resulting in implausible readings or alarms
  • Pump or valve failure caused by wear, blockage or electrical faults, resulting in low treatment flow or inability to route water correctly
  • Leakage caused by seal, housing, membrane, pressure-vessel or piping deterioration, resulting in water loss and unstable process conditions
Service: Inspect filters, membranes, lamps, dosing equipment, treatment vessels, pumps, valves, sensors and sample points as applicable to the installed process. Maintain hygienic conditions during opening of potable-water equipment. Trend pressure drop and water-quality indications and investigate abnormal values promptly. Verify alarms, regeneration, diversion or shutdown functions after maintenance. Store chemicals and treatment media according to approved procedures. Refer to the manufacturer documentation for the exact figure for dosing, replacement, cleaning and water-quality settings.
Spare Parts: Keep filter elements, membrane or lamp components, approved treatment media, dosing-pump service parts, seals, valves, sensors and sampling consumables recommended for the installed process. Chemicals must be approved for the intended water service.
Use Cases: It is used for freshwater, potable-water and sanitary treatment on merchant ships, passenger vessels, offshore units or other vessel types where this equipment category is fitted.
UV Sterilizer 5m3h Lutz-Jesco Marine unverified
Capacity (m³/h)
5
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Reduced treatment performance caused by fouled filters, exhausted media, scaled membranes, aged lamps or contaminated process surfaces, resulting in poor water quality or increased pressure drop
  • Dosing, regeneration or process-control failure caused by empty consumables, pump faults or control errors, resulting in incorrect treatment conditions
  • Sensor or conductivity fault caused by fouling, calibration drift or wiring problems, resulting in implausible readings or alarms
  • Pump or valve failure caused by wear, blockage or electrical faults, resulting in low treatment flow or inability to route water correctly
  • Leakage caused by seal, housing, membrane, pressure-vessel or piping deterioration, resulting in water loss and unstable process conditions
Service: Inspect filters, membranes, lamps, dosing equipment, treatment vessels, pumps, valves, sensors and sample points as applicable to the installed process. Maintain hygienic conditions during opening of potable-water equipment. Trend pressure drop and water-quality indications and investigate abnormal values promptly. Verify alarms, regeneration, diversion or shutdown functions after maintenance. Store chemicals and treatment media according to approved procedures. Refer to the manufacturer documentation for the exact figure for dosing, replacement, cleaning and water-quality settings.
Spare Parts: Keep filter elements, membrane or lamp components, approved treatment media, dosing-pump service parts, seals, valves, sensors and sampling consumables recommended for the installed process. Chemicals must be approved for the intended water service.
Use Cases: It is used for freshwater, potable-water and sanitary treatment on merchant ships, passenger vessels, offshore units or other vessel types where this equipment category is fitted.
UV Sterilizer 8m3h Lutz-Jesco Marine unverified
Capacity (m³/h)
8
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Reduced treatment performance caused by fouled filters, exhausted media, scaled membranes, aged lamps or contaminated process surfaces, resulting in poor water quality or increased pressure drop
  • Dosing, regeneration or process-control failure caused by empty consumables, pump faults or control errors, resulting in incorrect treatment conditions
  • Sensor or conductivity fault caused by fouling, calibration drift or wiring problems, resulting in implausible readings or alarms
  • Pump or valve failure caused by wear, blockage or electrical faults, resulting in low treatment flow or inability to route water correctly
  • Leakage caused by seal, housing, membrane, pressure-vessel or piping deterioration, resulting in water loss and unstable process conditions
Service: Inspect filters, membranes, lamps, dosing equipment, treatment vessels, pumps, valves, sensors and sample points as applicable to the installed process. Maintain hygienic conditions during opening of potable-water equipment. Trend pressure drop and water-quality indications and investigate abnormal values promptly. Verify alarms, regeneration, diversion or shutdown functions after maintenance. Store chemicals and treatment media according to approved procedures. Refer to the manufacturer documentation for the exact figure for dosing, replacement, cleaning and water-quality settings.
Spare Parts: Keep filter elements, membrane or lamp components, approved treatment media, dosing-pump service parts, seals, valves, sensors and sampling consumables recommended for the installed process. Chemicals must be approved for the intended water service.
