OceanSphereENGINES
Library› Engine Room› Heat Exchangers› Brazed Plate Heat Exchanger› SWEP B12 200kW LO cooling

B12 200kW LO cooling

Brazed Plate Heat Exchanger · Heat Exchangers

Class-certified type (DNV register) · technical data sheet not yet verified​‌​⁠‌​‍​‍​‌⁠​⁠‌‍​‍⁠‍
Specifications

Technical data.reference — unverified

Do you have the manufacturer datasheet for this model? Send it with the enquiry form — we check it and name the source.

Heat Exchanger TypeBrazed Plate Heat Exchanger
Capacity (kW)200
MaterialStainless Steel 316
Inspection

Inspector Detail

Common issues

  • Internal fouling from lube oil degradation products/varnish restricting flow and reducing heat transfer
  • Cross-contamination between circuits following an internal braze/plate failure
  • External corrosion at connections and nozzles, particularly with dissimilar-metal contact
  • Reduced LO cooling capacity from partial blockage of the narrow plate channels
  • Fatigue cracking of brazed joints from thermal cycling or pressure pulsation
  • External fouling or scale build-up on the coolant-side if seawater or untreated fresh water is used
  • Vibration-induced fatigue at pipework connections

Inspection checklist

  • Check differential pressure across the LO side against the commissioning baseline
  • Monitor outlet temperature/approach temperature against design to detect performance degradation
  • Inspect the external shell and connections for oil weepage indicating an internal leak
  • Check for external corrosion, especially at brazed end connections and mounting brackets
  • Verify any fitted insulation is intact and not trapping moisture against the shell
  • Check mounting/support brackets for vibration-related fatigue cracks
  • Sample oil for coolant contamination if an internal leak is suspected
  • Confirm associated pressure relief/safety devices are functional

Service intervals

Chemical (CIP) cleaningcondition-based, typically every 1-3 years depending on oil condition and duty
Differential pressure trend checkmonthly to quarterly as part of routine monitoring
Full performance/thermal efficiency checkannual
External visual inspectionevery 3-6 months or per the PMS

Typical intervals for this design class, not the manufacturer’s figures for your model. The manufacturer’s manual is binding.

Typical wear limits

Differential pressure across the unit (fouling indicator)flag for cleaning once DP rises noticeably above the commissioning baseline - as a general guide often in the order of 1.5-2x clean condition, confirm against the original design DP
Thermal approach temperaturean increase of more than a few degrees C above the design approach typically indicates fouling or reduced performance - compare against commissioning data
External connection wall conditionassess by visual/thickness check against original nozzle wall thickness - no universal numeric limit, follow the class thickness-gauging criteria applied to the associated piping

Ranges are typical for this design class. Always confirm against the manufacturer documentation for your serial number.

Critical spares

  • Complete replacement unit - brazed plate exchangers are fully sealed and cannot be reopened or re-plated in the field
  • Gaskets/O-rings at pipe connections (flanged or threaded joints only, none internal)
  • Isolation valves and associated pipe fittings
  • Temperature and pressure sensors fitted to the circuit
  • Mounting/support bracket hardware

Safety

  • Hot surfaces on the LO-side piping and connections - burn hazard
  • Pressurised system - isolate and depressurise fully before disconnecting any joint
  • Risk of oil mist or spray if a connection is broken under residual pressure
  • Confined space considerations if the unit is mounted in a tight engine room location

Class survey

Where part of a class-surveyed cooling system, typically falls under Continuous Survey Machinery. Class looks for pressure testing history, a fouling-related cleaning routine in the PMS, and evidence of leak-free operation. No internal survey is possible on a brazed unit - assessment relies on performance trending and external inspection.

Estimated lifetime: Not conventionally rated in running hours since there are no moving parts. Brazed plate heat exchangers of this class typically give 15-25 years of service if kept within design pressure/temperature and fouling is controlled.

Need this part?

Request a quote for this model.

Free of charge — send us your request for SWEP equipment. Our team checks it and replies by e-mail.

For marine equipment hardly any maker or authorised dealer will name a price while the vessel is unknown. With the vessel details, availability and price can be settled faster; without them we may have to ask first, which costs a few days. If you are not allowed to name the vessel, a photo of the rating plate is enough — attach it below or send it as a reply to our confirmation e-mail.

Your contact details are not published. No account required.
Related models

Also in Brazed Plate Heat Exchanger.

Other models of the same equipment type, SWEP first.

By manufacturer SWEPDanfossOndaAlfa LavalKelvionFunkehydroWieland Provides S.r.l.All manufacturersSpare parts by equipmentNew here? Create a free account Can't read the plate? Try the nameplate scanner All SWEP models More like SWEP B12 200kW LO cooling
More than the data sheet shows

We answer by e-mail, never with an automatic reply.

Tell us what you need for this SWEP B12 200kW LO cooling — a part, a service call, a second opinion. Are you SWEP? Claim this brand page.

Service engineer? Write the day report for this B12 200kW LO cooling in OceanSphere Work — photos, hours and parts, as a PDF for the owner. Try it free for 14 days →

Frequently asked

Questions that come up with this equipment.

Is this model's data free?

Yes. Specifications, documents and service notes for this model are readable without an account. An account adds saved searches and requests, nothing is taken away.

Can you find a part for this exact model?

Yes. Tell us the manufacturer, the model and what you need — a person reads every request and replies by e-mail.

The specifications look wrong — what now?

Send us the nameplate or the correct value. We check it against the manufacturer datasheet or class-society record and update the page.