OceanSphere
Engines

Inflatable Life Raft (SOLAS-B)

medium 201 models total

A SOLAS-B life raft carries a reduced survival equipment pack compared with SOLAS-A, reflecting the shorter time to rescue expected on the voyages it is approved for — the same inflatable shelter and canopy, but with less on board while survivors wait.

Read more — Inflatable Life Raft (SOLAS-B) explained

What sets a SOLAS-B raft apart from SOLAS-A

Both packs use the same style of inflatable raft — canopy, buoyancy tubes, boarding ramp, righting strap — and both must meet the same LSA Code performance requirements for inflation, capacity and stability in the water. The difference is entirely in what is packed inside. A SOLAS-A pack is built for voyages where rescue could take longer, so it carries a fuller equipment set, including a larger water and food ration, more pyrotechnics, and additional survival aids. A SOLAS-B pack strips this back to a reduced list, reflecting the shorter expected time to rescue on the voyages it is approved for. Choosing SOLAS-B is a decision about the ship's trading area, not a lower-quality raft.

Inflatable life raft cross-section (SOLAS-B)
Cross-section of an inflated SOLAS-B life raft afloat, showing the buoyancy tube, the canopy, the boarding ramp, water ballast pockets beneath the floor, the inflation cylinder, and the painter line with its hydrostatic release unit.

Main components

Buoyancy chamber and canopy

Dual, independently inflatable buoyancy tubes and an insulated canopy that inflates automatically with the raft, giving protection from wind, spray and sun once boarded.

Painter line and hydrostatic release unit

The painter triggers inflation when paid out and, together with a hydrostatic release unit on the cradle, allows the raft to float free and inflate automatically if the ship sinks before it is launched by hand.

Equipment pack (SOLAS-B specific)

A reduced pack against the SOLAS-A list: it still includes essentials such as a bailer, sponge, paddles, repair kit, first aid kit, seasickness tablets, and signalling equipment, but with lower quantities of items like water, food rations and pyrotechnic distress signals than a SOLAS-A pack for the same raft capacity.

Cradle and stowage

Holds the raft ready for launch, typically with a weak link and hydrostatic release arrangement so the raft is not dragged down with a sinking ship.

Selection and sizing

Selection is governed by the ship's certificated area of operation as much as by capacity:

  • Whether the ship's trading pattern qualifies for SOLAS-B equipment under flag and class rules, typically tied to short international voyages or defined coastal areas
  • Rated capacity against the ship's maximum complement, with enough rafts of the fitted capacity to cover the total persons on board plus any required margin
  • Servicing interval and the location of an approved service station on the ship's normal trading route
  • Deck stowage arrangement and launching method, davit-launched or throw-overboard, suited to freeboard and available deck space

Regulations and class

SOLAS Ch. III and the LSA Code set both the raft's performance standards and the exact contents lists for SOLAS-A and SOLAS-B equipment packs. Servicing is required at intervals set by the manufacturer's approval, generally not exceeding twelve months, at a station approved for that raft type, with hydrostatic release units and painter systems checked and renewed on their own separate schedules. Flag administrations decide which ships and voyages may carry SOLAS-B rather than SOLAS-A equipment.

Typical faults

FaultConsequence
Service overdue at the annual station visitRaft certificate lapses, and the ship may not be permitted to sail without a valid raft
Hydrostatic release unit past its expiry dateRaft may not float free and inflate automatically if the ship sinks before manual launch
Cradle corrosion or lashing wrongly re-secured after servicingRaft fails to release cleanly during an actual launch
SOLAS-B raft carried on a voyage that actually requires SOLAS-A equipmentNon-compliance found at port state control, and a genuine shortfall in survival equipment if the raft is ever used

What to look for in a supplier

  • Approval certificate confirming SOLAS-B contents match the current LSA Code list for the raft's capacity
  • Service station network covering the ship's actual trading pattern, not just the home port
  • Clear labelling distinguishing SOLAS-A and SOLAS-B stock where a ship's stores hold both types
  • Documented history of hydrostatic release unit and cradle condition if buying a raft already in service

Confirm which pack, SOLAS-A or SOLAS-B, is actually loaded in each raft rather than assuming from the raft's outer case — the two are visually similar and mixing them up on a voyage that requires SOLAS-A is a real port state control finding.