Use Cases: It is used for freshwater, potable-water and sanitary treatment on merchant ships, passenger vessels, offshore units or other vessel types where this equipment category is fitted.
UV Sterilizer 10m3h Lutz-Jesco Marine unverified
Capacity (m³/h)
10
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Reduced treatment performance caused by fouled filters, exhausted media, scaled membranes, aged lamps or contaminated process surfaces, resulting in poor water quality or increased pressure drop
  • Dosing, regeneration or process-control failure caused by empty consumables, pump faults or control errors, resulting in incorrect treatment conditions
  • Sensor or conductivity fault caused by fouling, calibration drift or wiring problems, resulting in implausible readings or alarms
  • Pump or valve failure caused by wear, blockage or electrical faults, resulting in low treatment flow or inability to route water correctly
  • Leakage caused by seal, housing, membrane, pressure-vessel or piping deterioration, resulting in water loss and unstable process conditions
Service: Inspect filters, membranes, lamps, dosing equipment, treatment vessels, pumps, valves, sensors and sample points as applicable to the installed process. Maintain hygienic conditions during opening of potable-water equipment. Trend pressure drop and water-quality indications and investigate abnormal values promptly. Verify alarms, regeneration, diversion or shutdown functions after maintenance. Store chemicals and treatment media according to approved procedures. Refer to the manufacturer documentation for the exact figure for dosing, replacement, cleaning and water-quality settings.
Spare Parts: Keep filter elements, membrane or lamp components, approved treatment media, dosing-pump service parts, seals, valves, sensors and sampling consumables recommended for the installed process. Chemicals must be approved for the intended water service.
Use Cases: It is used for freshwater, potable-water and sanitary treatment on merchant ships, passenger vessels, offshore units or other vessel types where this equipment category is fitted.
UV Sterilizer 15m3h Lutz-Jesco Marine unverified
Capacity (m³/h)
15
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Reduced treatment performance caused by fouled filters, exhausted media, scaled membranes, aged lamps or contaminated process surfaces, resulting in poor water quality or increased pressure drop
  • Dosing, regeneration or process-control failure caused by empty consumables, pump faults or control errors, resulting in incorrect treatment conditions
  • Sensor or conductivity fault caused by fouling, calibration drift or wiring problems, resulting in implausible readings or alarms
  • Pump or valve failure caused by wear, blockage or electrical faults, resulting in low treatment flow or inability to route water correctly
  • Leakage caused by seal, housing, membrane, pressure-vessel or piping deterioration, resulting in water loss and unstable process conditions
Service: Inspect filters, membranes, lamps, dosing equipment, treatment vessels, pumps, valves, sensors and sample points as applicable to the installed process. Maintain hygienic conditions during opening of potable-water equipment. Trend pressure drop and water-quality indications and investigate abnormal values promptly. Verify alarms, regeneration, diversion or shutdown functions after maintenance. Store chemicals and treatment media according to approved procedures. Refer to the manufacturer documentation for the exact figure for dosing, replacement, cleaning and water-quality settings.
Spare Parts: Keep filter elements, membrane or lamp components, approved treatment media, dosing-pump service parts, seals, valves, sensors and sampling consumables recommended for the installed process. Chemicals must be approved for the intended water service.
Use Cases: It is used for freshwater, potable-water and sanitary treatment on merchant ships, passenger vessels, offshore units or other vessel types where this equipment category is fitted.
UV Sterilizer 20m3h Lutz-Jesco Marine unverified
Capacity (m³/h)
20
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Reduced treatment performance caused by fouled filters, exhausted media, scaled membranes, aged lamps or contaminated process surfaces, resulting in poor water quality or increased pressure drop
  • Dosing, regeneration or process-control failure caused by empty consumables, pump faults or control errors, resulting in incorrect treatment conditions
  • Sensor or conductivity fault caused by fouling, calibration drift or wiring problems, resulting in implausible readings or alarms
  • Pump or valve failure caused by wear, blockage or electrical faults, resulting in low treatment flow or inability to route water correctly
  • Leakage caused by seal, housing, membrane, pressure-vessel or piping deterioration, resulting in water loss and unstable process conditions
Service: Inspect filters, membranes, lamps, dosing equipment, treatment vessels, pumps, valves, sensors and sample points as applicable to the installed process. Maintain hygienic conditions during opening of potable-water equipment. Trend pressure drop and water-quality indications and investigate abnormal values promptly. Verify alarms, regeneration, diversion or shutdown functions after maintenance. Store chemicals and treatment media according to approved procedures. Refer to the manufacturer documentation for the exact figure for dosing, replacement, cleaning and water-quality settings.
