17 manufacturers · 19 models
KSB Seil Co., Ltd.
2- Area: Calibration Certificate Status and ValidityCheck: Verify that current valid ODME calibration certificate is onboard, checked within 12 months (annual verification requirement), and renewed every 5 years. Certificate must be from authorized service agent per MEPC.108(49). Check for broken seals indicating unauthorized intervention.
- Area: Oil Content Meter Accuracy and Cell FoulingCheck: Inspect oil content meter for optical cell cleanliness and condition. Test system accuracy with known standard (e.g., clean water baseline and 10 ppm calibration standard). Check for automatic window flushing system functionality. Accuracy must remain within +/- 10 ppm or +/- 10% (whichever greater) per MEPC.108(49) section 6.2.2.
- Area: Flow Meter and Pitot Tube IntegrityCheck: Verify flow meter operational status and Pitot tube positioning in discharge line. Check pressure differential transmitter readings for reasonableness. Confirm sample flow rate is within design parameters (typically 4-5 L/min or 240-900 L/hour depending on model). Test discharge calculation (oil content x flow rate x time).
- Area: Data Recording and Log Records (3-year retention)Check: Review ODME discharge logs for last 3 years: verify oil content readings, discharge dates/times, vessel position (GPS), total quantities. Check for continuity gaps or unexplained system downtime. Confirm records stored in approved format (paper or electronic per MARPOL Annex I). Inspect for evidence of unauthorized modifications or record tampering.
- Area: System Failure and Overboard Valve Control FunctionCheck: Test automatic control valve solenoid operation: activate system simulation mode (if available) to verify that discharge valve closes when oil concentration exceeds 15 ppm threshold. Confirm mechanical interlocks and electrical failsafe mechanisms. Check pump motor operation and pressure relief settings. Verify failure notification procedures (engine room alarm, bridge alert, maintenance log entry).
Typ-universelle Inspektionspunkte fuer ODME System (verifiziert, 2026-06).
- Area: Calibration Certificate Status and ValidityCheck: Verify that current valid ODME calibration certificate is onboard, checked within 12 months (annual verification requirement), and renewed every 5 years. Certificate must be from authorized service agent per MEPC.108(49). Check for broken seals indicating unauthorized intervention.
- Area: Oil Content Meter Accuracy and Cell FoulingCheck: Inspect oil content meter for optical cell cleanliness and condition. Test system accuracy with known standard (e.g., clean water baseline and 10 ppm calibration standard). Check for automatic window flushing system functionality. Accuracy must remain within +/- 10 ppm or +/- 10% (whichever greater) per MEPC.108(49) section 6.2.2.
- Area: Flow Meter and Pitot Tube IntegrityCheck: Verify flow meter operational status and Pitot tube positioning in discharge line. Check pressure differential transmitter readings for reasonableness. Confirm sample flow rate is within design parameters (typically 4-5 L/min or 240-900 L/hour depending on model). Test discharge calculation (oil content x flow rate x time).
- Area: Data Recording and Log Records (3-year retention)Check: Review ODME discharge logs for last 3 years: verify oil content readings, discharge dates/times, vessel position (GPS), total quantities. Check for continuity gaps or unexplained system downtime. Confirm records stored in approved format (paper or electronic per MARPOL Annex I). Inspect for evidence of unauthorized modifications or record tampering.
- Area: System Failure and Overboard Valve Control FunctionCheck: Test automatic control valve solenoid operation: activate system simulation mode (if available) to verify that discharge valve closes when oil concentration exceeds 15 ppm threshold. Confirm mechanical interlocks and electrical failsafe mechanisms. Check pump motor operation and pressure relief settings. Verify failure notification procedures (engine room alarm, bridge alert, maintenance log entry).
Typ-universelle Inspektionspunkte fuer ODME System (verifiziert, 2026-06).
Rivertrace Engineering
2- Area: Calibration Certificate Status and ValidityCheck: Verify that current valid ODME calibration certificate is onboard, checked within 12 months (annual verification requirement), and renewed every 5 years. Certificate must be from authorized service agent per MEPC.108(49). Check for broken seals indicating unauthorized intervention.