15 manufacturers · 201 models

Grand Ocean Marine

13 ✓ 13 verified
Grand Ocean Marine ADL-12 Davit Launched Liferaft
ADL-12 Davit Launched Liferaft ✓ verified
Application
Vessels sailing on international voyages (18-50m installation height)
Common Failures & Inspection Points
  • Area: Annual servicing by approved service stations within 12 months (max 17 months in remote areas per SOLAS III/20.8.1)
    Check: Annual servicing by approved service stations within 12 months (max 17 months in remote areas per SOLAS III/20.8.1)
  • Area: Inspection of seams, zippers, and inflatable supports for integrity and material degradation
    Check: Inspection of seams, zippers, and inflatable supports for integrity and material degradation
  • Area: Verification of Hydrostatic Release Unit (HRU) expiry date - must be replaced every 2 years independently
    Check: Verification of Hydrostatic Release Unit (HRU) expiry date - must be replaced every 2 years independently
  • Area: Testing of manual inflation pump for proper operation and valve function
    Check: Testing of manual inflation pump for proper operation and valve function
  • Area: Checking and replacement of worn instruction labels and retroreflective marking/reflector tape
    Check: Checking and replacement of worn instruction labels and retroreflective marking/reflector tape
  • Area: Examination of liferaft for correct markings, capacity certification, and approval certificates
    Check: Examination of liferaft for correct markings, capacity certification, and approval certificates
  • Area: Inspection of container/canister for corrosion, damage, and proper securing mechanisms
    Check: Inspection of container/canister for corrosion, damage, and proper securing mechanisms
  • Area: Documentation review - maintenance records, servicing certificates, and repair logs must be current and signed
    Check: Documentation review - maintenance records, servicing certificates, and repair logs must be current and signed

Typ-universelle Inspektionspunkte fuer Life Rafts (verifiziert, 2026-06).

Grand Ocean Marine ADL-15 Davit Launched Liferaft
ADL-15 Davit Launched Liferaft ✓ verified
Application
Vessels sailing on international voyages (18-50m installation height)
Common Failures & Inspection Points
  • Area: Annual servicing by approved service stations within 12 months (max 17 months in remote areas per SOLAS III/20.8.1)
    Check: Annual servicing by approved service stations within 12 months (max 17 months in remote areas per SOLAS III/20.8.1)
  • Area: Inspection of seams, zippers, and inflatable supports for integrity and material degradation
    Check: Inspection of seams, zippers, and inflatable supports for integrity and material degradation
  • Area: Verification of Hydrostatic Release Unit (HRU) expiry date - must be replaced every 2 years independently
    Check: Verification of Hydrostatic Release Unit (HRU) expiry date - must be replaced every 2 years independently
  • Area: Testing of manual inflation pump for proper operation and valve function
    Check: Testing of manual inflation pump for proper operation and valve function
  • Area: Checking and replacement of worn instruction labels and retroreflective marking/reflector tape
    Check: Checking and replacement of worn instruction labels and retroreflective marking/reflector tape
  • Area: Examination of liferaft for correct markings, capacity certification, and approval certificates
    Check: Examination of liferaft for correct markings, capacity certification, and approval certificates
  • Area: Inspection of container/canister for corrosion, damage, and proper securing mechanisms
    Check: Inspection of container/canister for corrosion, damage, and proper securing mechanisms
  • Area: Documentation review - maintenance records, servicing certificates, and repair logs must be current and signed
    Check: Documentation review - maintenance records, servicing certificates, and repair logs must be current and signed

Typ-universelle Inspektionspunkte fuer Life Rafts (verifiziert, 2026-06).

