OceanSphereENGINES
Biblioteka› Engine Room› Oczyszczanie spalin› Skruber SOx› ZHEJIANG ENERGY MARINE ENVIRONMENTAL TECHNOLOGY CO.,LTD MPUSOx/U-2400 installed onboard BULGARIA (IMO: 9968475)
ZHEJIANG ENERGY MARINE ENVIRONMENTAL TECHNOLOGY CO.,LTD

MPUSOx/U-2400 installed onboard BULGARIA (IMO: 9968475)

Skruber SOx · Oczyszczanie spalin

Typ z certyfikatem klasy (rejestr DNV) · karta techniczna jeszcze niesprawdzona​​‍‍⁠​⁠‌‍‍‍‌‌​‍⁠​⁠‍‍
Zdjęcie przykładowe: Skruber SOx — nie przedstawia tego modelu.

MPUSOx/U-2400 installed onboard BULGARIA (IMO: 9968475) by ZHEJIANG ENERGY MARINE ENVIRONMENTAL TECHNOLOGY CO.,LTD. DNV MED certificate MEDG00001B9.

Dane techniczne

Dane techniczne.

Masz kartę katalogową producenta dla tego modelu? Wyślij ją razem z formularzem zapytania — sprawdzimy ją i podamy źródło.

Zatwierdzone przez IMOYes
Inspekcja

Szczegóły inspektora

Typowe problemy

  • Scrubber tower internal corrosion (acid attack) at packing, demister, and shell in wash-water-wetted zones
  • Demister/mist eliminator fouling or damage causing carryover into the exhaust stream
  • Wash water pump or spray nozzle fouling/wear reducing spray coverage and SOx removal efficiency
  • Effluent treatment unit fouling or reduced separation efficiency (hybrid-mode operation)
  • CEMS sensor (pH, SO2/CO2 ratio, turbidity, PAH) drift or fouling giving unreliable compliance readings
  • Overboard discharge line and valve corrosion or scaling
  • Exhaust gas bypass damper seizure or leakage past the seal

Lista kontrolna przeglądu

  • Verify CEMS calibration (SO2/CO2 ratio, PAH, turbidity, pH) is current
  • Inspect scrubber tower internals (packing, demister) for corrosion/fouling at dry-dock or internal access
  • Check wash water pump and spray nozzle condition and coverage pattern
  • Inspect bypass damper operation and seal condition
  • Check the effluent treatment unit function and sludge/residue handling arrangements (hybrid mode)
  • Verify wash water discharge quality against the applicable MARPOL Annex VI Scrubber Guidelines limits
  • Check coating/lining condition in wash-water-wetted areas
  • Confirm the EGCS record book (operation, exceedance events) is complete and current

Interwały serwisowe

CEMS sensor calibrationper manufacturer, typically every 3-12 months depending on sensor type
Demister/packing inspectionat dry-dock or annually where accessible
Wash water pump/nozzle inspectionevery 2000-4000 running hours or annually
Effluent treatment unit service (hybrid mode)per manufacturer's schedule, typically annual
Coating/lining surveyat each dry-docking

Typowe interwały dla tej klasy konstrukcji, nie dane producenta dla Twojego modelu. Wiążąca jest instrukcja producenta.

Typowe granice zużycia

Tower shell/lining corrosion allowancegoverned by the approved coating/lining system and class scantling requirement - confirm against approved drawings, no generic figure applies
Demister element pressure droprenew when differential pressure exceeds the manufacturer's clean-condition baseline by a significant margin - confirm against the MPUSOx/U-2400 manual
Wash water nozzle spray patternrenew nozzles when spray coverage visibly degrades or SOx removal efficiency trends downward against manufacturer's baseline testing

Zakresy są typowe dla tej klasy konstrukcyjnej. Decydujące są zawsze dokumenty producenta dla danego numeru seryjnego.

Krytyczne części zamienne

  • Wash water spray nozzles
  • Demister/mist eliminator elements
  • CEMS sensor modules (SO2, CO2, pH, turbidity, PAH)
  • Wash water pump seals/impeller
  • Bypass damper actuator/seal kit
  • Effluent treatment consumables/filters for hybrid operation

Bezpieczeństwo

  • Acidic wash water presents a corrosive-fluid contact hazard - PPE required for internal or effluent-system work
  • Confined space entry for scrubber tower internal inspection requires gas-freeing and ventilation checks
  • Bypass damper failure could misroute hot, corrosive exhaust gas - verify damper interlocks before internal entry
  • Unauthorised wash water discharge or sensor bypass is a MARPOL Annex VI compliance violation, not just a maintenance issue

Przegląd klasyfikacyjny

Exhaust gas cleaning systems are a Continuous Survey Machinery item under MARPOL Annex VI/the applicable class EGC notation: continuous monitoring of wash water discharge and CEMS parameters is reviewed, discharge exceedance events in the record book are checked, and internal survey of the scrubber unit (corrosion, lining) is carried out at renewal or dry-docking. Confirm the unit remains within the approved monitoring scheme of the applicable EGCS Guidelines revision, and that the DNV MED certificate (MEDG00001B9) matches the installed unit.

