Minimax

MXOne (Firefighting Turbine)

Minimax MXOne (Firefighting Turbine) — Airports, hangars, recycling facilities, industrial/logistics centers, energy infrastructure, chemical/petroleum industries, vehicle decks on ferries.

Components & Design

Component data being added…

Technical Data

Maximum Range (Water Mist) 37 meters certified
Maximum Range (Full Jet) 100 meters certified
Operating Temperature -15°C to +50°C
Rotation Capability 360° coverage
Spray Modes Full jet, water mist, or combination mode
Functionality 4-in-1: extinguishing, cooling, smoke extraction, pollution binding
Control Options Fully automatic or manual remote control
Installation Configurations Stationary, tower-mounted, trailer-based, or flat-rack deployable
Certification FM Global, MPA Dresden, DMT, FlameCert, bSafe tested

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Valve Actuation and System Response Time

Conduct annual full trip test of deluge valves; record time from detector activation to water discharge through all nozzles; verify compliance with maximum 3-year interval requirement for full trip tests

Pressure Gauge Calibration and System Pressure Maintenance

Visually inspect pressure gauges quarterly; verify water pressure at hydraulically remote sprinkler and deluge valve inlet; confirm jockey pump maintains correct pressure (9 bar for ProCon systems, 40-90 bar for ProCon XP)

Nozzle and Sprinkler Obstruction, Corrosion, and Physical Damage

Visually inspect all open nozzles (Viking Model A, C-1, ProCon, Marine XP) for paint coverage, debris accumulation, corrosion, bent deflectors, or mechanical damage; remove random sample of sprinklers for laboratory endoscopic examination of pipe network deposits; assess residual wall thicknesses

Pipe System Internal Condition and Deposits

Perform endoscopic examination of main pipe network for internal corrosion, mineral deposits, and rust; assess hydraulic impact and remaining pipe wall thickness; conduct main drain tests to verify control valve operation; inspect all trim valves in correct open/closed positions

Fire Detection System Integration and Signal Integrity

For systems with electric or pneumatic release (TraFoProtect with UniVario/FMZ 5000, PVProtect with heat detectors, EconAqua systems): verify all detector signal paths; test short circuit detection in monitoring circuits; confirm automatic activation signal transmission under simulated fire conditions; check for line interruptions or water supply status indicator function

Type-general inspection and maintenance points for this equipment category — not model-specific.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →
Equipment Model #148846 · ✓ still in production

Need spare parts for this model?

We know 12+ companies supplying Minimax GmbH & Co. KG MXONE(FIREFIGHTINGTURBINE). Tell us what you need — we obtain the quotations for you.

Cochin Fire Tech India Private Lim · IndiaInglasco Fire Systems B.V. · NetherlandsBreakwater International · United StatesDolphin Marine Co Ltd · United KingdomDolphin Marine Engineering & Tradi · ChinaEast Coast Ship Supply · United States +6 more

Wer liefert dieses Teil? 12 Betriebe im Verzeichnis · 1 aus Herstellerlisten

Breakwater International
Houston, United States
Cochin Fire Tech India Private Limited
Kochi, India
Dolphin Marine Co Ltd
United Kingdom
Dolphin Marine Engineering & Trading Co., Ltd
China
GMS Instruments BV
Haarlem, Netherlands
HIGH SEAS TRADING CO.
United States
HIROSCANTEK INC.
Kobe, Japan
Inglasco Fire Systems B.V.
Gieterijweg 17 3089 JZ Rotterdam The Netherlands, Netherlands
MINIMAX BRANDBEVEILIGING BV
Rotterdam, Netherlands
Minimax Fire Solutions International GmbH
Germany
Minimax GmbH, Fire Protection
Glinde, Germany
Survitec Group Ltd
Birkenhead, United Kingdom
Weitere aus Hersteller- und Marktplatzverzeichnissen:
Minimax Brandbeveiliging B.V. / Minimax Fire Solutions International / Marine Department · Netherlands
Alle Betriebe für Minimax ansehen →