Spare Parts: Keep filter elements, membrane or lamp components, approved treatment media, dosing-pump service parts, seals, valves, sensors and sampling consumables recommended for the installed process. Chemicals must be approved for the intended water service.
Use Cases: It is used for freshwater, potable-water and sanitary treatment on merchant ships, passenger vessels, offshore units or other vessel types where this equipment category is fitted.
UV Sterilizer 30m3h Lutz-Jesco Marine unverified
Capacity (m³/h)
30
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Reduced treatment performance caused by fouled filters, exhausted media, scaled membranes, aged lamps or contaminated process surfaces, resulting in poor water quality or increased pressure drop
  • Dosing, regeneration or process-control failure caused by empty consumables, pump faults or control errors, resulting in incorrect treatment conditions
  • Sensor or conductivity fault caused by fouling, calibration drift or wiring problems, resulting in implausible readings or alarms
  • Pump or valve failure caused by wear, blockage or electrical faults, resulting in low treatment flow or inability to route water correctly
  • Leakage caused by seal, housing, membrane, pressure-vessel or piping deterioration, resulting in water loss and unstable process conditions
Service: Inspect filters, membranes, lamps, dosing equipment, treatment vessels, pumps, valves, sensors and sample points as applicable to the installed process. Maintain hygienic conditions during opening of potable-water equipment. Trend pressure drop and water-quality indications and investigate abnormal values promptly. Verify alarms, regeneration, diversion or shutdown functions after maintenance. Store chemicals and treatment media according to approved procedures. Refer to the manufacturer documentation for the exact figure for dosing, replacement, cleaning and water-quality settings.
Spare Parts: Keep filter elements, membrane or lamp components, approved treatment media, dosing-pump service parts, seals, valves, sensors and sampling consumables recommended for the installed process. Chemicals must be approved for the intended water service.
Use Cases: It is used for freshwater, potable-water and sanitary treatment on merchant ships, passenger vessels, offshore units or other vessel types where this equipment category is fitted.
UV Sterilizer 50m3h Lutz-Jesco Marine unverified
Capacity (m³/h)
50
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Reduced treatment performance caused by fouled filters, exhausted media, scaled membranes, aged lamps or contaminated process surfaces, resulting in poor water quality or increased pressure drop
  • Dosing, regeneration or process-control failure caused by empty consumables, pump faults or control errors, resulting in incorrect treatment conditions
  • Sensor or conductivity fault caused by fouling, calibration drift or wiring problems, resulting in implausible readings or alarms
  • Pump or valve failure caused by wear, blockage or electrical faults, resulting in low treatment flow or inability to route water correctly
  • Leakage caused by seal, housing, membrane, pressure-vessel or piping deterioration, resulting in water loss and unstable process conditions
Service: Inspect filters, membranes, lamps, dosing equipment, treatment vessels, pumps, valves, sensors and sample points as applicable to the installed process. Maintain hygienic conditions during opening of potable-water equipment. Trend pressure drop and water-quality indications and investigate abnormal values promptly. Verify alarms, regeneration, diversion or shutdown functions after maintenance. Store chemicals and treatment media according to approved procedures. Refer to the manufacturer documentation for the exact figure for dosing, replacement, cleaning and water-quality settings.
Spare Parts: Keep filter elements, membrane or lamp components, approved treatment media, dosing-pump service parts, seals, valves, sensors and sampling consumables recommended for the installed process. Chemicals must be approved for the intended water service.
Use Cases: It is used for freshwater, potable-water and sanitary treatment on merchant ships, passenger vessels, offshore units or other vessel types where this equipment category is fitted.

