Instrumentation Cable

medium 111 / 111 models (Inspector)

Instrumentation cable carries low-level analogue and digital signals -- 4-20mA loops, thermocouple and RTD readings, digital bus data -- between field sensors and control systems, and its screening and pair twisting matter more than its current rating.

Read more — Instrumentation Cable explained

What defines instrumentation cable

Instrumentation cable is built to carry low-energy analogue and digital signals rather than power. A 4-20mA loop from a pressure transmitter, a thermocouple or RTD lead to a temperature indicator, or a digital fieldbus link to a valve positioner all run on cable whose job is to preserve a weak, noise-sensitive signal over tens or hundreds of metres of cable tray that also carries three-phase power feeders. The distinguishing features are individually or overall screened pairs, tight twist lengths to cancel induced noise, and conductors sized for signal integrity rather than current-carrying capacity -- most instrumentation cores run 0.5 to 1.5 mm². Power cable and control cable share a hull and a cable route with instrumentation cable, but mixing the two in the same gland plate or the same unscreened tray defeats the purpose of the screening.

Instrumentation cable construction
Cross section of a twisted-pair instrumentation cable showing the conductor pair with insulation, the pair foil shield with drain wire, the overall braided screen, and the outer sheath.

Construction

Conductor and insulation

Stranded tinned or bare copper conductors, insulated with cross-linked polyethylene (XLPE) or ethylene propylene rubber (EPR) for the temperatures typical of an engine room. Multi-core types group two, three or four conductors per pair or triad.

Screening

Individually screened pairs (often aluminium-polyester tape with a drain wire) protect against crosstalk between loops in the same cable; an overall screen protects the whole cable against external electromagnetic interference from adjacent power runs. Both together are used where a loop feeds a critical alarm or a governor.

Sheath and armour

An outer sheath of low-smoke, halogen-free (LSHF) compound is standard for cable run through accommodation and machinery spaces. Where the cable is exposed to mechanical damage -- open deck runs, engine room floor plates -- a braid or wire armour is added under the sheath.

Selection and routing

  • Number and type of pairs (twisted pair vs. twisted triad) matched to the signal type -- analogue loop, RTD three-wire, digital bus.
  • Screen configuration matched to signal sensitivity and the length of run.
  • Sheath material rated LSHF for spaces with fire and toxicity restrictions.
  • Segregation distance from power cables in the same tray, and separate trays for duplicated safety systems.
  • Fire performance class where the route passes through a fire zone boundary.

Regulations and class

SOLAS Ch. II-2 sets the fire integrity requirements that drive cable selection and routing through fire zone boundaries, and class societies apply their own segregation rules on top of it: cabling for duplicated essential services -- main and standby fire pump, for instance -- should not run through the same trunk so that one fire or one mechanical damage cannot take out both. IACS unified requirements cover cable testing (fire-retardant, flame-retardant, low-smoke) and the type approval that class surveyors check against the maker's certificate at delivery and at renewal survey. Screening and earthing arrangements for instrumentation loops feeding safety systems are also reviewed as part of the electrical drawing approval, not just the cable spec sheet.

Typical faults

FaultCauseConsequence
Erratic 4-20mA readingScreen earthed at both ends creating a ground loop, or not earthed at allFalse alarms, drifting readouts, operator distrust of the instrument
Signal noise coupled from power cableInstrumentation and power cable run in the same unscreened tray without separationIntermittent faults that are hard to reproduce during troubleshooting
Insulation breakdownChafing where cable passes through a bulkhead gland without a grommet, or bilge water ingressLoop failure, sometimes a short that trips an unrelated circuit
Broken conductor inside intact sheathRepeated flexing at a cable entry with no strain reliefOpen-circuit signal that reads as a fixed, plausible-looking value -- the hardest fault to catch

What to look for in a supplier

  • Type approval certificate matching the class society of the vessel, not a generic industrial cable data sheet.
  • Fire test certification traceable to the actual reel supplied.
  • Consistent core colour coding and printed metre marking for installation and later fault-finding.
  • Stock depth in the specific pair counts and screen types used aboard, so a damaged run can be replaced with the identical construction rather than a near match.

Earth the screen at one end only -- usually at the control system end -- and leave it isolated at the field end; earthing both ends is the single most common cause of a ghost instrument fault that no amount of loop calibration will fix.

Inspector Mode Show All 111 / 111 with inspector value

15 manufacturers · 111 models

Draka/Prysmian

10
LFHÖF-I 2Px1.5mm2 300/500V unverified
Cross Section (mm²)
1.5
Voltage Class
300/500V
Cores
2
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation deterioration caused by heat, oil, ultraviolet exposure, moisture or age, resulting in low insulation resistance, earth faults or intermittent trips
  • Termination overheating caused by loose lugs, corrosion or poor crimping, resulting in discoloration, odor or localized temperature rise
  • Mechanical damage caused by chafing, crushing, excessive bend or unsupported routing, resulting in exposed armor, sheath damage or conductor failure
  • Water ingress caused by damaged glands, sheath or deck penetrations, resulting in corrosion, leakage current or communication faults
  • Screening, grounding or fire-seal deficiency caused by incorrect installation or maintenance, resulting in interference, poor fault protection or reduced fire integrity
Service: Inspect visible cable runs, supports, glands, terminations, penetrations and fire stops for damage, corrosion, overheating and unauthorized modifications. Maintain bend radius and support without imposing strain on equipment terminals. Check insulation resistance or continuity using procedures suitable for connected equipment and isolate sensitive electronics when required. Inspect cable glands and deck penetrations for water ingress and verify screens and armor are terminated according to the approved design. Replace damaged cable with an approved equivalent rather than patching critical insulation casually. Refer to the manufacturer documentation for the exact figure for conductor ratings, bend radius and test limits.
Spare Parts: Keep suitable lengths of approved cable for critical services together with glands, lugs, ferrules, heat-shrink, identification materials and certified fire-stop products appropriate to the installation. Communication and fire-resistant cable replacements must preserve required screening and approval. Verify voltage, conductor size and material before use.
Use Cases: Power distribution, motor feeders, control circuits, instrumentation, safety systems and communications throughout merchant ships and offshore installations.
LFHÖF-I 4Px1.5mm2 300/500V unverified
Cross Section (mm²)
1.5
Voltage Class
300/500V
Cores
4
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation deterioration caused by heat, oil, ultraviolet exposure, moisture or age, resulting in low insulation resistance, earth faults or intermittent trips
  • Termination overheating caused by loose lugs, corrosion or poor crimping, resulting in discoloration, odor or localized temperature rise
  • Mechanical damage caused by chafing, crushing, excessive bend or unsupported routing, resulting in exposed armor, sheath damage or conductor failure
  • Water ingress caused by damaged glands, sheath or deck penetrations, resulting in corrosion, leakage current or communication faults
  • Screening, grounding or fire-seal deficiency caused by incorrect installation or maintenance, resulting in interference, poor fault protection or reduced fire integrity
Service: Inspect visible cable runs, supports, glands, terminations, penetrations and fire stops for damage, corrosion, overheating and unauthorized modifications. Maintain bend radius and support without imposing strain on equipment terminals. Check insulation resistance or continuity using procedures suitable for connected equipment and isolate sensitive electronics when required. Inspect cable glands and deck penetrations for water ingress and verify screens and armor are terminated according to the approved design. Replace damaged cable with an approved equivalent rather than patching critical insulation casually. Refer to the manufacturer documentation for the exact figure for conductor ratings, bend radius and test limits.
Spare Parts: Keep suitable lengths of approved cable for critical services together with glands, lugs, ferrules, heat-shrink, identification materials and certified fire-stop products appropriate to the installation. Communication and fire-resistant cable replacements must preserve required screening and approval. Verify voltage, conductor size and material before use.
Use Cases: Power distribution, motor feeders, control circuits, instrumentation, safety systems and communications throughout merchant ships and offshore installations.
LFHÖF-I 6Px1.5mm2 300/500V unverified
Cross Section (mm²)
1.5
Voltage Class
300/500V
Cores
6
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation deterioration caused by heat, oil, ultraviolet exposure, moisture or age, resulting in low insulation resistance, earth faults or intermittent trips
  • Termination overheating caused by loose lugs, corrosion or poor crimping, resulting in discoloration, odor or localized temperature rise
  • Mechanical damage caused by chafing, crushing, excessive bend or unsupported routing, resulting in exposed armor, sheath damage or conductor failure
  • Water ingress caused by damaged glands, sheath or deck penetrations, resulting in corrosion, leakage current or communication faults
  • Screening, grounding or fire-seal deficiency caused by incorrect installation or maintenance, resulting in interference, poor fault protection or reduced fire integrity
Service: Inspect visible cable runs, supports, glands, terminations, penetrations and fire stops for damage, corrosion, overheating and unauthorized modifications. Maintain bend radius and support without imposing strain on equipment terminals. Check insulation resistance or continuity using procedures suitable for connected equipment and isolate sensitive electronics when required. Inspect cable glands and deck penetrations for water ingress and verify screens and armor are terminated according to the approved design. Replace damaged cable with an approved equivalent rather than patching critical insulation casually. Refer to the manufacturer documentation for the exact figure for conductor ratings, bend radius and test limits.
Spare Parts: Keep suitable lengths of approved cable for critical services together with glands, lugs, ferrules, heat-shrink, identification materials and certified fire-stop products appropriate to the installation. Communication and fire-resistant cable replacements must preserve required screening and approval. Verify voltage, conductor size and material before use.
Use Cases: Power distribution, motor feeders, control circuits, instrumentation, safety systems and communications throughout merchant ships and offshore installations.
LFHÖF-I 8Px1.5mm2 300/500V unverified
Cross Section (mm²)
1.5
Voltage Class
300/500V
Cores
8
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation deterioration caused by heat, oil, ultraviolet exposure, moisture or age, resulting in low insulation resistance, earth faults or intermittent trips
  • Termination overheating caused by loose lugs, corrosion or poor crimping, resulting in discoloration, odor or localized temperature rise
  • Mechanical damage caused by chafing, crushing, excessive bend or unsupported routing, resulting in exposed armor, sheath damage or conductor failure
  • Water ingress caused by damaged glands, sheath or deck penetrations, resulting in corrosion, leakage current or communication faults
  • Screening, grounding or fire-seal deficiency caused by incorrect installation or maintenance, resulting in interference, poor fault protection or reduced fire integrity
Service: Inspect visible cable runs, supports, glands, terminations, penetrations and fire stops for damage, corrosion, overheating and unauthorized modifications. Maintain bend radius and support without imposing strain on equipment terminals. Check insulation resistance or continuity using procedures suitable for connected equipment and isolate sensitive electronics when required. Inspect cable glands and deck penetrations for water ingress and verify screens and armor are terminated according to the approved design. Replace damaged cable with an approved equivalent rather than patching critical insulation casually. Refer to the manufacturer documentation for the exact figure for conductor ratings, bend radius and test limits.
Spare Parts: Keep suitable lengths of approved cable for critical services together with glands, lugs, ferrules, heat-shrink, identification materials and certified fire-stop products appropriate to the installation. Communication and fire-resistant cable replacements must preserve required screening and approval. Verify voltage, conductor size and material before use.
Use Cases: Power distribution, motor feeders, control circuits, instrumentation, safety systems and communications throughout merchant ships and offshore installations.
LFHÖF-I 12Px1.5mm2 300/500V unverified
Cross Section (mm²)
1.5
Voltage Class
300/500V
Cores
12
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation deterioration caused by heat, oil, ultraviolet exposure, moisture or age, resulting in low insulation resistance, earth faults or intermittent trips
  • Termination overheating caused by loose lugs, corrosion or poor crimping, resulting in discoloration, odor or localized temperature rise
  • Mechanical damage caused by chafing, crushing, excessive bend or unsupported routing, resulting in exposed armor, sheath damage or conductor failure
  • Water ingress caused by damaged glands, sheath or deck penetrations, resulting in corrosion, leakage current or communication faults
  • Screening, grounding or fire-seal deficiency caused by incorrect installation or maintenance, resulting in interference, poor fault protection or reduced fire integrity
Service: Inspect visible cable runs, supports, glands, terminations, penetrations and fire stops for damage, corrosion, overheating and unauthorized modifications. Maintain bend radius and support without imposing strain on equipment terminals. Check insulation resistance or continuity using procedures suitable for connected equipment and isolate sensitive electronics when required. Inspect cable glands and deck penetrations for water ingress and verify screens and armor are terminated according to the approved design. Replace damaged cable with an approved equivalent rather than patching critical insulation casually. Refer to the manufacturer documentation for the exact figure for conductor ratings, bend radius and test limits.
Spare Parts: Keep suitable lengths of approved cable for critical services together with glands, lugs, ferrules, heat-shrink, identification materials and certified fire-stop products appropriate to the installation. Communication and fire-resistant cable replacements must preserve required screening and approval. Verify voltage, conductor size and material before use.
Use Cases: Power distribution, motor feeders, control circuits, instrumentation, safety systems and communications throughout merchant ships and offshore installations.
LFHÖF-I 2Px2.5mm2 300/500V unverified
Cross Section (mm²)
2.5
Voltage Class
300/500V
Cores
2
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation deterioration caused by heat, oil, ultraviolet exposure, moisture or age, resulting in low insulation resistance, earth faults or intermittent trips
  • Termination overheating caused by loose lugs, corrosion or poor crimping, resulting in discoloration, odor or localized temperature rise
  • Mechanical damage caused by chafing, crushing, excessive bend or unsupported routing, resulting in exposed armor, sheath damage or conductor failure
  • Water ingress caused by damaged glands, sheath or deck penetrations, resulting in corrosion, leakage current or communication faults
  • Screening, grounding or fire-seal deficiency caused by incorrect installation or maintenance, resulting in interference, poor fault protection or reduced fire integrity
Service: Inspect visible cable runs, supports, glands, terminations, penetrations and fire stops for damage, corrosion, overheating and unauthorized modifications. Maintain bend radius and support without imposing strain on equipment terminals. Check insulation resistance or continuity using procedures suitable for connected equipment and isolate sensitive electronics when required. Inspect cable glands and deck penetrations for water ingress and verify screens and armor are terminated according to the approved design. Replace damaged cable with an approved equivalent rather than patching critical insulation casually. Refer to the manufacturer documentation for the exact figure for conductor ratings, bend radius and test limits.
Spare Parts: Keep suitable lengths of approved cable for critical services together with glands, lugs, ferrules, heat-shrink, identification materials and certified fire-stop products appropriate to the installation. Communication and fire-resistant cable replacements must preserve required screening and approval. Verify voltage, conductor size and material before use.
Use Cases: Power distribution, motor feeders, control circuits, instrumentation, safety systems and communications throughout merchant ships and offshore installations.
LFHÖF-I 4Px2.5mm2 300/500V unverified
Cross Section (mm²)
2.5
Voltage Class
300/500V
Cores
4
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation deterioration caused by heat, oil, ultraviolet exposure, moisture or age, resulting in low insulation resistance, earth faults or intermittent trips
  • Termination overheating caused by loose lugs, corrosion or poor crimping, resulting in discoloration, odor or localized temperature rise
  • Mechanical damage caused by chafing, crushing, excessive bend or unsupported routing, resulting in exposed armor, sheath damage or conductor failure
  • Water ingress caused by damaged glands, sheath or deck penetrations, resulting in corrosion, leakage current or communication faults
  • Screening, grounding or fire-seal deficiency caused by incorrect installation or maintenance, resulting in interference, poor fault protection or reduced fire integrity
Service: Inspect visible cable runs, supports, glands, terminations, penetrations and fire stops for damage, corrosion, overheating and unauthorized modifications. Maintain bend radius and support without imposing strain on equipment terminals. Check insulation resistance or continuity using procedures suitable for connected equipment and isolate sensitive electronics when required. Inspect cable glands and deck penetrations for water ingress and verify screens and armor are terminated according to the approved design. Replace damaged cable with an approved equivalent rather than patching critical insulation casually. Refer to the manufacturer documentation for the exact figure for conductor ratings, bend radius and test limits.
Spare Parts: Keep suitable lengths of approved cable for critical services together with glands, lugs, ferrules, heat-shrink, identification materials and certified fire-stop products appropriate to the installation. Communication and fire-resistant cable replacements must preserve required screening and approval. Verify voltage, conductor size and material before use.
Use Cases: Power distribution, motor feeders, control circuits, instrumentation, safety systems and communications throughout merchant ships and offshore installations.
LFHÖF-I 6Px2.5mm2 300/500V unverified
Cross Section (mm²)
2.5
Voltage Class
300/500V
Cores
6
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation deterioration caused by heat, oil, ultraviolet exposure, moisture or age, resulting in low insulation resistance, earth faults or intermittent trips
  • Termination overheating caused by loose lugs, corrosion or poor crimping, resulting in discoloration, odor or localized temperature rise
  • Mechanical damage caused by chafing, crushing, excessive bend or unsupported routing, resulting in exposed armor, sheath damage or conductor failure
  • Water ingress caused by damaged glands, sheath or deck penetrations, resulting in corrosion, leakage current or communication faults
  • Screening, grounding or fire-seal deficiency caused by incorrect installation or maintenance, resulting in interference, poor fault protection or reduced fire integrity
Service: Inspect visible cable runs, supports, glands, terminations, penetrations and fire stops for damage, corrosion, overheating and unauthorized modifications. Maintain bend radius and support without imposing strain on equipment terminals. Check insulation resistance or continuity using procedures suitable for connected equipment and isolate sensitive electronics when required. Inspect cable glands and deck penetrations for water ingress and verify screens and armor are terminated according to the approved design. Replace damaged cable with an approved equivalent rather than patching critical insulation casually. Refer to the manufacturer documentation for the exact figure for conductor ratings, bend radius and test limits.
Spare Parts: Keep suitable lengths of approved cable for critical services together with glands, lugs, ferrules, heat-shrink, identification materials and certified fire-stop products appropriate to the installation. Communication and fire-resistant cable replacements must preserve required screening and approval. Verify voltage, conductor size and material before use.
Use Cases: Power distribution, motor feeders, control circuits, instrumentation, safety systems and communications throughout merchant ships and offshore installations.
LFHÖF-I 8Px2.5mm2 300/500V unverified
Cross Section (mm²)
2.5
Voltage Class
300/500V
Cores
8
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation deterioration caused by heat, oil, ultraviolet exposure, moisture or age, resulting in low insulation resistance, earth faults or intermittent trips
  • Termination overheating caused by loose lugs, corrosion or poor crimping, resulting in discoloration, odor or localized temperature rise
  • Mechanical damage caused by chafing, crushing, excessive bend or unsupported routing, resulting in exposed armor, sheath damage or conductor failure
  • Water ingress caused by damaged glands, sheath or deck penetrations, resulting in corrosion, leakage current or communication faults
  • Screening, grounding or fire-seal deficiency caused by incorrect installation or maintenance, resulting in interference, poor fault protection or reduced fire integrity
Service: Inspect visible cable runs, supports, glands, terminations, penetrations and fire stops for damage, corrosion, overheating and unauthorized modifications. Maintain bend radius and support without imposing strain on equipment terminals. Check insulation resistance or continuity using procedures suitable for connected equipment and isolate sensitive electronics when required. Inspect cable glands and deck penetrations for water ingress and verify screens and armor are terminated according to the approved design. Replace damaged cable with an approved equivalent rather than patching critical insulation casually. Refer to the manufacturer documentation for the exact figure for conductor ratings, bend radius and test limits.
Spare Parts: Keep suitable lengths of approved cable for critical services together with glands, lugs, ferrules, heat-shrink, identification materials and certified fire-stop products appropriate to the installation. Communication and fire-resistant cable replacements must preserve required screening and approval. Verify voltage, conductor size and material before use.
Use Cases: Power distribution, motor feeders, control circuits, instrumentation, safety systems and communications throughout merchant ships and offshore installations.
LFHÖF-I 12Px2.5mm2 300/500V unverified
Cross Section (mm²)
2.5
Voltage Class
300/500V
Cores
12
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation deterioration caused by heat, oil, ultraviolet exposure, moisture or age, resulting in low insulation resistance, earth faults or intermittent trips
  • Termination overheating caused by loose lugs, corrosion or poor crimping, resulting in discoloration, odor or localized temperature rise
  • Mechanical damage caused by chafing, crushing, excessive bend or unsupported routing, resulting in exposed armor, sheath damage or conductor failure
  • Water ingress caused by damaged glands, sheath or deck penetrations, resulting in corrosion, leakage current or communication faults
  • Screening, grounding or fire-seal deficiency caused by incorrect installation or maintenance, resulting in interference, poor fault protection or reduced fire integrity
Service: Inspect visible cable runs, supports, glands, terminations, penetrations and fire stops for damage, corrosion, overheating and unauthorized modifications. Maintain bend radius and support without imposing strain on equipment terminals. Check insulation resistance or continuity using procedures suitable for connected equipment and isolate sensitive electronics when required. Inspect cable glands and deck penetrations for water ingress and verify screens and armor are terminated according to the approved design. Replace damaged cable with an approved equivalent rather than patching critical insulation casually. Refer to the manufacturer documentation for the exact figure for conductor ratings, bend radius and test limits.
Spare Parts: Keep suitable lengths of approved cable for critical services together with glands, lugs, ferrules, heat-shrink, identification materials and certified fire-stop products appropriate to the installation. Communication and fire-resistant cable replacements must preserve required screening and approval. Verify voltage, conductor size and material before use.
Use Cases: Power distribution, motor feeders, control circuits, instrumentation, safety systems and communications throughout merchant ships and offshore installations.

