Aalborg Industries (Alfa Laval)

Mission OC

The Mission OC is a composite oil‑exhaust‑gas water‑tube boiler that delivers up to 120 t/h of steam at 9 or 18 bar(g) and can run on oil, exhaust gas, or both.

Aalborg Industries (Alfa Laval) Mission OC
5-12 t/h steam
Capacity
Oil + Exhaust Gas → Steam
Medium

Inspector Detail

Common issues

  • Soot fires in the exhaust gas section from unburned fuel deposits building up on tube surfaces
  • Fireside tube fouling reducing heat transfer and raising exhaust gas temperature
  • Refractory damage or spalling in the furnace
  • Burner flame instability or ignition failure
  • Waterside scaling when feed water treatment is inadequate
  • Safety valve set pressure drifting off its calibrated value over time
  • Economizer or tube leaks from thermal fatigue at rolled joints
  • Soot blower malfunction leading to progressive fireside fouling

Inspection checklist

  • Check feed water treatment chemical residuals (e.g. oxygen scavenger) against the test schedule
  • Check boiler water TDS/alkalinity against the test schedule
  • Inspect the exhaust gas side for soot build-up
  • Check burner flame condition and the ignition/purge sequence
  • Function-test safety valves and confirm lift pressure at the next opportunity
  • Check level gauge glasses and level alarms
  • Inspect furnace refractory condition
  • Check soot blower operation
  • Check for external leaks or corrosion on the boiler casing and mountings

Service intervals

Boiler water chemistry testing daily or per watch
Feed water treatment dosing check daily
Safety valve function test typically annually, with set pressure verified at survey - confirm against class requirements
Internal inspection (waterside and fireside) typically at annual survey when the boiler can be opened and gas-freed
Exhaust gas side external cleaning per the maker's recommendation or condition-based on soot build-up

Typical wear limits

Tube wall thickness (UT measured) renewal is commonly indicated once wall thickness falls to around 70-80% of the original design value - confirm the exact allowable minimum against class rules and the maker's data for this boiler

Ranges are typical for this design class. Always confirm against the manufacturer documentation for your serial number.

Critical spares

  • Burner nozzle/atomizer
  • Ignition electrode
  • Flame scanner
  • Safety valve repair/spare kit
  • Manhole and handhole door gasket set
  • Water level gauge glass set

Safety

  • Pressurized steam system - a leak can cause severe burns; approach suspected leaks with caution and isolate before investigating
  • Boiler explosion risk if safety valves are not maintained and tested - this is a life-safety item, not routine maintenance
  • Combustion space explosion risk on ignition failure - always allow the purge cycle to complete before firing
  • Hot surfaces on the casing and uptake
  • Entry into the boiler for internal inspection is confined-space work - requires gas-freeing, isolation and a permit

Class survey

Boilers are subject to periodic class survey - external examination more frequently, full internal examination at longer intervals, commonly linked to the annual/intermediate/special survey cycle; surveyors check safety valve testing and sealing, review water treatment records, and require a hydrostatic test after any significant repair

Estimated lifetime: Not normally expressed in running hours; with proper water treatment and periodic tube renewal, marine boilers of this type commonly remain in service 20-25+ years, though actual life is highly dependent on water treatment quality and operating regime

Components & Design

Component data being added…

Technical Data

medium Oil + Exhaust Gas → Steam
type Composite Combined
boiler type Alfa Laval Aalborg Ölgefeuerte Schiffsdampfkessel (Water Tube / D-Type)

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Tube body leakage due to corrosion, pitting, deposits (scale/sludge) or wear

Internal visual inspection of all steam/water tubes; perform pressure test if suspected; seal leaking tube with conical stop valve after steel wire brush cleaning of tube ends. Leaking tubes must be renewed.

Water level regulation: failure of differential pressure transmitter or feedwater control valve leads to flooding/drying out

Check DP transmitter unit (external reference/variable leg, 4–20 mA output); feedwater control valve functional test; sight glass for cracks, contamination; test alarm function in control unit

Safety valve failure or incorrect opening/closing pressures — overpressure or inadequate emergency steam relief

Test two safety valves under full-load steam: pressure build-up 7 min. max. +6% working pressure permissible (water tubes); pop-point of each valve max. ±3% from set pressure; class notation: perform opening + accumulation test under classifier supervision

Furnace refractory damage (cracks, spalling) or soot/corrosion → heat leaks, furnace instability, drum overheating

Inspect furnace walls and refractory lining visually (min. 2x/year); check for cracks, moisture, soot deposits. Check lower tube plate (insulation + form refractory). After 3–4 weeks operation: perform blow-down, inspect/clean boiler, remove sludge

Loss of pressure integrity due to corrosion, cracks, rivets or welds → leakage, operating loss, safety risk

Hydrostatic test: fill boiler with water 21–65 °C (water tubes max. 71 °C). Pressure: 1.5× MAWP (non-entry) or 1.25× MAWP (entry). Secure safety valves with clamps. Check all seal surfaces, rivets, welds for leaks. Class notation: every 2 years (up to 8 years), then annually

Internal corrosion (water side), scale deposits or fire side soot/flocking → tube wear, heat loss, contamination

Class survey: water side (steam drum, water drum, all tubes) check for corrosion/cracks/deposits; fire side (furnace, flue gas path) check for soot/flocking (min. 2x/year). Man holes (top/bottom) permit access. If necessary use ultrasonic/endoscope for deeper defects

Type-general inspection and maintenance points for this equipment category — not model-specific.

Service & Maintenance

Integrated composite design. EG section at sea, oil section in port or supplementary. Soot blow EG section regularly.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

Replacement Parts

Aalborg Industries (Alfa Laval): Keep burner nozzle set, photocell and gaskets onboard. Lead time: 3–8 weeks for tubes.
Equipment Model #1079 · ✓ still in production