Sasakura

11
UV Sterilizer 0.5m3h Sasakura Marine unverified
Capacity (m³/h)
0.5
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Reduced treatment or sanitary performance caused by fouled filters, exhausted media, scaled membranes, aged lamps or blocked piping, resulting in poor water quality, low flow or system alarms
  • Dosing, regeneration or vacuum failure caused by empty chemical supply, pump faults, air leakage or control errors, resulting in incorrect water chemistry or poor sanitary operation
  • Sensor or conductivity fault caused by fouling, calibration drift or wiring problems, resulting in implausible readings or alarms
  • Pump or valve failure caused by wear, blockage or electrical faults, resulting in low treatment flow or inability to route water correctly
  • Leakage caused by seal, housing, membrane or piping deterioration, resulting in water loss, vacuum loss or unstable process conditions
Service: Inspect filters, membranes, lamps, dosing equipment, softener vessels, pumps, valves, vacuum equipment, sensors and sample points as applicable to the installed process. Maintain hygienic conditions during opening of potable-water treatment equipment. Trend pressure, vacuum and water-quality indications and investigate abnormal values promptly. Verify alarms, regeneration, diversion, flushing or shutdown functions after maintenance. Store chemicals and treatment media according to approved procedures. Refer to the manufacturer documentation for the exact figure for dosing, replacement, cleaning and operating settings.
Spare Parts: Keep filter elements, membrane or lamp components, approved treatment media, dosing-pump or vacuum-system service parts, seals, valves, sensors and sampling consumables recommended for the installed process. Chemicals must be approved for the intended water service. Confirm exact replacement parts against unit configuration.
Use Cases: Freshwater production, conditioning, disinfection, domestic hot-water and sanitary treatment on merchant ships, passenger vessels and offshore units.
UV Sterilizer 1m3h Sasakura Marine unverified
Capacity (m³/h)
1
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Scale, exhausted media or dirty treatment surfaces reduce treatment effectiveness and cause poor water quality
  • Lamp, dosing pump, valve or power-supply faults cause loss of treatment and system alarms
  • Sensor, conductivity or dosing-control faults cause under-treatment, over-treatment or false indication
  • Filter or strainer blockage reduces flow and increases differential pressure
  • Seal, vessel or piping leakage causes water loss and may contaminate the treatment area
Service: Inspect treatment elements, filters, pumps, dosing equipment, sensors, valves and leakage according to the installed process. Trend water-quality results and replace or regenerate treatment media using approved procedures. Keep chemical and UV safety controls intact. Refer to the manufacturer documentation for the exact figure for dose, flow, regeneration and water-quality criteria.
Spare Parts: Carry filters, lamps or treatment media as applicable, pump seals, dosing tubing, sensors, valve parts and approved treatment consumables.
Use Cases: Potable-water disinfection, softening, mineral conditioning and domestic water treatment.
UV Sterilizer 2m3h Sasakura Marine unverified
Capacity (m³/h)
2
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Scale, exhausted media or dirty treatment surfaces reduce treatment effectiveness and cause poor water quality
  • Lamp, dosing pump, valve or power-supply faults cause loss of treatment and system alarms
  • Sensor, conductivity or dosing-control faults cause under-treatment, over-treatment or false indication
  • Filter or strainer blockage reduces flow and increases differential pressure
  • Seal, vessel or piping leakage causes water loss and may contaminate the treatment area
Service: Inspect treatment elements, filters, pumps, dosing equipment, sensors, valves and leakage according to the installed process. Trend water-quality results and replace or regenerate treatment media using approved procedures. Keep chemical and UV safety controls intact. Refer to the manufacturer documentation for the exact figure for dose, flow, regeneration and water-quality criteria.
Spare Parts: Carry filters, lamps or treatment media as applicable, pump seals, dosing tubing, sensors, valve parts and approved treatment consumables.
Use Cases: Potable-water disinfection, softening, mineral conditioning and domestic water treatment.