Grand Ocean Marine ADL-20 Davit Launched Liferaft
ADL-20 Davit Launched Liferaft ✓ verified
Application
Vessels sailing on international voyages (18-50m installation height)
Common Failures & Inspection Points
  • Area: Annual servicing by approved service stations within 12 months (max 17 months in remote areas per SOLAS III/20.8.1)
    Check: Annual servicing by approved service stations within 12 months (max 17 months in remote areas per SOLAS III/20.8.1)
  • Area: Inspection of seams, zippers, and inflatable supports for integrity and material degradation
    Check: Inspection of seams, zippers, and inflatable supports for integrity and material degradation
  • Area: Verification of Hydrostatic Release Unit (HRU) expiry date - must be replaced every 2 years independently
    Check: Verification of Hydrostatic Release Unit (HRU) expiry date - must be replaced every 2 years independently
  • Area: Testing of manual inflation pump for proper operation and valve function
    Check: Testing of manual inflation pump for proper operation and valve function
  • Area: Checking and replacement of worn instruction labels and retroreflective marking/reflector tape
    Check: Checking and replacement of worn instruction labels and retroreflective marking/reflector tape
  • Area: Examination of liferaft for correct markings, capacity certification, and approval certificates
    Check: Examination of liferaft for correct markings, capacity certification, and approval certificates
  • Area: Inspection of container/canister for corrosion, damage, and proper securing mechanisms
    Check: Inspection of container/canister for corrosion, damage, and proper securing mechanisms
  • Area: Documentation review - maintenance records, servicing certificates, and repair logs must be current and signed
    Check: Documentation review - maintenance records, servicing certificates, and repair logs must be current and signed

Typ-universelle Inspektionspunkte fuer Life Rafts (verifiziert, 2026-06).

Grand Ocean Marine ADL-25 Davit Launched Liferaft
ADL-25 Davit Launched Liferaft ✓ verified
Application
Vessels sailing on international voyages (18-50m installation height)
Common Failures & Inspection Points
  • Area: Annual servicing by approved service stations within 12 months (max 17 months in remote areas per SOLAS III/20.8.1)
    Check: Annual servicing by approved service stations within 12 months (max 17 months in remote areas per SOLAS III/20.8.1)
  • Area: Inspection of seams, zippers, and inflatable supports for integrity and material degradation
    Check: Inspection of seams, zippers, and inflatable supports for integrity and material degradation
  • Area: Verification of Hydrostatic Release Unit (HRU) expiry date - must be replaced every 2 years independently
    Check: Verification of Hydrostatic Release Unit (HRU) expiry date - must be replaced every 2 years independently
  • Area: Testing of manual inflation pump for proper operation and valve function
    Check: Testing of manual inflation pump for proper operation and valve function
  • Area: Checking and replacement of worn instruction labels and retroreflective marking/reflector tape
    Check: Checking and replacement of worn instruction labels and retroreflective marking/reflector tape
  • Area: Examination of liferaft for correct markings, capacity certification, and approval certificates
    Check: Examination of liferaft for correct markings, capacity certification, and approval certificates
  • Area: Inspection of container/canister for corrosion, damage, and proper securing mechanisms
    Check: Inspection of container/canister for corrosion, damage, and proper securing mechanisms
  • Area: Documentation review - maintenance records, servicing certificates, and repair logs must be current and signed
    Check: Documentation review - maintenance records, servicing certificates, and repair logs must be current and signed

Typ-universelle Inspektionspunkte fuer Life Rafts (verifiziert, 2026-06).

Grand Ocean Marine Throw Overboard Liferaft 6-person
Throw Overboard Liferaft 6-person ✓ verified
Application
Throw-overboard type for vessels sailing on international voyages
Common Failures & Inspection Points
  • Area: Annual servicing by approved service stations within 12 months (max 17 months in remote areas per SOLAS III/20.8.1)
    Check: Annual servicing by approved service stations within 12 months (max 17 months in remote areas per SOLAS III/20.8.1)
  • Area: Inspection of seams, zippers, and inflatable supports for integrity and material degradation
    Check: Inspection of seams, zippers, and inflatable supports for integrity and material degradation
  • Area: Verification of Hydrostatic Release Unit (HRU) expiry date - must be replaced every 2 years independently
    Check: Verification of Hydrostatic Release Unit (HRU) expiry date - must be replaced every 2 years independently
  • Area: Testing of manual inflation pump for proper operation and valve function
    Check: Testing of manual inflation pump for proper operation and valve function
  • Area: Checking and replacement of worn instruction labels and retroreflective marking/reflector tape
    Check: Checking and replacement of worn instruction labels and retroreflective marking/reflector tape
  • Area: Examination of liferaft for correct markings, capacity certification, and approval certificates
    Check: Examination of liferaft for correct markings, capacity certification, and approval certificates
  • Area: Inspection of container/canister for corrosion, damage, and proper securing mechanisms
    Check: Inspection of container/canister for corrosion, damage, and proper securing mechanisms
  • Area: Documentation review - maintenance records, servicing certificates, and repair logs must be current and signed
    Check: Documentation review - maintenance records, servicing certificates, and repair logs must be current and signed

Typ-universelle Inspektionspunkte fuer Life Rafts (verifiziert, 2026-06).

