"> Miura Miura LX Series
⚓ Working on this equipment?
Ask the AI troubleshooter, log your hours on board and turn them into invoice-ready service reports — for this exact model.
Start free — 14 days →
No credit card required
🔧 10 verified suppliers & service companies for Miura in the Maritime Network Find suppliers →
Miura

Miura LX Series

Miura Miura LX Series is a marine auxiliary oil-fired boiler listed in the supplied equipment record. It is normally installed in the engine room or boiler space, connected to the vessel steam, feedwater, fuel, combustion-air and exhaust systems. Its primary purpose is to generate steam for heating, fuel treatment, domestic services, tank heating or other shipboard consumers. Compared with exhaust-gas boilers, an oil-fired auxiliary boiler can generate steam independently of main-engine exhaust conditions and therefore includes its own burner and combustion-control equipment. The model designation identifies a particular manufacturer configuration, but the supplied record does not define every hardware, material, control, or certification difference to adjacent models. For exact ratings, dimensions, settings, materials, connection details, and variant-specific limits, refer to the manufacturer documentation for the exact figure.

Components & Design

Component data being added…

Technical Data

boiler type auxiliary_oil-fired_boiler

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Burner-nozzle fouling, poor atomization or ignition failure causes smoky combustion, flame failure alarms or inability to raise steam
Feedwater-control or level-sensing faults cause unstable drum level, low-level trips or abnormal feed-pump cycling
Soot, scale or deposits on heating surfaces reduce heat transfer and cause higher exhaust temperature, poor steaming rate or local overheating
Fuel, steam or water leakage from valves, gaskets or tubes causes visible leakage, pressure loss or abnormal make-up demand
Combustion-control, fan or flame-monitoring faults cause unstable firing, repeated burner trips or unsafe-start interlock failure

Service & Maintenance

Inspect furnace, burner, refractory, pressure parts, mountings, water-level devices, safety valves and combustion controls. Review boiler-water treatment and evidence of scale, corrosion or carry-over. Function-test low-water protection, flame failure, pressure control and alarms under the approved procedure. Pressure-part limits, burner settings and water chemistry must follow manufacturer and statutory documentation.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

Replacement Parts

Carry burner nozzles, ignition and flame-detection parts, fuel-filter elements, valve and pump seal kits, water-level control components, gaskets, selected control relays and other manufacturer-recommended boiler consumables.