"> Alfa Laval MOPX 209 VLSFO
⚓ Working on this equipment?
Ask the AI troubleshooter, log your hours on board and turn them into invoice-ready service reports — for this exact model.
Start free — 14 days →
No credit card required
🔧 114 verified suppliers & service companies for Alfa Laval in the Maritime Network Find suppliers →
Alfa Laval

MOPX 209 VLSFO

Alfa Laval Fuel Oil Treatment. The Alfa Laval Fuel Conditioning Module is a two-stage automated pressure booster system that conditions ship diesel fuel (HFO, MDO, MGO and alternative fuels such as methanol, LPG, ammonia and LNG). The system regulates purity, pressure, temperature, viscosity and flow according to ship engine manufacturer specifications. The FCM utilizes

Components & Design

Component data being added…

Technical Data

throughput lh 2090
fuel type VLSFO
filtration micron 10

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Filter element overload and pressure drop

Monitor and document differential pressure of automatic back-flushing filter; Check switchover to manual bypass filter; Control wear condition of disk elements; Replace filter if visual wear or insufficient cleaning; Inspection interval every 2,000 operating hours or at differential pressure alarm

Viskositätskontrolle außerhalb Sollwert (Pump-Seize-Risiko, Einspritzfehler, Antriebs-Totalausfallrisiko)

Check EVT20 viscosity sensor for functionality; Compare EPC50V/EPC70 controller display setpoint/actual value; Test heater thermostat function (for oil FCMs); Viscochief 3 calibration and sensor cleanliness check; Viscosity range ±5% from setpoint (engine-dependent, typical 10-40 cSt @ 50°C); Document fuel changeover ramp tracking

Pump failure risk and pressure supply deficiency symptoms

Check pressure in high-pressure stage: 6-16 bar (engine-dependent); Inspect low-pressure pumps (reserve/service pump) for vibration, noise and leakage; Test pump switchover logic (redundancy check); Check flow sensor at outlet (flow transmitter signal stability); Monitor pump current consumption (VFD versions)

Heizer-Thermostat-Fehlfunktion (zu hohe/zu niedrige Brennstofftemperatur)

Check thermostat setpoint (typical 55-95°C for HFO, engine-dependent) on EPC display; Compare heater outlet temperature with infrared pyrometer or built-in sensor; Check heating element current consumption; Inspect heater block for lime deposits and wear; Test bypass valve for function; Inspection interval: annually or if temperature deviation >5°C

Separator connection and FlowSync synchronization error (insufficient fuel classification)

Compare FlowSync pump speed with engine load signal; Compare separator feed flow with setpoint (variable flow, not constant); Check feed return pressure valve for wear; Verify tank level sensor (safety limit value); Monitor VFD pump speed output signal; Inspection interval: every 500 operating hours or after fuel type change

Automatisches Kontroll-System Ausfallrisiko (Fehlmeldungen, fehlende Automation, manuelles Notfallmodus erforderlich)

EPC50V/EPC70 controller boot sequence test; alarm LEDs and display fault codes document; alarm acknowledge button test for function; safety circuits (emergency shutdown, cooling/heating enable, leak test, purge) check; cable connections and connectors inspect for corrosion; emergency switchover to manual operation training; inspection interval: every 6 months or per service recommendation

Type-general inspection and maintenance points for this equipment category — not model-specific.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →
Equipment Model #69222 · ✓ still in production

Wer liefert dieses Teil? 17 Betriebe im Verzeichnis · 22 aus Herstellerlisten

ALFA LAVAL
Sweden
✓ autorisiert
Alfa Laval Aalborg Oy
Denmark
✓ autorisiert
MACOR
France
✓ autorisiert
CHIEFMAR SRL
Genova, Italy
Fluid Global Solutions S.r.l.
Arcola, Italy
HAGEDORN Products & Systems GmbH
Hemmoor, Germany
HSM Marine Engineering Pte Ltd
Singapore, Singapore
KET Marine BV
Netherlands
Mares Shipping GmbH
Hamburg, Germany
Marine Technic A/S
Naestved, Denmark
Mistral Marine Solutions
Switzerland
Seaway Marine Trading BV
Vlaardingen, Netherlands
Weitere aus Hersteller- und Marktplatzverzeichnissen:
Global Services (Europe) Ltd · United KingdomA. Nobel en Zn. - Filtration & Separation B.V. (Headquarters) · NetherlandsCOOL DYNAMIC - D. GKOUSKOS · GreeceDingbro Ltd Industrial Filtration Division · United KingdomDitco Worldwide Shipsuppliers · NetherlandsEberhardt Agencies ApS · DenmarkEfemarinmotor · TurkeyFamous World Int.Holdings Ltd · ChinaFlorijn Ship Spares · NetherlandsGLINAR Turbo&Diesel · United KingdomGoodwill Industrial Solution Ltd. · TaiwanHMS Hanseatic Marine Services (HQ) · Germany
Alle Betriebe für Alfa Laval ansehen →