OceanSphereENGINES
Library› Engine Room› Main Engines (2-Stroke)› Main Engine 2-Stroke› MAN Energy Solutions S50ME-GI

S50ME-GI

Main Engine 2-Stroke · Main Engines (2-Stroke)

Technical data from manufacturer or class sources · not yet verified by a person​​‍​⁠⁠‍​‌⁠⁠‍‍‌​‍‍⁠‌‌
5 / 8Cylinders
500 mmBore
2,214 mmStroke
5,450-9,960 kW (5-8 Cyl)Capacity
LNG (Dual-Fuel) / HFO / MGOMedium

Crew, engineers, and operators on board ships depend on reliable marine engines to ensure safe and efficient operations. The S50ME-GI by MAN Energy Solutions is a dual-fuel engine designed for vessels requiring flexibility in fuel use. With its high-pressure gas injection capabilities, it operates on LNG, HFO, VLSFO, or MGO, offering IMO Tier III compliance in gas mode. This engine supports 5 to 8 cylinders, delivering power from 5,450 to 9,960 kW at a direct drive configuration. The ME-GI family, launched since 2015, is known for its robust design and flexibility but may experience common failures such as gas admission valve issues or fuel oil/gas changeover problems during rapid transitions. Maintenance includes regular checks on the gas supply system and standard intervals for the engine, with critical spare parts like GAVs taking approximately 4-6 weeks for delivery.

Specifications

Technical data.

Do you have the manufacturer datasheet for this model? Send it with the enquiry form — we check it and name the source.

Type2-Stroke Dual-Fuel Engine (High-Pressure Gas Injection)
TierIMO Tier III (gas mode)
Drive TypeDirect Drive
ConstructionME-GI: High-pressure gas injection (300 bar), crosshead
Service

Service notes.

What our service work and the manufacturer documentation say about keeping this model running.

GAV: 6,000-8,000 hrs. Gas supply system: per Wärtsilä/MAN FGSS schedule. Otherwise standard ME-C intervals.

Inspection

Common failures & inspection points

Inspection

Inspector Detail ✓ verified

Designation decoded

S für Super-Long-Stroke, 50 für Bohrung 500 mm, ME für elektronische Steuerung, GI für Gas Injection — Hochdruck-Dual-Fuel mit LNG-Einspritzung bei 300 bar im Dieselprozess. Specs: 5-8 Zylinder, Hub 2214 mm, IMO Tier III im Gasmodus.

Background

Der S50ME-GI ist der effizienteste LNG-Dual-Fuel-2-Takt-Motor in der 500-mm-Klasse. Die Hochdruck-Gaseinspritzung bei 300 bar im Diesel-Cycle eliminiert praktisch den Methanschlupf — ein entscheidender Vorteil gegenüber Niederdruck-Otto-Cycle-Motoren (GA). Standard auf LNG-Carrier-Neubauten und zunehmend auf Containerschiffen. Im Gasmodus Tier III ohne SCR/EGR erreichbar.

Calculated metrics

Stroke to bore ratio4.43

Inspector checklist

Laufzeug & Tribologie
  • Zylinderlaufbuchse: 500 mm Bohrung, S/B 4.43 — hohe Seitenkräfte am Kreuzkopf, Verschleißprofil mit besonderem Augenmerk auf Thrust/Anti-Thrust
  • Kolbenringe: Im GI-Modus saubere Verbrennung → Liner-Polishing-Risiko bei dauerhaftem Gasbetrieb beobachten
  • Kreuzkopf-Lager: Bei S/B 4.43 erhöhte Querkräfte — Lagerspiel und Ölfilm
ME-Steuerung & Hydraulik
  • FIVA-Ventile: Hydraulikdruck und Schaltzeiten — GI-Modus erfordert zylinderindividuelle Gasmengen-Regelung
  • HPS: Kapazität für duale Steuerung (Diesel + Gas)
  • PMI-Online: Verbrennungskurven Diesel vs. GI vergleichen
  • ECS: GI-spezifische Software und Sicherheitslogik
GI Hochdruck-Gas-System
  • Gas Valve Unit (GVU): Block-and-Bleed-Dichtheitsprüfung — bei 300 bar Gasdruck sicherheitskritisch
  • HP-Gas-Kompressoren: Wartungsintensivste Komponente — Schwingung, Ventilplatten, Ölanalyse
  • Gasinjektionsventile am Zylinderkopf: Düsenerosion durch 300-bar-Gasstrahl, Verkokung bei Diesel-Gas-Wechsel
  • Doppelwandige Rohrleitungen: Annulus-HC-Monitoring, Ventilationsluft prüfen
Sicherheitssysteme
  • HC-Detektoren: Kalibrierung aller Sensoren in Maschinenraum und Doppelwandräumen
  • ESD: Gas-Trip-Sequenz testen — Diesel-Fallback innerhalb Sekunden
  • Ventilation: EX-Zonen-Konzept gegen IGF-Code
  • Inertgas/N2-Überwachung um Gasleitungen
Dichtungssysteme
  • Gasinjektions-Dichtungen: Höchste Sicherheitsstufe — Undichtigkeit = sofortiger Gas-Trip
  • Stopfbuchse: Standard-Überwachung, Drainage-Trend
  • Auslassventil: Dichtring und Spindel

