Technical Data

Oil measurement range 0-1000 ppm
Accuracy +/- 1 ppm
Resolution 1 ppm
Power supply 115/230V AC, 50-60Hz (switchable)
Motor 380-440V AC, 3-phase, 250W
Compliance MEPC.108(49), MEPC.240(65)

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Calibration Certificate Status and Validity

Verify that current valid ODME calibration certificate is onboard, checked within 12 months (annual verification requirement), and renewed every 5 years. Certificate must be from authorized service agent per MEPC.108(49). Check for broken seals indicating unauthorized intervention.

Oil Content Meter Accuracy and Cell Fouling

Inspect oil content meter for optical cell cleanliness and condition. Test system accuracy with known standard (e.g., clean water baseline and 10 ppm calibration standard). Check for automatic window flushing system functionality. Accuracy must remain within +/- 10 ppm or +/- 10% (whichever greater) per MEPC.108(49) section 6.2.2.

Flow Meter and Pitot Tube Integrity

Verify flow meter operational status and Pitot tube positioning in discharge line. Check pressure differential transmitter readings for reasonableness. Confirm sample flow rate is within design parameters (typically 4-5 L/min or 240-900 L/hour depending on model). Test discharge calculation (oil content x flow rate x time).

Data Recording and Log Records (3-year retention)

Review ODME discharge logs for last 3 years: verify oil content readings, discharge dates/times, vessel position (GPS), total quantities. Check for continuity gaps or unexplained system downtime. Confirm records stored in approved format (paper or electronic per MARPOL Annex I). Inspect for evidence of unauthorized modifications or record tampering.

System Failure and Overboard Valve Control Function

Test automatic control valve solenoid operation: activate system simulation mode (if available) to verify that discharge valve closes when oil concentration exceeds 15 ppm threshold. Confirm mechanical interlocks and electrical failsafe mechanisms. Check pump motor operation and pressure relief settings. Verify failure notification procedures (engine room alarm, bridge alert, maintenance log entry).

Type-general inspection and maintenance points for this equipment category — not model-specific.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →
Equipment Model #143902 · ✓ still in production