Minimax

Sprinkler Systems (Undercover)

Minimax Sprinkler Systems (Undercover) — Office buildings, luxury hotel rooms, museums, showrooms, high-aesthetic indoor applications.

Components & Design

Component data being added…

Technical Data

Design Feature Virtually flush with ceiling for aesthetic integration
Activation Type Automatic temperature-actuated (selective activation)
System Types Wet pipe, dry pipe, pilot-operated dry systems
Control Panel ESS 5000 electronic control panel for electrically driven pumps
Coverage Only sprinklers in immediate fire proximity activate (selective)

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Valve Actuation and System Response Time

Conduct annual full trip test of deluge valves; record time from detector activation to water discharge through all nozzles; verify compliance with maximum 3-year interval requirement for full trip tests

Pressure Gauge Calibration and System Pressure Maintenance

Visually inspect pressure gauges quarterly; verify water pressure at hydraulically remote sprinkler and deluge valve inlet; confirm jockey pump maintains correct pressure (9 bar for ProCon systems, 40-90 bar for ProCon XP)

Nozzle and Sprinkler Obstruction, Corrosion, and Physical Damage

Visually inspect all open nozzles (Viking Model A, C-1, ProCon, Marine XP) for paint coverage, debris accumulation, corrosion, bent deflectors, or mechanical damage; remove random sample of sprinklers for laboratory endoscopic examination of pipe network deposits; assess residual wall thicknesses

Pipe System Internal Condition and Deposits

Perform endoscopic examination of main pipe network for internal corrosion, mineral deposits, and rust; assess hydraulic impact and remaining pipe wall thickness; conduct main drain tests to verify control valve operation; inspect all trim valves in correct open/closed positions

Fire Detection System Integration and Signal Integrity

For systems with electric or pneumatic release (TraFoProtect with UniVario/FMZ 5000, PVProtect with heat detectors, EconAqua systems): verify all detector signal paths; test short circuit detection in monitoring circuits; confirm automatic activation signal transmission under simulated fire conditions; check for line interruptions or water supply status indicator function

Type-general inspection and maintenance points for this equipment category — not model-specific.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →
Equipment Model #148847 · ✓ still in production

Wer liefert dieses Teil? 6 Betriebe im Verzeichnis · 1 aus Herstellerlisten

Cochin Fire Tech India Private Limited
Kochi, India
HIROSCANTEK INC.
Kobe, Japan
Inglasco Fire Systems B.V.
Gieterijweg 17 3089 JZ Rotterdam The Netherlands, Netherlands
MINIMAX BRANDBEVEILIGING BV
Rotterdam, Netherlands
Minimax Fire Solutions International GmbH
Germany
Minimax GmbH, Fire Protection
Glinde, Germany
Weitere aus Hersteller- und Marktplatzverzeichnissen:
Minimax Brandbeveiliging B.V. / Minimax Fire Solutions International / Marine Department · Netherlands
Alle Betriebe für Minimax ansehen →