Grand Ocean Marine Throw Overboard Liferaft 8-person
Throw Overboard Liferaft 8-person ✓ verified
Application
Throw-overboard type for vessels sailing on international voyages
Common Failures & Inspection Points
  • Area: Annual servicing by approved service stations within 12 months (max 17 months in remote areas per SOLAS III/20.8.1)
    Check: Annual servicing by approved service stations within 12 months (max 17 months in remote areas per SOLAS III/20.8.1)
  • Area: Inspection of seams, zippers, and inflatable supports for integrity and material degradation
    Check: Inspection of seams, zippers, and inflatable supports for integrity and material degradation
  • Area: Verification of Hydrostatic Release Unit (HRU) expiry date - must be replaced every 2 years independently
    Check: Verification of Hydrostatic Release Unit (HRU) expiry date - must be replaced every 2 years independently
  • Area: Testing of manual inflation pump for proper operation and valve function
    Check: Testing of manual inflation pump for proper operation and valve function
  • Area: Checking and replacement of worn instruction labels and retroreflective marking/reflector tape
    Check: Checking and replacement of worn instruction labels and retroreflective marking/reflector tape
  • Area: Examination of liferaft for correct markings, capacity certification, and approval certificates
    Check: Examination of liferaft for correct markings, capacity certification, and approval certificates
  • Area: Inspection of container/canister for corrosion, damage, and proper securing mechanisms
    Check: Inspection of container/canister for corrosion, damage, and proper securing mechanisms
  • Area: Documentation review - maintenance records, servicing certificates, and repair logs must be current and signed
    Check: Documentation review - maintenance records, servicing certificates, and repair logs must be current and signed

Typ-universelle Inspektionspunkte fuer Life Rafts (verifiziert, 2026-06).

Grand Ocean Marine Throw Overboard Liferaft 12-person
Throw Overboard Liferaft 12-person ✓ verified
Application
Throw-overboard type for vessels sailing on international voyages
Common Failures & Inspection Points
  • Area: Annual servicing by approved service stations within 12 months (max 17 months in remote areas per SOLAS III/20.8.1)
    Check: Annual servicing by approved service stations within 12 months (max 17 months in remote areas per SOLAS III/20.8.1)
  • Area: Inspection of seams, zippers, and inflatable supports for integrity and material degradation
    Check: Inspection of seams, zippers, and inflatable supports for integrity and material degradation
  • Area: Verification of Hydrostatic Release Unit (HRU) expiry date - must be replaced every 2 years independently
    Check: Verification of Hydrostatic Release Unit (HRU) expiry date - must be replaced every 2 years independently
  • Area: Testing of manual inflation pump for proper operation and valve function
    Check: Testing of manual inflation pump for proper operation and valve function
  • Area: Checking and replacement of worn instruction labels and retroreflective marking/reflector tape
    Check: Checking and replacement of worn instruction labels and retroreflective marking/reflector tape
  • Area: Examination of liferaft for correct markings, capacity certification, and approval certificates
    Check: Examination of liferaft for correct markings, capacity certification, and approval certificates
  • Area: Inspection of container/canister for corrosion, damage, and proper securing mechanisms
    Check: Inspection of container/canister for corrosion, damage, and proper securing mechanisms
  • Area: Documentation review - maintenance records, servicing certificates, and repair logs must be current and signed
    Check: Documentation review - maintenance records, servicing certificates, and repair logs must be current and signed

Typ-universelle Inspektionspunkte fuer Life Rafts (verifiziert, 2026-06).

