F-300 A60
F-300 A60 by Norac AS. DNV MED certificate MEDB00005VR.
Inspector Detail
▸
Common issues
- Gaps or open seams between insulation panels/sections reducing fire division integrity
- Compression or settling of the insulation behind the cladding over time
- Corrosion of steel facing or fixing brackets, particularly where condensation forms
- Damage from mechanical impact or from unauthorized penetrations (cables, pipes) that are not fire-stopped to the same rating
- Moisture ingress degrading the insulation core
- Sagging where fixings have failed
Inspection checklist
- Visual check of panel joints/seams and sealant condition
- Check fixing brackets/pins for corrosion or looseness
- Verify any penetrations added since installation have been properly fire-stopped and documented
- Check for physical damage, dents, or missing sections
- Check insulation is present and intact at inspection hatches or access points
- Compare the installed configuration against the approved fire division drawing
Service intervals
| General condition check | annual survey |
| Full fire division integrity check (joints, penetrations, fixings) | at Special Survey / drydocking |
Critical spares
- Matching panel/insulation sections of the correct type and thickness
- Approved fixing brackets and pins
- Approved fire-rated sealant for joints and penetrations
Safety
- Any field penetration or modification to an A-class division must be fire-stopped using an approved method or the division rating is compromised - this is a common and serious survey/PSC finding
- Mineral wool or insulation dust requires PPE per the safety data sheet during repair work
- Do not use unapproved sealants or coatings that add fuel load to the division
Class survey
Note: the listed product type ('Fire Hose') does not match this item - the manufacturer and product naming ('F-300 A60') indicate a fire-rated insulation/division panel system used to achieve an A60 rating, not a fire hose. Class checks that field penetrations and repairs to A60 divisions are documented and fire-stopped per an approved method; undocumented alterations are a frequent deficiency finding.
Components & Design
Component data being added…
Technical Data
🤖 Ask about this model
One free question — answered like a marine engineer. No account needed.
Suppliers & Spare Parts
Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.
📄 Request sourcing links & documentsCases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.
Start free trial →Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.
Maritime Network →