medium 19 / 19 models (Inspector)
Oil content monitoring and control systems for overboard discharge
Inspector Mode Show All 19 / 19 with inspector value

17 manufacturers · 19 models

KSB Seil Co., Ltd.

2
ODME S-3000 Ver.2
Application
Crude and product tanker discharge monitoring with biofuel support
Common Failures & Inspection Points
  • Area: Calibration Certificate Status and Validity
    Check: Verify that current valid ODME calibration certificate is onboard, checked within 12 months (annual verification requirement), and renewed every 5 years. Certificate must be from authorized service agent per MEPC.108(49). Check for broken seals indicating unauthorized intervention.
  • Area: Oil Content Meter Accuracy and Cell Fouling
    Check: Inspect oil content meter for optical cell cleanliness and condition. Test system accuracy with known standard (e.g., clean water baseline and 10 ppm calibration standard). Check for automatic window flushing system functionality. Accuracy must remain within +/- 10 ppm or +/- 10% (whichever greater) per MEPC.108(49) section 6.2.2.
  • Area: Flow Meter and Pitot Tube Integrity
    Check: Verify flow meter operational status and Pitot tube positioning in discharge line. Check pressure differential transmitter readings for reasonableness. Confirm sample flow rate is within design parameters (typically 4-5 L/min or 240-900 L/hour depending on model). Test discharge calculation (oil content x flow rate x time).
  • Area: Data Recording and Log Records (3-year retention)
    Check: Review ODME discharge logs for last 3 years: verify oil content readings, discharge dates/times, vessel position (GPS), total quantities. Check for continuity gaps or unexplained system downtime. Confirm records stored in approved format (paper or electronic per MARPOL Annex I). Inspect for evidence of unauthorized modifications or record tampering.
  • Area: System Failure and Overboard Valve Control Function
    Check: Test automatic control valve solenoid operation: activate system simulation mode (if available) to verify that discharge valve closes when oil concentration exceeds 15 ppm threshold. Confirm mechanical interlocks and electrical failsafe mechanisms. Check pump motor operation and pressure relief settings. Verify failure notification procedures (engine room alarm, bridge alert, maintenance log entry).

Typ-universelle Inspektionspunkte fuer ODME System (verifiziert, 2026-06).

ODME S 663 MK III
Application
Retrofit ODME for vessels built before 2005
Common Failures & Inspection Points
  • Area: Calibration Certificate Status and Validity
    Check: Verify that current valid ODME calibration certificate is onboard, checked within 12 months (annual verification requirement), and renewed every 5 years. Certificate must be from authorized service agent per MEPC.108(49). Check for broken seals indicating unauthorized intervention.
  • Area: Oil Content Meter Accuracy and Cell Fouling
    Check: Inspect oil content meter for optical cell cleanliness and condition. Test system accuracy with known standard (e.g., clean water baseline and 10 ppm calibration standard). Check for automatic window flushing system functionality. Accuracy must remain within +/- 10 ppm or +/- 10% (whichever greater) per MEPC.108(49) section 6.2.2.
  • Area: Flow Meter and Pitot Tube Integrity
    Check: Verify flow meter operational status and Pitot tube positioning in discharge line. Check pressure differential transmitter readings for reasonableness. Confirm sample flow rate is within design parameters (typically 4-5 L/min or 240-900 L/hour depending on model). Test discharge calculation (oil content x flow rate x time).
  • Area: Data Recording and Log Records (3-year retention)
    Check: Review ODME discharge logs for last 3 years: verify oil content readings, discharge dates/times, vessel position (GPS), total quantities. Check for continuity gaps or unexplained system downtime. Confirm records stored in approved format (paper or electronic per MARPOL Annex I). Inspect for evidence of unauthorized modifications or record tampering.
  • Area: System Failure and Overboard Valve Control Function
    Check: Test automatic control valve solenoid operation: activate system simulation mode (if available) to verify that discharge valve closes when oil concentration exceeds 15 ppm threshold. Confirm mechanical interlocks and electrical failsafe mechanisms. Check pump motor operation and pressure relief settings. Verify failure notification procedures (engine room alarm, bridge alert, maintenance log entry).