Logbook reference values

ParameterExpectedDeviation means
Abgastemperatur nach Zylinder350-420 °C (Diesel ≈ GI) bei 85% MCRSpread >20 °C → Gasinjektionsventil oder Pilotdüse prüfen
HP-Gasdruck vor Injektor250-350 barDruckschwankungen → HP-Kompressor oder Regelventil
Pilot-Fuel-Anteil2-5% im GI-ModusAnstieg → Gasinjektions-Problem, Zylinder fällt auf Diesel zurück
Zylinderöl-Feed-Rate0.5-0.8 g/kWh (GI-Modus, schwefelarmer Betrieb)BN-Anpassung an Pilot-Schwefelgehalt
Methan-Emission (Abgas)GI: nahezu Null MethanschlupfMessbarer Methanschlupf → Gasinjektions-Timing oder -Menge fehlerhaft

Common Failure Modes

  • HP-Kompressor-Ausfall

    Symptoms: Gas-Trip, automatischer Diesel-Fallback, Kompressor-Alarm

    Causes: Ventilplatten-Bruch, Lager-Verschleiß, Inter-Cooler-Problem

    Preventive: Ventilplatten nach Hersteller-Intervall tauschen, Schwingungsmonitoring, Redundanz nutzen

  • Gasinjektionsventil-Verkokung

    Symptoms: Leistungsabfall einzelner Zylinder im GI-Modus, PMI-Asymmetrie

    Causes: Verbrennungsrückstände bei Diesel-Gas-Wechsel, Düsenspitzen-Erosion, Unzureichende Kühlung

    Preventive: Gasinjektoren in festen Intervallen tauschen, MGO statt HFO als Pilotbrennstoff bevorzugen

  • FIVA-Ventil-Leckage

    Symptoms: Timing-Drift, Abgastemperatur-Spreizung

    Causes: Steueröl-Kontamination, Dichtungsverschleiß

    Preventive: Steueröl <10 µm filtrieren

Expert tips

  • GI vs. GA: Der entscheidende Vorteil der GI-Technologie ist KEIN Methanschlupf — für CII-Rating und IMO GHG-Strategie ist das ein game changer gegenüber Otto-Cycle-Motoren
  • HP-Kompressor-Redundanz ist essentiell: Typisch 2×50% oder 3×50% — ein Kompressor-Ausfall darf nicht zum Gas-Trip des gesamten Motors führen
  • Bei S/B 4.43 und GI-Modus: Die saubere Verbrennung + hohe Seitenkräfte machen die Zylinderöl-Wahl besonders wichtig — Gas-Motor-spezifisches Öl verwenden

Related components

  • HP-Gas-Kompressor (2-3× redundant)
  • MAN TCA-Turbolader
  • FGSS — LNG-Tank, Verdampfer, BOG-Management
  • Pilot-Fuel-System — Aufbereitung und Filtration
  • HPS-System
  • Alpha Lubricator — Gas-Motor-Öl

Classification & regulatory

IMO Tier III im Gasmodus ohne SCR/EGR — der GI-Motor erreicht Tier III inhärent durch niedrigere Verbrennungstemperaturen. IGF-Code Compliance obligatorisch. EEDI/CII: GI reduziert CO2 um 20-25% gegenüber HFO, kein Methanschlupf-Malus.

Reference content for inspector orientation. Always verify against manufacturer's manual, latest service letters and class society requirements.

Spares

Replacement Parts

Spare parts notes

MAN PrimeServ. GAV-Teile: 4-6 Wochen. FGSS-Teile: separat über FGSS-Hersteller.

Need this part?

Request a quote for this model.

Free of charge — send us your request for MAN Energy Solutions equipment. Our team checks it and replies by e-mail.

For marine equipment hardly any maker or authorised dealer will name a price while the vessel is unknown. With the vessel details, availability and price can be settled faster; without them we may have to ask first, which costs a few days. If you are not allowed to name the vessel, a photo of the rating plate is enough — attach it below or send it as a reply to our confirmation e-mail.

Your contact details are not published. No account required.
Related models

Also in Main Engine 2-Stroke.

Other models of the same equipment type, MAN Energy Solutions first.

By manufacturer MAN Energy SolutionsWinGDSulzerWärtsiläMitsubishiElectro-Motive DieselHyundaiDoosanHudong-ZhonghuaJapan EngineAkasaka Diesel (Mitsubishi UEC licensed)National Railway EquipmentHSD EngineKawasakiProgress Rail Locomotive, Inc.All manufacturersSpare parts by equipmentNew here? Create a free account Can't read the plate? Try the nameplate scanner All MAN Energy Solutions models More like S50ME-GI
More than the data sheet shows

We answer by e-mail, never with an automatic reply.

Tell us what you need for this MAN Energy Solutions S50ME-GI — a part, a service call, a second opinion. Are you MAN Energy Solutions? Claim this brand page.

Service engineer? Write the day report for this S50ME-GI in OceanSphere Work — photos, hours and parts, as a PDF for the owner. Try it free for 14 days →

Frequently asked

Questions that come up with this equipment.

Is this model's data free?

Yes. Specifications, documents and service notes for this model are readable without an account. An account adds saved searches and requests, nothing is taken away.

Can you find a part for this exact model?

Yes. Tell us the manufacturer, the model and what you need — a person reads every request and replies by e-mail.

The specifications look wrong — what now?

Send us the nameplate or the correct value. We check it against the manufacturer datasheet or class-society record and update the page.