Hilfsdiesel (Generatorsatz) · Hilfsdiesel
MAN Generator (PrimeServ) 8-L16/24 GenSet — Mechanical, 8 cyl × 160mm bore, 1000 rpm, MGO/HFO, 880 kW.
Haben Sie das Herstellerdatenblatt zu diesem Modell? Schicken Sie es mit dem Anfrageformular — wir prüfen es und nennen die Quelle.
| A-Inspection (Minor) | 1,000 - 2,000 running hours (e.g., filter changes, valve clearance check, injector function check) |
|---|---|
| B-Inspection (Intermediate) | 4,000 - 6,000 running hours (e.g., injector overhaul/replacement, turbocharger inspection, fuel pump calibration check) |
| C-Inspection (Major) | 8,000 - 12,000 running hours (e.g., cylinder head overhaul, fuel pump overhaul, main bearing inspection, piston crown cleaning) |
| D-Inspection (Major Overhaul) | 24,000 - 36,000 running hours (e.g., piston/liner withdrawal, crankshaft inspection, complete engine overhaul) |
| Cylinder Liner (Wear Diameter) | Max. 160.8 mm (0.8 mm over nominal bore) |
|---|---|
| Cylinder Liner (Ovality/Taper) | Max. 0.6 mm |
| Piston Ring Groove (Axial Clearance) | Max. 0.25 - 0.30 mm (depending on ring position) |
| Crankshaft Main/Big End Bearings (Clearance) | Max. 0.25 - 0.30 mm (beyond new specification) |
| Exhaust Valve Seat Recession | Max. 1.5 - 2.0 mm from cylinder head surface |
| Turbocharger Rotor Shaft Play (Axial) | Max. 0.15 - 0.20 mm |
| Turbocharger Rotor Shaft Play (Radial) | Max. 0.30 - 0.40 mm |
Die Bereiche sind für diese Bauklasse typisch. Maßgeblich sind stets die Herstellerunterlagen zur jeweiligen Seriennummer.
Class surveyors will typically focus on verifying the engine's overall condition, maintenance history, and the functionality of critical safety and operational systems. Key checks include: - Maintenance Records: Review of Planned Maintenance System (PMS) records, logbooks, and service reports to confirm adherence to manufacturer's recommendations and class requirements. - Safety Devices: Functional testing of overspeed trip, low lube oil pressure shutdown, high cooling water temperature shutdown, and emergency stop systems. - Fuel System Integrity: Inspection for leaks, proper securing of high-pressure lines, and verification of fuel changeover procedures (if HFO/MGO). - Lubrication System: Review of lube oil analysis reports, purifier operation, and visual inspection for leaks. - Cooling System: Inspection of pumps, heat exchangers, and pipework for leaks, corrosion, and proper operation. - Exhaust System: Integrity of insulation, absence of leaks, and condition of spark arrestor (if fitted). - Generator & Coupling: Visual inspection of generator windings, bearing temperatures (if running), insulation resistance (if stopped), and condition of the flexible coupling. - Engine Performance: Review of recent engine parameters (EGTs, pressures, temperatures, lube oil consumption) for consistency and normal operation. - General Condition: Overall cleanliness, absence of excessive vibration, proper securing of components, and availability of critical spare parts onboard.
Geschätzte Lebensdauer: 24,000 - 36,000 hours (before major overhaul / D-Service)
Kostenlos — senden Sie uns Ihre Anfrage zu MAN Generator (PrimeServ)-Ausrüstung. Unser Team prüft sie und antwortet per E-Mail.
Weitere Modelle desselben Ausrüstungstyps, zuerst MAN Generator (PrimeServ).
Sagen Sie uns, was Sie für diesen MAN Generator (PrimeServ) 8-L16/24 GenSet benötigen — ein Ersatzteil, einen Serviceeinsatz, eine zweite Meinung. Sind Sie MAN Generator (PrimeServ)? Diese Herstellerseite beanspruchen.
Servicetechniker? Schreiben Sie den Tagesbericht für diesen 8-L16/24 GenSet in OceanSphere Work — Fotos, Stunden und Teile, als PDF für den Reeder. 14 Tage kostenlos testen →
Ja. Technische Daten, Dokumente und Servicehinweise zu diesem Modell sind ohne Konto lesbar. Ein Konto bringt gespeicherte Suchen und Anfragen dazu, es nimmt nichts weg.
Ja. Nennen Sie uns Hersteller, Modell und Bedarf — ein Mensch liest jede Anfrage und antwortet per E-Mail.
Schicken Sie uns das Typenschild oder den richtigen Wert. Wir prüfen ihn gegen das Herstellerdatenblatt oder den Klassifikationsdatensatz und aktualisieren die Seite.