Szacowana trwałość: The scrubber tower structure is generally designed for the vessel's operating life, with lining/coating renewal tied to dry-docking (typically 5-yearly); wear components (nozzles, demister elements, sensors) are renewed on a running-hours or condition basis well before that - confirm against manufacturer documentation for this specific unit.

Klasyfikacja

Zatwierdzenie typu DNV

Wpisany do DNV Approval Finder według stanu z dnia naszego zapisu. Certyfikat wydaje DNV, nie my; aktualny status należy sprawdzić w DNV.

CertyfikatMEDG00001B9
Otwórz certyfikat w DNV
Potrzebujesz tej części?

Zapytaj o ofertę na ten model.

Bezpłatnie — wyślij zapytanie dotyczące sprzętu ZHEJIANG ENERGY MARINE ENVIRONMENTAL TECHNOLOGY CO.,LTD. Nasz zespół je sprawdzi i odpowie e-mailem.

W przypadku sprzętu okrętowego prawie żaden producent ani autoryzowany dystrybutor nie podaje ceny, dopóki statek jest nieznany. Z danymi statku dostępność i cenę da się ustalić szybciej; bez nich być może musimy najpierw dopytać, co kosztuje kilka dni. Jeśli nie wolno Ci podać statku, wystarczy zdjęcie tabliczki znamionowej — dołącz je poniżej lub odeślij w odpowiedzi na nasz e-mail potwierdzający.

Twoje dane kontaktowe nie są publikowane. Konto nie jest wymagane.
Powiązane modeli

Także w Skruber SOx.

Inne modele tego samego typu sprzętu, najpierw ZHEJIANG ENERGY MARINE ENVIRONMENTAL TECHNOLOGY CO.,LTD.

Według producenta Wärtsilä MossYara MarineEcoSprayME ProductionLangh TechHyundai Heavy Industries Power SystemsPanasiaZHEJIANG ENERGY MARINE ENVIRONMENTAL TECHNOLOGY CO.,LTDAndritz MarineHI AIR KOREA Co., Ltd.Alfa LavalPacific Green MarineCR OceanMitsubishi Heavy IndustriesClean Marine ASWszyscy producenciCzęści według urządzeńNowy użytkownik? Załóż darmowe konto Nieczytelna tabliczka? Wypróbuj skaner tabliczek Podobne do MPUSOx/U-2400 installed onboard BULGARIA (IMO: 9968475)
Więcej, niż pokazuje karta katalogowa

Odpowiadamy e-mailem, nigdy automatem.

Powiedz nam, czego potrzebujesz do tego ZHEJIANG ENERGY MARINE ENVIRONMENTAL TECHNOLOGY CO.,LTD MPUSOx/U-2400 installed onboard BULGARIA (IMO: 9968475) — części, wizyty serwisowej, drugiej opinii. Czy jesteś ZHEJIANG ENERGY MARINE ENVIRONMENTAL TECHNOLOGY CO.,LTD? Przejmij tę stronę marki.

Serwisant? Napisz raport dzienny dla tego MPUSOx/U-2400 installed onboard BULGARIA (IMO: 9968475) w OceanSphere Work — zdjęcia, godziny i części, jako PDF dla armatora. Wypróbuj 14 dni za darmo →

Często pytane

Pytania, które pojawiają się przy tym sprzęcie.

Czy dane tego modelu są bezpłatne?

Tak. Dane techniczne, dokumenty i uwagi serwisowe tego modelu są dostępne bez konta. Konto dodaje zapisane wyszukiwania i zapytania, niczego nie odbiera.

Czy znajdziecie część dokładnie do tego modelu?

Tak. Podaj producenta, model i czego potrzebujesz — każde zapytanie czyta człowiek i odpowiada e-mailem.

Dane techniczne wydają się błędne — co teraz?

Wyślij nam tabliczkę lub prawidłową wartość. Sprawdzimy ją w karcie danych producenta lub rejestrze towarzystwa klasyfikacyjnego i zaktualizujemy stronę.