BOLL & KIRCH Filterbau GmbH

BOLLFILTER Duplex Type 2.04.5

BOLL & KIRCH Filterbau GmbH BOLLFILTER Duplex Type 2.04.5 — Duplex (double) filter for fuel oil, lubricating oil, water, and chemical liquids in suction and pressure lines. Two chambers enable changeover under pressure without process shutdown. Used on ships and in industrial plants to protect downstream components. Available with star-pleated or basket elements..

BOLL & KIRCH Filterbau GmbH BOLLFILTER Duplex Type 2.04.5

Components & Design

Component data being added…

Technical Data

micron rating 10 µm – 5 mm
pressure bar PN 25 (nodular cast iron); PN 19 (stainless steel casting); higher on request
connection DN DN 25 – DN 80 (DIN flanges, approx. 1"–3")
housing material nodular cast iron or stainless steel casting
design codes AD2000
changeover plug changeover valve

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Check differential pressure indicator reading against manufacturer-specified maximum allowable differential pressure (typically triggers at 0.5–1.0 bar); replac

Check differential pressure indicator reading against manufacturer-specified maximum allowable differential pressure (typically triggers at 0.5–1.0 bar); replace or clean filter elements if exceeded.

Inspect and test the automatic backflushing / changeover mechanism (motorised valve, turbine drive, or compressed-air solenoid) for correct actuation, timing, a

Inspect and test the automatic backflushing / changeover mechanism (motorised valve, turbine drive, or compressed-air solenoid) for correct actuation, timing, and completeness of backflush cycle.

Verify integrity and cleanliness of filter elements (wire-mesh candles, star-pleated elements, or basket strainers): inspect for holes, deformation, blinding, o

Verify integrity and cleanliness of filter elements (wire-mesh candles, star-pleated elements, or basket strainers): inspect for holes, deformation, blinding, or corrosion; replace per manufacturer interval.

Check all seals, O-rings, and gaskets on filter heads, element seats, and drain valves for leaks, hardening, or extrusion; renew if any fuel oil weepage is dete

Check all seals, O-rings, and gaskets on filter heads, element seats, and drain valves for leaks, hardening, or extrusion; renew if any fuel oil weepage is detected.

Inspect and clean drain valve(s) and flush / drain lines; confirm that backflush discharge lines are clear and not blocked by residues or solidified heavy fuel

Inspect and clean drain valve(s) and flush / drain lines; confirm that backflush discharge lines are clear and not blocked by residues or solidified heavy fuel oil.

Verify correct operation of the duplex changeover valve (plug, ball, or damper type): smooth actuation under pressure, no internal bypass leakage past valve sea

Verify correct operation of the duplex changeover valve (plug, ball, or damper type): smooth actuation under pressure, no internal bypass leakage past valve seals to the stand-by chamber.

Check heating medium circuit (steam or thermal oil jacket) for correct temperature (HFO systems: 80–100 °C supply, 130–160 °C booster), circulation flow, and ab

Check heating medium circuit (steam or thermal oil jacket) for correct temperature (HFO systems: 80–100 °C supply, 130–160 °C booster), circulation flow, and absence of leaks.

Confirm classification-society-required maintenance records (e.g., IACS, DNV, BV, LR) are up to date; verify that any pressure-vessel inspection certificates fo

Confirm classification-society-required maintenance records (e.g., IACS, DNV, BV, LR) are up to date; verify that any pressure-vessel inspection certificates for the filter housing are valid and that safety relief valves on by-pass circuits are tested.

Type-general inspection and maintenance points for this equipment category — not model-specific.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →
Equipment Model #152440 · ✓ still in production