Brandschottplatte · Schiffsstruktur und Ausrüstung
The Norac F-300 A60 is an A-60 fire division product covered by DNV MED certificate MEDB00005VR, supplied as an approved floor construction. It forms part of a ship's passive fire protection by limiting heat and fire spread through deck divisions. It is installed in accommodation and service decks as part of an A-class division.
Haben Sie das Herstellerdatenblatt zu diesem Modell? Schicken Sie es mit dem Anfrageformular — wir prüfen es und nennen die Quelle.
Was unsere Servicearbeit und die Herstellerunterlagen zum Betrieb dieses Modells sagen.
Treat the F-300 A60 as part of the vessel's passive fire-protection arrangement. During accommodation and fire-division inspections, check accessible edges, penetrations, repair areas and signs of water ingress or corrosion. Any opening made for cable, pipe or outfitting work should be reinstated with materials and details accepted for the approved floor construction. If panels or insulation are removed, record their original arrangement and verify that the rebuilt section matches the approved design. Fire-test construction details, material thicknesses and repair limits must be taken from Norac and vessel approval documentation rather than estimated onboard.
| General condition check | annual survey |
|---|---|
| Full fire division integrity check (joints, penetrations, fixings) | at Special Survey / drydocking |
Typische Intervalle für diese Bauart, keine Herstellerangabe für Ihr Modell. Verbindlich ist das Handbuch des Herstellers.
Note: the listed product type ('Fire Hose') does not match this item - the manufacturer and product naming ('F-300 A60') indicate a fire-rated insulation/division panel system used to achieve an A60 rating, not a fire hose. Class checks that field penetrations and repairs to A60 divisions are documented and fire-stopped per an approved method; undocumented alterations are a frequent deficiency finding.
For vessels with extensive F-300 installations, useful repair stock includes approved replacement cassettes, the specified insulation components, compatible edge or fixing materials and the approved sealing products used in the certified construction. Keep product identification and certificates with the repair stock so that a refit team does not substitute visually similar building materials. Final decorative floor coverings are separate from the fire-rated structural floor system and should be stocked according to the vessel interior specification.
Im DNV Approval Finder gelistet, Stand unserer Erfassung. Das Zertifikat stellt DNV aus, nicht wir; den aktuellen Status prüfen Sie bei DNV.
Kostenlos — senden Sie uns Ihre Anfrage zu NORAC A/S-Ausrüstung. Unser Team prüft sie und antwortet per E-Mail.
Weitere Modelle desselben Ausrüstungstyps, zuerst NORAC A/S.
Sagen Sie uns, was Sie für diesen NORAC A/S F-300 A60 benötigen — ein Ersatzteil, einen Serviceeinsatz, eine zweite Meinung. Sind Sie NORAC A/S? Diese Herstellerseite beanspruchen.
Servicetechniker? Schreiben Sie den Tagesbericht für diesen F-300 A60 in OceanSphere Work — Fotos, Stunden und Teile, als PDF für den Reeder. 14 Tage kostenlos testen →
Ja. Technische Daten, Dokumente und Servicehinweise zu diesem Modell sind ohne Konto lesbar. Ein Konto bringt gespeicherte Suchen und Anfragen dazu, es nimmt nichts weg.
Ja. Nennen Sie uns Hersteller, Modell und Bedarf — ein Mensch liest jede Anfrage und antwortet per E-Mail.
Schicken Sie uns das Typenschild oder den richtigen Wert. Wir prüfen ihn gegen das Herstellerdatenblatt oder den Klassifikationsdatensatz und aktualisieren die Seite.