Grand Ocean Marine Throw Overboard Liferaft 25-person
Throw Overboard Liferaft 25-person ✓ verified
Application
Throw-overboard type for vessels sailing on international voyages
Common Failures & Inspection Points
  • Area: Annual servicing by approved service stations within 12 months (max 17 months in remote areas per SOLAS III/20.8.1)
    Check: Annual servicing by approved service stations within 12 months (max 17 months in remote areas per SOLAS III/20.8.1)
  • Area: Inspection of seams, zippers, and inflatable supports for integrity and material degradation
    Check: Inspection of seams, zippers, and inflatable supports for integrity and material degradation
  • Area: Verification of Hydrostatic Release Unit (HRU) expiry date - must be replaced every 2 years independently
    Check: Verification of Hydrostatic Release Unit (HRU) expiry date - must be replaced every 2 years independently
  • Area: Testing of manual inflation pump for proper operation and valve function
    Check: Testing of manual inflation pump for proper operation and valve function
  • Area: Checking and replacement of worn instruction labels and retroreflective marking/reflector tape
    Check: Checking and replacement of worn instruction labels and retroreflective marking/reflector tape
  • Area: Examination of liferaft for correct markings, capacity certification, and approval certificates
    Check: Examination of liferaft for correct markings, capacity certification, and approval certificates
  • Area: Inspection of container/canister for corrosion, damage, and proper securing mechanisms
    Check: Inspection of container/canister for corrosion, damage, and proper securing mechanisms
  • Area: Documentation review - maintenance records, servicing certificates, and repair logs must be current and signed
    Check: Documentation review - maintenance records, servicing certificates, and repair logs must be current and signed

Typ-universelle Inspektionspunkte fuer Life Rafts (verifiziert, 2026-06).

Grand Ocean Marine YT-4 Leisure Life Raft
YT-4 Leisure Life Raft ✓ verified
Application
Small boats and yachts up to 24 meters
Common Failures & Inspection Points
  • Area: Annual servicing by approved service stations within 12 months (max 17 months in remote areas per SOLAS III/20.8.1)
    Check: Annual servicing by approved service stations within 12 months (max 17 months in remote areas per SOLAS III/20.8.1)
  • Area: Inspection of seams, zippers, and inflatable supports for integrity and material degradation
    Check: Inspection of seams, zippers, and inflatable supports for integrity and material degradation
  • Area: Verification of Hydrostatic Release Unit (HRU) expiry date - must be replaced every 2 years independently
    Check: Verification of Hydrostatic Release Unit (HRU) expiry date - must be replaced every 2 years independently
  • Area: Testing of manual inflation pump for proper operation and valve function
    Check: Testing of manual inflation pump for proper operation and valve function
  • Area: Checking and replacement of worn instruction labels and retroreflective marking/reflector tape
    Check: Checking and replacement of worn instruction labels and retroreflective marking/reflector tape
  • Area: Examination of liferaft for correct markings, capacity certification, and approval certificates
    Check: Examination of liferaft for correct markings, capacity certification, and approval certificates
  • Area: Inspection of container/canister for corrosion, damage, and proper securing mechanisms
    Check: Inspection of container/canister for corrosion, damage, and proper securing mechanisms
  • Area: Documentation review - maintenance records, servicing certificates, and repair logs must be current and signed
    Check: Documentation review - maintenance records, servicing certificates, and repair logs must be current and signed

Typ-universelle Inspektionspunkte fuer Life Rafts (verifiziert, 2026-06).

Grand Ocean Marine YT-6 Leisure Life Raft
YT-6 Leisure Life Raft ✓ verified
Application
Small boats and yachts up to 24 meters
Common Failures & Inspection Points
  • Area: Annual servicing by approved service stations within 12 months (max 17 months in remote areas per SOLAS III/20.8.1)
    Check: Annual servicing by approved service stations within 12 months (max 17 months in remote areas per SOLAS III/20.8.1)
  • Area: Inspection of seams, zippers, and inflatable supports for integrity and material degradation
    Check: Inspection of seams, zippers, and inflatable supports for integrity and material degradation
  • Area: Verification of Hydrostatic Release Unit (HRU) expiry date - must be replaced every 2 years independently
    Check: Verification of Hydrostatic Release Unit (HRU) expiry date - must be replaced every 2 years independently
  • Area: Testing of manual inflation pump for proper operation and valve function
    Check: Testing of manual inflation pump for proper operation and valve function
  • Area: Checking and replacement of worn instruction labels and retroreflective marking/reflector tape
    Check: Checking and replacement of worn instruction labels and retroreflective marking/reflector tape
  • Area: Examination of liferaft for correct markings, capacity certification, and approval certificates
    Check: Examination of liferaft for correct markings, capacity certification, and approval certificates
  • Area: Inspection of container/canister for corrosion, damage, and proper securing mechanisms
    Check: Inspection of container/canister for corrosion, damage, and proper securing mechanisms
  • Area: Documentation review - maintenance records, servicing certificates, and repair logs must be current and signed
    Check: Documentation review - maintenance records, servicing certificates, and repair logs must be current and signed

Typ-universelle Inspektionspunkte fuer Life Rafts (verifiziert, 2026-06).

