Verbundkessel · Kessel
The KEPCO KCB 5t/10bar is a composite marine boiler. It is normally installed in the engine room connected to both a burner fuel system and an engine exhaust path. It is designed for steam production from exhaust heat at sea and from fuel firing when needed. In operation, integrated fired and exhaust-gas heating sections serve a common steam/water system. Compared with neighbouring models, the relevant differences are steam capacity, pressure, exhaust section, burner arrangement and mode control; these must be confirmed from the installed documentation rather than inferred from the model designation alone. Service and survey attention should concentrate on burner, exhaust-side fouling, water level, pressure parts, mode-change controls and safety devices. For exact ratings, dimensions, tolerances, test limits and model-specific settings, refer to the manufacturer documentation for the exact figure.
Haben Sie das Herstellerdatenblatt zu diesem Modell? Schicken Sie es mit dem Anfrageformular — wir prüfen es und nennen die Quelle.
Was unsere Servicearbeit und die Herstellerunterlagen zum Betrieb dieses Modells sagen.
Inspect pressure parts or heater coils, heat-source/burner and refractory where applicable, gas-side cleanliness, circulation/feed systems and water or thermal-fluid condition. Verify level, pressure, temperature, flow, safety valves and shutdown/interlock functions applicable to the design. Review treatment, blowdown, soot-cleaning and operating records and use manufacturer/class procedures for pressure tests.
Carry approved gaskets, valve service parts, relevant pump seals/bearings, temperature/pressure/level sensors and heat-source-specific spares such as burner ignition/flame components or soot-cleaning parts. Pressure-part repair materials should only be used under approved manufacturer and class procedures.
Kostenlos — senden Sie uns Ihre Anfrage zu KEPCO-Ausrüstung. Unser Team prüft sie und antwortet per E-Mail.
Weitere Modelle desselben Ausrüstungstyps, zuerst KEPCO.
Sagen Sie uns, was Sie für diesen KEPCO KCB 5t/10bar benötigen — ein Ersatzteil, einen Serviceeinsatz, eine zweite Meinung. Sind Sie KEPCO? Diese Herstellerseite beanspruchen.
Servicetechniker? Schreiben Sie den Tagesbericht für diesen KCB 5t/10bar in OceanSphere Work — Fotos, Stunden und Teile, als PDF für den Reeder. 14 Tage kostenlos testen →
Ja. Technische Daten, Dokumente und Servicehinweise zu diesem Modell sind ohne Konto lesbar. Ein Konto bringt gespeicherte Suchen und Anfragen dazu, es nimmt nichts weg.
Ja. Nennen Sie uns Hersteller, Modell und Bedarf — ein Mensch liest jede Anfrage und antwortet per E-Mail.
Schicken Sie uns das Typenschild oder den richtigen Wert. Wir prüfen ihn gegen das Herstellerdatenblatt oder den Klassifikationsdatensatz und aktualisieren die Seite.