Typ-universelle Inspektionspunkte fuer ODME System (verifiziert, 2026-06).

Rivertrace Engineering

2
Smart ODME
Application
Oil tanker slop water and ballast discharge monitoring
Common Failures & Inspection Points
  • Area: Calibration Certificate Status and Validity
    Check: Verify that current valid ODME calibration certificate is onboard, checked within 12 months (annual verification requirement), and renewed every 5 years. Certificate must be from authorized service agent per MEPC.108(49). Check for broken seals indicating unauthorized intervention.
  • Area: Oil Content Meter Accuracy and Cell Fouling
    Check: Inspect oil content meter for optical cell cleanliness and condition. Test system accuracy with known standard (e.g., clean water baseline and 10 ppm calibration standard). Check for automatic window flushing system functionality. Accuracy must remain within +/- 10 ppm or +/- 10% (whichever greater) per MEPC.108(49) section 6.2.2.
  • Area: Flow Meter and Pitot Tube Integrity
    Check: Verify flow meter operational status and Pitot tube positioning in discharge line. Check pressure differential transmitter readings for reasonableness. Confirm sample flow rate is within design parameters (typically 4-5 L/min or 240-900 L/hour depending on model). Test discharge calculation (oil content x flow rate x time).
  • Area: Data Recording and Log Records (3-year retention)
    Check: Review ODME discharge logs for last 3 years: verify oil content readings, discharge dates/times, vessel position (GPS), total quantities. Check for continuity gaps or unexplained system downtime. Confirm records stored in approved format (paper or electronic per MARPOL Annex I). Inspect for evidence of unauthorized modifications or record tampering.
  • Area: System Failure and Overboard Valve Control Function
    Check: Test automatic control valve solenoid operation: activate system simulation mode (if available) to verify that discharge valve closes when oil concentration exceeds 15 ppm threshold. Confirm mechanical interlocks and electrical failsafe mechanisms. Check pump motor operation and pressure relief settings. Verify failure notification procedures (engine room alarm, bridge alert, maintenance log entry).

Typ-universelle Inspektionspunkte fuer ODME System (verifiziert, 2026-06).

Smart ODME 50M
Application
Low-range oil in water monitoring for ballast discharge
Common Failures & Inspection Points
  • Area: Calibration Certificate Status and Validity
    Check: Verify that current valid ODME calibration certificate is onboard, checked within 12 months (annual verification requirement), and renewed every 5 years. Certificate must be from authorized service agent per MEPC.108(49). Check for broken seals indicating unauthorized intervention.
  • Area: Oil Content Meter Accuracy and Cell Fouling
    Check: Inspect oil content meter for optical cell cleanliness and condition. Test system accuracy with known standard (e.g., clean water baseline and 10 ppm calibration standard). Check for automatic window flushing system functionality. Accuracy must remain within +/- 10 ppm or +/- 10% (whichever greater) per MEPC.108(49) section 6.2.2.
  • Area: Flow Meter and Pitot Tube Integrity
    Check: Verify flow meter operational status and Pitot tube positioning in discharge line. Check pressure differential transmitter readings for reasonableness. Confirm sample flow rate is within design parameters (typically 4-5 L/min or 240-900 L/hour depending on model). Test discharge calculation (oil content x flow rate x time).
  • Area: Data Recording and Log Records (3-year retention)
    Check: Review ODME discharge logs for last 3 years: verify oil content readings, discharge dates/times, vessel position (GPS), total quantities. Check for continuity gaps or unexplained system downtime. Confirm records stored in approved format (paper or electronic per MARPOL Annex I). Inspect for evidence of unauthorized modifications or record tampering.
  • Area: System Failure and Overboard Valve Control Function
    Check: Test automatic control valve solenoid operation: activate system simulation mode (if available) to verify that discharge valve closes when oil concentration exceeds 15 ppm threshold. Confirm mechanical interlocks and electrical failsafe mechanisms. Check pump motor operation and pressure relief settings. Verify failure notification procedures (engine room alarm, bridge alert, maintenance log entry).

Typ-universelle Inspektionspunkte fuer ODME System (verifiziert, 2026-06).

