OceanSphere
Engines

Water Mist System (Hi-Fog)

critical IMO Required 6 / 6 models (Inspector)
High-pressure water mist fire suppression system for engine room and accommodation.
4000h
Service Interval

Typical Manufacturers

Marioff Danfoss Semco
Inspector Mode Show All 6 / 6 with inspector value

2 manufacturers · 6 models

Marioff

5
Marioff HI-FOG Water Mist System
Engine room + accommodation zones · Fire Suppression / Detection
Common Failures & Inspection Points
  • High-pressure pump seal failure
  • Spray head nozzle clogging
  • Accumulator pre-charge pressure loss
Service: Pump pressure test quarterly. Nozzle inspection annually. Accumulator pre-charge check every 6 months.
Spare Parts: Marioff: Löschmittel und Detektoren-Ersatz per Hersteller. Lead time: 2-4 Wochen.
Marioff HI-FOG CPU2020 unverified
Equipment Type
water_mist_system
Series
HI-FOG
Model code
CPU2020
HI-FOG water mist — medium capacity pump unit
Marioff HI-FOG CPU2030 unverified
Equipment Type
water_mist_system
Series
HI-FOG
Model code
CPU2030
HI-FOG water mist — high capacity pump unit
Marioff HI-FOG Micro unverified
Equipment Type
water_mist_system
Series
HI-FOG
Model code
Micro
HI-FOG water mist — compact pump unit
Marioff HI-FOG Minifog unverified
Equipment Type
water_mist_system
Series
HI-FOG
Model code
Minifog
HI-FOG water mist — local application

Danfoss Semco

1
Danfoss SemcoSafe Water Mist System
Modular zone coverage · Fire Suppression / Detection
Common Failures & Inspection Points
  • Section valve actuator failure
  • Filter clogging (seawater backup)
  • Control panel communication fault
Service: Section valve operation test monthly. Filter change every 6 months.
Spare Parts: Danfoss Semco: Löschmittel und Detektoren-Ersatz per Hersteller. Lead time: 2-4 Wochen.