- Area: Oil Content Meter Accuracy and Cell FoulingCheck: Inspect oil content meter for optical cell cleanliness and condition. Test system accuracy with known standard (e.g., clean water baseline and 10 ppm calibration standard). Check for automatic window flushing system functionality. Accuracy must remain within +/- 10 ppm or +/- 10% (whichever greater) per MEPC.108(49) section 6.2.2.
- Area: Flow Meter and Pitot Tube IntegrityCheck: Verify flow meter operational status and Pitot tube positioning in discharge line. Check pressure differential transmitter readings for reasonableness. Confirm sample flow rate is within design parameters (typically 4-5 L/min or 240-900 L/hour depending on model). Test discharge calculation (oil content x flow rate x time).
- Area: Data Recording and Log Records (3-year retention)Check: Review ODME discharge logs for last 3 years: verify oil content readings, discharge dates/times, vessel position (GPS), total quantities. Check for continuity gaps or unexplained system downtime. Confirm records stored in approved format (paper or electronic per MARPOL Annex I). Inspect for evidence of unauthorized modifications or record tampering.
- Area: System Failure and Overboard Valve Control FunctionCheck: Test automatic control valve solenoid operation: activate system simulation mode (if available) to verify that discharge valve closes when oil concentration exceeds 15 ppm threshold. Confirm mechanical interlocks and electrical failsafe mechanisms. Check pump motor operation and pressure relief settings. Verify failure notification procedures (engine room alarm, bridge alert, maintenance log entry).
Typ-universelle Inspektionspunkte fuer ODME System (verifiziert, 2026-06).
- Area: Calibration Certificate Status and ValidityCheck: Verify that current valid ODME calibration certificate is onboard, checked within 12 months (annual verification requirement), and renewed every 5 years. Certificate must be from authorized service agent per MEPC.108(49). Check for broken seals indicating unauthorized intervention.
- Area: Oil Content Meter Accuracy and Cell FoulingCheck: Inspect oil content meter for optical cell cleanliness and condition. Test system accuracy with known standard (e.g., clean water baseline and 10 ppm calibration standard). Check for automatic window flushing system functionality. Accuracy must remain within +/- 10 ppm or +/- 10% (whichever greater) per MEPC.108(49) section 6.2.2.
- Area: Flow Meter and Pitot Tube IntegrityCheck: Verify flow meter operational status and Pitot tube positioning in discharge line. Check pressure differential transmitter readings for reasonableness. Confirm sample flow rate is within design parameters (typically 4-5 L/min or 240-900 L/hour depending on model). Test discharge calculation (oil content x flow rate x time).
- Area: Data Recording and Log Records (3-year retention)Check: Review ODME discharge logs for last 3 years: verify oil content readings, discharge dates/times, vessel position (GPS), total quantities. Check for continuity gaps or unexplained system downtime. Confirm records stored in approved format (paper or electronic per MARPOL Annex I). Inspect for evidence of unauthorized modifications or record tampering.
- Area: System Failure and Overboard Valve Control FunctionCheck: Test automatic control valve solenoid operation: activate system simulation mode (if available) to verify that discharge valve closes when oil concentration exceeds 15 ppm threshold. Confirm mechanical interlocks and electrical failsafe mechanisms. Check pump motor operation and pressure relief settings. Verify failure notification procedures (engine room alarm, bridge alert, maintenance log entry).
Typ-universelle Inspektionspunkte fuer ODME System (verifiziert, 2026-06).
AJ Marine Solution (Bangladesh - distributor)
1- Area: Calibration Certificate Status and ValidityCheck: Verify that current valid ODME calibration certificate is onboard, checked within 12 months (annual verification requirement), and renewed every 5 years. Certificate must be from authorized service agent per MEPC.108(49). Check for broken seals indicating unauthorized intervention.
- Area: Oil Content Meter Accuracy and Cell FoulingCheck: Inspect oil content meter for optical cell cleanliness and condition. Test system accuracy with known standard (e.g., clean water baseline and 10 ppm calibration standard). Check for automatic window flushing system functionality. Accuracy must remain within +/- 10 ppm or +/- 10% (whichever greater) per MEPC.108(49) section 6.2.2.