AJ Marine Solution (Bangladesh - distributor)

1
VAF Oilcon Mark 6 ODME
Application
Distributed oil discharge monitoring systems for South Asian fleets
Common Failures & Inspection Points
  • Area: Calibration Certificate Status and Validity
    Check: Verify that current valid ODME calibration certificate is onboard, checked within 12 months (annual verification requirement), and renewed every 5 years. Certificate must be from authorized service agent per MEPC.108(49). Check for broken seals indicating unauthorized intervention.
  • Area: Oil Content Meter Accuracy and Cell Fouling
    Check: Inspect oil content meter for optical cell cleanliness and condition. Test system accuracy with known standard (e.g., clean water baseline and 10 ppm calibration standard). Check for automatic window flushing system functionality. Accuracy must remain within +/- 10 ppm or +/- 10% (whichever greater) per MEPC.108(49) section 6.2.2.
  • Area: Flow Meter and Pitot Tube Integrity
    Check: Verify flow meter operational status and Pitot tube positioning in discharge line. Check pressure differential transmitter readings for reasonableness. Confirm sample flow rate is within design parameters (typically 4-5 L/min or 240-900 L/hour depending on model). Test discharge calculation (oil content x flow rate x time).
  • Area: Data Recording and Log Records (3-year retention)
    Check: Review ODME discharge logs for last 3 years: verify oil content readings, discharge dates/times, vessel position (GPS), total quantities. Check for continuity gaps or unexplained system downtime. Confirm records stored in approved format (paper or electronic per MARPOL Annex I). Inspect for evidence of unauthorized modifications or record tampering.
  • Area: System Failure and Overboard Valve Control Function
    Check: Test automatic control valve solenoid operation: activate system simulation mode (if available) to verify that discharge valve closes when oil concentration exceeds 15 ppm threshold. Confirm mechanical interlocks and electrical failsafe mechanisms. Check pump motor operation and pressure relief settings. Verify failure notification procedures (engine room alarm, bridge alert, maintenance log entry).

Typ-universelle Inspektionspunkte fuer ODME System (verifiziert, 2026-06).

Brannstrom Sweden AB

1
CleanTrack 1000B
Application
Fourth-generation ODME for modern crude and chemical tankers
Common Failures & Inspection Points
  • Area: Calibration Certificate Status and Validity
    Check: Verify that current valid ODME calibration certificate is onboard, checked within 12 months (annual verification requirement), and renewed every 5 years. Certificate must be from authorized service agent per MEPC.108(49). Check for broken seals indicating unauthorized intervention.
  • Area: Oil Content Meter Accuracy and Cell Fouling
    Check: Inspect oil content meter for optical cell cleanliness and condition. Test system accuracy with known standard (e.g., clean water baseline and 10 ppm calibration standard). Check for automatic window flushing system functionality. Accuracy must remain within +/- 10 ppm or +/- 10% (whichever greater) per MEPC.108(49) section 6.2.2.
  • Area: Flow Meter and Pitot Tube Integrity
    Check: Verify flow meter operational status and Pitot tube positioning in discharge line. Check pressure differential transmitter readings for reasonableness. Confirm sample flow rate is within design parameters (typically 4-5 L/min or 240-900 L/hour depending on model). Test discharge calculation (oil content x flow rate x time).
  • Area: Data Recording and Log Records (3-year retention)
    Check: Review ODME discharge logs for last 3 years: verify oil content readings, discharge dates/times, vessel position (GPS), total quantities. Check for continuity gaps or unexplained system downtime. Confirm records stored in approved format (paper or electronic per MARPOL Annex I). Inspect for evidence of unauthorized modifications or record tampering.
  • Area: System Failure and Overboard Valve Control Function
    Check: Test automatic control valve solenoid operation: activate system simulation mode (if available) to verify that discharge valve closes when oil concentration exceeds 15 ppm threshold. Confirm mechanical interlocks and electrical failsafe mechanisms. Check pump motor operation and pressure relief settings. Verify failure notification procedures (engine room alarm, bridge alert, maintenance log entry).

