The Alfa Laval S.p.A. Aalborg-XW-A3 is an entry in the Alfa Laval Aalborg XW exhaust-gas economizer family. The Aalborg XW is a water-tube, forced-circulation exhaust-gas economizer used to recover heat from diesel-engine exhaust gas and transfer it into a steam or hot-water circuit according to the installed plant arrangement. It is normally installed in the exhaust-gas path downstream of a main or auxiliary diesel engine and connected to a steam drum or auxiliary boiler system as required by the vessel design. The heating surface uses gilled water tubes, and the unit is designed for marine exhaust-gas conditions where vibration, pulsation and soot deposition must be considered. The A3 suffix identifies the variant recorded in this library, but the provided source does not define how that designation changes heating surface, dimensions or capacity. The exact approved design pressure and operating conditions must be confirmed from the equipment nameplate, class documentation and Alfa Laval data. Exact steam capacity, gas-side limits, circulation requirements and cleaning arrangements must be taken from the manufacturer documentation for the installed economizer.

Specifications

Technical data.

Do you have the manufacturer datasheet for this model? Send it with the enquiry form — we check it and name the source.

Model numberAalborg-XW-A3
Evaporation1200 kg/h
Design pressure10 bar
Weight (dry)3200 kg
Applicationexhaust gas economizer
Heating surface28 m2
StandardsEU PED 2014/68/EU, classification by IACS members
Service

Service notes.

What our service work and the manufacturer documentation say about keeping this model running.

Trend exhaust-gas temperatures and gas-side pressure drop where instrumentation is fitted, because changes can indicate fouling. Inspect gilled tubes, casing, expansion joints, supports and soot-blower or cleaning equipment for deposits, leakage, corrosion and damage. Verify forced-circulation pumps, valves, drum level control and protective interlocks associated with the economizer. After water washing or maintenance, ensure the gas side is properly drained and the unit is returned to service in accordance with the approved procedure. Use Alfa Laval and class-approved documentation for exact water chemistry requirements, pressure limits, inspection criteria and safety-device settings.

Inspection

Common failures & inspection points

Spares

Replacement Parts

Spare parts notes

Keep critical spares for the installed soot-blowing or cleaning equipment, circulation-pump seals and other auxiliary components according to the vessel's redundancy philosophy. Gaskets, instrumentation items and approved repair materials should match the exact economizer specification. Pressure-part repairs and replacement tube work require approved procedures and materials rather than generic onboard substitutions.

Need this part?

Request a quote for this model.

Free of charge — send us your request for Alfa Laval equipment. Our team checks it and replies by e-mail.

For marine equipment hardly any maker or authorised dealer will name a price while the vessel is unknown. With the vessel details, availability and price can be settled faster; without them we may have to ask first, which costs a few days. If you are not allowed to name the vessel, a photo of the rating plate is enough — attach it below or send it as a reply to our confirmation e-mail.

Your contact details are not published. No account required.
Related models

Also in Exhaust Gas Boiler.

Other models of the same equipment type, Alfa Laval first.

By manufacturer Alfa LavalAlfa Laval AalborgSunrodVolcano (Bono)KangrimKEPCOSAACKEMiharaParat HalvorsenKockum SonicsLC Eldridge Sales Co., Ltd.Rubber DesignAll manufacturersSpare parts by equipmentNew here? Create a free account Can't read the plate? Try the nameplate scanner All Alfa Laval models More like Aalborg-XW-A3
More than the data sheet shows

We answer by e-mail, never with an automatic reply.

Tell us what you need for this Alfa Laval Aalborg-XW-A3 — a part, a service call, a second opinion. Are you Alfa Laval? Claim this brand page.

Service engineer? Write the day report for this Aalborg-XW-A3 in OceanSphere Work — photos, hours and parts, as a PDF for the owner. Try it free for 14 days →

Frequently asked

Questions that come up with this equipment.

Is this model's data free?

Yes. Specifications, documents and service notes for this model are readable without an account. An account adds saved searches and requests, nothing is taken away.

Can you find a part for this exact model?

Yes. Tell us the manufacturer, the model and what you need — a person reads every request and replies by e-mail.

The specifications look wrong — what now?

Send us the nameplate or the correct value. We check it against the manufacturer datasheet or class-society record and update the page.