- Area: Flow Meter and Pitot Tube IntegrityCheck: Verify flow meter operational status and Pitot tube positioning in discharge line. Check pressure differential transmitter readings for reasonableness. Confirm sample flow rate is within design parameters (typically 4-5 L/min or 240-900 L/hour depending on model). Test discharge calculation (oil content x flow rate x time).
- Area: Data Recording and Log Records (3-year retention)Check: Review ODME discharge logs for last 3 years: verify oil content readings, discharge dates/times, vessel position (GPS), total quantities. Check for continuity gaps or unexplained system downtime. Confirm records stored in approved format (paper or electronic per MARPOL Annex I). Inspect for evidence of unauthorized modifications or record tampering.
- Area: System Failure and Overboard Valve Control FunctionCheck: Test automatic control valve solenoid operation: activate system simulation mode (if available) to verify that discharge valve closes when oil concentration exceeds 15 ppm threshold. Confirm mechanical interlocks and electrical failsafe mechanisms. Check pump motor operation and pressure relief settings. Verify failure notification procedures (engine room alarm, bridge alert, maintenance log entry).
Typ-universelle Inspektionspunkte fuer ODME System (verifiziert, 2026-06).
Brannstrom Sweden AB
1- Area: Calibration Certificate Status and ValidityCheck: Verify that current valid ODME calibration certificate is onboard, checked within 12 months (annual verification requirement), and renewed every 5 years. Certificate must be from authorized service agent per MEPC.108(49). Check for broken seals indicating unauthorized intervention.
- Area: Oil Content Meter Accuracy and Cell FoulingCheck: Inspect oil content meter for optical cell cleanliness and condition. Test system accuracy with known standard (e.g., clean water baseline and 10 ppm calibration standard). Check for automatic window flushing system functionality. Accuracy must remain within +/- 10 ppm or +/- 10% (whichever greater) per MEPC.108(49) section 6.2.2.
- Area: Flow Meter and Pitot Tube IntegrityCheck: Verify flow meter operational status and Pitot tube positioning in discharge line. Check pressure differential transmitter readings for reasonableness. Confirm sample flow rate is within design parameters (typically 4-5 L/min or 240-900 L/hour depending on model). Test discharge calculation (oil content x flow rate x time).
- Area: Data Recording and Log Records (3-year retention)Check: Review ODME discharge logs for last 3 years: verify oil content readings, discharge dates/times, vessel position (GPS), total quantities. Check for continuity gaps or unexplained system downtime. Confirm records stored in approved format (paper or electronic per MARPOL Annex I). Inspect for evidence of unauthorized modifications or record tampering.
- Area: System Failure and Overboard Valve Control FunctionCheck: Test automatic control valve solenoid operation: activate system simulation mode (if available) to verify that discharge valve closes when oil concentration exceeds 15 ppm threshold. Confirm mechanical interlocks and electrical failsafe mechanisms. Check pump motor operation and pressure relief settings. Verify failure notification procedures (engine room alarm, bridge alert, maintenance log entry).
Typ-universelle Inspektionspunkte fuer ODME System (verifiziert, 2026-06).
Deckma
1- Sensor contamination
- Pump diaphragm failure
- Recording unit malfunction
Deyuan Marine (China)
1- Area: Calibration Certificate Status and ValidityCheck: Verify that current valid ODME calibration certificate is onboard, checked within 12 months (annual verification requirement), and renewed every 5 years. Certificate must be from authorized service agent per MEPC.108(49). Check for broken seals indicating unauthorized intervention.
- Area: Oil Content Meter Accuracy and Cell FoulingCheck: Inspect oil content meter for optical cell cleanliness and condition. Test system accuracy with known standard (e.g., clean water baseline and 10 ppm calibration standard). Check for automatic window flushing system functionality. Accuracy must remain within +/- 10 ppm or +/- 10% (whichever greater) per MEPC.108(49) section 6.2.2.
- Area: Flow Meter and Pitot Tube IntegrityCheck: Verify flow meter operational status and Pitot tube positioning in discharge line. Check pressure differential transmitter readings for reasonableness. Confirm sample flow rate is within design parameters (typically 4-5 L/min or 240-900 L/hour depending on model). Test discharge calculation (oil content x flow rate x time).