Eland Cables

10
MGCH-I 2Px1.5mm2 300/500V unverified
Cross Section (mm²)
1.5
Voltage Class
300/500V
Cores
2
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Mechanical damage, crushing or excessive bending damages insulation and causes earth faults, conductor failure or intermittent circuits
  • Loose or corroded terminations create resistance heating and cause voltage drop, discoloration or intermittent signals
  • Water ingress through damaged sheaths or glands reduces insulation integrity and causes earth-fault alarms or unreliable operation
  • Heat, oil or chemical exposure degrades insulation and causes cracking, swelling or loss of dielectric integrity
  • Poor screening, bonding or separation on signal cables introduces electrical noise and causes unstable instrumentation or communication data
Service: Inspect accessible cable runs, supports, penetrations, glands, terminations and signs of heat, oil or mechanical damage. Check insulation condition and termination integrity using an approved test method appropriate to the circuit. Maintain fire stopping, segregation and shielding arrangements at penetrations and terminations. Refer to the cable and connected-equipment documentation for the exact figure for test voltage, bend radius and termination requirements.
Spare Parts: Carry approved glands, lugs, ferrules, heat-shrink or jointing materials and representative replacement cable for critical circuits where vessel practice requires it.
Use Cases: Electrical power distribution, motor feeders, control, instrumentation, communication and safety-system wiring.
MGCH-I 4Px1.5mm2 300/500V unverified
Cross Section (mm²)
1.5
Voltage Class
300/500V
Cores
4
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Mechanical damage, crushing or excessive bending damages insulation and causes earth faults, conductor failure or intermittent circuits
  • Loose or corroded terminations create resistance heating and cause voltage drop, discoloration or intermittent signals
  • Water ingress through damaged sheaths or glands reduces insulation integrity and causes earth-fault alarms or unreliable operation
  • Heat, oil or chemical exposure degrades insulation and causes cracking, swelling or loss of dielectric integrity
  • Poor screening, bonding or separation on signal cables introduces electrical noise and causes unstable instrumentation or communication data
Service: Inspect accessible cable runs, supports, penetrations, glands, terminations and signs of heat, oil or mechanical damage. Check insulation condition and termination integrity using an approved test method appropriate to the circuit. Maintain fire stopping, segregation and shielding arrangements at penetrations and terminations. Refer to the cable and connected-equipment documentation for the exact figure for test voltage, bend radius and termination requirements.
Spare Parts: Carry approved glands, lugs, ferrules, heat-shrink or jointing materials and representative replacement cable for critical circuits where vessel practice requires it.
Use Cases: Electrical power distribution, motor feeders, control, instrumentation, communication and safety-system wiring.
MGCH-I 6Px1.5mm2 300/500V unverified
Cross Section (mm²)
1.5
Voltage Class
300/500V
Cores
6
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Mechanical damage, crushing or excessive bending damages insulation and causes earth faults, conductor failure or intermittent circuits
  • Loose or corroded terminations create resistance heating and cause voltage drop, discoloration or intermittent signals
  • Water ingress through damaged sheaths or glands reduces insulation integrity and causes earth-fault alarms or unreliable operation
  • Heat, oil or chemical exposure degrades insulation and causes cracking, swelling or loss of dielectric integrity
  • Poor screening, bonding or separation on signal cables introduces electrical noise and causes unstable instrumentation or communication data
Service: Inspect accessible cable runs, supports, penetrations, glands, terminations and signs of heat, oil or mechanical damage. Check insulation condition and termination integrity using an approved test method appropriate to the circuit. Maintain fire stopping, segregation and shielding arrangements at penetrations and terminations. Refer to the cable and connected-equipment documentation for the exact figure for test voltage, bend radius and termination requirements.
Spare Parts: Carry approved glands, lugs, ferrules, heat-shrink or jointing materials and representative replacement cable for critical circuits where vessel practice requires it.
Use Cases: Electrical power distribution, motor feeders, control, instrumentation, communication and safety-system wiring.
MGCH-I 8Px1.5mm2 300/500V unverified
Cross Section (mm²)
1.5
Voltage Class
300/500V
Cores
8
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Mechanical damage, crushing or excessive bending damages insulation and causes earth faults, conductor failure or intermittent circuits
  • Loose or corroded terminations create resistance heating and cause voltage drop, discoloration or intermittent signals
  • Water ingress through damaged sheaths or glands reduces insulation integrity and causes earth-fault alarms or unreliable operation
  • Heat, oil or chemical exposure degrades insulation and causes cracking, swelling or loss of dielectric integrity
  • Poor screening, bonding or separation on signal cables introduces electrical noise and causes unstable instrumentation or communication data
Service: Inspect accessible cable runs, supports, penetrations, glands, terminations and signs of heat, oil or mechanical damage. Check insulation condition and termination integrity using an approved test method appropriate to the circuit. Maintain fire stopping, segregation and shielding arrangements at penetrations and terminations. Refer to the cable and connected-equipment documentation for the exact figure for test voltage, bend radius and termination requirements.
Spare Parts: Carry approved glands, lugs, ferrules, heat-shrink or jointing materials and representative replacement cable for critical circuits where vessel practice requires it.
Use Cases: Electrical power distribution, motor feeders, control, instrumentation, communication and safety-system wiring.
MGCH-I 12Px1.5mm2 300/500V unverified
Cross Section (mm²)
1.5
Voltage Class
300/500V
Cores
12
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Mechanical damage, crushing or excessive bending damages insulation and causes earth faults, conductor failure or intermittent circuits
  • Loose or corroded terminations create resistance heating and cause voltage drop, discoloration or intermittent signals
  • Water ingress through damaged sheaths or glands reduces insulation integrity and causes earth-fault alarms or unreliable operation
  • Heat, oil or chemical exposure degrades insulation and causes cracking, swelling or loss of dielectric integrity
  • Poor screening, bonding or separation on signal cables introduces electrical noise and causes unstable instrumentation or communication data
Service: Inspect accessible cable runs, supports, penetrations, glands, terminations and signs of heat, oil or mechanical damage. Check insulation condition and termination integrity using an approved test method appropriate to the circuit. Maintain fire stopping, segregation and shielding arrangements at penetrations and terminations. Refer to the cable and connected-equipment documentation for the exact figure for test voltage, bend radius and termination requirements.
Spare Parts: Carry approved glands, lugs, ferrules, heat-shrink or jointing materials and representative replacement cable for critical circuits where vessel practice requires it.
Use Cases: Electrical power distribution, motor feeders, control, instrumentation, communication and safety-system wiring.
MGCH-I 2Px2.5mm2 300/500V unverified
Cross Section (mm²)
2.5
Voltage Class
300/500V
Cores
2
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Mechanical damage, crushing or excessive bending damages insulation and causes earth faults, conductor failure or intermittent circuits
  • Loose or corroded terminations create resistance heating and cause voltage drop, discoloration or intermittent signals
  • Water ingress through damaged sheaths or glands reduces insulation integrity and causes earth-fault alarms or unreliable operation
  • Heat, oil or chemical exposure degrades insulation and causes cracking, swelling or loss of dielectric integrity
  • Poor screening, bonding or separation on signal cables introduces electrical noise and causes unstable instrumentation or communication data
Service: Inspect accessible cable runs, supports, penetrations, glands, terminations and signs of heat, oil or mechanical damage. Check insulation condition and termination integrity using an approved test method appropriate to the circuit. Maintain fire stopping, segregation and shielding arrangements at penetrations and terminations. Refer to the cable and connected-equipment documentation for the exact figure for test voltage, bend radius and termination requirements.
Spare Parts: Carry approved glands, lugs, ferrules, heat-shrink or jointing materials and representative replacement cable for critical circuits where vessel practice requires it.
Use Cases: Electrical power distribution, motor feeders, control, instrumentation, communication and safety-system wiring.
MGCH-I 4Px2.5mm2 300/500V unverified
Cross Section (mm²)
2.5
Voltage Class
300/500V
Cores
4
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Mechanical damage, crushing or excessive bending damages insulation and causes earth faults, conductor failure or intermittent circuits
  • Loose or corroded terminations create resistance heating and cause voltage drop, discoloration or intermittent signals
  • Water ingress through damaged sheaths or glands reduces insulation integrity and causes earth-fault alarms or unreliable operation
  • Heat, oil or chemical exposure degrades insulation and causes cracking, swelling or loss of dielectric integrity
  • Poor screening, bonding or separation on signal cables introduces electrical noise and causes unstable instrumentation or communication data
Service: Inspect accessible cable runs, supports, penetrations, glands, terminations and signs of heat, oil or mechanical damage. Check insulation condition and termination integrity using an approved test method appropriate to the circuit. Maintain fire stopping, segregation and shielding arrangements at penetrations and terminations. Refer to the cable and connected-equipment documentation for the exact figure for test voltage, bend radius and termination requirements.
Spare Parts: Carry approved glands, lugs, ferrules, heat-shrink or jointing materials and representative replacement cable for critical circuits where vessel practice requires it.
Use Cases: Electrical power distribution, motor feeders, control, instrumentation, communication and safety-system wiring.
MGCH-I 6Px2.5mm2 300/500V unverified
Cross Section (mm²)
2.5
Voltage Class
300/500V
Cores
6
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Mechanical damage, crushing or excessive bending damages insulation and causes earth faults, conductor failure or intermittent circuits
  • Loose or corroded terminations create resistance heating and cause voltage drop, discoloration or intermittent signals
  • Water ingress through damaged sheaths or glands reduces insulation integrity and causes earth-fault alarms or unreliable operation
  • Heat, oil or chemical exposure degrades insulation and causes cracking, swelling or loss of dielectric integrity
  • Poor screening, bonding or separation on signal cables introduces electrical noise and causes unstable instrumentation or communication data
Service: Inspect accessible cable runs, supports, penetrations, glands, terminations and signs of heat, oil or mechanical damage. Check insulation condition and termination integrity using an approved test method appropriate to the circuit. Maintain fire stopping, segregation and shielding arrangements at penetrations and terminations. Refer to the cable and connected-equipment documentation for the exact figure for test voltage, bend radius and termination requirements.
Spare Parts: Carry approved glands, lugs, ferrules, heat-shrink or jointing materials and representative replacement cable for critical circuits where vessel practice requires it.
Use Cases: Electrical power distribution, motor feeders, control, instrumentation, communication and safety-system wiring.
MGCH-I 8Px2.5mm2 300/500V unverified
Cross Section (mm²)
2.5
Voltage Class
300/500V
Cores
8
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Mechanical damage, crushing or excessive bending damages insulation and causes earth faults, conductor failure or intermittent circuits
  • Loose or corroded terminations create resistance heating and cause voltage drop, discoloration or intermittent signals
  • Water ingress through damaged sheaths or glands reduces insulation integrity and causes earth-fault alarms or unreliable operation
  • Heat, oil or chemical exposure degrades insulation and causes cracking, swelling or loss of dielectric integrity
  • Poor screening, bonding or separation on signal cables introduces electrical noise and causes unstable instrumentation or communication data
Service: Inspect accessible cable runs, supports, penetrations, glands, terminations and signs of heat, oil or mechanical damage. Check insulation condition and termination integrity using an approved test method appropriate to the circuit. Maintain fire stopping, segregation and shielding arrangements at penetrations and terminations. Refer to the cable and connected-equipment documentation for the exact figure for test voltage, bend radius and termination requirements.
Spare Parts: Carry approved glands, lugs, ferrules, heat-shrink or jointing materials and representative replacement cable for critical circuits where vessel practice requires it.
Use Cases: Electrical power distribution, motor feeders, control, instrumentation, communication and safety-system wiring.
MGCH-I 12Px2.5mm2 300/500V unverified
Cross Section (mm²)
2.5
Voltage Class
300/500V
Cores
12
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Mechanical damage, crushing or excessive bending damages insulation and causes earth faults, conductor failure or intermittent circuits
  • Loose or corroded terminations create resistance heating and cause voltage drop, discoloration or intermittent signals
  • Water ingress through damaged sheaths or glands reduces insulation integrity and causes earth-fault alarms or unreliable operation
  • Heat, oil or chemical exposure degrades insulation and causes cracking, swelling or loss of dielectric integrity
  • Poor screening, bonding or separation on signal cables introduces electrical noise and causes unstable instrumentation or communication data
Service: Inspect accessible cable runs, supports, penetrations, glands, terminations and signs of heat, oil or mechanical damage. Check insulation condition and termination integrity using an approved test method appropriate to the circuit. Maintain fire stopping, segregation and shielding arrangements at penetrations and terminations. Refer to the cable and connected-equipment documentation for the exact figure for test voltage, bend radius and termination requirements.
Spare Parts: Carry approved glands, lugs, ferrules, heat-shrink or jointing materials and representative replacement cable for critical circuits where vessel practice requires it.
Use Cases: Electrical power distribution, motor feeders, control, instrumentation, communication and safety-system wiring.