Typ-universelle Inspektionspunkte fuer ODME System (verifiziert, 2026-06).

Deckma

1
OMD-24 ODME
0-15 ppm · Ballast Water Oil Content · odme
Type
odme
Range (ppm)
0-15
Marpol
ja
Origin
Germany
Common Failures & Inspection Points
  • Sensor contamination
  • Pump diaphragm failure
  • Recording unit malfunction
Service: German manufacturer. Annual calibration and survey.
Spare Parts: Ersatzteile über Deckma oder zugelassene Vertriebspartner. Lead time: 2-6 Wochen.

Deyuan Marine (China)

1
CleanTrack 1000B ODME
Application
Crude oil and petroleum product tanker discharge monitoring
Common Failures & Inspection Points
  • Area: Calibration Certificate Status and Validity
    Check: Verify that current valid ODME calibration certificate is onboard, checked within 12 months (annual verification requirement), and renewed every 5 years. Certificate must be from authorized service agent per MEPC.108(49). Check for broken seals indicating unauthorized intervention.
  • Area: Oil Content Meter Accuracy and Cell Fouling
    Check: Inspect oil content meter for optical cell cleanliness and condition. Test system accuracy with known standard (e.g., clean water baseline and 10 ppm calibration standard). Check for automatic window flushing system functionality. Accuracy must remain within +/- 10 ppm or +/- 10% (whichever greater) per MEPC.108(49) section 6.2.2.
  • Area: Flow Meter and Pitot Tube Integrity
    Check: Verify flow meter operational status and Pitot tube positioning in discharge line. Check pressure differential transmitter readings for reasonableness. Confirm sample flow rate is within design parameters (typically 4-5 L/min or 240-900 L/hour depending on model). Test discharge calculation (oil content x flow rate x time).
  • Area: Data Recording and Log Records (3-year retention)
    Check: Review ODME discharge logs for last 3 years: verify oil content readings, discharge dates/times, vessel position (GPS), total quantities. Check for continuity gaps or unexplained system downtime. Confirm records stored in approved format (paper or electronic per MARPOL Annex I). Inspect for evidence of unauthorized modifications or record tampering.
  • Area: System Failure and Overboard Valve Control Function
    Check: Test automatic control valve solenoid operation: activate system simulation mode (if available) to verify that discharge valve closes when oil concentration exceeds 15 ppm threshold. Confirm mechanical interlocks and electrical failsafe mechanisms. Check pump motor operation and pressure relief settings. Verify failure notification procedures (engine room alarm, bridge alert, maintenance log entry).

Typ-universelle Inspektionspunkte fuer ODME System (verifiziert, 2026-06).

Insatech Marine (distributor/integrator)

1
Smart ODME by Rivertrace
Application
Integrated ODME solution for tanker fleets
Common Failures & Inspection Points
  • Area: Calibration Certificate Status and Validity
    Check: Verify that current valid ODME calibration certificate is onboard, checked within 12 months (annual verification requirement), and renewed every 5 years. Certificate must be from authorized service agent per MEPC.108(49). Check for broken seals indicating unauthorized intervention.
  • Area: Oil Content Meter Accuracy and Cell Fouling
    Check: Inspect oil content meter for optical cell cleanliness and condition. Test system accuracy with known standard (e.g., clean water baseline and 10 ppm calibration standard). Check for automatic window flushing system functionality. Accuracy must remain within +/- 10 ppm or +/- 10% (whichever greater) per MEPC.108(49) section 6.2.2.
  • Area: Flow Meter and Pitot Tube Integrity
    Check: Verify flow meter operational status and Pitot tube positioning in discharge line. Check pressure differential transmitter readings for reasonableness. Confirm sample flow rate is within design parameters (typically 4-5 L/min or 240-900 L/hour depending on model). Test discharge calculation (oil content x flow rate x time).
  • Area: Data Recording and Log Records (3-year retention)
    Check: Review ODME discharge logs for last 3 years: verify oil content readings, discharge dates/times, vessel position (GPS), total quantities. Check for continuity gaps or unexplained system downtime. Confirm records stored in approved format (paper or electronic per MARPOL Annex I). Inspect for evidence of unauthorized modifications or record tampering.
  • Area: System Failure and Overboard Valve Control Function
    Check: Test automatic control valve solenoid operation: activate system simulation mode (if available) to verify that discharge valve closes when oil concentration exceeds 15 ppm threshold. Confirm mechanical interlocks and electrical failsafe mechanisms. Check pump motor operation and pressure relief settings. Verify failure notification procedures (engine room alarm, bridge alert, maintenance log entry).