- Area: Data Recording and Log Records (3-year retention)Check: Review ODME discharge logs for last 3 years: verify oil content readings, discharge dates/times, vessel position (GPS), total quantities. Check for continuity gaps or unexplained system downtime. Confirm records stored in approved format (paper or electronic per MARPOL Annex I). Inspect for evidence of unauthorized modifications or record tampering.
- Area: System Failure and Overboard Valve Control FunctionCheck: Test automatic control valve solenoid operation: activate system simulation mode (if available) to verify that discharge valve closes when oil concentration exceeds 15 ppm threshold. Confirm mechanical interlocks and electrical failsafe mechanisms. Check pump motor operation and pressure relief settings. Verify failure notification procedures (engine room alarm, bridge alert, maintenance log entry).
Typ-universelle Inspektionspunkte fuer ODME System (verifiziert, 2026-06).
Insatech Marine (distributor/integrator)
1- Area: Calibration Certificate Status and ValidityCheck: Verify that current valid ODME calibration certificate is onboard, checked within 12 months (annual verification requirement), and renewed every 5 years. Certificate must be from authorized service agent per MEPC.108(49). Check for broken seals indicating unauthorized intervention.
- Area: Oil Content Meter Accuracy and Cell FoulingCheck: Inspect oil content meter for optical cell cleanliness and condition. Test system accuracy with known standard (e.g., clean water baseline and 10 ppm calibration standard). Check for automatic window flushing system functionality. Accuracy must remain within +/- 10 ppm or +/- 10% (whichever greater) per MEPC.108(49) section 6.2.2.
- Area: Flow Meter and Pitot Tube IntegrityCheck: Verify flow meter operational status and Pitot tube positioning in discharge line. Check pressure differential transmitter readings for reasonableness. Confirm sample flow rate is within design parameters (typically 4-5 L/min or 240-900 L/hour depending on model). Test discharge calculation (oil content x flow rate x time).
- Area: Data Recording and Log Records (3-year retention)Check: Review ODME discharge logs for last 3 years: verify oil content readings, discharge dates/times, vessel position (GPS), total quantities. Check for continuity gaps or unexplained system downtime. Confirm records stored in approved format (paper or electronic per MARPOL Annex I). Inspect for evidence of unauthorized modifications or record tampering.
- Area: System Failure and Overboard Valve Control FunctionCheck: Test automatic control valve solenoid operation: activate system simulation mode (if available) to verify that discharge valve closes when oil concentration exceeds 15 ppm threshold. Confirm mechanical interlocks and electrical failsafe mechanisms. Check pump motor operation and pressure relief settings. Verify failure notification procedures (engine room alarm, bridge alert, maintenance log entry).
Typ-universelle Inspektionspunkte fuer ODME System (verifiziert, 2026-06).
JINBO Marine (China)
1- Area: Calibration Certificate Status and ValidityCheck: Verify that current valid ODME calibration certificate is onboard, checked within 12 months (annual verification requirement), and renewed every 5 years. Certificate must be from authorized service agent per MEPC.108(49). Check for broken seals indicating unauthorized intervention.
- Area: Oil Content Meter Accuracy and Cell FoulingCheck: Inspect oil content meter for optical cell cleanliness and condition. Test system accuracy with known standard (e.g., clean water baseline and 10 ppm calibration standard). Check for automatic window flushing system functionality. Accuracy must remain within +/- 10 ppm or +/- 10% (whichever greater) per MEPC.108(49) section 6.2.2.
- Area: Flow Meter and Pitot Tube IntegrityCheck: Verify flow meter operational status and Pitot tube positioning in discharge line. Check pressure differential transmitter readings for reasonableness. Confirm sample flow rate is within design parameters (typically 4-5 L/min or 240-900 L/hour depending on model). Test discharge calculation (oil content x flow rate x time).
- Area: Data Recording and Log Records (3-year retention)Check: Review ODME discharge logs for last 3 years: verify oil content readings, discharge dates/times, vessel position (GPS), total quantities. Check for continuity gaps or unexplained system downtime. Confirm records stored in approved format (paper or electronic per MARPOL Annex I). Inspect for evidence of unauthorized modifications or record tampering.
