Caterpillar

Cat C9.3 Marine Generator Set

Caterpillar Cat C9.3 Marine Generator Set — Marine generator set for commercial vessels and yachts, 50/60 Hz, EPA Tier 3 / IMO II.

Components & Design

Component data being added…

Technical Data

capacity kVA 185 – 300 ekW (231 – 375 kVA); 50 Hz HEx/keel: 200/250 ekW; 60 Hz HEx/keel: 250/300 ekW; radiator: 185/235 ekW (50Hz), 224/274 ekW (60Hz)
speed rpm 1500 / 1800
weight kg 2157 – 2313

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Check and change lubricating oil and oil filters at manufacturer-specified intervals (typically 250–500 operating hours)

Check and change lubricating oil and oil filters at manufacturer-specified intervals (typically 250–500 operating hours)

Inspect and replace fuel filters (primary and secondary) and check fuel system for leaks, water contamination, and microbial growth

Inspect and replace fuel filters (primary and secondary) and check fuel system for leaks, water contamination, and microbial growth

Inspect and test cooling system: heat exchanger, raw-water pump impeller, keel cooler or radiator; check coolant concentration, zinc anodes, and hose condition

Inspect and test cooling system: heat exchanger, raw-water pump impeller, keel cooler or radiator; check coolant concentration, zinc anodes, and hose condition

Inspect air intake system: air filter condition, turbocharger operation, intercooler/aftercooler for fouling or corrosion

Inspect air intake system: air filter condition, turbocharger operation, intercooler/aftercooler for fouling or corrosion

Test and inspect the alternator/generator: insulation resistance (Megger test), bearing condition, voltage regulation, and excitation system

Test and inspect the alternator/generator: insulation resistance (Megger test), bearing condition, voltage regulation, and excitation system

Check all belts, vibration mounts, flexible couplings, and exhaust system (wet exhaust mixing elbow, silencer, and through-hull fittings) for wear, corrosion, o

Check all belts, vibration mounts, flexible couplings, and exhaust system (wet exhaust mixing elbow, silencer, and through-hull fittings) for wear, corrosion, or leakage

Verify battery condition, starter motor function, control panel alarms, shutdown circuits, and emergency stop system

Verify battery condition, starter motor function, control panel alarms, shutdown circuits, and emergency stop system

Record and verify classification society compliance: review logbooks, check certificates (DNV, Lloyd's, BV, etc.), and confirm emissions compliance (IMO II/III,

Record and verify classification society compliance: review logbooks, check certificates (DNV, Lloyd's, BV, etc.), and confirm emissions compliance (IMO II/III, EPA Tier) remains valid

Type-general inspection and maintenance points for this equipment category — not model-specific.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →
Equipment Model #152892 · ✓ still in production