Typ-universelle Inspektionspunkte fuer ODME System (verifiziert, 2026-06).

JINBO Marine (China)

1
ODME-1000
Application
Oil content control in ship sewage and ballast discharge
Common Failures & Inspection Points
  • Area: Calibration Certificate Status and Validity
    Check: Verify that current valid ODME calibration certificate is onboard, checked within 12 months (annual verification requirement), and renewed every 5 years. Certificate must be from authorized service agent per MEPC.108(49). Check for broken seals indicating unauthorized intervention.
  • Area: Oil Content Meter Accuracy and Cell Fouling
    Check: Inspect oil content meter for optical cell cleanliness and condition. Test system accuracy with known standard (e.g., clean water baseline and 10 ppm calibration standard). Check for automatic window flushing system functionality. Accuracy must remain within +/- 10 ppm or +/- 10% (whichever greater) per MEPC.108(49) section 6.2.2.
  • Area: Flow Meter and Pitot Tube Integrity
    Check: Verify flow meter operational status and Pitot tube positioning in discharge line. Check pressure differential transmitter readings for reasonableness. Confirm sample flow rate is within design parameters (typically 4-5 L/min or 240-900 L/hour depending on model). Test discharge calculation (oil content x flow rate x time).
  • Area: Data Recording and Log Records (3-year retention)
    Check: Review ODME discharge logs for last 3 years: verify oil content readings, discharge dates/times, vessel position (GPS), total quantities. Check for continuity gaps or unexplained system downtime. Confirm records stored in approved format (paper or electronic per MARPOL Annex I). Inspect for evidence of unauthorized modifications or record tampering.
  • Area: System Failure and Overboard Valve Control Function
    Check: Test automatic control valve solenoid operation: activate system simulation mode (if available) to verify that discharge valve closes when oil concentration exceeds 15 ppm threshold. Confirm mechanical interlocks and electrical failsafe mechanisms. Check pump motor operation and pressure relief settings. Verify failure notification procedures (engine room alarm, bridge alert, maintenance log entry).

Typ-universelle Inspektionspunkte fuer ODME System (verifiziert, 2026-06).

JOWA AB (Sweden)

1
ODME 2005
Application
Third-generation oil discharge monitoring for all tanker types
Common Failures & Inspection Points
  • Area: Calibration Certificate Status and Validity
    Check: Verify that current valid ODME calibration certificate is onboard, checked within 12 months (annual verification requirement), and renewed every 5 years. Certificate must be from authorized service agent per MEPC.108(49). Check for broken seals indicating unauthorized intervention.
  • Area: Oil Content Meter Accuracy and Cell Fouling
    Check: Inspect oil content meter for optical cell cleanliness and condition. Test system accuracy with known standard (e.g., clean water baseline and 10 ppm calibration standard). Check for automatic window flushing system functionality. Accuracy must remain within +/- 10 ppm or +/- 10% (whichever greater) per MEPC.108(49) section 6.2.2.
  • Area: Flow Meter and Pitot Tube Integrity
    Check: Verify flow meter operational status and Pitot tube positioning in discharge line. Check pressure differential transmitter readings for reasonableness. Confirm sample flow rate is within design parameters (typically 4-5 L/min or 240-900 L/hour depending on model). Test discharge calculation (oil content x flow rate x time).
  • Area: Data Recording and Log Records (3-year retention)
    Check: Review ODME discharge logs for last 3 years: verify oil content readings, discharge dates/times, vessel position (GPS), total quantities. Check for continuity gaps or unexplained system downtime. Confirm records stored in approved format (paper or electronic per MARPOL Annex I). Inspect for evidence of unauthorized modifications or record tampering.
  • Area: System Failure and Overboard Valve Control Function
    Check: Test automatic control valve solenoid operation: activate system simulation mode (if available) to verify that discharge valve closes when oil concentration exceeds 15 ppm threshold. Confirm mechanical interlocks and electrical failsafe mechanisms. Check pump motor operation and pressure relief settings. Verify failure notification procedures (engine room alarm, bridge alert, maintenance log entry).