- Area: System Failure and Overboard Valve Control FunctionCheck: Test automatic control valve solenoid operation: activate system simulation mode (if available) to verify that discharge valve closes when oil concentration exceeds 15 ppm threshold. Confirm mechanical interlocks and electrical failsafe mechanisms. Check pump motor operation and pressure relief settings. Verify failure notification procedures (engine room alarm, bridge alert, maintenance log entry).
Typ-universelle Inspektionspunkte fuer ODME System (verifiziert, 2026-06).
JOWA AB (Sweden)
1- Area: Calibration Certificate Status and ValidityCheck: Verify that current valid ODME calibration certificate is onboard, checked within 12 months (annual verification requirement), and renewed every 5 years. Certificate must be from authorized service agent per MEPC.108(49). Check for broken seals indicating unauthorized intervention.
- Area: Oil Content Meter Accuracy and Cell FoulingCheck: Inspect oil content meter for optical cell cleanliness and condition. Test system accuracy with known standard (e.g., clean water baseline and 10 ppm calibration standard). Check for automatic window flushing system functionality. Accuracy must remain within +/- 10 ppm or +/- 10% (whichever greater) per MEPC.108(49) section 6.2.2.
- Area: Flow Meter and Pitot Tube IntegrityCheck: Verify flow meter operational status and Pitot tube positioning in discharge line. Check pressure differential transmitter readings for reasonableness. Confirm sample flow rate is within design parameters (typically 4-5 L/min or 240-900 L/hour depending on model). Test discharge calculation (oil content x flow rate x time).
- Area: Data Recording and Log Records (3-year retention)Check: Review ODME discharge logs for last 3 years: verify oil content readings, discharge dates/times, vessel position (GPS), total quantities. Check for continuity gaps or unexplained system downtime. Confirm records stored in approved format (paper or electronic per MARPOL Annex I). Inspect for evidence of unauthorized modifications or record tampering.
- Area: System Failure and Overboard Valve Control FunctionCheck: Test automatic control valve solenoid operation: activate system simulation mode (if available) to verify that discharge valve closes when oil concentration exceeds 15 ppm threshold. Confirm mechanical interlocks and electrical failsafe mechanisms. Check pump motor operation and pressure relief settings. Verify failure notification procedures (engine room alarm, bridge alert, maintenance log entry).
Typ-universelle Inspektionspunkte fuer ODME System (verifiziert, 2026-06).
Lastmar Engineering (Turkey)
1- Area: Calibration Certificate Status and ValidityCheck: Verify that current valid ODME calibration certificate is onboard, checked within 12 months (annual verification requirement), and renewed every 5 years. Certificate must be from authorized service agent per MEPC.108(49). Check for broken seals indicating unauthorized intervention.
- Area: Oil Content Meter Accuracy and Cell FoulingCheck: Inspect oil content meter for optical cell cleanliness and condition. Test system accuracy with known standard (e.g., clean water baseline and 10 ppm calibration standard). Check for automatic window flushing system functionality. Accuracy must remain within +/- 10 ppm or +/- 10% (whichever greater) per MEPC.108(49) section 6.2.2.
- Area: Flow Meter and Pitot Tube IntegrityCheck: Verify flow meter operational status and Pitot tube positioning in discharge line. Check pressure differential transmitter readings for reasonableness. Confirm sample flow rate is within design parameters (typically 4-5 L/min or 240-900 L/hour depending on model). Test discharge calculation (oil content x flow rate x time).
- Area: Data Recording and Log Records (3-year retention)Check: Review ODME discharge logs for last 3 years: verify oil content readings, discharge dates/times, vessel position (GPS), total quantities. Check for continuity gaps or unexplained system downtime. Confirm records stored in approved format (paper or electronic per MARPOL Annex I). Inspect for evidence of unauthorized modifications or record tampering.