Grand Ocean Marine YT-12 Leisure Life Raft
YT-12 Leisure Life Raft ✓ verified
Application
Small boats and yachts up to 24 meters
Common Failures & Inspection Points
  • Area: Annual servicing by approved service stations within 12 months (max 17 months in remote areas per SOLAS III/20.8.1)
    Check: Annual servicing by approved service stations within 12 months (max 17 months in remote areas per SOLAS III/20.8.1)
  • Area: Inspection of seams, zippers, and inflatable supports for integrity and material degradation
    Check: Inspection of seams, zippers, and inflatable supports for integrity and material degradation
  • Area: Verification of Hydrostatic Release Unit (HRU) expiry date - must be replaced every 2 years independently
    Check: Verification of Hydrostatic Release Unit (HRU) expiry date - must be replaced every 2 years independently
  • Area: Testing of manual inflation pump for proper operation and valve function
    Check: Testing of manual inflation pump for proper operation and valve function
  • Area: Checking and replacement of worn instruction labels and retroreflective marking/reflector tape
    Check: Checking and replacement of worn instruction labels and retroreflective marking/reflector tape
  • Area: Examination of liferaft for correct markings, capacity certification, and approval certificates
    Check: Examination of liferaft for correct markings, capacity certification, and approval certificates
  • Area: Inspection of container/canister for corrosion, damage, and proper securing mechanisms
    Check: Inspection of container/canister for corrosion, damage, and proper securing mechanisms
  • Area: Documentation review - maintenance records, servicing certificates, and repair logs must be current and signed
    Check: Documentation review - maintenance records, servicing certificates, and repair logs must be current and signed

Typ-universelle Inspektionspunkte fuer Life Rafts (verifiziert, 2026-06).

Grand Ocean Marine Open Reversible Liferaft AOR-6
Open Reversible Liferaft AOR-6 ✓ verified
Application
High-speed vessels on international voyages (HSC pack, 10m installation)
Common Failures & Inspection Points
  • Area: Annual servicing by approved service stations within 12 months (max 17 months in remote areas per SOLAS III/20.8.1)
    Check: Annual servicing by approved service stations within 12 months (max 17 months in remote areas per SOLAS III/20.8.1)
  • Area: Inspection of seams, zippers, and inflatable supports for integrity and material degradation
    Check: Inspection of seams, zippers, and inflatable supports for integrity and material degradation
  • Area: Verification of Hydrostatic Release Unit (HRU) expiry date - must be replaced every 2 years independently
    Check: Verification of Hydrostatic Release Unit (HRU) expiry date - must be replaced every 2 years independently
  • Area: Testing of manual inflation pump for proper operation and valve function
    Check: Testing of manual inflation pump for proper operation and valve function
  • Area: Checking and replacement of worn instruction labels and retroreflective marking/reflector tape
    Check: Checking and replacement of worn instruction labels and retroreflective marking/reflector tape
  • Area: Examination of liferaft for correct markings, capacity certification, and approval certificates
    Check: Examination of liferaft for correct markings, capacity certification, and approval certificates
  • Area: Inspection of container/canister for corrosion, damage, and proper securing mechanisms
    Check: Inspection of container/canister for corrosion, damage, and proper securing mechanisms
  • Area: Documentation review - maintenance records, servicing certificates, and repair logs must be current and signed
    Check: Documentation review - maintenance records, servicing certificates, and repair logs must be current and signed

Typ-universelle Inspektionspunkte fuer Life Rafts (verifiziert, 2026-06).