Helkama Bica

10
LKIM 2Px1.5mm2 300/500V unverified
Cross Section (mm²)
1.5
Voltage Class
300/500V
Cores
2
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation deterioration from heat, oil, chemicals, UV exposure or ageing, typically indicated by low insulation resistance, earth-fault alarms or visible cracking
  • Mechanical damage from chafing, crushing or poor support, typically indicated by exposed armour or conductors, intermittent faults or short circuits
  • Water ingress through damaged glands or transits, typically indicated by corrosion, insulation alarms or intermittent operation
  • Loose or overheated terminations from poor tightening or excessive current, typically indicated by discoloration, hot spots, voltage drop or burnt insulation
  • Shielding, armour or bonding discontinuity from corrosion or incorrect termination, typically indicated by electrical noise, unreliable signals or failed protective bonding checks
Service: Inspect cable routes, supports, bending, glands, armour or screens, fire-stop transits and terminations; perform insulation, continuity or functional testing as appropriate and use manufacturer/class documentation for exact acceptance values.
Spare Parts: Keep approved cable glands, lugs, ferrules, heat-shrink, transit inserts or sealing modules and suitable lengths of critical cable types used on board.
Use Cases: Used in all vessel electrical, automation, propulsion, communication and safety systems, with the exact cable type selected for voltage, fire performance and signal duty. This entry applies specifically to the Instrumentation Cable variant identified as Helkama Bica LKIM 2Px1.5mm2 300/500V.
LKIM 4Px1.5mm2 300/500V unverified
Cross Section (mm²)
1.5
Voltage Class
300/500V
Cores
4
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation deterioration from heat, oil, chemicals, UV exposure or ageing, typically indicated by low insulation resistance, earth-fault alarms or visible cracking
  • Mechanical damage from chafing, crushing or poor support, typically indicated by exposed armour or conductors, intermittent faults or short circuits
  • Water ingress through damaged glands or transits, typically indicated by corrosion, insulation alarms or intermittent operation
  • Loose or overheated terminations from poor tightening or excessive current, typically indicated by discoloration, hot spots, voltage drop or burnt insulation
  • Shielding, armour or bonding discontinuity from corrosion or incorrect termination, typically indicated by electrical noise, unreliable signals or failed protective bonding checks
Service: Inspect cable routes, supports, bending, glands, armour or screens, fire-stop transits and terminations; perform insulation, continuity or functional testing as appropriate and use manufacturer/class documentation for exact acceptance values.
Spare Parts: Keep approved cable glands, lugs, ferrules, heat-shrink, transit inserts or sealing modules and suitable lengths of critical cable types used on board.
Use Cases: Used in all vessel electrical, automation, propulsion, communication and safety systems, with the exact cable type selected for voltage, fire performance and signal duty. This entry applies specifically to the Instrumentation Cable variant identified as Helkama Bica LKIM 4Px1.5mm2 300/500V.
LKIM 6Px1.5mm2 300/500V unverified
Cross Section (mm²)
1.5
Voltage Class
300/500V
Cores
6
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation deterioration from heat, oil, chemicals, UV exposure or ageing, typically indicated by low insulation resistance, earth-fault alarms or visible cracking
  • Mechanical damage from chafing, crushing or poor support, typically indicated by exposed armour or conductors, intermittent faults or short circuits
  • Water ingress through damaged glands or transits, typically indicated by corrosion, insulation alarms or intermittent operation
  • Loose or overheated terminations from poor tightening or excessive current, typically indicated by discoloration, hot spots, voltage drop or burnt insulation
  • Shielding, armour or bonding discontinuity from corrosion or incorrect termination, typically indicated by electrical noise, unreliable signals or failed protective bonding checks
Service: Inspect cable routes, supports, bending, glands, armour or screens, fire-stop transits and terminations; perform insulation, continuity or functional testing as appropriate and use manufacturer/class documentation for exact acceptance values.
Spare Parts: Keep approved cable glands, lugs, ferrules, heat-shrink, transit inserts or sealing modules and suitable lengths of critical cable types used on board.
Use Cases: Used in all vessel electrical, automation, propulsion, communication and safety systems, with the exact cable type selected for voltage, fire performance and signal duty. This entry applies specifically to the Instrumentation Cable variant identified as Helkama Bica LKIM 6Px1.5mm2 300/500V.
LKIM 8Px1.5mm2 300/500V unverified
Cross Section (mm²)
1.5
Voltage Class
300/500V
Cores
8
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation deterioration from heat, oil, chemicals, UV exposure or ageing, typically indicated by low insulation resistance, earth-fault alarms or visible cracking
  • Mechanical damage from chafing, crushing or poor support, typically indicated by exposed armour or conductors, intermittent faults or short circuits
  • Water ingress through damaged glands or transits, typically indicated by corrosion, insulation alarms or intermittent operation
  • Loose or overheated terminations from poor tightening or excessive current, typically indicated by discoloration, hot spots, voltage drop or burnt insulation
  • Shielding, armour or bonding discontinuity from corrosion or incorrect termination, typically indicated by electrical noise, unreliable signals or failed protective bonding checks
Service: Inspect cable routes, supports, bending, glands, armour or screens, fire-stop transits and terminations; perform insulation, continuity or functional testing as appropriate and use manufacturer/class documentation for exact acceptance values.
Spare Parts: Keep approved cable glands, lugs, ferrules, heat-shrink, transit inserts or sealing modules and suitable lengths of critical cable types used on board.
Use Cases: Used in all vessel electrical, automation, propulsion, communication and safety systems, with the exact cable type selected for voltage, fire performance and signal duty. This entry applies specifically to the Instrumentation Cable variant identified as Helkama Bica LKIM 8Px1.5mm2 300/500V.
LKIM 12Px1.5mm2 300/500V unverified
Cross Section (mm²)
1.5
Voltage Class
300/500V
Cores
12
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Mechanical damage, crushing or excessive bending damages insulation and causes earth faults, conductor failure or intermittent circuits
  • Loose or corroded terminations create resistance heating and cause voltage drop, discoloration or intermittent signals
  • Water ingress through damaged sheaths or glands reduces insulation integrity and causes earth-fault alarms or unreliable operation
  • Heat, oil or chemical exposure degrades insulation and causes cracking, swelling or loss of dielectric integrity
  • Poor screening, bonding or separation on signal cables introduces electrical noise and causes unstable instrumentation or communication data
Service: Inspect accessible cable runs, supports, penetrations, glands, terminations and signs of heat, oil or mechanical damage. Check insulation condition and termination integrity using an approved test method appropriate to the circuit. Maintain fire stopping, segregation and shielding arrangements at penetrations and terminations. Refer to the cable and connected-equipment documentation for the exact figure for test voltage, bend radius and termination requirements.
Spare Parts: Carry approved glands, lugs, ferrules, heat-shrink or jointing materials and representative replacement cable for critical circuits where vessel practice requires it.
Use Cases: Electrical power distribution, motor feeders, control, instrumentation, communication and safety-system wiring.
LKIM 2Px2.5mm2 300/500V unverified
Cross Section (mm²)
2.5
Voltage Class
300/500V
Cores
2
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation deterioration from heat, oil, chemicals, UV exposure or ageing, typically indicated by low insulation resistance, earth-fault alarms or visible cracking
  • Mechanical damage from chafing, crushing or poor support, typically indicated by exposed armour or conductors, intermittent faults or short circuits
  • Water ingress through damaged glands or transits, typically indicated by corrosion, insulation alarms or intermittent operation
  • Loose or overheated terminations from poor tightening or excessive current, typically indicated by discoloration, hot spots, voltage drop or burnt insulation
  • Shielding, armour or bonding discontinuity from corrosion or incorrect termination, typically indicated by electrical noise, unreliable signals or failed protective bonding checks
Service: Inspect cable routes, supports, bending, glands, armour or screens, fire-stop transits and terminations; perform insulation, continuity or functional testing as appropriate and use manufacturer/class documentation for exact acceptance values.
Spare Parts: Keep approved cable glands, lugs, ferrules, heat-shrink, transit inserts or sealing modules and suitable lengths of critical cable types used on board.
Use Cases: Used in all vessel electrical, automation, propulsion, communication and safety systems, with the exact cable type selected for voltage, fire performance and signal duty. This entry applies specifically to the Instrumentation Cable variant identified as Helkama Bica LKIM 2Px2.5mm2 300/500V.
LKIM 4Px2.5mm2 300/500V unverified
Cross Section (mm²)
2.5
Voltage Class
300/500V
Cores
4
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation deterioration from heat, oil, chemicals, UV exposure or ageing, typically indicated by low insulation resistance, earth-fault alarms or visible cracking
  • Mechanical damage from chafing, crushing or poor support, typically indicated by exposed armour or conductors, intermittent faults or short circuits
  • Water ingress through damaged glands or transits, typically indicated by corrosion, insulation alarms or intermittent operation
  • Loose or overheated terminations from poor tightening or excessive current, typically indicated by discoloration, hot spots, voltage drop or burnt insulation
  • Shielding, armour or bonding discontinuity from corrosion or incorrect termination, typically indicated by electrical noise, unreliable signals or failed protective bonding checks
Service: Inspect cable routes, supports, bending, glands, armour or screens, fire-stop transits and terminations; perform insulation, continuity or functional testing as appropriate and use manufacturer/class documentation for exact acceptance values.
Spare Parts: Keep approved cable glands, lugs, ferrules, heat-shrink, transit inserts or sealing modules and suitable lengths of critical cable types used on board.
Use Cases: Used in all vessel electrical, automation, propulsion, communication and safety systems, with the exact cable type selected for voltage, fire performance and signal duty. This entry applies specifically to the Instrumentation Cable variant identified as Helkama Bica LKIM 4Px2.5mm2 300/500V.
LKIM 6Px2.5mm2 300/500V unverified
Cross Section (mm²)
2.5
Voltage Class
300/500V
Cores
6
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation deterioration from heat, oil, chemicals, UV exposure or ageing, typically indicated by low insulation resistance, earth-fault alarms or visible cracking
  • Mechanical damage from chafing, crushing or poor support, typically indicated by exposed armour or conductors, intermittent faults or short circuits
  • Water ingress through damaged glands or transits, typically indicated by corrosion, insulation alarms or intermittent operation
  • Loose or overheated terminations from poor tightening or excessive current, typically indicated by discoloration, hot spots, voltage drop or burnt insulation
  • Shielding, armour or bonding discontinuity from corrosion or incorrect termination, typically indicated by electrical noise, unreliable signals or failed protective bonding checks
Service: Inspect cable routes, supports, bending, glands, armour or screens, fire-stop transits and terminations; perform insulation, continuity or functional testing as appropriate and use manufacturer/class documentation for exact acceptance values.
Spare Parts: Keep approved cable glands, lugs, ferrules, heat-shrink, transit inserts or sealing modules and suitable lengths of critical cable types used on board.
Use Cases: Used in all vessel electrical, automation, propulsion, communication and safety systems, with the exact cable type selected for voltage, fire performance and signal duty. This entry applies specifically to the Instrumentation Cable variant identified as Helkama Bica LKIM 6Px2.5mm2 300/500V.
LKIM 8Px2.5mm2 300/500V unverified
Cross Section (mm²)
2.5
Voltage Class
300/500V
Cores
8
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation deterioration from heat, oil, chemicals, UV exposure or ageing, typically indicated by low insulation resistance, earth-fault alarms or visible cracking
  • Mechanical damage from chafing, crushing or poor support, typically indicated by exposed armour or conductors, intermittent faults or short circuits
  • Water ingress through damaged glands or transits, typically indicated by corrosion, insulation alarms or intermittent operation
  • Loose or overheated terminations from poor tightening or excessive current, typically indicated by discoloration, hot spots, voltage drop or burnt insulation
  • Shielding, armour or bonding discontinuity from corrosion or incorrect termination, typically indicated by electrical noise, unreliable signals or failed protective bonding checks
Service: Inspect cable routes, supports, bending, glands, armour or screens, fire-stop transits and terminations; perform insulation, continuity or functional testing as appropriate and use manufacturer/class documentation for exact acceptance values.
Spare Parts: Keep approved cable glands, lugs, ferrules, heat-shrink, transit inserts or sealing modules and suitable lengths of critical cable types used on board.
Use Cases: Used in all vessel electrical, automation, propulsion, communication and safety systems, with the exact cable type selected for voltage, fire performance and signal duty. This entry applies specifically to the Instrumentation Cable variant identified as Helkama Bica LKIM 8Px2.5mm2 300/500V.
LKIM 12Px2.5mm2 300/500V unverified
Cross Section (mm²)
2.5
Voltage Class
300/500V
Cores
12
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Mechanical damage, crushing or excessive bending damages insulation and causes earth faults, conductor failure or intermittent circuits
  • Loose or corroded terminations create resistance heating and cause voltage drop, discoloration or intermittent signals
  • Water ingress through damaged sheaths or glands reduces insulation integrity and causes earth-fault alarms or unreliable operation
  • Heat, oil or chemical exposure degrades insulation and causes cracking, swelling or loss of dielectric integrity
  • Poor screening, bonding or separation on signal cables introduces electrical noise and causes unstable instrumentation or communication data
Service: Inspect accessible cable runs, supports, penetrations, glands, terminations and signs of heat, oil or mechanical damage. Check insulation condition and termination integrity using an approved test method appropriate to the circuit. Maintain fire stopping, segregation and shielding arrangements at penetrations and terminations. Refer to the cable and connected-equipment documentation for the exact figure for test voltage, bend radius and termination requirements.
Spare Parts: Carry approved glands, lugs, ferrules, heat-shrink or jointing materials and representative replacement cable for critical circuits where vessel practice requires it.
Use Cases: Electrical power distribution, motor feeders, control, instrumentation, communication and safety-system wiring.

LS Cable

10
DPYC-I 2Px1.5mm2 300/500V unverified
Cross Section (mm²)
1.5
Voltage Class
300/500V
Cores
2
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation deterioration from heat, oil, chemicals, UV exposure or ageing, typically indicated by low insulation resistance, earth-fault alarms or visible cracking
  • Mechanical damage from chafing, crushing or poor support, typically indicated by exposed armour or conductors, intermittent faults or short circuits
  • Water ingress through damaged glands or transits, typically indicated by corrosion, insulation alarms or intermittent operation
  • Loose or overheated terminations from poor tightening or excessive current, typically indicated by discoloration, hot spots, voltage drop or burnt insulation
  • Shielding, armour or bonding discontinuity from corrosion or incorrect termination, typically indicated by electrical noise, unreliable signals or failed protective bonding checks
Service: Inspect cable routes, supports, bending, glands, armour or screens, fire-stop transits and terminations; perform insulation, continuity or functional testing as appropriate and use manufacturer/class documentation for exact acceptance values.
Spare Parts: Keep approved cable glands, lugs, ferrules, heat-shrink, transit inserts or sealing modules and suitable lengths of critical cable types used on board.
Use Cases: Used in all vessel electrical, automation, propulsion, communication and safety systems, with the exact cable type selected for voltage, fire performance and signal duty. This entry applies specifically to the Instrumentation Cable variant identified as LS Cable DPYC-I 2Px1.5mm2 300/500V.
DPYC-I 4Px1.5mm2 300/500V unverified
Cross Section (mm²)
1.5
Voltage Class
300/500V
Cores
4
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation deterioration from heat, oil, chemicals, UV exposure or ageing, typically indicated by low insulation resistance, earth-fault alarms or visible cracking
  • Mechanical damage from chafing, crushing or poor support, typically indicated by exposed armour or conductors, intermittent faults or short circuits
  • Water ingress through damaged glands or transits, typically indicated by corrosion, insulation alarms or intermittent operation
  • Loose or overheated terminations from poor tightening or excessive current, typically indicated by discoloration, hot spots, voltage drop or burnt insulation
  • Shielding, armour or bonding discontinuity from corrosion or incorrect termination, typically indicated by electrical noise, unreliable signals or failed protective bonding checks
Service: Inspect cable routes, supports, bending, glands, armour or screens, fire-stop transits and terminations; perform insulation, continuity or functional testing as appropriate and use manufacturer/class documentation for exact acceptance values.
Spare Parts: Keep approved cable glands, lugs, ferrules, heat-shrink, transit inserts or sealing modules and suitable lengths of critical cable types used on board.
Use Cases: Used in all vessel electrical, automation, propulsion, communication and safety systems, with the exact cable type selected for voltage, fire performance and signal duty. This entry applies specifically to the Instrumentation Cable variant identified as LS Cable DPYC-I 4Px1.5mm2 300/500V.
DPYC-I 6Px1.5mm2 300/500V unverified
Cross Section (mm²)
1.5
Voltage Class
300/500V
Cores
6
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation deterioration from heat, oil, chemicals, UV exposure or ageing, typically indicated by low insulation resistance, earth-fault alarms or visible cracking
  • Mechanical damage from chafing, crushing or poor support, typically indicated by exposed armour or conductors, intermittent faults or short circuits
  • Water ingress through damaged glands or transits, typically indicated by corrosion, insulation alarms or intermittent operation
  • Loose or overheated terminations from poor tightening or excessive current, typically indicated by discoloration, hot spots, voltage drop or burnt insulation
  • Shielding, armour or bonding discontinuity from corrosion or incorrect termination, typically indicated by electrical noise, unreliable signals or failed protective bonding checks
Service: Inspect cable routes, supports, bending, glands, armour or screens, fire-stop transits and terminations; perform insulation, continuity or functional testing as appropriate and use manufacturer/class documentation for exact acceptance values.
Spare Parts: Keep approved cable glands, lugs, ferrules, heat-shrink, transit inserts or sealing modules and suitable lengths of critical cable types used on board.
Use Cases: Used in all vessel electrical, automation, propulsion, communication and safety systems, with the exact cable type selected for voltage, fire performance and signal duty. This entry applies specifically to the Instrumentation Cable variant identified as LS Cable DPYC-I 6Px1.5mm2 300/500V.
DPYC-I 8Px1.5mm2 300/500V unverified
Cross Section (mm²)
1.5
Voltage Class
300/500V
Cores
8
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation deterioration from heat, oil, chemicals, UV exposure or ageing, typically indicated by low insulation resistance, earth-fault alarms or visible cracking
  • Mechanical damage from chafing, crushing or poor support, typically indicated by exposed armour or conductors, intermittent faults or short circuits
  • Water ingress through damaged glands or transits, typically indicated by corrosion, insulation alarms or intermittent operation
  • Loose or overheated terminations from poor tightening or excessive current, typically indicated by discoloration, hot spots, voltage drop or burnt insulation
  • Shielding, armour or bonding discontinuity from corrosion or incorrect termination, typically indicated by electrical noise, unreliable signals or failed protective bonding checks
Service: Inspect cable routes, supports, bending, glands, armour or screens, fire-stop transits and terminations; perform insulation, continuity or functional testing as appropriate and use manufacturer/class documentation for exact acceptance values.
Spare Parts: Keep approved cable glands, lugs, ferrules, heat-shrink, transit inserts or sealing modules and suitable lengths of critical cable types used on board.
Use Cases: Used in all vessel electrical, automation, propulsion, communication and safety systems, with the exact cable type selected for voltage, fire performance and signal duty. This entry applies specifically to the Instrumentation Cable variant identified as LS Cable DPYC-I 8Px1.5mm2 300/500V.
DPYC-I 12Px1.5mm2 300/500V unverified
Cross Section (mm²)
1.5
Voltage Class
300/500V
Cores
12
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation deterioration from heat, oil, chemicals, UV exposure or ageing, typically indicated by low insulation resistance, earth-fault alarms or visible cracking
  • Mechanical damage from chafing, crushing or poor support, typically indicated by exposed armour or conductors, intermittent faults or short circuits
  • Water ingress through damaged glands or transits, typically indicated by corrosion, insulation alarms or intermittent operation
  • Loose or overheated terminations from poor tightening or excessive current, typically indicated by discoloration, hot spots, voltage drop or burnt insulation
  • Shielding, armour or bonding discontinuity from corrosion or incorrect termination, typically indicated by electrical noise, unreliable signals or failed protective bonding checks
Service: Inspect cable routes, supports, bending, glands, armour or screens, fire-stop transits and terminations; perform insulation, continuity or functional testing as appropriate and use manufacturer/class documentation for exact acceptance values.
Spare Parts: Keep approved cable glands, lugs, ferrules, heat-shrink, transit inserts or sealing modules and suitable lengths of critical cable types used on board.
Use Cases: Used in all vessel electrical, automation, propulsion, communication and safety systems, with the exact cable type selected for voltage, fire performance and signal duty. This entry applies specifically to the Instrumentation Cable variant identified as LS Cable DPYC-I 12Px1.5mm2 300/500V.
DPYC-I 2Px2.5mm2 300/500V unverified
Cross Section (mm²)
2.5
Voltage Class
300/500V
Cores
2
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation deterioration from heat, oil, chemicals, UV exposure or ageing, typically indicated by low insulation resistance, earth-fault alarms or visible cracking
  • Mechanical damage from chafing, crushing or poor support, typically indicated by exposed armour or conductors, intermittent faults or short circuits
  • Water ingress through damaged glands or transits, typically indicated by corrosion, insulation alarms or intermittent operation
  • Loose or overheated terminations from poor tightening or excessive current, typically indicated by discoloration, hot spots, voltage drop or burnt insulation
  • Shielding, armour or bonding discontinuity from corrosion or incorrect termination, typically indicated by electrical noise, unreliable signals or failed protective bonding checks
Service: Inspect cable routes, supports, bending, glands, armour or screens, fire-stop transits and terminations; perform insulation, continuity or functional testing as appropriate and use manufacturer/class documentation for exact acceptance values.
Spare Parts: Keep approved cable glands, lugs, ferrules, heat-shrink, transit inserts or sealing modules and suitable lengths of critical cable types used on board.
Use Cases: Used in all vessel electrical, automation, propulsion, communication and safety systems, with the exact cable type selected for voltage, fire performance and signal duty. This entry applies specifically to the Instrumentation Cable variant identified as LS Cable DPYC-I 2Px2.5mm2 300/500V.
DPYC-I 4Px2.5mm2 300/500V unverified
Cross Section (mm²)
2.5
Voltage Class
300/500V
Cores
4
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation deterioration from heat, oil, chemicals, UV exposure or ageing, typically indicated by low insulation resistance, earth-fault alarms or visible cracking
  • Mechanical damage from chafing, crushing or poor support, typically indicated by exposed armour or conductors, intermittent faults or short circuits
  • Water ingress through damaged glands or transits, typically indicated by corrosion, insulation alarms or intermittent operation
  • Loose or overheated terminations from poor tightening or excessive current, typically indicated by discoloration, hot spots, voltage drop or burnt insulation
  • Shielding, armour or bonding discontinuity from corrosion or incorrect termination, typically indicated by electrical noise, unreliable signals or failed protective bonding checks
Service: Inspect cable routes, supports, bending, glands, armour or screens, fire-stop transits and terminations; perform insulation, continuity or functional testing as appropriate and use manufacturer/class documentation for exact acceptance values.
Spare Parts: Keep approved cable glands, lugs, ferrules, heat-shrink, transit inserts or sealing modules and suitable lengths of critical cable types used on board.
Use Cases: Used in all vessel electrical, automation, propulsion, communication and safety systems, with the exact cable type selected for voltage, fire performance and signal duty. This entry applies specifically to the Instrumentation Cable variant identified as LS Cable DPYC-I 4Px2.5mm2 300/500V.
DPYC-I 6Px2.5mm2 300/500V unverified
Cross Section (mm²)
2.5
Voltage Class
300/500V
Cores
6
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation deterioration from heat, oil, chemicals, UV exposure or ageing, typically indicated by low insulation resistance, earth-fault alarms or visible cracking
  • Mechanical damage from chafing, crushing or poor support, typically indicated by exposed armour or conductors, intermittent faults or short circuits
  • Water ingress through damaged glands or transits, typically indicated by corrosion, insulation alarms or intermittent operation
  • Loose or overheated terminations from poor tightening or excessive current, typically indicated by discoloration, hot spots, voltage drop or burnt insulation
  • Shielding, armour or bonding discontinuity from corrosion or incorrect termination, typically indicated by electrical noise, unreliable signals or failed protective bonding checks
Service: Inspect cable routes, supports, bending, glands, armour or screens, fire-stop transits and terminations; perform insulation, continuity or functional testing as appropriate and use manufacturer/class documentation for exact acceptance values.
Spare Parts: Keep approved cable glands, lugs, ferrules, heat-shrink, transit inserts or sealing modules and suitable lengths of critical cable types used on board.
Use Cases: Used in all vessel electrical, automation, propulsion, communication and safety systems, with the exact cable type selected for voltage, fire performance and signal duty. This entry applies specifically to the Instrumentation Cable variant identified as LS Cable DPYC-I 6Px2.5mm2 300/500V.
DPYC-I 8Px2.5mm2 300/500V unverified
Cross Section (mm²)
2.5
Voltage Class
300/500V
Cores
8
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation deterioration from heat, oil, chemicals, UV exposure or ageing, typically indicated by low insulation resistance, earth-fault alarms or visible cracking
  • Mechanical damage from chafing, crushing or poor support, typically indicated by exposed armour or conductors, intermittent faults or short circuits
  • Water ingress through damaged glands or transits, typically indicated by corrosion, insulation alarms or intermittent operation
  • Loose or overheated terminations from poor tightening or excessive current, typically indicated by discoloration, hot spots, voltage drop or burnt insulation
  • Shielding, armour or bonding discontinuity from corrosion or incorrect termination, typically indicated by electrical noise, unreliable signals or failed protective bonding checks
Service: Inspect cable routes, supports, bending, glands, armour or screens, fire-stop transits and terminations; perform insulation, continuity or functional testing as appropriate and use manufacturer/class documentation for exact acceptance values.
Spare Parts: Keep approved cable glands, lugs, ferrules, heat-shrink, transit inserts or sealing modules and suitable lengths of critical cable types used on board.
Use Cases: Used in all vessel electrical, automation, propulsion, communication and safety systems, with the exact cable type selected for voltage, fire performance and signal duty. This entry applies specifically to the Instrumentation Cable variant identified as LS Cable DPYC-I 8Px2.5mm2 300/500V.
DPYC-I 12Px2.5mm2 300/500V unverified
Cross Section (mm²)
2.5
Voltage Class
300/500V
Cores
12
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation deterioration from heat, oil, chemicals, UV exposure or ageing, typically indicated by low insulation resistance, earth-fault alarms or visible cracking
  • Mechanical damage from chafing, crushing or poor support, typically indicated by exposed armour or conductors, intermittent faults or short circuits
  • Water ingress through damaged glands or transits, typically indicated by corrosion, insulation alarms or intermittent operation
  • Loose or overheated terminations from poor tightening or excessive current, typically indicated by discoloration, hot spots, voltage drop or burnt insulation
  • Shielding, armour or bonding discontinuity from corrosion or incorrect termination, typically indicated by electrical noise, unreliable signals or failed protective bonding checks
Service: Inspect cable routes, supports, bending, glands, armour or screens, fire-stop transits and terminations; perform insulation, continuity or functional testing as appropriate and use manufacturer/class documentation for exact acceptance values.
Spare Parts: Keep approved cable glands, lugs, ferrules, heat-shrink, transit inserts or sealing modules and suitable lengths of critical cable types used on board.
Use Cases: Used in all vessel electrical, automation, propulsion, communication and safety systems, with the exact cable type selected for voltage, fire performance and signal duty. This entry applies specifically to the Instrumentation Cable variant identified as LS Cable DPYC-I 12Px2.5mm2 300/500V.