Typ-universelle Inspektionspunkte fuer ODME System (verifiziert, 2026-06).

Lastmar Engineering (Turkey)

1
Oil Discharge Monitoring Equipment System
Application
MARPOL Annex I compliant tanker discharge monitoring
Common Failures & Inspection Points
  • Area: Calibration Certificate Status and Validity
    Check: Verify that current valid ODME calibration certificate is onboard, checked within 12 months (annual verification requirement), and renewed every 5 years. Certificate must be from authorized service agent per MEPC.108(49). Check for broken seals indicating unauthorized intervention.
  • Area: Oil Content Meter Accuracy and Cell Fouling
    Check: Inspect oil content meter for optical cell cleanliness and condition. Test system accuracy with known standard (e.g., clean water baseline and 10 ppm calibration standard). Check for automatic window flushing system functionality. Accuracy must remain within +/- 10 ppm or +/- 10% (whichever greater) per MEPC.108(49) section 6.2.2.
  • Area: Flow Meter and Pitot Tube Integrity
    Check: Verify flow meter operational status and Pitot tube positioning in discharge line. Check pressure differential transmitter readings for reasonableness. Confirm sample flow rate is within design parameters (typically 4-5 L/min or 240-900 L/hour depending on model). Test discharge calculation (oil content x flow rate x time).
  • Area: Data Recording and Log Records (3-year retention)
    Check: Review ODME discharge logs for last 3 years: verify oil content readings, discharge dates/times, vessel position (GPS), total quantities. Check for continuity gaps or unexplained system downtime. Confirm records stored in approved format (paper or electronic per MARPOL Annex I). Inspect for evidence of unauthorized modifications or record tampering.
  • Area: System Failure and Overboard Valve Control Function
    Check: Test automatic control valve solenoid operation: activate system simulation mode (if available) to verify that discharge valve closes when oil concentration exceeds 15 ppm threshold. Confirm mechanical interlocks and electrical failsafe mechanisms. Check pump motor operation and pressure relief settings. Verify failure notification procedures (engine room alarm, bridge alert, maintenance log entry).

Typ-universelle Inspektionspunkte fuer ODME System (verifiziert, 2026-06).

Marel Service

1
CleanTrack 1000B
Application
Fourth-generation ODME for hazardous cargo areas
Common Failures & Inspection Points
  • Area: Calibration Certificate Status and Validity
    Check: Verify that current valid ODME calibration certificate is onboard, checked within 12 months (annual verification requirement), and renewed every 5 years. Certificate must be from authorized service agent per MEPC.108(49). Check for broken seals indicating unauthorized intervention.
  • Area: Oil Content Meter Accuracy and Cell Fouling
    Check: Inspect oil content meter for optical cell cleanliness and condition. Test system accuracy with known standard (e.g., clean water baseline and 10 ppm calibration standard). Check for automatic window flushing system functionality. Accuracy must remain within +/- 10 ppm or +/- 10% (whichever greater) per MEPC.108(49) section 6.2.2.
  • Area: Flow Meter and Pitot Tube Integrity
    Check: Verify flow meter operational status and Pitot tube positioning in discharge line. Check pressure differential transmitter readings for reasonableness. Confirm sample flow rate is within design parameters (typically 4-5 L/min or 240-900 L/hour depending on model). Test discharge calculation (oil content x flow rate x time).
  • Area: Data Recording and Log Records (3-year retention)
    Check: Review ODME discharge logs for last 3 years: verify oil content readings, discharge dates/times, vessel position (GPS), total quantities. Check for continuity gaps or unexplained system downtime. Confirm records stored in approved format (paper or electronic per MARPOL Annex I). Inspect for evidence of unauthorized modifications or record tampering.
  • Area: System Failure and Overboard Valve Control Function
    Check: Test automatic control valve solenoid operation: activate system simulation mode (if available) to verify that discharge valve closes when oil concentration exceeds 15 ppm threshold. Confirm mechanical interlocks and electrical failsafe mechanisms. Check pump motor operation and pressure relief settings. Verify failure notification procedures (engine room alarm, bridge alert, maintenance log entry).