UV Sterilizer 3m3h Sasakura Marine unverified
Capacity (m³/h)
3
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Scale, exhausted media or dirty treatment surfaces reduce treatment effectiveness and cause poor water quality
  • Lamp, dosing pump, valve or power-supply faults cause loss of treatment and system alarms
  • Sensor, conductivity or dosing-control faults cause under-treatment, over-treatment or false indication
  • Filter or strainer blockage reduces flow and increases differential pressure
  • Seal, vessel or piping leakage causes water loss and may contaminate the treatment area
Service: Inspect treatment elements, filters, pumps, dosing equipment, sensors, valves and leakage according to the installed process. Trend water-quality results and replace or regenerate treatment media using approved procedures. Keep chemical and UV safety controls intact. Refer to the manufacturer documentation for the exact figure for dose, flow, regeneration and water-quality criteria.
Spare Parts: Carry filters, lamps or treatment media as applicable, pump seals, dosing tubing, sensors, valve parts and approved treatment consumables.
Use Cases: Potable-water disinfection, softening, mineral conditioning and domestic water treatment.
UV Sterilizer 5m3h Sasakura Marine unverified
Capacity (m³/h)
5
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Scale, exhausted media or dirty treatment surfaces reduce treatment effectiveness and cause poor water quality
  • Lamp, dosing pump, valve or power-supply faults cause loss of treatment and system alarms
  • Sensor, conductivity or dosing-control faults cause under-treatment, over-treatment or false indication
  • Filter or strainer blockage reduces flow and increases differential pressure
  • Seal, vessel or piping leakage causes water loss and may contaminate the treatment area
Service: Inspect treatment elements, filters, pumps, dosing equipment, sensors, valves and leakage according to the installed process. Trend water-quality results and replace or regenerate treatment media using approved procedures. Keep chemical and UV safety controls intact. Refer to the manufacturer documentation for the exact figure for dose, flow, regeneration and water-quality criteria.
Spare Parts: Carry filters, lamps or treatment media as applicable, pump seals, dosing tubing, sensors, valve parts and approved treatment consumables.
Use Cases: Potable-water disinfection, softening, mineral conditioning and domestic water treatment.
UV Sterilizer 8m3h Sasakura Marine unverified
Capacity (m³/h)
8
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Scale, exhausted media or dirty treatment surfaces reduce treatment effectiveness and cause poor water quality
  • Lamp, dosing pump, valve or power-supply faults cause loss of treatment and system alarms
  • Sensor, conductivity or dosing-control faults cause under-treatment, over-treatment or false indication
  • Filter or strainer blockage reduces flow and increases differential pressure
  • Seal, vessel or piping leakage causes water loss and may contaminate the treatment area
Service: Inspect treatment elements, filters, pumps, dosing equipment, sensors, valves and leakage according to the installed process. Trend water-quality results and replace or regenerate treatment media using approved procedures. Keep chemical and UV safety controls intact. Refer to the manufacturer documentation for the exact figure for dose, flow, regeneration and water-quality criteria.
Spare Parts: Carry filters, lamps or treatment media as applicable, pump seals, dosing tubing, sensors, valve parts and approved treatment consumables.
Use Cases: Potable-water disinfection, softening, mineral conditioning and domestic water treatment.
UV Sterilizer 10m3h Sasakura Marine unverified
Capacity (m³/h)
10
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Scale, exhausted media or dirty treatment surfaces reduce treatment effectiveness and cause poor water quality
  • Lamp, dosing pump, valve or power-supply faults cause loss of treatment and system alarms
  • Sensor, conductivity or dosing-control faults cause under-treatment, over-treatment or false indication
  • Filter or strainer blockage reduces flow and increases differential pressure
  • Seal, vessel or piping leakage causes water loss and may contaminate the treatment area
Service: Inspect treatment elements, filters, pumps, dosing equipment, sensors, valves and leakage according to the installed process. Trend water-quality results and replace or regenerate treatment media using approved procedures. Keep chemical and UV safety controls intact. Refer to the manufacturer documentation for the exact figure for dose, flow, regeneration and water-quality criteria.
Spare Parts: Carry filters, lamps or treatment media as applicable, pump seals, dosing tubing, sensors, valve parts and approved treatment consumables.
Use Cases: Potable-water disinfection, softening, mineral conditioning and domestic water treatment.