Nexans Marine

10
RFOU-I 2Px1.5mm2 300/500V unverified
Cross Section (mm²)
1.5
Voltage Class
300/500V
Cores
2
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Mechanical damage, crushing or excessive bending damages insulation and causes earth faults, conductor failure or intermittent circuits
  • Loose or corroded terminations create resistance heating and cause voltage drop, discoloration or intermittent signals
  • Water ingress through damaged sheaths or glands reduces insulation integrity and causes earth-fault alarms or unreliable operation
  • Heat, oil or chemical exposure degrades insulation and causes cracking, swelling or loss of dielectric integrity
  • Poor screening, bonding or separation on signal cables introduces electrical noise and causes unstable instrumentation or communication data
Service: Inspect accessible cable runs, supports, penetrations, glands, terminations and signs of heat, oil or mechanical damage. Check insulation condition and termination integrity using an approved test method appropriate to the circuit. Maintain fire stopping, segregation and shielding arrangements at penetrations and terminations. Refer to the cable and connected-equipment documentation for the exact figure for test voltage, bend radius and termination requirements.
Spare Parts: Carry approved glands, lugs, ferrules, heat-shrink or jointing materials and representative replacement cable for critical circuits where vessel practice requires it.
Use Cases: Electrical power distribution, motor feeders, control, instrumentation, communication and safety-system wiring.
RFOU-I 4Px1.5mm2 300/500V unverified
Cross Section (mm²)
1.5
Voltage Class
300/500V
Cores
4
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Mechanical damage, crushing or excessive bending damages insulation and causes earth faults, conductor failure or intermittent circuits
  • Loose or corroded terminations create resistance heating and cause voltage drop, discoloration or intermittent signals
  • Water ingress through damaged sheaths or glands reduces insulation integrity and causes earth-fault alarms or unreliable operation
  • Heat, oil or chemical exposure degrades insulation and causes cracking, swelling or loss of dielectric integrity
  • Poor screening, bonding or separation on signal cables introduces electrical noise and causes unstable instrumentation or communication data
Service: Inspect accessible cable runs, supports, penetrations, glands, terminations and signs of heat, oil or mechanical damage. Check insulation condition and termination integrity using an approved test method appropriate to the circuit. Maintain fire stopping, segregation and shielding arrangements at penetrations and terminations. Refer to the cable and connected-equipment documentation for the exact figure for test voltage, bend radius and termination requirements.
Spare Parts: Carry approved glands, lugs, ferrules, heat-shrink or jointing materials and representative replacement cable for critical circuits where vessel practice requires it.
Use Cases: Electrical power distribution, motor feeders, control, instrumentation, communication and safety-system wiring.
RFOU-I 6Px1.5mm2 300/500V unverified
Cross Section (mm²)
1.5
Voltage Class
300/500V
Cores
6
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Mechanical damage, crushing or excessive bending damages insulation and causes earth faults, conductor failure or intermittent circuits
  • Loose or corroded terminations create resistance heating and cause voltage drop, discoloration or intermittent signals
  • Water ingress through damaged sheaths or glands reduces insulation integrity and causes earth-fault alarms or unreliable operation
  • Heat, oil or chemical exposure degrades insulation and causes cracking, swelling or loss of dielectric integrity
  • Poor screening, bonding or separation on signal cables introduces electrical noise and causes unstable instrumentation or communication data
Service: Inspect accessible cable runs, supports, penetrations, glands, terminations and signs of heat, oil or mechanical damage. Check insulation condition and termination integrity using an approved test method appropriate to the circuit. Maintain fire stopping, segregation and shielding arrangements at penetrations and terminations. Refer to the cable and connected-equipment documentation for the exact figure for test voltage, bend radius and termination requirements.
Spare Parts: Carry approved glands, lugs, ferrules, heat-shrink or jointing materials and representative replacement cable for critical circuits where vessel practice requires it.
Use Cases: Electrical power distribution, motor feeders, control, instrumentation, communication and safety-system wiring.
RFOU-I 8Px1.5mm2 300/500V unverified
Cross Section (mm²)
1.5
Voltage Class
300/500V
Cores
8
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Mechanical damage, crushing or excessive bending damages insulation and causes earth faults, conductor failure or intermittent circuits
  • Loose or corroded terminations create resistance heating and cause voltage drop, discoloration or intermittent signals
  • Water ingress through damaged sheaths or glands reduces insulation integrity and causes earth-fault alarms or unreliable operation
  • Heat, oil or chemical exposure degrades insulation and causes cracking, swelling or loss of dielectric integrity
  • Poor screening, bonding or separation on signal cables introduces electrical noise and causes unstable instrumentation or communication data
Service: Inspect accessible cable runs, supports, penetrations, glands, terminations and signs of heat, oil or mechanical damage. Check insulation condition and termination integrity using an approved test method appropriate to the circuit. Maintain fire stopping, segregation and shielding arrangements at penetrations and terminations. Refer to the cable and connected-equipment documentation for the exact figure for test voltage, bend radius and termination requirements.
Spare Parts: Carry approved glands, lugs, ferrules, heat-shrink or jointing materials and representative replacement cable for critical circuits where vessel practice requires it.
Use Cases: Electrical power distribution, motor feeders, control, instrumentation, communication and safety-system wiring.
RFOU-I 12Px1.5mm2 300/500V unverified
Cross Section (mm²)
1.5
Voltage Class
300/500V
Cores
12
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation deterioration caused by heat, oil, ultraviolet exposure, moisture or age, resulting in low insulation resistance, earth faults or intermittent trips
  • Termination overheating caused by loose lugs, corrosion or poor crimping, resulting in discoloration, odor or localized temperature rise
  • Mechanical damage caused by chafing, crushing, excessive bend or unsupported routing, resulting in exposed armor, sheath damage or conductor failure
  • Water ingress caused by damaged glands, sheath or deck penetrations, resulting in corrosion, leakage current or communication faults
  • Screening, grounding or fire-seal deficiency caused by incorrect installation or maintenance, resulting in interference, poor fault protection or reduced fire integrity
Service: Inspect visible cable runs, supports, glands, terminations, penetrations and fire stops for damage, corrosion, overheating and unauthorized modifications. Maintain bend radius and support without imposing strain on equipment terminals. Check insulation resistance or continuity using procedures suitable for connected equipment and isolate sensitive electronics when required. Inspect cable glands and deck penetrations for water ingress and verify screens and armor are terminated according to the approved design. Replace damaged cable with an approved equivalent rather than patching critical insulation casually. Refer to the manufacturer documentation for the exact figure for conductor ratings, bend radius and test limits.
Spare Parts: Keep suitable lengths of approved cable for critical services together with glands, lugs, ferrules, heat-shrink, identification materials and certified fire-stop products appropriate to the installation. Communication and fire-resistant cable replacements must preserve required screening and approval. Verify voltage, conductor size and material before use.
Use Cases: Power distribution, motor feeders, control circuits, instrumentation, safety systems and communications throughout merchant ships and offshore installations.
RFOU-I 2Px2.5mm2 300/500V unverified
Cross Section (mm²)
2.5
Voltage Class
300/500V
Cores
2
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Mechanical damage, crushing or excessive bending damages insulation and causes earth faults, conductor failure or intermittent circuits
  • Loose or corroded terminations create resistance heating and cause voltage drop, discoloration or intermittent signals
  • Water ingress through damaged sheaths or glands reduces insulation integrity and causes earth-fault alarms or unreliable operation
  • Heat, oil or chemical exposure degrades insulation and causes cracking, swelling or loss of dielectric integrity
  • Poor screening, bonding or separation on signal cables introduces electrical noise and causes unstable instrumentation or communication data
Service: Inspect accessible cable runs, supports, penetrations, glands, terminations and signs of heat, oil or mechanical damage. Check insulation condition and termination integrity using an approved test method appropriate to the circuit. Maintain fire stopping, segregation and shielding arrangements at penetrations and terminations. Refer to the cable and connected-equipment documentation for the exact figure for test voltage, bend radius and termination requirements.
Spare Parts: Carry approved glands, lugs, ferrules, heat-shrink or jointing materials and representative replacement cable for critical circuits where vessel practice requires it.
Use Cases: Electrical power distribution, motor feeders, control, instrumentation, communication and safety-system wiring.
RFOU-I 4Px2.5mm2 300/500V unverified
Cross Section (mm²)
2.5
Voltage Class
300/500V
Cores
4
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Mechanical damage, crushing or excessive bending damages insulation and causes earth faults, conductor failure or intermittent circuits
  • Loose or corroded terminations create resistance heating and cause voltage drop, discoloration or intermittent signals
  • Water ingress through damaged sheaths or glands reduces insulation integrity and causes earth-fault alarms or unreliable operation
  • Heat, oil or chemical exposure degrades insulation and causes cracking, swelling or loss of dielectric integrity
  • Poor screening, bonding or separation on signal cables introduces electrical noise and causes unstable instrumentation or communication data
Service: Inspect accessible cable runs, supports, penetrations, glands, terminations and signs of heat, oil or mechanical damage. Check insulation condition and termination integrity using an approved test method appropriate to the circuit. Maintain fire stopping, segregation and shielding arrangements at penetrations and terminations. Refer to the cable and connected-equipment documentation for the exact figure for test voltage, bend radius and termination requirements.
Spare Parts: Carry approved glands, lugs, ferrules, heat-shrink or jointing materials and representative replacement cable for critical circuits where vessel practice requires it.
Use Cases: Electrical power distribution, motor feeders, control, instrumentation, communication and safety-system wiring.
RFOU-I 6Px2.5mm2 300/500V unverified
Cross Section (mm²)
2.5
Voltage Class
300/500V
Cores
6
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Mechanical damage, crushing or excessive bending damages insulation and causes earth faults, conductor failure or intermittent circuits
  • Loose or corroded terminations create resistance heating and cause voltage drop, discoloration or intermittent signals
  • Water ingress through damaged sheaths or glands reduces insulation integrity and causes earth-fault alarms or unreliable operation
  • Heat, oil or chemical exposure degrades insulation and causes cracking, swelling or loss of dielectric integrity
  • Poor screening, bonding or separation on signal cables introduces electrical noise and causes unstable instrumentation or communication data
Service: Inspect accessible cable runs, supports, penetrations, glands, terminations and signs of heat, oil or mechanical damage. Check insulation condition and termination integrity using an approved test method appropriate to the circuit. Maintain fire stopping, segregation and shielding arrangements at penetrations and terminations. Refer to the cable and connected-equipment documentation for the exact figure for test voltage, bend radius and termination requirements.
Spare Parts: Carry approved glands, lugs, ferrules, heat-shrink or jointing materials and representative replacement cable for critical circuits where vessel practice requires it.
Use Cases: Electrical power distribution, motor feeders, control, instrumentation, communication and safety-system wiring.
RFOU-I 8Px2.5mm2 300/500V unverified
Cross Section (mm²)
2.5
Voltage Class
300/500V
Cores
8
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Mechanical damage, crushing or excessive bending damages insulation and causes earth faults, conductor failure or intermittent circuits
  • Loose or corroded terminations create resistance heating and cause voltage drop, discoloration or intermittent signals
  • Water ingress through damaged sheaths or glands reduces insulation integrity and causes earth-fault alarms or unreliable operation
  • Heat, oil or chemical exposure degrades insulation and causes cracking, swelling or loss of dielectric integrity
  • Poor screening, bonding or separation on signal cables introduces electrical noise and causes unstable instrumentation or communication data
Service: Inspect accessible cable runs, supports, penetrations, glands, terminations and signs of heat, oil or mechanical damage. Check insulation condition and termination integrity using an approved test method appropriate to the circuit. Maintain fire stopping, segregation and shielding arrangements at penetrations and terminations. Refer to the cable and connected-equipment documentation for the exact figure for test voltage, bend radius and termination requirements.
Spare Parts: Carry approved glands, lugs, ferrules, heat-shrink or jointing materials and representative replacement cable for critical circuits where vessel practice requires it.
Use Cases: Electrical power distribution, motor feeders, control, instrumentation, communication and safety-system wiring.
RFOU-I 12Px2.5mm2 300/500V unverified
Cross Section (mm²)
2.5
Voltage Class
300/500V
Cores
12
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation deterioration caused by heat, oil, ultraviolet exposure, moisture or age, resulting in low insulation resistance, earth faults or intermittent trips
  • Termination overheating caused by loose lugs, corrosion or poor crimping, resulting in discoloration, odor or localized temperature rise
  • Mechanical damage caused by chafing, crushing, excessive bend or unsupported routing, resulting in exposed armor, sheath damage or conductor failure
  • Water ingress caused by damaged glands, sheath or deck penetrations, resulting in corrosion, leakage current or communication faults
  • Screening, grounding or fire-seal deficiency caused by incorrect installation or maintenance, resulting in interference, poor fault protection or reduced fire integrity
Service: Inspect visible cable runs, supports, glands, terminations, penetrations and fire stops for damage, corrosion, overheating and unauthorized modifications. Maintain bend radius and support without imposing strain on equipment terminals. Check insulation resistance or continuity using procedures suitable for connected equipment and isolate sensitive electronics when required. Inspect cable glands and deck penetrations for water ingress and verify screens and armor are terminated according to the approved design. Replace damaged cable with an approved equivalent rather than patching critical insulation casually. Refer to the manufacturer documentation for the exact figure for conductor ratings, bend radius and test limits.
Spare Parts: Keep suitable lengths of approved cable for critical services together with glands, lugs, ferrules, heat-shrink, identification materials and certified fire-stop products appropriate to the installation. Communication and fire-resistant cable replacements must preserve required screening and approval. Verify voltage, conductor size and material before use.
Use Cases: Power distribution, motor feeders, control circuits, instrumentation, safety systems and communications throughout merchant ships and offshore installations.