Typ-universelle Inspektionspunkte fuer ODME System (verifiziert, 2026-06).

Metromac (KSB Seil distributor)

1
ODME S-3000
Application
Compliant discharge monitoring for major tanker fleets worldwide
Common Failures & Inspection Points
  • Area: Calibration Certificate Status and Validity
    Check: Verify that current valid ODME calibration certificate is onboard, checked within 12 months (annual verification requirement), and renewed every 5 years. Certificate must be from authorized service agent per MEPC.108(49). Check for broken seals indicating unauthorized intervention.
  • Area: Oil Content Meter Accuracy and Cell Fouling
    Check: Inspect oil content meter for optical cell cleanliness and condition. Test system accuracy with known standard (e.g., clean water baseline and 10 ppm calibration standard). Check for automatic window flushing system functionality. Accuracy must remain within +/- 10 ppm or +/- 10% (whichever greater) per MEPC.108(49) section 6.2.2.
  • Area: Flow Meter and Pitot Tube Integrity
    Check: Verify flow meter operational status and Pitot tube positioning in discharge line. Check pressure differential transmitter readings for reasonableness. Confirm sample flow rate is within design parameters (typically 4-5 L/min or 240-900 L/hour depending on model). Test discharge calculation (oil content x flow rate x time).
  • Area: Data Recording and Log Records (3-year retention)
    Check: Review ODME discharge logs for last 3 years: verify oil content readings, discharge dates/times, vessel position (GPS), total quantities. Check for continuity gaps or unexplained system downtime. Confirm records stored in approved format (paper or electronic per MARPOL Annex I). Inspect for evidence of unauthorized modifications or record tampering.
  • Area: System Failure and Overboard Valve Control Function
    Check: Test automatic control valve solenoid operation: activate system simulation mode (if available) to verify that discharge valve closes when oil concentration exceeds 15 ppm threshold. Confirm mechanical interlocks and electrical failsafe mechanisms. Check pump motor operation and pressure relief settings. Verify failure notification procedures (engine room alarm, bridge alert, maintenance log entry).

Typ-universelle Inspektionspunkte fuer ODME System (verifiziert, 2026-06).

Rivertrace

1
Smart ODME
0-15 ppm monitoring · Ballast Water Oil Content · odme
Type
odme
Range (ppm)
0-15
Marpol
ja
Common Failures & Inspection Points
  • Optical sensor fouling
  • Sample pump failure
  • Flow meter malfunction
  • Data recording failure
Service: MARPOL mandatory. Annual calibration. Sensor cleaning weekly.
Spare Parts: Ersatzteile über Rivertrace oder zugelassene Vertriebspartner. Lead time: 2-6 Wochen.

Swift Marine Tech Services (Singapore - Rivertrace partner)

1
Smart ODME - Authorized Service Center
Application
Installation, calibration, and maintenance of Smart ODME systems
Common Failures & Inspection Points
  • Area: Calibration Certificate Status and Validity
    Check: Verify that current valid ODME calibration certificate is onboard, checked within 12 months (annual verification requirement), and renewed every 5 years. Certificate must be from authorized service agent per MEPC.108(49). Check for broken seals indicating unauthorized intervention.
  • Area: Oil Content Meter Accuracy and Cell Fouling
    Check: Inspect oil content meter for optical cell cleanliness and condition. Test system accuracy with known standard (e.g., clean water baseline and 10 ppm calibration standard). Check for automatic window flushing system functionality. Accuracy must remain within +/- 10 ppm or +/- 10% (whichever greater) per MEPC.108(49) section 6.2.2.
  • Area: Flow Meter and Pitot Tube Integrity
    Check: Verify flow meter operational status and Pitot tube positioning in discharge line. Check pressure differential transmitter readings for reasonableness. Confirm sample flow rate is within design parameters (typically 4-5 L/min or 240-900 L/hour depending on model). Test discharge calculation (oil content x flow rate x time).
  • Area: Data Recording and Log Records (3-year retention)
    Check: Review ODME discharge logs for last 3 years: verify oil content readings, discharge dates/times, vessel position (GPS), total quantities. Check for continuity gaps or unexplained system downtime. Confirm records stored in approved format (paper or electronic per MARPOL Annex I). Inspect for evidence of unauthorized modifications or record tampering.
  • Area: System Failure and Overboard Valve Control Function
    Check: Test automatic control valve solenoid operation: activate system simulation mode (if available) to verify that discharge valve closes when oil concentration exceeds 15 ppm threshold. Confirm mechanical interlocks and electrical failsafe mechanisms. Check pump motor operation and pressure relief settings. Verify failure notification procedures (engine room alarm, bridge alert, maintenance log entry).

