Primo D4
Grindex Primo D4 — Drainage - Ultra-compact portable.
Inspector Detail
▸
Common issues
- Impeller clogs with debris typical of bilge/drainage duty, reducing flow
- Mechanical seal wears and allows water into the motor housing
- Power cable or plug is damaged from repeated dragging across deck or through hatches
- Float switch, where fitted, sticks, causing the pump to run dry or fail to start
- Strainer/inlet screen blocks with debris, causing loss of prime or cavitation
- Pump overheats and trips if run dry for an extended period
Inspection checklist
- Visually inspect the power cable and plug for cuts, abrasion or water ingress before each deployment
- Perform an insulation resistance test on the motor before use, especially after storage
- Check the mechanical seal oil chamber for water contamination
- Inspect the impeller and wear plate for damage or wear
- Clean and inspect the strainer/inlet screen
- Test float switch operation, start/stop levels, if fitted
- Check the lifting handle and discharge hose coupling for security
Service intervals
| Insulation resistance test | every 3-6 months, or before use if the pump has been in storage |
| Seal oil chamber check | per the manufacturer's running-hour interval - confirm in the pump manual |
| Impeller/wear plate inspection | annually, or sooner after use in heavy debris |
| Cable and plug inspection | before each deployment |
Critical spares
- Mechanical seal kit
- O-ring and gasket set
- Impeller
- Cable gland/entry kit
- Strainer/inlet screen
Safety
- Electrical shock risk from a damaged cable or seal failure - always insulation-test before use and never bypass earth-leakage protection
- Pump and cable weight creates a manual handling hazard during deployment/recovery
- Entanglement risk from the submerged rotating impeller if hands are near the inlet while running
- Use only with a correctly rated, earth-leakage-protected supply or generator
Class survey
As a portable emergency drainage pump it is normally checked as part of the vessel's fire/damage control equipment inventory rather than as a classed fixed item; verify it is on the approved emergency equipment list with a current functional test record, unless it is designated as a fixed emergency bilge pump, in which case it falls under the bilge system survey.
Components & Design
Component data being added…
Technical Data
🤖 Ask about this model
One free question — answered like a marine engineer. No account needed.
Common failures & inspection points
Visual inspection of impeller surface, hard-iron coating integrity, and strainer perforations. Check for pitting in hydraulic surfaces.
Run pressure drop test across seal cavity; measure leakage rate at discharge. Inspect seal chamber for contamination ingress.
Megohm meter (insulation resistance test) across motor windings to ground at 500-1000VDC. Document baseline and trending.
Visual inspect cable jacket for cracks, UV damage, moisture ingress. Measure conductor resistance and insulation resistance annually.
Temperature monitoring of bearing housing (should not exceed 65°C). Visual inspection of oil color/clarity in accessible bearing cavities post-operation.
Type-general inspection and maintenance points for this equipment category — not model-specific.