NKT Marine

10
N-CLASSIC-I 2Px1.5mm2 300/500V unverified
Cross Section (mm²)
1.5
Voltage Class
300/500V
Cores
2
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation deterioration caused by heat, oil, ultraviolet exposure, moisture or age, resulting in low insulation resistance, earth faults or intermittent trips
  • Termination overheating caused by loose lugs, corrosion or poor crimping, resulting in discoloration, odor or localized temperature rise
  • Mechanical damage caused by chafing, crushing, excessive bend or unsupported routing, resulting in exposed armor, sheath damage or conductor failure
  • Water ingress caused by damaged glands, sheath or deck penetrations, resulting in corrosion, leakage current or communication faults
  • Screening, grounding or fire-seal deficiency caused by incorrect installation or maintenance, resulting in interference, poor fault protection or reduced fire integrity
Service: Inspect visible cable runs, supports, glands, terminations, penetrations and fire stops for damage, corrosion, overheating and unauthorized modifications. Maintain bend radius and support without imposing strain on equipment terminals. Check insulation resistance or continuity using procedures suitable for connected equipment and isolate sensitive electronics when required. Inspect cable glands and deck penetrations for water ingress and verify screens and armor are terminated according to the approved design. Replace damaged cable with an approved equivalent rather than patching critical insulation casually. Refer to the manufacturer documentation for the exact figure for conductor ratings, bend radius and test limits.
Spare Parts: Keep suitable lengths of approved cable for critical services together with glands, lugs, ferrules, heat-shrink, identification materials and certified fire-stop products appropriate to the installation. Communication and fire-resistant cable replacements must preserve required screening and approval. Verify voltage, conductor size and material before use.
Use Cases: Power distribution, motor feeders, control circuits, instrumentation, safety systems and communications throughout merchant ships and offshore installations.
N-CLASSIC-I 4Px1.5mm2 300/500V unverified
Cross Section (mm²)
1.5
Voltage Class
300/500V
Cores
4
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation deterioration caused by heat, oil, ultraviolet exposure, moisture or age, resulting in low insulation resistance, earth faults or intermittent trips
  • Termination overheating caused by loose lugs, corrosion or poor crimping, resulting in discoloration, odor or localized temperature rise
  • Mechanical damage caused by chafing, crushing, excessive bend or unsupported routing, resulting in exposed armor, sheath damage or conductor failure
  • Water ingress caused by damaged glands, sheath or deck penetrations, resulting in corrosion, leakage current or communication faults
  • Screening, grounding or fire-seal deficiency caused by incorrect installation or maintenance, resulting in interference, poor fault protection or reduced fire integrity
Service: Inspect visible cable runs, supports, glands, terminations, penetrations and fire stops for damage, corrosion, overheating and unauthorized modifications. Maintain bend radius and support without imposing strain on equipment terminals. Check insulation resistance or continuity using procedures suitable for connected equipment and isolate sensitive electronics when required. Inspect cable glands and deck penetrations for water ingress and verify screens and armor are terminated according to the approved design. Replace damaged cable with an approved equivalent rather than patching critical insulation casually. Refer to the manufacturer documentation for the exact figure for conductor ratings, bend radius and test limits.
Spare Parts: Keep suitable lengths of approved cable for critical services together with glands, lugs, ferrules, heat-shrink, identification materials and certified fire-stop products appropriate to the installation. Communication and fire-resistant cable replacements must preserve required screening and approval. Verify voltage, conductor size and material before use.
Use Cases: Power distribution, motor feeders, control circuits, instrumentation, safety systems and communications throughout merchant ships and offshore installations.
N-CLASSIC-I 6Px1.5mm2 300/500V unverified
Cross Section (mm²)
1.5
Voltage Class
300/500V
Cores
6
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation deterioration caused by heat, oil, ultraviolet exposure, moisture or age, resulting in low insulation resistance, earth faults or intermittent trips
  • Termination overheating caused by loose lugs, corrosion or poor crimping, resulting in discoloration, odor or localized temperature rise
  • Mechanical damage caused by chafing, crushing, excessive bend or unsupported routing, resulting in exposed armor, sheath damage or conductor failure
  • Water ingress caused by damaged glands, sheath or deck penetrations, resulting in corrosion, leakage current or communication faults
  • Screening, grounding or fire-seal deficiency caused by incorrect installation or maintenance, resulting in interference, poor fault protection or reduced fire integrity
Service: Inspect visible cable runs, supports, glands, terminations, penetrations and fire stops for damage, corrosion, overheating and unauthorized modifications. Maintain bend radius and support without imposing strain on equipment terminals. Check insulation resistance or continuity using procedures suitable for connected equipment and isolate sensitive electronics when required. Inspect cable glands and deck penetrations for water ingress and verify screens and armor are terminated according to the approved design. Replace damaged cable with an approved equivalent rather than patching critical insulation casually. Refer to the manufacturer documentation for the exact figure for conductor ratings, bend radius and test limits.
Spare Parts: Keep suitable lengths of approved cable for critical services together with glands, lugs, ferrules, heat-shrink, identification materials and certified fire-stop products appropriate to the installation. Communication and fire-resistant cable replacements must preserve required screening and approval. Verify voltage, conductor size and material before use.
Use Cases: Power distribution, motor feeders, control circuits, instrumentation, safety systems and communications throughout merchant ships and offshore installations.
N-CLASSIC-I 8Px1.5mm2 300/500V unverified
Cross Section (mm²)
1.5
Voltage Class
300/500V
Cores
8
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation deterioration caused by heat, oil, ultraviolet exposure, moisture or age, resulting in low insulation resistance, earth faults or intermittent trips
  • Termination overheating caused by loose lugs, corrosion or poor crimping, resulting in discoloration, odor or localized temperature rise
  • Mechanical damage caused by chafing, crushing, excessive bend or unsupported routing, resulting in exposed armor, sheath damage or conductor failure
  • Water ingress caused by damaged glands, sheath or deck penetrations, resulting in corrosion, leakage current or communication faults
  • Screening, grounding or fire-seal deficiency caused by incorrect installation or maintenance, resulting in interference, poor fault protection or reduced fire integrity
Service: Inspect visible cable runs, supports, glands, terminations, penetrations and fire stops for damage, corrosion, overheating and unauthorized modifications. Maintain bend radius and support without imposing strain on equipment terminals. Check insulation resistance or continuity using procedures suitable for connected equipment and isolate sensitive electronics when required. Inspect cable glands and deck penetrations for water ingress and verify screens and armor are terminated according to the approved design. Replace damaged cable with an approved equivalent rather than patching critical insulation casually. Refer to the manufacturer documentation for the exact figure for conductor ratings, bend radius and test limits.
Spare Parts: Keep suitable lengths of approved cable for critical services together with glands, lugs, ferrules, heat-shrink, identification materials and certified fire-stop products appropriate to the installation. Communication and fire-resistant cable replacements must preserve required screening and approval. Verify voltage, conductor size and material before use.
Use Cases: Power distribution, motor feeders, control circuits, instrumentation, safety systems and communications throughout merchant ships and offshore installations.
N-CLASSIC-I 12Px1.5mm2 300/500V unverified
Cross Section (mm²)
1.5
Voltage Class
300/500V
Cores
12
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation deterioration caused by heat, oil, ultraviolet exposure, moisture or age, resulting in low insulation resistance, earth faults or intermittent trips
  • Termination overheating caused by loose lugs, corrosion or poor crimping, resulting in discoloration, odor or localized temperature rise
  • Mechanical damage caused by chafing, crushing, excessive bend or unsupported routing, resulting in exposed armor, sheath damage or conductor failure
  • Water ingress caused by damaged glands, sheath or deck penetrations, resulting in corrosion, leakage current or communication faults
  • Screening, grounding or fire-seal deficiency caused by incorrect installation or maintenance, resulting in interference, poor fault protection or reduced fire integrity
Service: Inspect visible cable runs, supports, glands, terminations, penetrations and fire stops for damage, corrosion, overheating and unauthorized modifications. Maintain bend radius and support without imposing strain on equipment terminals. Check insulation resistance or continuity using procedures suitable for connected equipment and isolate sensitive electronics when required. Inspect cable glands and deck penetrations for water ingress and verify screens and armor are terminated according to the approved design. Replace damaged cable with an approved equivalent rather than patching critical insulation casually. Refer to the manufacturer documentation for the exact figure for conductor ratings, bend radius and test limits.
Spare Parts: Keep suitable lengths of approved cable for critical services together with glands, lugs, ferrules, heat-shrink, identification materials and certified fire-stop products appropriate to the installation. Communication and fire-resistant cable replacements must preserve required screening and approval. Verify voltage, conductor size and material before use.
Use Cases: Power distribution, motor feeders, control circuits, instrumentation, safety systems and communications throughout merchant ships and offshore installations.
N-CLASSIC-I 2Px2.5mm2 300/500V unverified
Cross Section (mm²)
2.5
Voltage Class
300/500V
Cores
2
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation deterioration caused by heat, oil, ultraviolet exposure, moisture or age, resulting in low insulation resistance, earth faults or intermittent trips
  • Termination overheating caused by loose lugs, corrosion or poor crimping, resulting in discoloration, odor or localized temperature rise
  • Mechanical damage caused by chafing, crushing, excessive bend or unsupported routing, resulting in exposed armor, sheath damage or conductor failure
  • Water ingress caused by damaged glands, sheath or deck penetrations, resulting in corrosion, leakage current or communication faults
  • Screening, grounding or fire-seal deficiency caused by incorrect installation or maintenance, resulting in interference, poor fault protection or reduced fire integrity
Service: Inspect visible cable runs, supports, glands, terminations, penetrations and fire stops for damage, corrosion, overheating and unauthorized modifications. Maintain bend radius and support without imposing strain on equipment terminals. Check insulation resistance or continuity using procedures suitable for connected equipment and isolate sensitive electronics when required. Inspect cable glands and deck penetrations for water ingress and verify screens and armor are terminated according to the approved design. Replace damaged cable with an approved equivalent rather than patching critical insulation casually. Refer to the manufacturer documentation for the exact figure for conductor ratings, bend radius and test limits.
Spare Parts: Keep suitable lengths of approved cable for critical services together with glands, lugs, ferrules, heat-shrink, identification materials and certified fire-stop products appropriate to the installation. Communication and fire-resistant cable replacements must preserve required screening and approval. Verify voltage, conductor size and material before use.
Use Cases: Power distribution, motor feeders, control circuits, instrumentation, safety systems and communications throughout merchant ships and offshore installations.
N-CLASSIC-I 4Px2.5mm2 300/500V unverified
Cross Section (mm²)
2.5
Voltage Class
300/500V
Cores
4
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation deterioration caused by heat, oil, ultraviolet exposure, moisture or age, resulting in low insulation resistance, earth faults or intermittent trips
  • Termination overheating caused by loose lugs, corrosion or poor crimping, resulting in discoloration, odor or localized temperature rise
  • Mechanical damage caused by chafing, crushing, excessive bend or unsupported routing, resulting in exposed armor, sheath damage or conductor failure
  • Water ingress caused by damaged glands, sheath or deck penetrations, resulting in corrosion, leakage current or communication faults
  • Screening, grounding or fire-seal deficiency caused by incorrect installation or maintenance, resulting in interference, poor fault protection or reduced fire integrity
Service: Inspect visible cable runs, supports, glands, terminations, penetrations and fire stops for damage, corrosion, overheating and unauthorized modifications. Maintain bend radius and support without imposing strain on equipment terminals. Check insulation resistance or continuity using procedures suitable for connected equipment and isolate sensitive electronics when required. Inspect cable glands and deck penetrations for water ingress and verify screens and armor are terminated according to the approved design. Replace damaged cable with an approved equivalent rather than patching critical insulation casually. Refer to the manufacturer documentation for the exact figure for conductor ratings, bend radius and test limits.
Spare Parts: Keep suitable lengths of approved cable for critical services together with glands, lugs, ferrules, heat-shrink, identification materials and certified fire-stop products appropriate to the installation. Communication and fire-resistant cable replacements must preserve required screening and approval. Verify voltage, conductor size and material before use.
Use Cases: Power distribution, motor feeders, control circuits, instrumentation, safety systems and communications throughout merchant ships and offshore installations.
N-CLASSIC-I 6Px2.5mm2 300/500V unverified
Cross Section (mm²)
2.5
Voltage Class
300/500V
Cores
6
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation deterioration caused by heat, oil, ultraviolet exposure, moisture or age, resulting in low insulation resistance, earth faults or intermittent trips
  • Termination overheating caused by loose lugs, corrosion or poor crimping, resulting in discoloration, odor or localized temperature rise
  • Mechanical damage caused by chafing, crushing, excessive bend or unsupported routing, resulting in exposed armor, sheath damage or conductor failure
  • Water ingress caused by damaged glands, sheath or deck penetrations, resulting in corrosion, leakage current or communication faults
  • Screening, grounding or fire-seal deficiency caused by incorrect installation or maintenance, resulting in interference, poor fault protection or reduced fire integrity
Service: Inspect visible cable runs, supports, glands, terminations, penetrations and fire stops for damage, corrosion, overheating and unauthorized modifications. Maintain bend radius and support without imposing strain on equipment terminals. Check insulation resistance or continuity using procedures suitable for connected equipment and isolate sensitive electronics when required. Inspect cable glands and deck penetrations for water ingress and verify screens and armor are terminated according to the approved design. Replace damaged cable with an approved equivalent rather than patching critical insulation casually. Refer to the manufacturer documentation for the exact figure for conductor ratings, bend radius and test limits.
Spare Parts: Keep suitable lengths of approved cable for critical services together with glands, lugs, ferrules, heat-shrink, identification materials and certified fire-stop products appropriate to the installation. Communication and fire-resistant cable replacements must preserve required screening and approval. Verify voltage, conductor size and material before use.
Use Cases: Power distribution, motor feeders, control circuits, instrumentation, safety systems and communications throughout merchant ships and offshore installations.
N-CLASSIC-I 8Px2.5mm2 300/500V unverified
Cross Section (mm²)
2.5
Voltage Class
300/500V
Cores
8
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation deterioration caused by heat, oil, ultraviolet exposure, moisture or age, resulting in low insulation resistance, earth faults or intermittent trips
  • Termination overheating caused by loose lugs, corrosion or poor crimping, resulting in discoloration, odor or localized temperature rise
  • Mechanical damage caused by chafing, crushing, excessive bend or unsupported routing, resulting in exposed armor, sheath damage or conductor failure
  • Water ingress caused by damaged glands, sheath or deck penetrations, resulting in corrosion, leakage current or communication faults
  • Screening, grounding or fire-seal deficiency caused by incorrect installation or maintenance, resulting in interference, poor fault protection or reduced fire integrity
Service: Inspect visible cable runs, supports, glands, terminations, penetrations and fire stops for damage, corrosion, overheating and unauthorized modifications. Maintain bend radius and support without imposing strain on equipment terminals. Check insulation resistance or continuity using procedures suitable for connected equipment and isolate sensitive electronics when required. Inspect cable glands and deck penetrations for water ingress and verify screens and armor are terminated according to the approved design. Replace damaged cable with an approved equivalent rather than patching critical insulation casually. Refer to the manufacturer documentation for the exact figure for conductor ratings, bend radius and test limits.
Spare Parts: Keep suitable lengths of approved cable for critical services together with glands, lugs, ferrules, heat-shrink, identification materials and certified fire-stop products appropriate to the installation. Communication and fire-resistant cable replacements must preserve required screening and approval. Verify voltage, conductor size and material before use.
Use Cases: Power distribution, motor feeders, control circuits, instrumentation, safety systems and communications throughout merchant ships and offshore installations.
N-CLASSIC-I 12Px2.5mm2 300/500V unverified
Cross Section (mm²)
2.5
Voltage Class
300/500V
Cores
12
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation deterioration caused by heat, oil, ultraviolet exposure, moisture or age, resulting in low insulation resistance, earth faults or intermittent trips
  • Termination overheating caused by loose lugs, corrosion or poor crimping, resulting in discoloration, odor or localized temperature rise
  • Mechanical damage caused by chafing, crushing, excessive bend or unsupported routing, resulting in exposed armor, sheath damage or conductor failure
  • Water ingress caused by damaged glands, sheath or deck penetrations, resulting in corrosion, leakage current or communication faults
  • Screening, grounding or fire-seal deficiency caused by incorrect installation or maintenance, resulting in interference, poor fault protection or reduced fire integrity
Service: Inspect visible cable runs, supports, glands, terminations, penetrations and fire stops for damage, corrosion, overheating and unauthorized modifications. Maintain bend radius and support without imposing strain on equipment terminals. Check insulation resistance or continuity using procedures suitable for connected equipment and isolate sensitive electronics when required. Inspect cable glands and deck penetrations for water ingress and verify screens and armor are terminated according to the approved design. Replace damaged cable with an approved equivalent rather than patching critical insulation casually. Refer to the manufacturer documentation for the exact figure for conductor ratings, bend radius and test limits.
Spare Parts: Keep suitable lengths of approved cable for critical services together with glands, lugs, ferrules, heat-shrink, identification materials and certified fire-stop products appropriate to the installation. Communication and fire-resistant cable replacements must preserve required screening and approval. Verify voltage, conductor size and material before use.
Use Cases: Power distribution, motor feeders, control circuits, instrumentation, safety systems and communications throughout merchant ships and offshore installations.

