BOLL & KIRCH Filterbau GmbH BOLLFILTER Automatic Type 6.64 — Compact multi-chamber automatic self-cleaning filter for the maritime industry; filters large quantities of liquid fuel (HFO/MDO), lubricants, coolants and alkaline cleaners on cruise vessels, cargo ships, and large diesel engines. Compressed-air backflushing..

BOLL & KIRCH Filterbau GmbH BOLLFILTER Automatic Type 6.64

Components & Design

Component data being added…

Technical Data

micron rating 6–50 µm (wire-mesh and star-pleated stainless-steel candles); also listed as 6–150 µm in distributor sources
pressure bar PN 10/16 (DN 400 limited to PN 10)
temp max C 160
connection DN DN 100 – DN 400 (DIN flanges)
weight kg DN 100: 298 kg (empty); DN 150: 464 kg; DN 200: 784 kg
filter candles DN 100: 32 candles / 8,832 cm²; DN 150: 64 candles / 20,608 cm²; DN 200: 124 candles / 34,224 cm²
housing material nodular cast iron (optional nickel-plated)

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Check differential pressure indicator reading against manufacturer-specified maximum allowable differential pressure (typically triggers at 0.5–1.0 bar); replac

Check differential pressure indicator reading against manufacturer-specified maximum allowable differential pressure (typically triggers at 0.5–1.0 bar); replace or clean filter elements if exceeded.

Inspect and test the automatic backflushing / changeover mechanism (motorised valve, turbine drive, or compressed-air solenoid) for correct actuation, timing, a

Inspect and test the automatic backflushing / changeover mechanism (motorised valve, turbine drive, or compressed-air solenoid) for correct actuation, timing, and completeness of backflush cycle.

Verify integrity and cleanliness of filter elements (wire-mesh candles, star-pleated elements, or basket strainers): inspect for holes, deformation, blinding, o

Verify integrity and cleanliness of filter elements (wire-mesh candles, star-pleated elements, or basket strainers): inspect for holes, deformation, blinding, or corrosion; replace per manufacturer interval.

Check all seals, O-rings, and gaskets on filter heads, element seats, and drain valves for leaks, hardening, or extrusion; renew if any fuel oil weepage is dete

Check all seals, O-rings, and gaskets on filter heads, element seats, and drain valves for leaks, hardening, or extrusion; renew if any fuel oil weepage is detected.

Inspect and clean drain valve(s) and flush / drain lines; confirm that backflush discharge lines are clear and not blocked by residues or solidified heavy fuel

Inspect and clean drain valve(s) and flush / drain lines; confirm that backflush discharge lines are clear and not blocked by residues or solidified heavy fuel oil.

Verify correct operation of the duplex changeover valve (plug, ball, or damper type): smooth actuation under pressure, no internal bypass leakage past valve sea

Verify correct operation of the duplex changeover valve (plug, ball, or damper type): smooth actuation under pressure, no internal bypass leakage past valve seals to the stand-by chamber.

Check heating medium circuit (steam or thermal oil jacket) for correct temperature (HFO systems: 80–100 °C supply, 130–160 °C booster), circulation flow, and ab

Check heating medium circuit (steam or thermal oil jacket) for correct temperature (HFO systems: 80–100 °C supply, 130–160 °C booster), circulation flow, and absence of leaks.

Confirm classification-society-required maintenance records (e.g., IACS, DNV, BV, LR) are up to date; verify that any pressure-vessel inspection certificates fo

Confirm classification-society-required maintenance records (e.g., IACS, DNV, BV, LR) are up to date; verify that any pressure-vessel inspection certificates for the filter housing are valid and that safety relief valves on by-pass circuits are tested.

Type-general inspection and maintenance points for this equipment category — not model-specific.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →