100SC1 Open loop scrubber installed onboard RIO CHARLESTON (IMO: 9362449)

SOx Scrubber · Exhaust Gas Cleaning

Class-certified type (DNV register) · technical data sheet not yet verified​​‍‍‍‍⁠‌‍‍⁠‌​​⁠​‍⁠‍‍

100SC1 Open loop scrubber installed onboard RIO CHARLESTON (IMO: 9362449) by Langh Tech Oy Ab. DNV MED certificate MEDG0000120.

Specifications

Technical data.

Do you have the manufacturer datasheet for this model? Send it with the enquiry form — we check it and name the source.

IMO ApprovedYes
Inspection

Inspector Detail

Common issues

  • Scrubber tower internal corrosion from acidic wash water, especially at weld seams and demister
  • Demister/mist eliminator fouling or damage reducing droplet removal efficiency
  • Wash water pump wear/cavitation from continuous seawater duty
  • Spray nozzle/header blockage or erosion affecting SO2 removal efficiency
  • Bypass/3-way valve leakage or actuator failure
  • Effluent monitoring (PAH, turbidity, pH) sensor drift or fouling
  • Coating/lining breakdown inside the scrubber tower and overboard discharge line

Inspection checklist

  • Internal visual inspection of scrubber tower lining/coating for corrosion or breakdown at scheduled openings
  • Check demister condition and cleanliness
  • Function test wash water pumps, valves and bypass system
  • Verify continuous emission monitoring system (SO2/CO2 ratio) calibration
  • Check effluent monitoring (pH, PAH, turbidity, nitrate) sensor calibration and discharge compliance
  • Inspect spray nozzles/headers for blockage or erosion
  • Check overboard discharge line and non-return valves for corrosion/leakage
  • Verify EGCS bypass event documentation and record-keeping per MEPC.259(68)

Service intervals

CEMS/effluent monitoring sensor calibrationper maker's manual, typically every 3-6 months
Wash water pump inspection/overhaulannually or per condition
Internal tower inspection (coating/lining condition)at Intermediate/Renewal Survey, or per maker's schedule
Demister cleaning/inspectionevery 3-6 months depending on fuel sulphur content and running hours
Spray nozzle inspection/cleaningevery 6-12 months

Typical intervals for this design class, not the manufacturer’s figures for your model. The manufacturer’s manual is binding.

Critical spares

  • Wash water pump seal/impeller kit
  • Demister pad/elements
  • Spray nozzle set
  • Effluent monitoring sensor (pH/PAH/turbidity) replacement units
  • Bypass valve actuator seal kit

Safety

  • Acidic wash water - PPE and ventilation required when opening the scrubber tower or handling effluent samples
  • Confined space entry for internal tower inspection - full confined space procedure required
  • SO2/exhaust gas exposure risk if the system is opened while connected to a running engine exhaust
  • Overboard discharge must remain within MEPC.259(68) limits - unauthorised bypass use is a compliance and environmental breach

Class survey

Exhaust gas cleaning systems require an approved EGCS Technical Manual on board and are checked against MEPC.259(68): continuous monitoring of SO2/CO2 ratio and washwater parameters (pH, PAH, turbidity), with records reviewed at Annual/Renewal Survey. Class also checks bypass event logging and that any bypass use is justified and recorded per the approved manual.

Classification

DNV type approval

Listed in the DNV Approval Finder at the time we recorded it. The certificate is issued by DNV, not by us; check its current status at DNV.

CertificateMEDG0000120
Open the certificate at DNV
Need this part?

Request a quote for this model.

Free of charge — send us your request for Langh Tech equipment. Our team checks it and replies by e-mail.

For marine equipment hardly any maker or authorised dealer will name a price while the vessel is unknown. With the vessel details, availability and price can be settled faster; without them we may have to ask first, which costs a few days. If you are not allowed to name the vessel, a photo of the rating plate is enough — attach it below or send it as a reply to our confirmation e-mail.

Your contact details are not published. No account required.
Related models

Also in SOx Scrubber.

Other models of the same equipment type, Langh Tech first.

By manufacturer Wärtsilä MossYara MarineEcoSprayME ProductionLangh TechHyundai Heavy Industries Power SystemsPanasiaZHEJIANG ENERGY MARINE ENVIRONMENTAL TECHNOLOGY CO.,LTDAndritz MarineHI AIR KOREA Co., Ltd.Alfa LavalPacific Green MarineCR OceanMitsubishi Heavy IndustriesClean Marine ASAll manufacturersSpare parts by equipmentNew here? Create a free account Can't read the plate? Try the nameplate scanner All Langh Tech models More like 100SC1 Open loop scrubber installed onboard RIO CHARLESTON (IMO: 9362449)
More than the data sheet shows

We answer by e-mail, never with an automatic reply.

Tell us what you need for this Langh Tech 100SC1 Open loop scrubber installed onboard RIO CHARLESTON (IMO: 9362449) — a part, a service call, a second opinion. Are you Langh Tech? Claim this brand page.

Service engineer? Write the day report for this 100SC1 Open loop scrubber installed onboard RIO CHARLESTON (IMO: 9362449) in OceanSphere Work — photos, hours and parts, as a PDF for the owner. Try it free for 14 days →

Frequently asked

Questions that come up with this equipment.

Is this model's data free?

Yes. Specifications, documents and service notes for this model are readable without an account. An account adds saved searches and requests, nothing is taken away.

Can you find a part for this exact model?

Yes. Tell us the manufacturer, the model and what you need — a person reads every request and replies by e-mail.

The specifications look wrong — what now?

Send us the nameplate or the correct value. We check it against the manufacturer datasheet or class-society record and update the page.