Class-certified type (DNV register) · technical data sheet not yet verified​​⁠⁠‌⁠​⁠⁠‌⁠​‍‍‌‍⁠‌⁠⁠

B-15 Class Bulkhead, type "K-600 panel system". Category: A' & 'B' Class divisions fire integrity: 'B' class divisions. Module: B. Manufacturer: NORAC A/S.

Inspection

Inspector Detail

Common issues

  • Panel joint or insulation degradation from moisture ingress or mechanical damage, compromising fire rating
  • Unsealed or poorly re-sealed penetrations (cables, pipes) added through the division after the original installation
  • Corrosion of steel core panels or support frames at deck edges and bilge-adjacent areas
  • Loose or missing fasteners at panel seams reducing structural integrity of the division
  • Coating/paint damage exposing insulation core to moisture
  • Fire door or hatch seals degrading where they interface with the panel system
  • Unauthorised cutting or drilling through the division during later outfitting or repair work

Inspection checklist

  • Visual inspection for dents, holes, or other physical damage to panel surfaces
  • Check all cable/pipe penetrations through the division are properly fire-stopped
  • Verify panel joints and seams are intact and sealed
  • Check for corrosion at the panel base/deck interface
  • Confirm no unauthorised openings or modifications since the last survey
  • Verify adjacent fire doors close and seal correctly
  • Cross-check the installed division configuration against the approved fire control plan

Service intervals

General visual condition checkat each fire/safety round per the SMS
Detailed inspection including penetrationsannually
Coating/corrosion touch-upcondition-based
Fire control plan cross-checkat each class survey

Typical intervals for this design class, not the manufacturer’s figures for your model. The manufacturer’s manual is binding.

Critical spares

  • Replacement panel sections matching the approved type and thickness
  • Fire-rated penetration seals/collars
  • Approved panel joint sealant
  • Fasteners matching the original specification
  • Approved fire-rated touch-up coating

Safety

  • A compromised fire division allows fire and smoke to spread between spaces - any breach must be made good and reported without delay
  • Do not cut, drill, or otherwise penetrate the panel without an approved method - this can void the B-class fire rating
  • Insulation core materials may present a handling hazard if damaged or disturbed - follow the safety data sheet for the panel core material

Class survey

Note on source data: the catalogued 'typ' field ('CO2 Fixed System') does not match this product. The certificate (UK MCA 80180/A0) and description identify a B-15 class fire division bulkhead panel system ('K-600 panel system') - a passive fire protection product, not an active CO2 extinguishing system. The content above addresses the actual product. 'B' class divisions are periodically verified against the approved fire control plan at each survey; any penetration, modification, or damage since the last survey must be documented and reinstated to the approved fire rating before certification is confirmed.

Estimated lifetime: Passive fire division panels are generally rated for the vessel's structural life with no fixed renewal interval; renewal is damage- or condition-driven rather than time- or hours-based.

Need this part?

Request a quote for this model.

Free of charge — send us your request for NORAC A/S equipment. Our team checks it and replies by e-mail.

For marine equipment hardly any maker or authorised dealer will name a price while the vessel is unknown. With the vessel details, availability and price can be settled faster; without them we may have to ask first, which costs a few days. If you are not allowed to name the vessel, a photo of the rating plate is enough — attach it below or send it as a reply to our confirmation e-mail.

Your contact details are not published. No account required.
Related models

Also in Fire Division Panel.

Other models of the same equipment type, NORAC A/S first.

By manufacturer BIP Industries Co., Ltd. GoseongHuanan Building Materials (Shenzhen)RockwoolThermal Ceramics UKUNIFRAXKCC Corporation Ltd. Gimcheon PlantShanghai ABM Rock WoolSejin Technical Industries Co., Ltd.CBG Systems InternationalTianjin Haimen Building Material Co., Ltd.KAEFER Schiffsausbau GmbHTianjin Huali Thermal Insulation Building Material Co., Ltd.Jiangsu Haojun Huake Housing Industrial Co., Ltd.NORAC A/SJiangyin Haisheng Marine Outfitting & Decoration Co., Ltd.All manufacturersSpare parts by equipmentNew here? Create a free account Can't read the plate? Try the nameplate scanner More like B-15 Class Bulkhead, type "K-600 panel system"
More than the data sheet shows

We answer by e-mail, never with an automatic reply.

Tell us what you need for this NORAC A/S B-15 Class Bulkhead, type "K-600 panel system" — a part, a service call, a second opinion. Are you NORAC A/S? Claim this brand page.

Service engineer? Write the day report for this B-15 Class Bulkhead, type "K-600 panel system" in OceanSphere Work — photos, hours and parts, as a PDF for the owner. Try it free for 14 days →

Frequently asked

Questions that come up with this equipment.

Is this model's data free?

Yes. Specifications, documents and service notes for this model are readable without an account. An account adds saved searches and requests, nothing is taken away.

Can you find a part for this exact model?

Yes. Tell us the manufacturer, the model and what you need — a person reads every request and replies by e-mail.

The specifications look wrong — what now?

Send us the nameplate or the correct value. We check it against the manufacturer datasheet or class-society record and update the page.