Skip to content
OceanSphereENGINES
Library › Inspection & safety data › Low level lighting in corridors
Inspection & safety data

Low level lighting in corridors

System: 04 - Emergency Systems · 56 findings in total.

What the data shows

Findings for this component on all vessels averaged 8 per year in 2022–2024, about the same as the 9 per year in 2019–2021 (−11.5 %).

Only 25 findings for this component on foreign-flag vessels in 2019–2024: too few cases for a trend statement.

The latest year, 2025, only covers data up to 29 Nov 2025 and is not used in the trend.

Trend: average of 2022–2024 vs. 2019–2021; ±15 % counts as rising/falling; fewer than 30 cases: no statement.

Related deficiency codes

For components with a deficiency code, the yearly figures are on the code page.

Findings by year

US Coast Guard, inspections 2018–2025; “foreign flag” = findings on foreign-flag vessels.

Low level lighting in corridors20184201913202072021620221020236202472025*3
YearFindingswith detentionShareforeign flag
2018400.0 %1
20191300.0 %6
2020700.0 %5
2021600.0 %5
20221000.0 %7
2023600.0 %0
2024700.0 %2
2025*300.0 %0

* 2025 (hatched bar): data to 29 Nov 2025 (incomplete year; not used in the trends).

By vessel type

Vessel typeFindings
Passenger Ship38
Towing Vessel10
not specified3
Bulk Carrier2
Barge1
Miscellaneous Vessel1
Offshore1