Prysmian

10
BFCU-I 2Px1.5mm2 300/500V unverified
Cross Section (mm²)
1.5
Voltage Class
300/500V
Cores
2
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation deterioration from heat, oil, chemicals, UV exposure or ageing, typically indicated by low insulation resistance, earth-fault alarms or visible cracking
  • Mechanical damage from chafing, crushing or poor support, typically indicated by exposed armour or conductors, intermittent faults or short circuits
  • Water ingress through damaged glands or transits, typically indicated by corrosion, insulation alarms or intermittent operation
  • Loose or overheated terminations from poor tightening or excessive current, typically indicated by discoloration, hot spots, voltage drop or burnt insulation
  • Shielding, armour or bonding discontinuity from corrosion or incorrect termination, typically indicated by electrical noise, unreliable signals or failed protective bonding checks
Service: Inspect cable routes, supports, bending, glands, armour or screens, fire-stop transits and terminations; perform insulation, continuity or functional testing as appropriate and use manufacturer/class documentation for exact acceptance values.
Spare Parts: Keep approved cable glands, lugs, ferrules, heat-shrink, transit inserts or sealing modules and suitable lengths of critical cable types used on board.
Use Cases: Used in all vessel electrical, automation, propulsion, communication and safety systems, with the exact cable type selected for voltage, fire performance and signal duty. This entry applies specifically to the Instrumentation Cable variant identified as Prysmian BFCU-I 2Px1.5mm2 300/500V.
BFCU-I 4Px1.5mm2 300/500V unverified
Cross Section (mm²)
1.5
Voltage Class
300/500V
Cores
4
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation deterioration from heat, oil, chemicals, UV exposure or ageing, typically indicated by low insulation resistance, earth-fault alarms or visible cracking
  • Mechanical damage from chafing, crushing or poor support, typically indicated by exposed armour or conductors, intermittent faults or short circuits
  • Water ingress through damaged glands or transits, typically indicated by corrosion, insulation alarms or intermittent operation
  • Loose or overheated terminations from poor tightening or excessive current, typically indicated by discoloration, hot spots, voltage drop or burnt insulation
  • Shielding, armour or bonding discontinuity from corrosion or incorrect termination, typically indicated by electrical noise, unreliable signals or failed protective bonding checks
Service: Inspect cable routes, supports, bending, glands, armour or screens, fire-stop transits and terminations; perform insulation, continuity or functional testing as appropriate and use manufacturer/class documentation for exact acceptance values.
Spare Parts: Keep approved cable glands, lugs, ferrules, heat-shrink, transit inserts or sealing modules and suitable lengths of critical cable types used on board.
Use Cases: Used in all vessel electrical, automation, propulsion, communication and safety systems, with the exact cable type selected for voltage, fire performance and signal duty. This entry applies specifically to the Instrumentation Cable variant identified as Prysmian BFCU-I 4Px1.5mm2 300/500V.
BFCU-I 6Px1.5mm2 300/500V unverified
Cross Section (mm²)
1.5
Voltage Class
300/500V
Cores
6
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation deterioration from heat, oil, chemicals, UV exposure or ageing, typically indicated by low insulation resistance, earth-fault alarms or visible cracking
  • Mechanical damage from chafing, crushing or poor support, typically indicated by exposed armour or conductors, intermittent faults or short circuits
  • Water ingress through damaged glands or transits, typically indicated by corrosion, insulation alarms or intermittent operation
  • Loose or overheated terminations from poor tightening or excessive current, typically indicated by discoloration, hot spots, voltage drop or burnt insulation
  • Shielding, armour or bonding discontinuity from corrosion or incorrect termination, typically indicated by electrical noise, unreliable signals or failed protective bonding checks
Service: Inspect cable routes, supports, bending, glands, armour or screens, fire-stop transits and terminations; perform insulation, continuity or functional testing as appropriate and use manufacturer/class documentation for exact acceptance values.
Spare Parts: Keep approved cable glands, lugs, ferrules, heat-shrink, transit inserts or sealing modules and suitable lengths of critical cable types used on board.
Use Cases: Used in all vessel electrical, automation, propulsion, communication and safety systems, with the exact cable type selected for voltage, fire performance and signal duty. This entry applies specifically to the Instrumentation Cable variant identified as Prysmian BFCU-I 6Px1.5mm2 300/500V.
BFCU-I 8Px1.5mm2 300/500V unverified
Cross Section (mm²)
1.5
Voltage Class
300/500V
Cores
8
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation deterioration from heat, oil, chemicals, UV exposure or ageing, typically indicated by low insulation resistance, earth-fault alarms or visible cracking
  • Mechanical damage from chafing, crushing or poor support, typically indicated by exposed armour or conductors, intermittent faults or short circuits
  • Water ingress through damaged glands or transits, typically indicated by corrosion, insulation alarms or intermittent operation
  • Loose or overheated terminations from poor tightening or excessive current, typically indicated by discoloration, hot spots, voltage drop or burnt insulation
  • Shielding, armour or bonding discontinuity from corrosion or incorrect termination, typically indicated by electrical noise, unreliable signals or failed protective bonding checks
Service: Inspect cable routes, supports, bending, glands, armour or screens, fire-stop transits and terminations; perform insulation, continuity or functional testing as appropriate and use manufacturer/class documentation for exact acceptance values.
Spare Parts: Keep approved cable glands, lugs, ferrules, heat-shrink, transit inserts or sealing modules and suitable lengths of critical cable types used on board.
Use Cases: Used in all vessel electrical, automation, propulsion, communication and safety systems, with the exact cable type selected for voltage, fire performance and signal duty. This entry applies specifically to the Instrumentation Cable variant identified as Prysmian BFCU-I 8Px1.5mm2 300/500V.
BFCU-I 12Px1.5mm2 300/500V unverified
Cross Section (mm²)
1.5
Voltage Class
300/500V
Cores
12
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation deterioration from heat, oil, chemicals, UV exposure or ageing, typically indicated by low insulation resistance, earth-fault alarms or visible cracking
  • Mechanical damage from chafing, crushing or poor support, typically indicated by exposed armour or conductors, intermittent faults or short circuits
  • Water ingress through damaged glands or transits, typically indicated by corrosion, insulation alarms or intermittent operation
  • Loose or overheated terminations from poor tightening or excessive current, typically indicated by discoloration, hot spots, voltage drop or burnt insulation
  • Shielding, armour or bonding discontinuity from corrosion or incorrect termination, typically indicated by electrical noise, unreliable signals or failed protective bonding checks
Service: Inspect cable routes, supports, bending, glands, armour or screens, fire-stop transits and terminations; perform insulation, continuity or functional testing as appropriate and use manufacturer/class documentation for exact acceptance values.
Spare Parts: Keep approved cable glands, lugs, ferrules, heat-shrink, transit inserts or sealing modules and suitable lengths of critical cable types used on board.
Use Cases: Used in all vessel electrical, automation, propulsion, communication and safety systems, with the exact cable type selected for voltage, fire performance and signal duty. This entry applies specifically to the Instrumentation Cable variant identified as Prysmian BFCU-I 12Px1.5mm2 300/500V.
BFCU-I 2Px2.5mm2 300/500V unverified
Cross Section (mm²)
2.5
Voltage Class
300/500V
Cores
2
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation deterioration from heat, oil, chemicals, UV exposure or ageing, typically indicated by low insulation resistance, earth-fault alarms or visible cracking
  • Mechanical damage from chafing, crushing or poor support, typically indicated by exposed armour or conductors, intermittent faults or short circuits
  • Water ingress through damaged glands or transits, typically indicated by corrosion, insulation alarms or intermittent operation
  • Loose or overheated terminations from poor tightening or excessive current, typically indicated by discoloration, hot spots, voltage drop or burnt insulation
  • Shielding, armour or bonding discontinuity from corrosion or incorrect termination, typically indicated by electrical noise, unreliable signals or failed protective bonding checks
Service: Inspect cable routes, supports, bending, glands, armour or screens, fire-stop transits and terminations; perform insulation, continuity or functional testing as appropriate and use manufacturer/class documentation for exact acceptance values.
Spare Parts: Keep approved cable glands, lugs, ferrules, heat-shrink, transit inserts or sealing modules and suitable lengths of critical cable types used on board.
Use Cases: Used in all vessel electrical, automation, propulsion, communication and safety systems, with the exact cable type selected for voltage, fire performance and signal duty. This entry applies specifically to the Instrumentation Cable variant identified as Prysmian BFCU-I 2Px2.5mm2 300/500V.
BFCU-I 4Px2.5mm2 300/500V unverified
Cross Section (mm²)
2.5
Voltage Class
300/500V
Cores
4
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation deterioration from heat, oil, chemicals, UV exposure or ageing, typically indicated by low insulation resistance, earth-fault alarms or visible cracking
  • Mechanical damage from chafing, crushing or poor support, typically indicated by exposed armour or conductors, intermittent faults or short circuits
  • Water ingress through damaged glands or transits, typically indicated by corrosion, insulation alarms or intermittent operation
  • Loose or overheated terminations from poor tightening or excessive current, typically indicated by discoloration, hot spots, voltage drop or burnt insulation
  • Shielding, armour or bonding discontinuity from corrosion or incorrect termination, typically indicated by electrical noise, unreliable signals or failed protective bonding checks
Service: Inspect cable routes, supports, bending, glands, armour or screens, fire-stop transits and terminations; perform insulation, continuity or functional testing as appropriate and use manufacturer/class documentation for exact acceptance values.
Spare Parts: Keep approved cable glands, lugs, ferrules, heat-shrink, transit inserts or sealing modules and suitable lengths of critical cable types used on board.
Use Cases: Used in all vessel electrical, automation, propulsion, communication and safety systems, with the exact cable type selected for voltage, fire performance and signal duty. This entry applies specifically to the Instrumentation Cable variant identified as Prysmian BFCU-I 4Px2.5mm2 300/500V.
BFCU-I 6Px2.5mm2 300/500V unverified
Cross Section (mm²)
2.5
Voltage Class
300/500V
Cores
6
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation deterioration from heat, oil, chemicals, UV exposure or ageing, typically indicated by low insulation resistance, earth-fault alarms or visible cracking
  • Mechanical damage from chafing, crushing or poor support, typically indicated by exposed armour or conductors, intermittent faults or short circuits
  • Water ingress through damaged glands or transits, typically indicated by corrosion, insulation alarms or intermittent operation
  • Loose or overheated terminations from poor tightening or excessive current, typically indicated by discoloration, hot spots, voltage drop or burnt insulation
  • Shielding, armour or bonding discontinuity from corrosion or incorrect termination, typically indicated by electrical noise, unreliable signals or failed protective bonding checks
Service: Inspect cable routes, supports, bending, glands, armour or screens, fire-stop transits and terminations; perform insulation, continuity or functional testing as appropriate and use manufacturer/class documentation for exact acceptance values.
Spare Parts: Keep approved cable glands, lugs, ferrules, heat-shrink, transit inserts or sealing modules and suitable lengths of critical cable types used on board.
Use Cases: Used in all vessel electrical, automation, propulsion, communication and safety systems, with the exact cable type selected for voltage, fire performance and signal duty. This entry applies specifically to the Instrumentation Cable variant identified as Prysmian BFCU-I 6Px2.5mm2 300/500V.
BFCU-I 8Px2.5mm2 300/500V unverified
Cross Section (mm²)
2.5
Voltage Class
300/500V
Cores
8
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation deterioration from heat, oil, chemicals, UV exposure or ageing, typically indicated by low insulation resistance, earth-fault alarms or visible cracking
  • Mechanical damage from chafing, crushing or poor support, typically indicated by exposed armour or conductors, intermittent faults or short circuits
  • Water ingress through damaged glands or transits, typically indicated by corrosion, insulation alarms or intermittent operation
  • Loose or overheated terminations from poor tightening or excessive current, typically indicated by discoloration, hot spots, voltage drop or burnt insulation
  • Shielding, armour or bonding discontinuity from corrosion or incorrect termination, typically indicated by electrical noise, unreliable signals or failed protective bonding checks
Service: Inspect cable routes, supports, bending, glands, armour or screens, fire-stop transits and terminations; perform insulation, continuity or functional testing as appropriate and use manufacturer/class documentation for exact acceptance values.
Spare Parts: Keep approved cable glands, lugs, ferrules, heat-shrink, transit inserts or sealing modules and suitable lengths of critical cable types used on board.
Use Cases: Used in all vessel electrical, automation, propulsion, communication and safety systems, with the exact cable type selected for voltage, fire performance and signal duty. This entry applies specifically to the Instrumentation Cable variant identified as Prysmian BFCU-I 8Px2.5mm2 300/500V.
BFCU-I 12Px2.5mm2 300/500V unverified
Cross Section (mm²)
2.5
Voltage Class
300/500V
Cores
12
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation deterioration from heat, oil, chemicals, UV exposure or ageing, typically indicated by low insulation resistance, earth-fault alarms or visible cracking
  • Mechanical damage from chafing, crushing or poor support, typically indicated by exposed armour or conductors, intermittent faults or short circuits
  • Water ingress through damaged glands or transits, typically indicated by corrosion, insulation alarms or intermittent operation
  • Loose or overheated terminations from poor tightening or excessive current, typically indicated by discoloration, hot spots, voltage drop or burnt insulation
  • Shielding, armour or bonding discontinuity from corrosion or incorrect termination, typically indicated by electrical noise, unreliable signals or failed protective bonding checks
Service: Inspect cable routes, supports, bending, glands, armour or screens, fire-stop transits and terminations; perform insulation, continuity or functional testing as appropriate and use manufacturer/class documentation for exact acceptance values.
Spare Parts: Keep approved cable glands, lugs, ferrules, heat-shrink, transit inserts or sealing modules and suitable lengths of critical cable types used on board.
Use Cases: Used in all vessel electrical, automation, propulsion, communication and safety systems, with the exact cable type selected for voltage, fire performance and signal duty. This entry applies specifically to the Instrumentation Cable variant identified as Prysmian BFCU-I 12Px2.5mm2 300/500V.

