OceanSphereFree accountLog inDEENPL
OceanSphereENGINES
Library› Navigation› Radar & ECDIS› ECDIS
Radar & ECDIS

ECDIS

ECDIS replaces the paper chart as the primary means of navigation only when it runs official vector chart data (ENCs) with a valid backup arrangement a chart plotter running raster scans or a demo dataset is not ECDIS in the SOLAS sense, whatever the software calls itself.

3models
Kelvin Hughes
Knowledge

What to check on an ECDIS.

3 models from Kelvin Hughes in ECDIS. Below: the full model list.

What makes a system ECDIS rather than a chart plotter

The term ECDIS is reserved, under IMO performance standards, for a system that displays official Electronic Navigational Charts (ENCs) vector data issued or authorised by a national hydrographic office and meets a defined set of functional requirements: continuous position plotting, route planning and monitoring with automatic grounding and danger alarms, and a documented backup arrangement in case the primary unit fails. A consumer-grade chart plotter or a system running raster scans of paper charts (RNC) instead of ENCs does not meet this standard, even if it looks similar on screen, because it lacks the alarm-generating vector data model that lets the system understand what a depth contour or a charted wreck actually means to the vessel's draft. Where ECDIS is the approved primary means of navigation, SOLAS still requires an independent backup either a second ECDIS unit or paper charts corrected to the same standard.

ECDIS sensor and data arrangement
Block diagram of ECDIS fed by official ENC chart data and by GPS, gyro compass, speed log, AIS and radar sensors, showing the planned route and own ship position on the display, with a required independent backup arrangement.
Read the full guide

Main components

ENC database and licensing

Vector chart cells covering the vessel's trading area, issued under licence and kept current through a chart correction service. An expired licence or an uncorrected cell is a navigational deficiency, not just an administrative one, since it means the displayed chart no longer reflects promulgated notices to mariners.

Sensor inputs

Position from GPS/GNSS, commonly dual-source for redundancy, heading from gyro or satellite compass, and speed from log, all feeding the display so the vessel's position and predicted track update in real time against the chart.

Route planning and monitoring module

Lets the navigator lay a route with waypoints, cross-track limits and safety contour settings, then continuously checks the vessel's actual and predicted position against charted hazards, generating an alarm ahead of a grounding risk rather than after the fact.

Backup arrangement

A second, independently powered ECDIS unit or a full folio of corrected paper charts, arranged so a single failure power, software or hardware does not leave the bridge without a means of safe navigation.

Selection and sizing

  • Type approval to the current IMO performance standard and IHO presentation library edition, since older approvals can lag behind chart data updates.
  • Chart service coverage for the vessel's actual trading pattern, not just a demonstration region.
  • Sensor integration compatibility with the bridge's existing gyro, GPS and AIS, including redundant position sources for the required cross-check.
  • Screen size and bridge layout suitability for the required minimum display area under the performance standard.

Regulations and class

SOLAS Chapter V mandates ECDIS carriage on a phased schedule by ship type and tonnage, with paper charts remaining an acceptable backup where the vessel does not carry a second ECDIS. IMO's ECDIS performance standard and the associated IHO S-52 presentation library and S-57/S-101 data standards govern how chart data must be displayed and updated. Flag state and class both expect documented generic and type-specific ECDIS familiarisation training for watchkeeping officers under the STCW Manila amendments, checked at survey and during port state control inspections alongside chart currency.

Typical faults

FaultCauseConsequence
Outdated chart data displayedCorrection service lapsed or updates not loadedCharted hazards or navigational warnings missing from the display
Position offset from GPSDatum mismatch between GPS and chart, or antenna offset not configuredDisplayed position does not match actual position, false confidence near hazards
Grounding alarm not triggeringSafety contour or safety depth set incorrectly for the vessel's draftNo warning before entering shallow water
System freeze or reboot at seaSoftware fault or overloaded processor from excessive chart layersLoss of primary navigation display, must revert to backup

What to look for in a supplier

  • Current type approval certificate matching the software version actually installed.
  • A chart correction and licensing service with proven coverage in the vessel's operating regions.
  • Training documentation that meets the type-specific familiarisation requirement for the exact model installed.
  • Clear upgrade path as IHO data standards and IMO performance standards revise, since chart formats have changed before and will again.

Check the safety contour setting against the vessel's actual draft every time a new route is planned, not just once at commissioning a safety contour left at a default value gives grounding alarms that mean nothing for the ship's real underkeel clearance.

Models

Models in this type.

The best-documented model of each manufacturer first, then the next — 3 of 3 models in ECDIS. Every row links to full specifications, documents and service notes.

Showing only Kelvin Hughes. Show all manufacturers
By manufacturer

Manufacturers.

All 49 manufacturers with models of ECDIS. Names with a manufacturer page open it; the others open a search across the full library.

All manufacturers
Show all 49 manufacturers
Related types

Also in Radar & ECDIS.

The other equipment types in this category.

AIS (Class A)RadarRadar Plot System (ARPA)Radar SystemS-Band Radar (3 GHz)X-Band Radar (9 GHz)
Would you like to know more?

One request. A person reads it and replies by e-mail.

Tell us the manufacturer, the model and what you need — a part, a service call, a second opinion. A person reads every request and replies by e-mail.

No details at hand? A photo of the rating plate or the part is enough — simply attach it to the request.

Frequently asked

Three things people ask first.

Is ECDIS data free?

Yes. Every model page, every guide and every datasheet for this type is readable without an account. An account adds saved searches and requests, nothing is taken away.

My model is missing — what now?

Send us the nameplate. We identify it by hand, add it to the library, and if you need a part or a service, the request is already on our desk.

Can you source a ECDIS part?

Yes. Tell us the manufacturer, the model and what you need — a person reads every request and replies by e-mail.