Typ-universelle Inspektionspunkte fuer ODME System (verifiziert, 2026-06).

VAF Instruments

1
VAF Marine OCM
0-15 ppm · Ballast Water Oil Content · odme
Type
odme
Range (ppm)
0-15
Marpol
ja
Origin
Netherlands
Common Failures & Inspection Points
  • Sensor window fouling
  • Flow control malfunction
  • Recording failure
Service: Dutch manufacturer. Annual calibration and class survey.
Spare Parts: Ersatzteile über VAF Instruments oder zugelassene Vertriebspartner. Lead time: 2-6 Wochen.

VAF Instruments (Netherlands)

1
Oilcon Mark 6M
Application
Ballast and slop water discharge monitoring for all tanker types
Common Failures & Inspection Points
  • Area: Calibration Certificate Status and Validity
    Check: Verify that current valid ODME calibration certificate is onboard, checked within 12 months (annual verification requirement), and renewed every 5 years. Certificate must be from authorized service agent per MEPC.108(49). Check for broken seals indicating unauthorized intervention.
  • Area: Oil Content Meter Accuracy and Cell Fouling
    Check: Inspect oil content meter for optical cell cleanliness and condition. Test system accuracy with known standard (e.g., clean water baseline and 10 ppm calibration standard). Check for automatic window flushing system functionality. Accuracy must remain within +/- 10 ppm or +/- 10% (whichever greater) per MEPC.108(49) section 6.2.2.
  • Area: Flow Meter and Pitot Tube Integrity
    Check: Verify flow meter operational status and Pitot tube positioning in discharge line. Check pressure differential transmitter readings for reasonableness. Confirm sample flow rate is within design parameters (typically 4-5 L/min or 240-900 L/hour depending on model). Test discharge calculation (oil content x flow rate x time).
  • Area: Data Recording and Log Records (3-year retention)
    Check: Review ODME discharge logs for last 3 years: verify oil content readings, discharge dates/times, vessel position (GPS), total quantities. Check for continuity gaps or unexplained system downtime. Confirm records stored in approved format (paper or electronic per MARPOL Annex I). Inspect for evidence of unauthorized modifications or record tampering.
  • Area: System Failure and Overboard Valve Control Function
    Check: Test automatic control valve solenoid operation: activate system simulation mode (if available) to verify that discharge valve closes when oil concentration exceeds 15 ppm threshold. Confirm mechanical interlocks and electrical failsafe mechanisms. Check pump motor operation and pressure relief settings. Verify failure notification procedures (engine room alarm, bridge alert, maintenance log entry).

Typ-universelle Inspektionspunkte fuer ODME System (verifiziert, 2026-06).

Yokogawa (Marex)

1
Yokogawa OCM-15 ODME
0-15 ppm · Ballast Water Oil Content · odme
Type
odme
Range (ppm)
0-15
Marpol
ja
Common Failures & Inspection Points
  • IR sensor drift
  • Sample line blockage
  • Data logger failure
Service: Japanese/Norwegian product. Annual calibration.
Spare Parts: Ersatzteile über Yokogawa (Marex) oder zugelassene Vertriebspartner. Lead time: 2-6 Wochen.