Turbosprężarka · Turbosprężarki
MAN ES Turbocharging TCT 18 — TCT, 55000 kW max.
Masz kartę katalogową producenta dla tego modelu? Wyślij ją razem z formularzem zapytania — sprawdzimy ją i podamy źródło.
| Water washing (compressor/turbine) | Daily to weekly, depending on fuel quality and operating conditions |
|---|---|
| Dry cleaning (turbine) | Every 250-500 running hours, or as indicated by performance drop |
| Bearing inspection/replacement | 6,000 - 12,000 running hours (depending on bearing type and condition monitoring) |
| Major overhaul (rotor balancing, casing inspection) | 12,000 - 24,000 running hours or every 3-5 years |
| Oil filter replacement (if applicable) | Every 500-1000 running hours |
Typowe interwały dla tej klasy konstrukcji, nie dane producenta dla Twojego modelu. Wiążąca jest instrukcja producenta.
| Rotor axial clearance | Typically 0.15 - 0.40 mm (new), wear limit +0.10 to +0.20 mm over new value (refer to OEM manual for exact TCT 18 limits). |
|---|---|
| Rotor radial clearance (journal bearing) | Typically 0.10 - 0.25 mm (new), wear limit +0.05 to +0.10 mm over new value. |
| Turbine blade erosion/corrosion | Depth of erosion/corrosion not exceeding 10-15% of blade thickness, or as specified by OEM. |
| Nozzle ring passage area | Deviation from original design area not exceeding 5-10% due to erosion/fouling. |
| Casing cracks | Any visible crack in pressure-retaining parts is generally unacceptable and requires repair or replacement. |
Zakresy są typowe dla tej klasy konstrukcyjnej. Decydujące są zawsze dokumenty producenta dla danego numeru seryjnego.
Class surveyors typically verify the general condition of the turbocharger, absence of excessive vibration, leaks (exhaust gas, oil), and proper functioning of safety devices (e.g., overspeed trip, alarm systems). They will review maintenance records, especially for bearing replacements and major overhauls. They may request a performance check or witness a run-up/run-down test. The integrity of insulation, securing arrangements, and compliance with SOLAS requirements for hot surface protection are also checked. Any signs of casing cracks or severe fouling will be noted.
Szacowana trwałość: For major overhaul: 12,000 - 24,000 running hours. Total operational lifetime with proper maintenance and component replacement can exceed 100,000 hours.
Bezpłatnie — wyślij zapytanie dotyczące sprzętu MAN ES Turbocharging. Nasz zespół je sprawdzi i odpowie e-mailem.
Inne modele tego samego typu sprzętu, najpierw MAN ES Turbocharging.
Powiedz nam, czego potrzebujesz do tego MAN ES Turbocharging TCT 18 — części, wizyty serwisowej, drugiej opinii. Czy jesteś MAN ES Turbocharging? Przejmij tę stronę marki.
Serwisant? Napisz raport dzienny dla tego TCT 18 w OceanSphere Work — zdjęcia, godziny i części, jako PDF dla armatora. Wypróbuj 14 dni za darmo →
Tak. Dane techniczne, dokumenty i uwagi serwisowe tego modelu są dostępne bez konta. Konto dodaje zapisane wyszukiwania i zapytania, niczego nie odbiera.
Tak. Podaj producenta, model i czego potrzebujesz — każde zapytanie czyta człowiek i odpowiada e-mailem.
Wyślij nam tabliczkę lub prawidłową wartość. Sprawdzimy ją w karcie danych producenta lub rejestrze towarzystwa klasyfikacyjnego i zaktualizujemy stronę.