Studer Cables

10
BETAflam-I 2Px1.5mm2 300/500V unverified
Cross Section (mm²)
1.5
Voltage Class
300/500V
Cores
2
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation deterioration caused by heat, oil, ultraviolet exposure, moisture or age, resulting in low insulation resistance, earth faults or intermittent trips
  • Termination overheating caused by loose lugs, corrosion or poor crimping, resulting in discoloration, odor or localized temperature rise
  • Mechanical damage caused by chafing, crushing, excessive bend or unsupported routing, resulting in exposed armor, sheath damage or conductor failure
  • Water ingress caused by damaged glands, sheath or deck penetrations, resulting in corrosion, leakage current or communication faults
  • Screening, grounding or fire-seal deficiency caused by incorrect installation or maintenance, resulting in interference, poor fault protection or reduced fire integrity
Service: Inspect visible cable runs, supports, glands, terminations, penetrations and fire stops for damage, corrosion, overheating and unauthorized modifications. Maintain bend radius and support without imposing strain on equipment terminals. Check insulation resistance or continuity using procedures suitable for connected equipment and isolate sensitive electronics when required. Inspect cable glands and deck penetrations for water ingress and verify screens and armor are terminated according to the approved design. Replace damaged cable with an approved equivalent rather than patching critical insulation casually. Refer to the manufacturer documentation for the exact figure for conductor ratings, bend radius and test limits.
Spare Parts: Keep suitable lengths of approved cable for critical services together with glands, lugs, ferrules, heat-shrink, identification materials and certified fire-stop products appropriate to the installation. Communication and fire-resistant cable replacements must preserve required screening and approval. Verify voltage, conductor size and material before use.
Use Cases: Power distribution, motor feeders, control circuits, instrumentation, safety systems and communications throughout merchant ships and offshore installations.
BETAflam-I 4Px1.5mm2 300/500V unverified
Cross Section (mm²)
1.5
Voltage Class
300/500V
Cores
4
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation deterioration caused by heat, oil, ultraviolet exposure, moisture or age, resulting in low insulation resistance, earth faults or intermittent trips
  • Termination overheating caused by loose lugs, corrosion or poor crimping, resulting in discoloration, odor or localized temperature rise
  • Mechanical damage caused by chafing, crushing, excessive bend or unsupported routing, resulting in exposed armor, sheath damage or conductor failure
  • Water ingress caused by damaged glands, sheath or deck penetrations, resulting in corrosion, leakage current or communication faults
  • Screening, grounding or fire-seal deficiency caused by incorrect installation or maintenance, resulting in interference, poor fault protection or reduced fire integrity
Service: Inspect visible cable runs, supports, glands, terminations, penetrations and fire stops for damage, corrosion, overheating and unauthorized modifications. Maintain bend radius and support without imposing strain on equipment terminals. Check insulation resistance or continuity using procedures suitable for connected equipment and isolate sensitive electronics when required. Inspect cable glands and deck penetrations for water ingress and verify screens and armor are terminated according to the approved design. Replace damaged cable with an approved equivalent rather than patching critical insulation casually. Refer to the manufacturer documentation for the exact figure for conductor ratings, bend radius and test limits.
Spare Parts: Keep suitable lengths of approved cable for critical services together with glands, lugs, ferrules, heat-shrink, identification materials and certified fire-stop products appropriate to the installation. Communication and fire-resistant cable replacements must preserve required screening and approval. Verify voltage, conductor size and material before use.
Use Cases: Power distribution, motor feeders, control circuits, instrumentation, safety systems and communications throughout merchant ships and offshore installations.
BETAflam-I 6Px1.5mm2 300/500V unverified
Cross Section (mm²)
1.5
Voltage Class
300/500V
Cores
6
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation deterioration caused by heat, oil, ultraviolet exposure, moisture or age, resulting in low insulation resistance, earth faults or intermittent trips
  • Termination overheating caused by loose lugs, corrosion or poor crimping, resulting in discoloration, odor or localized temperature rise
  • Mechanical damage caused by chafing, crushing, excessive bend or unsupported routing, resulting in exposed armor, sheath damage or conductor failure
  • Water ingress caused by damaged glands, sheath or deck penetrations, resulting in corrosion, leakage current or communication faults
  • Screening, grounding or fire-seal deficiency caused by incorrect installation or maintenance, resulting in interference, poor fault protection or reduced fire integrity
Service: Inspect visible cable runs, supports, glands, terminations, penetrations and fire stops for damage, corrosion, overheating and unauthorized modifications. Maintain bend radius and support without imposing strain on equipment terminals. Check insulation resistance or continuity using procedures suitable for connected equipment and isolate sensitive electronics when required. Inspect cable glands and deck penetrations for water ingress and verify screens and armor are terminated according to the approved design. Replace damaged cable with an approved equivalent rather than patching critical insulation casually. Refer to the manufacturer documentation for the exact figure for conductor ratings, bend radius and test limits.
Spare Parts: Keep suitable lengths of approved cable for critical services together with glands, lugs, ferrules, heat-shrink, identification materials and certified fire-stop products appropriate to the installation. Communication and fire-resistant cable replacements must preserve required screening and approval. Verify voltage, conductor size and material before use.
Use Cases: Power distribution, motor feeders, control circuits, instrumentation, safety systems and communications throughout merchant ships and offshore installations.
BETAflam-I 8Px1.5mm2 300/500V unverified
Cross Section (mm²)
1.5
Voltage Class
300/500V
Cores
8
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation deterioration caused by heat, oil, ultraviolet exposure, moisture or age, resulting in low insulation resistance, earth faults or intermittent trips
  • Termination overheating caused by loose lugs, corrosion or poor crimping, resulting in discoloration, odor or localized temperature rise
  • Mechanical damage caused by chafing, crushing, excessive bend or unsupported routing, resulting in exposed armor, sheath damage or conductor failure
  • Water ingress caused by damaged glands, sheath or deck penetrations, resulting in corrosion, leakage current or communication faults
  • Screening, grounding or fire-seal deficiency caused by incorrect installation or maintenance, resulting in interference, poor fault protection or reduced fire integrity
Service: Inspect visible cable runs, supports, glands, terminations, penetrations and fire stops for damage, corrosion, overheating and unauthorized modifications. Maintain bend radius and support without imposing strain on equipment terminals. Check insulation resistance or continuity using procedures suitable for connected equipment and isolate sensitive electronics when required. Inspect cable glands and deck penetrations for water ingress and verify screens and armor are terminated according to the approved design. Replace damaged cable with an approved equivalent rather than patching critical insulation casually. Refer to the manufacturer documentation for the exact figure for conductor ratings, bend radius and test limits.
Spare Parts: Keep suitable lengths of approved cable for critical services together with glands, lugs, ferrules, heat-shrink, identification materials and certified fire-stop products appropriate to the installation. Communication and fire-resistant cable replacements must preserve required screening and approval. Verify voltage, conductor size and material before use.
Use Cases: Power distribution, motor feeders, control circuits, instrumentation, safety systems and communications throughout merchant ships and offshore installations.
BETAflam-I 12Px1.5mm2 300/500V unverified
Cross Section (mm²)
1.5
Voltage Class
300/500V
Cores
12
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation deterioration caused by heat, oil, ultraviolet exposure, moisture or age, resulting in low insulation resistance, earth faults or intermittent trips
  • Termination overheating caused by loose lugs, corrosion or poor crimping, resulting in discoloration, odor or localized temperature rise
  • Mechanical damage caused by chafing, crushing, excessive bend or unsupported routing, resulting in sheath damage, exposed armor or conductor failure
  • Water ingress caused by damaged glands, sheath or deck penetrations, resulting in corrosion, leakage current or communication faults
  • Screening, grounding or fire-seal deficiency caused by incorrect installation or maintenance, resulting in interference, poor fault protection or reduced fire integrity
Service: Inspect visible cable runs, supports, glands, terminations, penetrations and fire stops for damage, corrosion, overheating and unauthorized modifications. Maintain bend radius and support without imposing strain on equipment terminals. Check insulation resistance or continuity using procedures suitable for the connected equipment and isolate sensitive electronics when required. Inspect cable glands and deck penetrations for water ingress and verify screens and armor are terminated according to the approved design. Replace damaged cable with an approved equivalent rather than patching critical insulation casually. Refer to the manufacturer documentation for the exact figure for conductor ratings, bend radius and test limits.
Spare Parts: Keep suitable lengths of approved cable for critical services together with glands, lugs, ferrules, heat-shrink, identification materials and certified fire-stop products. Instrumentation and fire-resistant cable replacements must preserve required screening and approval.
Use Cases: It is used for shipboard power, control and communication circuits on merchant ships, passenger vessels, offshore units or other vessel types where this equipment category is fitted.
BETAflam-I 2Px2.5mm2 300/500V unverified
Cross Section (mm²)
2.5
Voltage Class
300/500V
Cores
2
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation deterioration caused by heat, oil, ultraviolet exposure, moisture or age, resulting in low insulation resistance, earth faults or intermittent trips
  • Termination overheating caused by loose lugs, corrosion or poor crimping, resulting in discoloration, odor or localized temperature rise
  • Mechanical damage caused by chafing, crushing, excessive bend or unsupported routing, resulting in exposed armor, sheath damage or conductor failure
  • Water ingress caused by damaged glands, sheath or deck penetrations, resulting in corrosion, leakage current or communication faults
  • Screening, grounding or fire-seal deficiency caused by incorrect installation or maintenance, resulting in interference, poor fault protection or reduced fire integrity
Service: Inspect visible cable runs, supports, glands, terminations, penetrations and fire stops for damage, corrosion, overheating and unauthorized modifications. Maintain bend radius and support without imposing strain on equipment terminals. Check insulation resistance or continuity using procedures suitable for connected equipment and isolate sensitive electronics when required. Inspect cable glands and deck penetrations for water ingress and verify screens and armor are terminated according to the approved design. Replace damaged cable with an approved equivalent rather than patching critical insulation casually. Refer to the manufacturer documentation for the exact figure for conductor ratings, bend radius and test limits.
Spare Parts: Keep suitable lengths of approved cable for critical services together with glands, lugs, ferrules, heat-shrink, identification materials and certified fire-stop products appropriate to the installation. Communication and fire-resistant cable replacements must preserve required screening and approval. Verify voltage, conductor size and material before use.
Use Cases: Power distribution, motor feeders, control circuits, instrumentation, safety systems and communications throughout merchant ships and offshore installations.
BETAflam-I 4Px2.5mm2 300/500V unverified
Cross Section (mm²)
2.5
Voltage Class
300/500V
Cores
4
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation deterioration caused by heat, oil, ultraviolet exposure, moisture or age, resulting in low insulation resistance, earth faults or intermittent trips
  • Termination overheating caused by loose lugs, corrosion or poor crimping, resulting in discoloration, odor or localized temperature rise
  • Mechanical damage caused by chafing, crushing, excessive bend or unsupported routing, resulting in exposed armor, sheath damage or conductor failure
  • Water ingress caused by damaged glands, sheath or deck penetrations, resulting in corrosion, leakage current or communication faults
  • Screening, grounding or fire-seal deficiency caused by incorrect installation or maintenance, resulting in interference, poor fault protection or reduced fire integrity
Service: Inspect visible cable runs, supports, glands, terminations, penetrations and fire stops for damage, corrosion, overheating and unauthorized modifications. Maintain bend radius and support without imposing strain on equipment terminals. Check insulation resistance or continuity using procedures suitable for connected equipment and isolate sensitive electronics when required. Inspect cable glands and deck penetrations for water ingress and verify screens and armor are terminated according to the approved design. Replace damaged cable with an approved equivalent rather than patching critical insulation casually. Refer to the manufacturer documentation for the exact figure for conductor ratings, bend radius and test limits.
Spare Parts: Keep suitable lengths of approved cable for critical services together with glands, lugs, ferrules, heat-shrink, identification materials and certified fire-stop products appropriate to the installation. Communication and fire-resistant cable replacements must preserve required screening and approval. Verify voltage, conductor size and material before use.
Use Cases: Power distribution, motor feeders, control circuits, instrumentation, safety systems and communications throughout merchant ships and offshore installations.
BETAflam-I 6Px2.5mm2 300/500V unverified
Cross Section (mm²)
2.5
Voltage Class
300/500V
Cores
6
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation deterioration caused by heat, oil, ultraviolet exposure, moisture or age, resulting in low insulation resistance, earth faults or intermittent trips
  • Termination overheating caused by loose lugs, corrosion or poor crimping, resulting in discoloration, odor or localized temperature rise
  • Mechanical damage caused by chafing, crushing, excessive bend or unsupported routing, resulting in exposed armor, sheath damage or conductor failure
  • Water ingress caused by damaged glands, sheath or deck penetrations, resulting in corrosion, leakage current or communication faults
  • Screening, grounding or fire-seal deficiency caused by incorrect installation or maintenance, resulting in interference, poor fault protection or reduced fire integrity
Service: Inspect visible cable runs, supports, glands, terminations, penetrations and fire stops for damage, corrosion, overheating and unauthorized modifications. Maintain bend radius and support without imposing strain on equipment terminals. Check insulation resistance or continuity using procedures suitable for connected equipment and isolate sensitive electronics when required. Inspect cable glands and deck penetrations for water ingress and verify screens and armor are terminated according to the approved design. Replace damaged cable with an approved equivalent rather than patching critical insulation casually. Refer to the manufacturer documentation for the exact figure for conductor ratings, bend radius and test limits.
Spare Parts: Keep suitable lengths of approved cable for critical services together with glands, lugs, ferrules, heat-shrink, identification materials and certified fire-stop products appropriate to the installation. Communication and fire-resistant cable replacements must preserve required screening and approval. Verify voltage, conductor size and material before use.
Use Cases: Power distribution, motor feeders, control circuits, instrumentation, safety systems and communications throughout merchant ships and offshore installations.
BETAflam-I 8Px2.5mm2 300/500V unverified
Cross Section (mm²)
2.5
Voltage Class
300/500V
Cores
8
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation deterioration caused by heat, oil, ultraviolet exposure, moisture or age, resulting in low insulation resistance, earth faults or intermittent trips
  • Termination overheating caused by loose lugs, corrosion or poor crimping, resulting in discoloration, odor or localized temperature rise
  • Mechanical damage caused by chafing, crushing, excessive bend or unsupported routing, resulting in exposed armor, sheath damage or conductor failure
  • Water ingress caused by damaged glands, sheath or deck penetrations, resulting in corrosion, leakage current or communication faults
  • Screening, grounding or fire-seal deficiency caused by incorrect installation or maintenance, resulting in interference, poor fault protection or reduced fire integrity
Service: Inspect visible cable runs, supports, glands, terminations, penetrations and fire stops for damage, corrosion, overheating and unauthorized modifications. Maintain bend radius and support without imposing strain on equipment terminals. Check insulation resistance or continuity using procedures suitable for connected equipment and isolate sensitive electronics when required. Inspect cable glands and deck penetrations for water ingress and verify screens and armor are terminated according to the approved design. Replace damaged cable with an approved equivalent rather than patching critical insulation casually. Refer to the manufacturer documentation for the exact figure for conductor ratings, bend radius and test limits.
Spare Parts: Keep suitable lengths of approved cable for critical services together with glands, lugs, ferrules, heat-shrink, identification materials and certified fire-stop products appropriate to the installation. Communication and fire-resistant cable replacements must preserve required screening and approval. Verify voltage, conductor size and material before use.
Use Cases: Power distribution, motor feeders, control circuits, instrumentation, safety systems and communications throughout merchant ships and offshore installations.
BETAflam-I 12Px2.5mm2 300/500V unverified
Cross Section (mm²)
2.5
Voltage Class
300/500V
Cores
12
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation deterioration caused by heat, oil, ultraviolet exposure, moisture or age, resulting in low insulation resistance, earth faults or intermittent trips
  • Termination overheating caused by loose lugs, corrosion or poor crimping, resulting in discoloration, odor or localized temperature rise
  • Mechanical damage caused by chafing, crushing, excessive bend or unsupported routing, resulting in sheath damage, exposed armor or conductor failure
  • Water ingress caused by damaged glands, sheath or deck penetrations, resulting in corrosion, leakage current or communication faults
  • Screening, grounding or fire-seal deficiency caused by incorrect installation or maintenance, resulting in interference, poor fault protection or reduced fire integrity
Service: Inspect visible cable runs, supports, glands, terminations, penetrations and fire stops for damage, corrosion, overheating and unauthorized modifications. Maintain bend radius and support without imposing strain on equipment terminals. Check insulation resistance or continuity using procedures suitable for the connected equipment and isolate sensitive electronics when required. Inspect cable glands and deck penetrations for water ingress and verify screens and armor are terminated according to the approved design. Replace damaged cable with an approved equivalent rather than patching critical insulation casually. Refer to the manufacturer documentation for the exact figure for conductor ratings, bend radius and test limits.
Spare Parts: Keep suitable lengths of approved cable for critical services together with glands, lugs, ferrules, heat-shrink, identification materials and certified fire-stop products. Instrumentation and fire-resistant cable replacements must preserve required screening and approval.
Use Cases: It is used for shipboard power, control and communication circuits on merchant ships, passenger vessels, offshore units or other vessel types where this equipment category is fitted.

TKF/TKD

10
S7-I 2Px1.5mm2 300/500V unverified
Cross Section (mm²)
1.5
Voltage Class
300/500V
Cores
2
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation damage from heat, abrasion, oil, chemicals, or mechanical impact causes earth faults, leakage current, or intermittent circuits
  • Loose or corroded terminations increase contact resistance and appear as heating, voltage drop, or unstable signals
  • Water ingress through glands, junction boxes, or damaged sheath causes corrosion, insulation deterioration, or repeated electrical faults
  • Excessive bending, unsupported runs, or vibration damages conductors or shielding and can produce intermittent open circuits
  • Fire or thermal exposure beyond the cable's design condition can degrade insulation and lead to loss of continuity or short circuit
Service: Inspect accessible routes, support spacing, bend condition, segregation, glands, penetrations, fire stops, sheath damage, terminations, earthing or shielding, and signs of overheating. Insulation and continuity testing must suit the circuit and connected equipment; refer to approved cable data for exact test voltages and installation limits.
Spare Parts: Keep approved glands, lugs, ferrules, terminals, junction-box sealing items, repair sleeves where permitted, and suitable replacement cable of the exact approved type and rating.
Use Cases: Used throughout all vessel types for power distribution, control, instrumentation, communications, safety systems, and emergency circuits.
S7-I 4Px1.5mm2 300/500V unverified
Cross Section (mm²)
1.5
Voltage Class
300/500V
Cores
4
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation damage from heat, abrasion, oil, chemicals, or mechanical impact causes earth faults, leakage current, or intermittent circuits
  • Loose or corroded terminations increase contact resistance and appear as heating, voltage drop, or unstable signals
  • Water ingress through glands, junction boxes, or damaged sheath causes corrosion, insulation deterioration, or repeated electrical faults
  • Excessive bending, unsupported runs, or vibration damages conductors or shielding and can produce intermittent open circuits
  • Fire or thermal exposure beyond the cable's design condition can degrade insulation and lead to loss of continuity or short circuit
Service: Inspect accessible routes, support spacing, bend condition, segregation, glands, penetrations, fire stops, sheath damage, terminations, earthing or shielding, and signs of overheating. Insulation and continuity testing must suit the circuit and connected equipment; refer to approved cable data for exact test voltages and installation limits.
Spare Parts: Keep approved glands, lugs, ferrules, terminals, junction-box sealing items, repair sleeves where permitted, and suitable replacement cable of the exact approved type and rating.
Use Cases: Used throughout all vessel types for power distribution, control, instrumentation, communications, safety systems, and emergency circuits.
S7-I 6Px1.5mm2 300/500V unverified
Cross Section (mm²)
1.5
Voltage Class
300/500V
Cores
6
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation damage from heat, abrasion, oil, chemicals, or mechanical impact causes earth faults, leakage current, or intermittent circuits
  • Loose or corroded terminations increase contact resistance and appear as heating, voltage drop, or unstable signals
  • Water ingress through glands, junction boxes, or damaged sheath causes corrosion, insulation deterioration, or repeated electrical faults
  • Excessive bending, unsupported runs, or vibration damages conductors or shielding and can produce intermittent open circuits
  • Fire or thermal exposure beyond the cable's design condition can degrade insulation and lead to loss of continuity or short circuit
Service: Inspect accessible routes, support spacing, bend condition, segregation, glands, penetrations, fire stops, sheath damage, terminations, earthing or shielding, and signs of overheating. Insulation and continuity testing must suit the circuit and connected equipment; refer to approved cable data for exact test voltages and installation limits.
Spare Parts: Keep approved glands, lugs, ferrules, terminals, junction-box sealing items, repair sleeves where permitted, and suitable replacement cable of the exact approved type and rating.
Use Cases: Used throughout all vessel types for power distribution, control, instrumentation, communications, safety systems, and emergency circuits.
S7-I 8Px1.5mm2 300/500V unverified
Cross Section (mm²)
1.5
Voltage Class
300/500V
Cores
8
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation damage from heat, abrasion, oil, chemicals, or mechanical impact causes earth faults, leakage current, or intermittent circuits
  • Loose or corroded terminations increase contact resistance and appear as heating, voltage drop, or unstable signals
  • Water ingress through glands, junction boxes, or damaged sheath causes corrosion, insulation deterioration, or repeated electrical faults
  • Excessive bending, unsupported runs, or vibration damages conductors or shielding and can produce intermittent open circuits
  • Fire or thermal exposure beyond the cable's design condition can degrade insulation and lead to loss of continuity or short circuit
Service: Inspect accessible routes, support spacing, bend condition, segregation, glands, penetrations, fire stops, sheath damage, terminations, earthing or shielding, and signs of overheating. Insulation and continuity testing must suit the circuit and connected equipment; refer to approved cable data for exact test voltages and installation limits.
Spare Parts: Keep approved glands, lugs, ferrules, terminals, junction-box sealing items, repair sleeves where permitted, and suitable replacement cable of the exact approved type and rating.
Use Cases: Used throughout all vessel types for power distribution, control, instrumentation, communications, safety systems, and emergency circuits.
S7-I 12Px1.5mm2 300/500V unverified
Cross Section (mm²)
1.5
Voltage Class
300/500V
Cores
12
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation damage from heat, abrasion, oil, chemicals, or mechanical impact causes earth faults, leakage current, or intermittent circuits
  • Loose or corroded terminations increase contact resistance and appear as heating, voltage drop, or unstable signals
  • Water ingress through glands, junction boxes, or damaged sheath causes corrosion, insulation deterioration, or repeated electrical faults
  • Excessive bending, unsupported runs, or vibration damages conductors or shielding and can produce intermittent open circuits
  • Fire or thermal exposure beyond the cable's design condition can degrade insulation and lead to loss of continuity or short circuit
Service: Inspect accessible routes, support spacing, bend condition, segregation, glands, penetrations, fire stops, sheath damage, terminations, earthing or shielding, and signs of overheating. Insulation and continuity testing must suit the circuit and connected equipment; refer to approved cable data for exact test voltages and installation limits.
Spare Parts: Keep approved glands, lugs, ferrules, terminals, junction-box sealing items, repair sleeves where permitted, and suitable replacement cable of the exact approved type and rating.
Use Cases: Used throughout all vessel types for power distribution, control, instrumentation, communications, safety systems, and emergency circuits.
S7-I 2Px2.5mm2 300/500V unverified
Cross Section (mm²)
2.5
Voltage Class
300/500V
Cores
2
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation damage from heat, abrasion, oil, chemicals, or mechanical impact causes earth faults, leakage current, or intermittent circuits
  • Loose or corroded terminations increase contact resistance and appear as heating, voltage drop, or unstable signals
  • Water ingress through glands, junction boxes, or damaged sheath causes corrosion, insulation deterioration, or repeated electrical faults
  • Excessive bending, unsupported runs, or vibration damages conductors or shielding and can produce intermittent open circuits
  • Fire or thermal exposure beyond the cable's design condition can degrade insulation and lead to loss of continuity or short circuit
Service: Inspect accessible routes, support spacing, bend condition, segregation, glands, penetrations, fire stops, sheath damage, terminations, earthing or shielding, and signs of overheating. Insulation and continuity testing must suit the circuit and connected equipment; refer to approved cable data for exact test voltages and installation limits.
Spare Parts: Keep approved glands, lugs, ferrules, terminals, junction-box sealing items, repair sleeves where permitted, and suitable replacement cable of the exact approved type and rating.
Use Cases: Used throughout all vessel types for power distribution, control, instrumentation, communications, safety systems, and emergency circuits.
S7-I 4Px2.5mm2 300/500V unverified
Cross Section (mm²)
2.5
Voltage Class
300/500V
Cores
4
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation damage from heat, abrasion, oil, chemicals, or mechanical impact causes earth faults, leakage current, or intermittent circuits
  • Loose or corroded terminations increase contact resistance and appear as heating, voltage drop, or unstable signals
  • Water ingress through glands, junction boxes, or damaged sheath causes corrosion, insulation deterioration, or repeated electrical faults
  • Excessive bending, unsupported runs, or vibration damages conductors or shielding and can produce intermittent open circuits
  • Fire or thermal exposure beyond the cable's design condition can degrade insulation and lead to loss of continuity or short circuit
Service: Inspect accessible routes, support spacing, bend condition, segregation, glands, penetrations, fire stops, sheath damage, terminations, earthing or shielding, and signs of overheating. Insulation and continuity testing must suit the circuit and connected equipment; refer to approved cable data for exact test voltages and installation limits.
Spare Parts: Keep approved glands, lugs, ferrules, terminals, junction-box sealing items, repair sleeves where permitted, and suitable replacement cable of the exact approved type and rating.
Use Cases: Used throughout all vessel types for power distribution, control, instrumentation, communications, safety systems, and emergency circuits.
S7-I 6Px2.5mm2 300/500V unverified
Cross Section (mm²)
2.5
Voltage Class
300/500V
Cores
6
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation damage from heat, abrasion, oil, chemicals, or mechanical impact causes earth faults, leakage current, or intermittent circuits
  • Loose or corroded terminations increase contact resistance and appear as heating, voltage drop, or unstable signals
  • Water ingress through glands, junction boxes, or damaged sheath causes corrosion, insulation deterioration, or repeated electrical faults
  • Excessive bending, unsupported runs, or vibration damages conductors or shielding and can produce intermittent open circuits
  • Fire or thermal exposure beyond the cable's design condition can degrade insulation and lead to loss of continuity or short circuit
Service: Inspect accessible routes, support spacing, bend condition, segregation, glands, penetrations, fire stops, sheath damage, terminations, earthing or shielding, and signs of overheating. Insulation and continuity testing must suit the circuit and connected equipment; refer to approved cable data for exact test voltages and installation limits.
Spare Parts: Keep approved glands, lugs, ferrules, terminals, junction-box sealing items, repair sleeves where permitted, and suitable replacement cable of the exact approved type and rating.
Use Cases: Used throughout all vessel types for power distribution, control, instrumentation, communications, safety systems, and emergency circuits.
S7-I 8Px2.5mm2 300/500V unverified
Cross Section (mm²)
2.5
Voltage Class
300/500V
Cores
8
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation damage from heat, abrasion, oil, chemicals, or mechanical impact causes earth faults, leakage current, or intermittent circuits
  • Loose or corroded terminations increase contact resistance and appear as heating, voltage drop, or unstable signals
  • Water ingress through glands, junction boxes, or damaged sheath causes corrosion, insulation deterioration, or repeated electrical faults
  • Excessive bending, unsupported runs, or vibration damages conductors or shielding and can produce intermittent open circuits
  • Fire or thermal exposure beyond the cable's design condition can degrade insulation and lead to loss of continuity or short circuit
Service: Inspect accessible routes, support spacing, bend condition, segregation, glands, penetrations, fire stops, sheath damage, terminations, earthing or shielding, and signs of overheating. Insulation and continuity testing must suit the circuit and connected equipment; refer to approved cable data for exact test voltages and installation limits.
Spare Parts: Keep approved glands, lugs, ferrules, terminals, junction-box sealing items, repair sleeves where permitted, and suitable replacement cable of the exact approved type and rating.
Use Cases: Used throughout all vessel types for power distribution, control, instrumentation, communications, safety systems, and emergency circuits.
S7-I 12Px2.5mm2 300/500V unverified
Cross Section (mm²)
2.5
Voltage Class
300/500V
Cores
12
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation damage from heat, abrasion, oil, chemicals, or mechanical impact causes earth faults, leakage current, or intermittent circuits
  • Loose or corroded terminations increase contact resistance and appear as heating, voltage drop, or unstable signals
  • Water ingress through glands, junction boxes, or damaged sheath causes corrosion, insulation deterioration, or repeated electrical faults
  • Excessive bending, unsupported runs, or vibration damages conductors or shielding and can produce intermittent open circuits
  • Fire or thermal exposure beyond the cable's design condition can degrade insulation and lead to loss of continuity or short circuit
Service: Inspect accessible routes, support spacing, bend condition, segregation, glands, penetrations, fire stops, sheath damage, terminations, earthing or shielding, and signs of overheating. Insulation and continuity testing must suit the circuit and connected equipment; refer to approved cable data for exact test voltages and installation limits.
Spare Parts: Keep approved glands, lugs, ferrules, terminals, junction-box sealing items, repair sleeves where permitted, and suitable replacement cable of the exact approved type and rating.
Use Cases: Used throughout all vessel types for power distribution, control, instrumentation, communications, safety systems, and emergency circuits.

