Instrumentation Cable · Cable & Wiring
Studer Cables BETAflam-I 4Px2.5mm2 300/500V is identified in the source list as a instrumentation cable. It is routed through cable trays, penetrations, machinery spaces, accommodation or deck areas between the electrical or electronic equipment it connects. Its purpose is to transmit electrical power, control signals, instrumentation data or communications while maintaining the insulation, screening and fire-performance requirements of the installation. The source record provides the existing record note '2.5 mm² cross-section'. Conductor material, insulation, sheath, armor or screen, voltage class and fire properties depend on the exact cable type and approved installation. The exact cable designation distinguishes voltage rating, conductor construction and fire or communication performance from neighboring cable types; refer to the manufacturer documentation for the exact figure.
Every value below comes from the manufacturer datasheet or class-society record on file for this model.
Other models of the same equipment type, Studer Cables first.
What our service work and the manufacturer documentation say about keeping this model running.
Inspect visible cable runs, supports, glands, terminations, penetrations and fire stops for damage, corrosion, overheating and unauthorized modifications. Maintain bend radius and support without imposing strain on equipment terminals. Check insulation resistance or continuity using procedures suitable for connected equipment and isolate sensitive electronics when required. Inspect cable glands and deck penetrations for water ingress and verify screens and armor are terminated according to the approved design. Replace damaged cable with an approved equivalent rather than patching critical insulation casually. Refer to the manufacturer documentation for the exact figure for conductor ratings, bend radius and test limits.
Keep suitable lengths of approved cable for critical services together with glands, lugs, ferrules, heat-shrink, identification materials and certified fire-stop products appropriate to the installation. Communication and fire-resistant cable replacements must preserve required screening and approval. Verify voltage, conductor size and material before use.
Free of charge — we forward your request to qualified suppliers for Studer Cables equipment from our network of over 114,000 maritime companies.
Tell us what you need for this Studer Cables BETAflam-I 4Px2.5mm2 300/500V — a part, a service call, a second opinion. Are you Studer Cables? Claim this brand page.
Service engineer? Write the day report for this BETAflam-I 4Px2.5mm2 300/500V in OceanSphere Work — photos, hours and parts, as a PDF for the owner. Try it free for 14 days →
Yes. Specifications, documents and service notes for this model are readable without an account. An account adds saved searches and requests, nothing is taken away.
Yes. Tell us the manufacturer, the model and what you need — our desk asks the right suppliers from a network of over 114,000 companies and comes back with a quote or a sourcing plan.
Send us the nameplate or the correct value. We check it against the manufacturer datasheet or class-society record and update the page.