Marioff

Marioff HI-FOG Minifog

Marioff Marioff HI-FOG Minifog — Fire Fighting. It is normally installed in protected machinery, cargo or accommodation spaces with pumps, cylinders, valves, piping and release controls as required by the listed system. Its primary purpose is to suppress or extinguish fire using the approved extinguishing medium. Water-mist and CO2 systems differ fundamentally in extinguishing medium and hazards, so release sequence, enclosure conditions and testing must follow the approved fire plan. The model designation identifies the listed configuration, but no additional meaning is inferred from the model code beyond the information supplied in the source record. For exact ratings, dimensions, settings, capacities, materials and variant-specific limits, refer to the manufacturer documentation for the exact figure.

Components & Design

Component data being added…

Technical Data

equipment type water_mist_system
series HI-FOG
model code Minifog

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Nozzle, distribution-pipe or valve blockage reduces delivery to the protected space
Pump, cylinder, pressure or release-system faults prevent the system from reaching normal discharge condition
Solenoid, section-valve or pilot-control faults cause failure to release into the selected zone
Leakage or loss of stored medium causes low-pressure or quantity concerns
Detection, alarm, fan-stop or shutdown interlock faults create an incomplete or unsafe release sequence

Service & Maintenance

Inspect storage or pumps, valves, nozzles, piping, release controls, alarms and shutdown interfaces. Verify access control and protected-space arrangements. Functional tests must follow the approved safety procedure without unintended discharge. Refer to manufacturer, class and statutory documentation for the exact figure for pressure, quantity and acceptance criteria.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

Replacement Parts

Carry approved valve or solenoid parts, pump seals where applicable, release components, alarms, fuses, nozzles and manufacturer-supported service parts.
Equipment Model #67945 · ✓ still in production