UV Sterilizer 15m3h Sasakura Marine unverified
Capacity (m³/h)
15
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Scale, exhausted media or dirty treatment surfaces reduce treatment effectiveness and cause poor water quality
  • Lamp, dosing pump, valve or power-supply faults cause loss of treatment and system alarms
  • Sensor, conductivity or dosing-control faults cause under-treatment, over-treatment or false indication
  • Filter or strainer blockage reduces flow and increases differential pressure
  • Seal, vessel or piping leakage causes water loss and may contaminate the treatment area
Service: Inspect treatment elements, filters, pumps, dosing equipment, sensors, valves and leakage according to the installed process. Trend water-quality results and replace or regenerate treatment media using approved procedures. Keep chemical and UV safety controls intact. Refer to the manufacturer documentation for the exact figure for dose, flow, regeneration and water-quality criteria.
Spare Parts: Carry filters, lamps or treatment media as applicable, pump seals, dosing tubing, sensors, valve parts and approved treatment consumables.
Use Cases: Potable-water disinfection, softening, mineral conditioning and domestic water treatment.
UV Sterilizer 20m3h Sasakura Marine unverified
Capacity (m³/h)
20
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Scale, exhausted media or dirty treatment surfaces reduce treatment effectiveness and cause poor water quality
  • Lamp, dosing pump, valve or power-supply faults cause loss of treatment and system alarms
  • Sensor, conductivity or dosing-control faults cause under-treatment, over-treatment or false indication
  • Filter or strainer blockage reduces flow and increases differential pressure
  • Seal, vessel or piping leakage causes water loss and may contaminate the treatment area
Service: Inspect treatment elements, filters, pumps, dosing equipment, sensors, valves and leakage according to the installed process. Trend water-quality results and replace or regenerate treatment media using approved procedures. Keep chemical and UV safety controls intact. Refer to the manufacturer documentation for the exact figure for dose, flow, regeneration and water-quality criteria.
Spare Parts: Carry filters, lamps or treatment media as applicable, pump seals, dosing tubing, sensors, valve parts and approved treatment consumables.
Use Cases: Potable-water disinfection, softening, mineral conditioning and domestic water treatment.
UV Sterilizer 30m3h Sasakura Marine unverified
Capacity (m³/h)
30
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Scale, exhausted media or dirty treatment surfaces reduce treatment effectiveness and cause poor water quality
  • Lamp, dosing pump, valve or power-supply faults cause loss of treatment and system alarms
  • Sensor, conductivity or dosing-control faults cause under-treatment, over-treatment or false indication
  • Filter or strainer blockage reduces flow and increases differential pressure
  • Seal, vessel or piping leakage causes water loss and may contaminate the treatment area
Service: Inspect treatment elements, filters, pumps, dosing equipment, sensors, valves and leakage according to the installed process. Trend water-quality results and replace or regenerate treatment media using approved procedures. Keep chemical and UV safety controls intact. Refer to the manufacturer documentation for the exact figure for dose, flow, regeneration and water-quality criteria.
Spare Parts: Carry filters, lamps or treatment media as applicable, pump seals, dosing tubing, sensors, valve parts and approved treatment consumables.
Use Cases: Potable-water disinfection, softening, mineral conditioning and domestic water treatment.
UV Sterilizer 50m3h Sasakura Marine unverified
Capacity (m³/h)
50
Treatment Type
UV Sterilizer
Common Failures & Inspection Points
  • Scale, exhausted media or dirty treatment surfaces reduce treatment effectiveness and cause poor water quality
  • Lamp, dosing pump, valve or power-supply faults cause loss of treatment and system alarms
  • Sensor, conductivity or dosing-control faults cause under-treatment, over-treatment or false indication
  • Filter or strainer blockage reduces flow and increases differential pressure
  • Seal, vessel or piping leakage causes water loss and may contaminate the treatment area
Service: Inspect treatment elements, filters, pumps, dosing equipment, sensors, valves and leakage according to the installed process. Trend water-quality results and replace or regenerate treatment media using approved procedures. Keep chemical and UV safety controls intact. Refer to the manufacturer documentation for the exact figure for dose, flow, regeneration and water-quality criteria.
Spare Parts: Carry filters, lamps or treatment media as applicable, pump seals, dosing tubing, sensors, valve parts and approved treatment consumables.
Use Cases: Potable-water disinfection, softening, mineral conditioning and domestic water treatment.