"> SWEP B12
⚓ Working on this equipment?
Ask the AI troubleshooter, log your hours on board and turn them into invoice-ready service reports — for this exact model.
Start free — 14 days →
No credit card required
🔧 6 verified suppliers & service companies for SWEP in the Maritime Network Find suppliers →
SWEP

B12

SWEP B12 — Large flow applications, steam/air dryer, desuperheater.

SWEP B12

Components & Design

Component data being added…

Technical Data

Type Large-port brazed plate heat exchanger
Application High-flow steam, air dryer, CO2 suction gas

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Leakage at port connections or internal brazing

Visually inspect all port connections monthly for liquid weeping, staining, or corrosion. Perform pressure test at rated working pressure annually to detect internal joint failure. Check for signs of seepage at solder joints.

Reduced heat transfer efficiency or fouling/scaling

Monitor return temperatures - smaller-than-specified temperature differences indicate fouling. Use SWEP's pressure drop calculation tool: 30% pressure drop increase from clean baseline indicates cleaning is needed. Compare measured vs. expected performance quarterly.

Vibration damage or mechanical stress

Check for excessive pulsations or cyclic pressure/temperature changes. Verify vibration isolators are installed and functioning. Inspect plates for deformation or cracking under UV/bright light. Avoid pressure spikes exceeding 10% of rated maximum.

Corrosion or material degradation (non-All-Stainless units)

Inspect external surfaces monthly for pitting, discoloration, or rust deposits. For All-Stainless units, verify Sealix protective layer integrity. Check fluids for metal leaching particles using optical inspection or ICP-OES testing annually.

Blockage in ports, channels, or flow distribution

Verify inlet/outlet flow rates match design specification (compare to pressure drop). Listen for unusual fluid noise indicating turbulence or cavitation. Perform CIP (Cleaning in Place) if flows decrease unexpectedly. Check inlet strainer condition.

Type-general inspection and maintenance points for this equipment category — not model-specific.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →
Equipment Model #148234 · ✓ still in production

Wer liefert dieses Teil? 13 Betriebe im Verzeichnis · 8 aus Herstellerlisten

Buffers USA Inc
Jacksonville, United States
Dolphin Marine Engineering & Trading Co., Ltd
China
Japan Marine (S) Pte Ltd
Singapore, Singapore
KET Marine BV
Netherlands
LING CHUAN MARINE EQUIPMENT LIMITED
China
Mares Shipping GmbH
Hamburg, Germany
Marine Technic A/S
Naestved, Denmark
PSYCTOTHERM (Ligeros G & Sia OE)
Piraeus, Greece
SWEP International PHE AB
Sweden
Sai Shakti Engineering Solutions
Saudi Arabia
Swep Marketing BV BeNeLux
Netherlands
TAIWAN SRP HEAT EXCHANGER INC.
New Taipei City, Taiwan
Weitere aus Hersteller- und Marktplatzverzeichnissen:
Dallaserra Ridderkerk Spares BV · NetherlandsHenry Marine A/S · DenmarkOco Marine Equipment Ltd. · ChinaPARAT Halvorsen A/S · NorwaySudoservice GmbH · GermanyTeknotherm Marine AS · NorwayVivar Ship Supply · NetherlandsWRIST-KLEVENBERG SHIP SUPPLY B.V
Alle Betriebe für SWEP ansehen →