"> SAB Georg Schünemann GmbH Duplex Filter F725
⚓ Working on this equipment?
Ask the AI troubleshooter, log your hours on board and turn them into invoice-ready service reports — for this exact model.
Start free — 14 days →
No credit card required
SAB Georg Schünemann GmbH

Duplex Filter F725

SAB Georg Schünemann GmbH Duplex Filter F725 — Multi-purpose welded duplex filter for liquid media including fuel and fuel oil. Designed for high volume flows at elevated pressures with continuous operation during cleaning. Used in marine and industrial fuel oil systems..

Components & Design

Component data being added…

Technical Data

flow m3h max. 280
micron rating 80–1000 µm (fabric/perforated plate); 10–60 µm on request
pressure bar 10 / 16
connection DN DN50–DN200
housing material 1.4541, P235GH, 1.4571

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Check and clean or replace strainer insert (basket or ring-type strainer) at defined differential pressure or time intervals

Check and clean or replace strainer insert (basket or ring-type strainer) at defined differential pressure or time intervals

Inspect and test the duplex changeover valve (two-way valve / ball valve) for smooth, leak-free switching between filter chambers

Inspect and test the duplex changeover valve (two-way valve / ball valve) for smooth, leak-free switching between filter chambers

Verify differential pressure indicator readings and calibrate or replace sensor/indicator as required

Verify differential pressure indicator readings and calibrate or replace sensor/indicator as required

Inspect filter housing, covers, and sealing surfaces for corrosion, erosion, or damage; replace O-rings and gaskets

Inspect filter housing, covers, and sealing surfaces for corrosion, erosion, or damage; replace O-rings and gaskets

Check optional magnetic insert for accumulated ferrous particles; clean or replace as needed

Check optional magnetic insert for accumulated ferrous particles; clean or replace as needed

Inspect sacrificial anode (if fitted) and replace when consumption exceeds 50% to ensure cathodic protection of housing

Inspect sacrificial anode (if fitted) and replace when consumption exceeds 50% to ensure cathodic protection of housing

For automatic self-cleaning filters: verify correct function of pneumatic or electric drive unit, flush valve, and backwash cycle initiation (differential press

For automatic self-cleaning filters: verify correct function of pneumatic or electric drive unit, flush valve, and backwash cycle initiation (differential pressure trigger and/or timer)

Flush filter housing and drain accumulated sludge/sediment from drain valve after each cleaning or at scheduled intervals

Flush filter housing and drain accumulated sludge/sediment from drain valve after each cleaning or at scheduled intervals

Type-general inspection and maintenance points for this equipment category — not model-specific.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →
Equipment Model #152452 · ✓ still in production