Turbosprężarka · Turbosprężarki
MAN ES Turbocharging TCR 18 — TCR, 8000 kW max.
Masz kartę katalogową producenta dla tego modelu? Wyślij ją razem z formularzem zapytania — sprawdzimy ją i podamy źródło.
| External visual inspection | Daily/Weekly |
|---|---|
| Rotor cleaning (compressor/turbine side) | 2,000 - 4,000 running hours (depending on fuel quality and operating profile) |
| Bearing inspection/replacement | 4,000 - 8,000 running hours (depending on bearing type and condition monitoring) |
| Nozzle ring/turbine blade inspection | 4,000 - 8,000 running hours |
| Major overhaul (full disassembly, inspection, replacement of wear parts) | 12,000 - 24,000 running hours |
| Turbocharger oil filter replacement (if separate) | 500 - 1,000 running hours or as per engine oil change interval |
| Axial play (rotor shaft) | Service limit: 0.20 - 0.25 mm (New: 0.08 - 0.15 mm). Exceeding this indicates thrust bearing wear. |
|---|---|
| Radial play (rotor shaft) | Service limit: 0.35 - 0.40 mm (New: 0.15 - 0.25 mm). Exceeding this indicates journal bearing wear. |
| Bearing shell thickness | Minimum specified thickness by MAN ES. Any reduction below this requires replacement. |
| Compressor impeller blade tip clearance | Maximum specified clearance by MAN ES. Increased clearance reduces efficiency; rubbing indicates bearing/shaft issues. |
| Turbine blade erosion/cracks | Any visible cracks, significant material loss (beyond minor pitting), or deformation requires replacement. |
| Nozzle ring deformation/cracks | Any visible cracks, significant deformation, or blockage affecting gas flow requires replacement. |
Zakresy są typowe dla tej klasy konstrukcyjnej. Decydujące są zawsze dokumenty producenta dla danego numeru seryjnego.
Class surveyors typically verify maintenance records (running hours, cleaning, bearing replacements, overhaul dates) and logbook entries. An external visual inspection for oil/gas leaks, cracks, and general condition of the turbocharger and its insulation is standard. Operational checks may include monitoring boost pressure, exhaust gas temperatures, and listening for unusual noises/vibrations. For special surveys or if performance issues are reported, internal inspection of the compressor and turbine sides (e.g., by removing covers) and measurement of rotor axial/radial play may be requested to assess the condition of critical components.
Szacowana trwałość: 12,000 - 24,000 running hours before major overhaul (replacement of bearings, seals, and potentially rotor components). Overall casing and shaft lifetime can exceed 50,000 hours with proper maintenance and component renewal.
Bezpłatnie — wyślij zapytanie dotyczące sprzętu MAN ES Turbocharging. Nasz zespół je sprawdzi i odpowie e-mailem.
Inne modele tego samego typu sprzętu, najpierw MAN ES Turbocharging.
Powiedz nam, czego potrzebujesz do tego MAN ES Turbocharging TCR 18 — części, wizyty serwisowej, drugiej opinii. Czy jesteś MAN ES Turbocharging? Przejmij tę stronę marki.
Serwisant? Napisz raport dzienny dla tego TCR 18 w OceanSphere Work — zdjęcia, godziny i części, jako PDF dla armatora. Wypróbuj 14 dni za darmo →
Tak. Dane techniczne, dokumenty i uwagi serwisowe tego modelu są dostępne bez konta. Konto dodaje zapisane wyszukiwania i zapytania, niczego nie odbiera.
Tak. Podaj producenta, model i czego potrzebujesz — każde zapytanie czyta człowiek i odpowiada e-mailem.
Wyślij nam tabliczkę lub prawidłową wartość. Sprawdzimy ją w karcie danych producenta lub rejestrze towarzystwa klasyfikacyjnego i zaktualizujemy stronę.