TMC Marine

10
FX-I 2Px1.5mm2 300/500V unverified
Cross Section (mm²)
1.5
Voltage Class
300/500V
Cores
2
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation deterioration from heat, oil, chemicals, UV exposure or ageing, typically indicated by low insulation resistance, earth-fault alarms or visible cracking
  • Mechanical damage from chafing, crushing or poor support, typically indicated by exposed armour or conductors, intermittent faults or short circuits
  • Water ingress through damaged glands or transits, typically indicated by corrosion, insulation alarms or intermittent operation
  • Loose or overheated terminations from poor tightening or excessive current, typically indicated by discoloration, hot spots, voltage drop or burnt insulation
  • Shielding, armour or bonding discontinuity from corrosion or incorrect termination, typically indicated by electrical noise, unreliable signals or failed protective bonding checks
Service: Inspect cable routes, supports, bending, glands, armour or screens, fire-stop transits and terminations; perform insulation, continuity or functional testing as appropriate and use manufacturer/class documentation for exact acceptance values.
Spare Parts: Keep approved cable glands, lugs, ferrules, heat-shrink, transit inserts or sealing modules and suitable lengths of critical cable types used on board.
Use Cases: Used in all vessel electrical, automation, propulsion, communication and safety systems, with the exact cable type selected for voltage, fire performance and signal duty. This entry applies specifically to the Instrumentation Cable variant identified as TMC Marine FX-I 2Px1.5mm2 300/500V.
FX-I 4Px1.5mm2 300/500V unverified
Cross Section (mm²)
1.5
Voltage Class
300/500V
Cores
4
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation deterioration from heat, oil, chemicals, UV exposure or ageing, typically indicated by low insulation resistance, earth-fault alarms or visible cracking
  • Mechanical damage from chafing, crushing or poor support, typically indicated by exposed armour or conductors, intermittent faults or short circuits
  • Water ingress through damaged glands or transits, typically indicated by corrosion, insulation alarms or intermittent operation
  • Loose or overheated terminations from poor tightening or excessive current, typically indicated by discoloration, hot spots, voltage drop or burnt insulation
  • Shielding, armour or bonding discontinuity from corrosion or incorrect termination, typically indicated by electrical noise, unreliable signals or failed protective bonding checks
Service: Inspect cable routes, supports, bending, glands, armour or screens, fire-stop transits and terminations; perform insulation, continuity or functional testing as appropriate and use manufacturer/class documentation for exact acceptance values.
Spare Parts: Keep approved cable glands, lugs, ferrules, heat-shrink, transit inserts or sealing modules and suitable lengths of critical cable types used on board.
Use Cases: Used in all vessel electrical, automation, propulsion, communication and safety systems, with the exact cable type selected for voltage, fire performance and signal duty. This entry applies specifically to the Instrumentation Cable variant identified as TMC Marine FX-I 4Px1.5mm2 300/500V.
FX-I 6Px1.5mm2 300/500V unverified
Cross Section (mm²)
1.5
Voltage Class
300/500V
Cores
6
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation deterioration from heat, oil, chemicals, UV exposure or ageing, typically indicated by low insulation resistance, earth-fault alarms or visible cracking
  • Mechanical damage from chafing, crushing or poor support, typically indicated by exposed armour or conductors, intermittent faults or short circuits
  • Water ingress through damaged glands or transits, typically indicated by corrosion, insulation alarms or intermittent operation
  • Loose or overheated terminations from poor tightening or excessive current, typically indicated by discoloration, hot spots, voltage drop or burnt insulation
  • Shielding, armour or bonding discontinuity from corrosion or incorrect termination, typically indicated by electrical noise, unreliable signals or failed protective bonding checks
Service: Inspect cable routes, supports, bending, glands, armour or screens, fire-stop transits and terminations; perform insulation, continuity or functional testing as appropriate and use manufacturer/class documentation for exact acceptance values.
Spare Parts: Keep approved cable glands, lugs, ferrules, heat-shrink, transit inserts or sealing modules and suitable lengths of critical cable types used on board.
Use Cases: Used in all vessel electrical, automation, propulsion, communication and safety systems, with the exact cable type selected for voltage, fire performance and signal duty. This entry applies specifically to the Instrumentation Cable variant identified as TMC Marine FX-I 6Px1.5mm2 300/500V.
FX-I 8Px1.5mm2 300/500V unverified
Cross Section (mm²)
1.5
Voltage Class
300/500V
Cores
8
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation deterioration from heat, oil, chemicals, UV exposure or ageing, typically indicated by low insulation resistance, earth-fault alarms or visible cracking
  • Mechanical damage from chafing, crushing or poor support, typically indicated by exposed armour or conductors, intermittent faults or short circuits
  • Water ingress through damaged glands or transits, typically indicated by corrosion, insulation alarms or intermittent operation
  • Loose or overheated terminations from poor tightening or excessive current, typically indicated by discoloration, hot spots, voltage drop or burnt insulation
  • Shielding, armour or bonding discontinuity from corrosion or incorrect termination, typically indicated by electrical noise, unreliable signals or failed protective bonding checks
Service: Inspect cable routes, supports, bending, glands, armour or screens, fire-stop transits and terminations; perform insulation, continuity or functional testing as appropriate and use manufacturer/class documentation for exact acceptance values.
Spare Parts: Keep approved cable glands, lugs, ferrules, heat-shrink, transit inserts or sealing modules and suitable lengths of critical cable types used on board.
Use Cases: Used in all vessel electrical, automation, propulsion, communication and safety systems, with the exact cable type selected for voltage, fire performance and signal duty. This entry applies specifically to the Instrumentation Cable variant identified as TMC Marine FX-I 8Px1.5mm2 300/500V.
FX-I 12Px1.5mm2 300/500V unverified
Cross Section (mm²)
1.5
Voltage Class
300/500V
Cores
12
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation deterioration from heat, oil, chemicals, UV exposure or ageing, typically indicated by low insulation resistance, earth-fault alarms or visible cracking
  • Mechanical damage from chafing, crushing or poor support, typically indicated by exposed armour or conductors, intermittent faults or short circuits
  • Water ingress through damaged glands or transits, typically indicated by corrosion, insulation alarms or intermittent operation
  • Loose or overheated terminations from poor tightening or excessive current, typically indicated by discoloration, hot spots, voltage drop or burnt insulation
  • Shielding, armour or bonding discontinuity from corrosion or incorrect termination, typically indicated by electrical noise, unreliable signals or failed protective bonding checks
Service: Inspect cable routes, supports, bending, glands, armour or screens, fire-stop transits and terminations; perform insulation, continuity or functional testing as appropriate and use manufacturer/class documentation for exact acceptance values.
Spare Parts: Keep approved cable glands, lugs, ferrules, heat-shrink, transit inserts or sealing modules and suitable lengths of critical cable types used on board.
Use Cases: Used in all vessel electrical, automation, propulsion, communication and safety systems, with the exact cable type selected for voltage, fire performance and signal duty. This entry applies specifically to the Instrumentation Cable variant identified as TMC Marine FX-I 12Px1.5mm2 300/500V.
FX-I 2Px2.5mm2 300/500V unverified
Cross Section (mm²)
2.5
Voltage Class
300/500V
Cores
2
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation deterioration from heat, oil, chemicals, UV exposure or ageing, typically indicated by low insulation resistance, earth-fault alarms or visible cracking
  • Mechanical damage from chafing, crushing or poor support, typically indicated by exposed armour or conductors, intermittent faults or short circuits
  • Water ingress through damaged glands or transits, typically indicated by corrosion, insulation alarms or intermittent operation
  • Loose or overheated terminations from poor tightening or excessive current, typically indicated by discoloration, hot spots, voltage drop or burnt insulation
  • Shielding, armour or bonding discontinuity from corrosion or incorrect termination, typically indicated by electrical noise, unreliable signals or failed protective bonding checks
Service: Inspect cable routes, supports, bending, glands, armour or screens, fire-stop transits and terminations; perform insulation, continuity or functional testing as appropriate and use manufacturer/class documentation for exact acceptance values.
Spare Parts: Keep approved cable glands, lugs, ferrules, heat-shrink, transit inserts or sealing modules and suitable lengths of critical cable types used on board.
Use Cases: Used in all vessel electrical, automation, propulsion, communication and safety systems, with the exact cable type selected for voltage, fire performance and signal duty. This entry applies specifically to the Instrumentation Cable variant identified as TMC Marine FX-I 2Px2.5mm2 300/500V.
FX-I 4Px2.5mm2 300/500V unverified
Cross Section (mm²)
2.5
Voltage Class
300/500V
Cores
4
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation deterioration from heat, oil, chemicals, UV exposure or ageing, typically indicated by low insulation resistance, earth-fault alarms or visible cracking
  • Mechanical damage from chafing, crushing or poor support, typically indicated by exposed armour or conductors, intermittent faults or short circuits
  • Water ingress through damaged glands or transits, typically indicated by corrosion, insulation alarms or intermittent operation
  • Loose or overheated terminations from poor tightening or excessive current, typically indicated by discoloration, hot spots, voltage drop or burnt insulation
  • Shielding, armour or bonding discontinuity from corrosion or incorrect termination, typically indicated by electrical noise, unreliable signals or failed protective bonding checks
Service: Inspect cable routes, supports, bending, glands, armour or screens, fire-stop transits and terminations; perform insulation, continuity or functional testing as appropriate and use manufacturer/class documentation for exact acceptance values.
Spare Parts: Keep approved cable glands, lugs, ferrules, heat-shrink, transit inserts or sealing modules and suitable lengths of critical cable types used on board.
Use Cases: Used in all vessel electrical, automation, propulsion, communication and safety systems, with the exact cable type selected for voltage, fire performance and signal duty. This entry applies specifically to the Instrumentation Cable variant identified as TMC Marine FX-I 4Px2.5mm2 300/500V.
FX-I 6Px2.5mm2 300/500V unverified
Cross Section (mm²)
2.5
Voltage Class
300/500V
Cores
6
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation deterioration from heat, oil, chemicals, UV exposure or ageing, typically indicated by low insulation resistance, earth-fault alarms or visible cracking
  • Mechanical damage from chafing, crushing or poor support, typically indicated by exposed armour or conductors, intermittent faults or short circuits
  • Water ingress through damaged glands or transits, typically indicated by corrosion, insulation alarms or intermittent operation
  • Loose or overheated terminations from poor tightening or excessive current, typically indicated by discoloration, hot spots, voltage drop or burnt insulation
  • Shielding, armour or bonding discontinuity from corrosion or incorrect termination, typically indicated by electrical noise, unreliable signals or failed protective bonding checks
Service: Inspect cable routes, supports, bending, glands, armour or screens, fire-stop transits and terminations; perform insulation, continuity or functional testing as appropriate and use manufacturer/class documentation for exact acceptance values.
Spare Parts: Keep approved cable glands, lugs, ferrules, heat-shrink, transit inserts or sealing modules and suitable lengths of critical cable types used on board.
Use Cases: Used in all vessel electrical, automation, propulsion, communication and safety systems, with the exact cable type selected for voltage, fire performance and signal duty. This entry applies specifically to the Instrumentation Cable variant identified as TMC Marine FX-I 6Px2.5mm2 300/500V.
FX-I 8Px2.5mm2 300/500V unverified
Cross Section (mm²)
2.5
Voltage Class
300/500V
Cores
8
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation deterioration from heat, oil, chemicals, UV exposure or ageing, typically indicated by low insulation resistance, earth-fault alarms or visible cracking
  • Mechanical damage from chafing, crushing or poor support, typically indicated by exposed armour or conductors, intermittent faults or short circuits
  • Water ingress through damaged glands or transits, typically indicated by corrosion, insulation alarms or intermittent operation
  • Loose or overheated terminations from poor tightening or excessive current, typically indicated by discoloration, hot spots, voltage drop or burnt insulation
  • Shielding, armour or bonding discontinuity from corrosion or incorrect termination, typically indicated by electrical noise, unreliable signals or failed protective bonding checks
Service: Inspect cable routes, supports, bending, glands, armour or screens, fire-stop transits and terminations; perform insulation, continuity or functional testing as appropriate and use manufacturer/class documentation for exact acceptance values.
Spare Parts: Keep approved cable glands, lugs, ferrules, heat-shrink, transit inserts or sealing modules and suitable lengths of critical cable types used on board.
Use Cases: Used in all vessel electrical, automation, propulsion, communication and safety systems, with the exact cable type selected for voltage, fire performance and signal duty. This entry applies specifically to the Instrumentation Cable variant identified as TMC Marine FX-I 8Px2.5mm2 300/500V.
FX-I 12Px2.5mm2 300/500V unverified
Cross Section (mm²)
2.5
Voltage Class
300/500V
Cores
12
Material
Cu
Insulation
XLPE
Fire Rating
IEC60332-1
Halogen-Free
nein
Common Failures & Inspection Points
  • Insulation deterioration from heat, oil, chemicals, UV exposure or ageing, typically indicated by low insulation resistance, earth-fault alarms or visible cracking
  • Mechanical damage from chafing, crushing or poor support, typically indicated by exposed armour or conductors, intermittent faults or short circuits
  • Water ingress through damaged glands or transits, typically indicated by corrosion, insulation alarms or intermittent operation
  • Loose or overheated terminations from poor tightening or excessive current, typically indicated by discoloration, hot spots, voltage drop or burnt insulation
  • Shielding, armour or bonding discontinuity from corrosion or incorrect termination, typically indicated by electrical noise, unreliable signals or failed protective bonding checks
Service: Inspect cable routes, supports, bending, glands, armour or screens, fire-stop transits and terminations; perform insulation, continuity or functional testing as appropriate and use manufacturer/class documentation for exact acceptance values.
Spare Parts: Keep approved cable glands, lugs, ferrules, heat-shrink, transit inserts or sealing modules and suitable lengths of critical cable types used on board.
Use Cases: Used in all vessel electrical, automation, propulsion, communication and safety systems, with the exact cable type selected for voltage, fire performance and signal duty. This entry applies specifically to the Instrumentation Cable variant identified as TMC Marine FX-I 12Px2.5mm2 300/500V.

SAMI

5
High temperature instrumentation cables, unarmored
Model Number
TAE00003JY
High temperature instrumentation and thermocouple cables, armored.
Model Number
TAE00003JX
High temperature instrumentation and thermocouple cables, unarmoured PFA
Model Number
TAE00003JV
High temperature instrumentation cables, armored
Model Number
TAE00003JZ
High temperature thermocouple cable, unarmored, PTFE - Polyimide
Model Number
TAE00003JW

Habia Cable

2
DMFRO 250V
Model Number
TAE00004S4
DMFRO 0,6/1KV
Model Number
TAE00002VZ

Habia Cable China

2
DMFRO 250V
Model Number
TAE00004KX
DMFRO
Model Number
TAE00002CV

BizLink Special Cables Germany

1
BizLink Special Cables Germany GmbH L-2X(ST)C & 2X CH
L-2X(ST)C & 2X CH
Model Number
TAE00001JH

Kukdong Electric Wire

1
HF-FTFT, HF-FTFT(C), HF-FTFT(I), HF-FTFT(I/C)
Model Number
TAE00002J0