OceanSphere
Engines

Fire Detection System

critical IMO Required 20 / 20 models (Inspector)
Addressable fire detection and alarm system per SOLAS II-2/7.
8760h
Service Interval

Typical Manufacturers

Consilium Autronica (Xtralis) Apollo Hochiki
Inspector Mode Show All 20 / 20 with inspector value

8 manufacturers · 20 models

Autronica

7
Autronica AutroSafe Fire Detection System
Addressable, integrated with CCTV/PA · Fire Suppression / Detection
Common Failures & Inspection Points
  • Flame detector IR window fouling
  • Cable insulation damage (engine room heat)
  • False alarm from galley detectors
Service: Clean flame detector windows quarterly. Test detectors per manufacturer loop schedule.
Spare Parts: Autronica: Löschmittel und Detektoren-Ersatz per Hersteller. Lead time: 2-4 Wochen.
Autronica AutroSafe BS-420 unverified
Equipment Type
fire_detection_panel
Series
AutroSafe
Model code
BS-420
AutroSafe — addressable fire panel
Autronica AutroSafe BSI-400 unverified
Equipment Type
fire_detection_panel
Series
AutroSafe
Model code
BSI-400
AutroSafe — intelligent panel
Autronica AutroSafe Autrosafe 4 unverified
Equipment Type
fire_detection_panel
Series
AutroSafe
Model code
Autrosafe 4
AutroSafe — integrated safety system
Autronica BD-31 Optical Smoke Detector unverified
Equipment Type
fire_detector
Autronica detector
Autronica BHH-500 Heat Detector unverified
Equipment Type
fire_detector
Autronica detector
Autronica BF-30 Flame Detector unverified
Equipment Type
fire_detector
Autronica detector

Consilium

7
Consilium Consilium Salwico CS3000 Fire Detection
Consilium Salwico CS3000 Fire Detection
Addressable loop, 250+ detectors · Fire Suppression / Detection
Common Failures & Inspection Points
  • Detector contamination (dust/oil mist)
  • Loop communication fault
  • Panel battery ageing
Service: Detector sensitivity test annually per EN 54-14. Panel battery replacement every 4 years.
Spare Parts: Consilium: Löschmittel und Detektoren-Ersatz per Hersteller. Lead time: 2-4 Wochen.
Consilium Salwico CS4000 unverified
Equipment Type
fire_detection_panel
Series
Salwico
Model code
CS4000
Salwico fire detection — addressable panel
Consilium Salwico SW4000 unverified
Equipment Type
fire_detection_panel
Series
Salwico
Model code
SW4000
Salwico fire detection — Salwico conventional panel
Consilium Salwico N4000 unverified
Equipment Type
fire_detection_panel
Series
Salwico
Model code
N4000
Salwico fire detection — networked panel
Consilium Salwico Optical Smoke Detector unverified
Equipment Type
fire_detector
Salwico detector
Consilium Salwico Heat Detector unverified
Equipment Type
fire_detector
Salwico detector
Consilium Salwico Flame Detector (IR/UV) unverified
Equipment Type
fire_detector
Salwico detector

Apollo

1
Apollo Marine XP95 Fire Detection System
Analog addressable, 126 devices per loop · Fire Suppression / Detection
Common Failures & Inspection Points
  • Multi-sensor drift requiring recalibration
  • Base corrosion in high-humidity spaces
  • Isolator module failure
Service: Annual detector sensitivity check. Replace detectors at 8-10 year intervals.
Spare Parts: Apollo: Löschmittel und Detektoren-Ersatz per Hersteller. Lead time: 2-4 Wochen.

Autronica / Xtralis (Norway/Australia)

1
AutroSafe Fire Detection
Full Ship Fire Detection · Fire Detection (Smoke/Heat/Flame/Aspiration)
Voltage: 24V DC
Type
Addressable Fire Detection System + Aspiration System
Size Range
  • AutroSafe 4
  • AutroSafe Interactive
  • VESDA (Aspiration)
Drive Type
Electric (24V DC Loop)
Construction
Control panel, addressable detectors, aspiration detectors, manual call points
Common Failures & Inspection Points
  • Aspiration system pipe blockage from dust
  • Smoke detector false alarms from ER oil mist
  • Loop wiring insulation failure
  • Panel communication bus errors
Service: Aspiration system pipe integrity test annually. Standard detector test annually. Panel battery monthly. Loop test quarterly.
Spare Parts: Autronica (Trondheim, Norway). Lead time: 2-4 weeks.

Consilium Marine / Consilium Safety (Sweden)

1
Consilium Marine / Consilium Safety (Sweden) Salwico Fire Detection System
Salwico Fire Detection System
Full Ship Fire Detection · Fire Detection (Smoke/Heat/Flame)
Voltage: 24V DC
Type
Addressable Fire Detection System (Marine)
Size Range
  • Salwico CS3000
  • Salwico CS5000
  • Salwico MerlinX
Drive Type
Electric (24V DC Loop)
Construction
Control panel, addressable detectors (smoke/heat/flame), manual call points, alarm bells/horns
Common Failures & Inspection Points
  • Smoke detector contamination from engine room dust/oil mist — false alarms
  • Heat detector sensitivity drift from age
  • Loop wiring corrosion from moisture
  • Control panel power supply failure
  • Manual call point mechanism damage
Service: Detector sensitivity test annually. Loop integrity test quarterly. Control panel battery test monthly. False alarm investigation protocol mandatory. Full system test at annual survey.
Spare Parts: Consilium Marine (Gothenburg, Sweden). Lead time: 2-4 weeks. Detectors: keep 10% spare stock onboard.

Hochiki (Japan)

1
Marine Fire Detection System
Full Ship Fire Detection · Fire Detection
Voltage: 24V DC
Type
Addressable Fire Detection System
Size Range
  • Hochiki FIREscape
  • Hochiki ESP
Drive Type
Electric (24V DC Loop)
Construction
Control panel, addressable detectors, manual call points
Common Failures & Inspection Points
  • Detector contamination from dust/oil
  • Loop wiring corrosion
  • Panel component failure
Service: Standard fire detection maintenance per SOLAS.
Spare Parts: Hochiki (Shinagawa, Tokyo). Lead time: 2-4 weeks Asia.

Kongsberg Maritime

1
Fire And Gas Detection System
Typical actions from a Fire and gas detection system
Close watertight doors and fire doors
Certificates
Download certificates

Sika Services

1
Sikacryl®-620 Fire
Coverage area per Hersteller-Datenblatt · Fire Suppression / Detection
Common Failures & Inspection Points
  • Löschmittel-Behälter Druckverlust durch Ventilsitz-Verschleiß
  • Auslöse-Mechanismus Korrosion/Blockierung
  • Detektions-Sensor Kalibrierungsdrift
  • Steuerungselektronik-Ausfall durch Feuchtigkeit
Service: Löschmittel-Behälter Druckprüfung jährlich. Auslöse-Mechanismus Test quartalsweise. Jährliche Inspektion durch Klasse. SOLAS Brandschutz-Übung monatlich.
Spare Parts: Sika Services AG: Löschmittel und Detektoren-Ersatz per Hersteller. Lead time: 2-4 Wochen.