- Area: System Failure and Overboard Valve Control FunctionCheck: Test automatic control valve solenoid operation: activate system simulation mode (if available) to verify that discharge valve closes when oil concentration exceeds 15 ppm threshold. Confirm mechanical interlocks and electrical failsafe mechanisms. Check pump motor operation and pressure relief settings. Verify failure notification procedures (engine room alarm, bridge alert, maintenance log entry).
Typ-universelle Inspektionspunkte fuer ODME System (verifiziert, 2026-06).
Marel Service
1- Area: Calibration Certificate Status and ValidityCheck: Verify that current valid ODME calibration certificate is onboard, checked within 12 months (annual verification requirement), and renewed every 5 years. Certificate must be from authorized service agent per MEPC.108(49). Check for broken seals indicating unauthorized intervention.
- Area: Oil Content Meter Accuracy and Cell FoulingCheck: Inspect oil content meter for optical cell cleanliness and condition. Test system accuracy with known standard (e.g., clean water baseline and 10 ppm calibration standard). Check for automatic window flushing system functionality. Accuracy must remain within +/- 10 ppm or +/- 10% (whichever greater) per MEPC.108(49) section 6.2.2.
- Area: Flow Meter and Pitot Tube IntegrityCheck: Verify flow meter operational status and Pitot tube positioning in discharge line. Check pressure differential transmitter readings for reasonableness. Confirm sample flow rate is within design parameters (typically 4-5 L/min or 240-900 L/hour depending on model). Test discharge calculation (oil content x flow rate x time).
- Area: Data Recording and Log Records (3-year retention)Check: Review ODME discharge logs for last 3 years: verify oil content readings, discharge dates/times, vessel position (GPS), total quantities. Check for continuity gaps or unexplained system downtime. Confirm records stored in approved format (paper or electronic per MARPOL Annex I). Inspect for evidence of unauthorized modifications or record tampering.
- Area: System Failure and Overboard Valve Control FunctionCheck: Test automatic control valve solenoid operation: activate system simulation mode (if available) to verify that discharge valve closes when oil concentration exceeds 15 ppm threshold. Confirm mechanical interlocks and electrical failsafe mechanisms. Check pump motor operation and pressure relief settings. Verify failure notification procedures (engine room alarm, bridge alert, maintenance log entry).
Typ-universelle Inspektionspunkte fuer ODME System (verifiziert, 2026-06).
Metromac (KSB Seil distributor)
1- Area: Calibration Certificate Status and ValidityCheck: Verify that current valid ODME calibration certificate is onboard, checked within 12 months (annual verification requirement), and renewed every 5 years. Certificate must be from authorized service agent per MEPC.108(49). Check for broken seals indicating unauthorized intervention.
- Area: Oil Content Meter Accuracy and Cell FoulingCheck: Inspect oil content meter for optical cell cleanliness and condition. Test system accuracy with known standard (e.g., clean water baseline and 10 ppm calibration standard). Check for automatic window flushing system functionality. Accuracy must remain within +/- 10 ppm or +/- 10% (whichever greater) per MEPC.108(49) section 6.2.2.
- Area: Flow Meter and Pitot Tube IntegrityCheck: Verify flow meter operational status and Pitot tube positioning in discharge line. Check pressure differential transmitter readings for reasonableness. Confirm sample flow rate is within design parameters (typically 4-5 L/min or 240-900 L/hour depending on model). Test discharge calculation (oil content x flow rate x time).
- Area: Data Recording and Log Records (3-year retention)Check: Review ODME discharge logs for last 3 years: verify oil content readings, discharge dates/times, vessel position (GPS), total quantities. Check for continuity gaps or unexplained system downtime. Confirm records stored in approved format (paper or electronic per MARPOL Annex I). Inspect for evidence of unauthorized modifications or record tampering.
- Area: System Failure and Overboard Valve Control FunctionCheck: Test automatic control valve solenoid operation: activate system simulation mode (if available) to verify that discharge valve closes when oil concentration exceeds 15 ppm threshold. Confirm mechanical interlocks and electrical failsafe mechanisms. Check pump motor operation and pressure relief settings. Verify failure notification procedures (engine room alarm, bridge alert, maintenance log entry).
Typ-universelle Inspektionspunkte fuer ODME System (verifiziert, 2026-06).
Rivertrace
1- Optical sensor fouling
- Sample pump failure
- Flow meter malfunction
- Data recording failure
Swift Marine Tech Services (Singapore - Rivertrace partner)
1- Area: Calibration Certificate Status and ValidityCheck: Verify that current valid ODME calibration certificate is onboard, checked within 12 months (annual verification requirement), and renewed every 5 years. Certificate must be from authorized service agent per MEPC.108(49). Check for broken seals indicating unauthorized intervention.
- Area: Oil Content Meter Accuracy and Cell FoulingCheck: Inspect oil content meter for optical cell cleanliness and condition. Test system accuracy with known standard (e.g., clean water baseline and 10 ppm calibration standard). Check for automatic window flushing system functionality. Accuracy must remain within +/- 10 ppm or +/- 10% (whichever greater) per MEPC.108(49) section 6.2.2.
- Area: Flow Meter and Pitot Tube IntegrityCheck: Verify flow meter operational status and Pitot tube positioning in discharge line. Check pressure differential transmitter readings for reasonableness. Confirm sample flow rate is within design parameters (typically 4-5 L/min or 240-900 L/hour depending on model). Test discharge calculation (oil content x flow rate x time).
- Area: Data Recording and Log Records (3-year retention)Check: Review ODME discharge logs for last 3 years: verify oil content readings, discharge dates/times, vessel position (GPS), total quantities. Check for continuity gaps or unexplained system downtime. Confirm records stored in approved format (paper or electronic per MARPOL Annex I). Inspect for evidence of unauthorized modifications or record tampering.
- Area: System Failure and Overboard Valve Control FunctionCheck: Test automatic control valve solenoid operation: activate system simulation mode (if available) to verify that discharge valve closes when oil concentration exceeds 15 ppm threshold. Confirm mechanical interlocks and electrical failsafe mechanisms. Check pump motor operation and pressure relief settings. Verify failure notification procedures (engine room alarm, bridge alert, maintenance log entry).
Typ-universelle Inspektionspunkte fuer ODME System (verifiziert, 2026-06).
VAF Instruments
1- Sensor window fouling
- Flow control malfunction
- Recording failure
VAF Instruments (Netherlands)
1- Area: Calibration Certificate Status and ValidityCheck: Verify that current valid ODME calibration certificate is onboard, checked within 12 months (annual verification requirement), and renewed every 5 years. Certificate must be from authorized service agent per MEPC.108(49). Check for broken seals indicating unauthorized intervention.
- Area: Oil Content Meter Accuracy and Cell FoulingCheck: Inspect oil content meter for optical cell cleanliness and condition. Test system accuracy with known standard (e.g., clean water baseline and 10 ppm calibration standard). Check for automatic window flushing system functionality. Accuracy must remain within +/- 10 ppm or +/- 10% (whichever greater) per MEPC.108(49) section 6.2.2.
- Area: Flow Meter and Pitot Tube IntegrityCheck: Verify flow meter operational status and Pitot tube positioning in discharge line. Check pressure differential transmitter readings for reasonableness. Confirm sample flow rate is within design parameters (typically 4-5 L/min or 240-900 L/hour depending on model). Test discharge calculation (oil content x flow rate x time).
- Area: Data Recording and Log Records (3-year retention)Check: Review ODME discharge logs for last 3 years: verify oil content readings, discharge dates/times, vessel position (GPS), total quantities. Check for continuity gaps or unexplained system downtime. Confirm records stored in approved format (paper or electronic per MARPOL Annex I). Inspect for evidence of unauthorized modifications or record tampering.
- Area: System Failure and Overboard Valve Control FunctionCheck: Test automatic control valve solenoid operation: activate system simulation mode (if available) to verify that discharge valve closes when oil concentration exceeds 15 ppm threshold. Confirm mechanical interlocks and electrical failsafe mechanisms. Check pump motor operation and pressure relief settings. Verify failure notification procedures (engine room alarm, bridge alert, maintenance log entry).
Typ-universelle Inspektionspunkte fuer ODME System (verifiziert, 2026-06).
Yokogawa (Marex)
1- IR sensor drift
- Sample line blockage
- Data logger failure