Grand Ocean Marine Self Righting Life Raft
Self Righting Life Raft ✓ verified
Application
Vessels sailing on international voyages (self-righting capability, 18-50m installation)
Common Failures & Inspection Points
  • Area: Annual servicing by approved service stations within 12 months (max 17 months in remote areas per SOLAS III/20.8.1)
    Check: Annual servicing by approved service stations within 12 months (max 17 months in remote areas per SOLAS III/20.8.1)
  • Area: Inspection of seams, zippers, and inflatable supports for integrity and material degradation
    Check: Inspection of seams, zippers, and inflatable supports for integrity and material degradation
  • Area: Verification of Hydrostatic Release Unit (HRU) expiry date - must be replaced every 2 years independently
    Check: Verification of Hydrostatic Release Unit (HRU) expiry date - must be replaced every 2 years independently
  • Area: Testing of manual inflation pump for proper operation and valve function
    Check: Testing of manual inflation pump for proper operation and valve function
  • Area: Checking and replacement of worn instruction labels and retroreflective marking/reflector tape
    Check: Checking and replacement of worn instruction labels and retroreflective marking/reflector tape
  • Area: Examination of liferaft for correct markings, capacity certification, and approval certificates
    Check: Examination of liferaft for correct markings, capacity certification, and approval certificates
  • Area: Inspection of container/canister for corrosion, damage, and proper securing mechanisms
    Check: Inspection of container/canister for corrosion, damage, and proper securing mechanisms
  • Area: Documentation review - maintenance records, servicing certificates, and repair logs must be current and signed
    Check: Documentation review - maintenance records, servicing certificates, and repair logs must be current and signed

Typ-universelle Inspektionspunkte fuer Life Rafts (verifiziert, 2026-06).

Revere Survival Inc.

10 ✓ 10 verified
Revere Survival Inc. REVERE USCG/SOLAS Low Profile Life Raft, 4-Person B-Pack
REVERE USCG/SOLAS Low Profile Life Raft, 4-Person B-Pack ✓ verified
Application
Commercial marine vessel emergency evacuation
Common Failures & Inspection Points
  • Area: Faserstruktur und Nahtintegrität - Vollständige Inspektion auf Beschädigungen, Risse, Verformungen bei vollständiger Aufblasung
    Check: Faserstruktur und Nahtintegrität - Vollständige Inspektion auf Beschädigungen, Risse, Verformungen bei vollständiger Aufblasung
  • Area: Auftriebskammer-Funktionalität und Drucktest - Prüfung beider Luftkammern auf Dichtheit und Druckabbau
    Check: Auftriebskammer-Funktionalität und Drucktest - Prüfung beider Luftkammern auf Dichtheit und Druckabbau
  • Area: Hydrostatic Release Unit (HRU) Gültigkeit und Funktion - Austausch alle 2 Jahre unabhängig vom Zustand während jeder Inspektion
    Check: Hydrostatic Release Unit (HRU) Gültigkeit und Funktion - Austausch alle 2 Jahre unabhängig vom Zustand während jeder Inspektion
  • Area: Ausrüstungsinventar nach SOLAS-B Packungsliste - Vollständigkeit aller geforderten Rettungsmittel und Notfallausrüstung
    Check: Ausrüstungsinventar nach SOLAS-B Packungsliste - Vollständigkeit aller geforderten Rettungsmittel und Notfallausrüstung
  • Area: Pyrotechnische Mittel - Verfallsdatum prüfen, Austausch aller abgelaufenen Leuchtkörper und Signalraketen
    Check: Pyrotechnische Mittel - Verfallsdatum prüfen, Austausch aller abgelaufenen Leuchtkörper und Signalraketen
  • Area: Aufblassystem - Test der manuellen Handpumpe und automatischen Aufblasanlage
    Check: Aufblassystem - Test der manuellen Handpumpe und automatischen Aufblasanlage
  • Area: Behälter und Cradle Inspektion - Wöchentliches visuelles Check, Verwitterung, Befestigung, Hydrostatic-Release-Vorrichtung
    Check: Behälter und Cradle Inspektion - Wöchentliches visuelles Check, Verwitterung, Befestigung, Hydrostatic-Release-Vorrichtung
  • Area: Trink- und Notproviant - Verfallsdatum prüfen und austauschen, Thermische Schutzausrüstung überprüfen
    Check: Trink- und Notproviant - Verfallsdatum prüfen und austauschen, Thermische Schutzausrüstung überprüfen

Typ-universelle Inspektionspunkte fuer Life Rafts (verifiziert, 2026-06).

Revere Survival Inc. REVERE USCG/SOLAS Low Profile Life Raft, 6-Person B-Pack
REVERE USCG/SOLAS Low Profile Life Raft, 6-Person B-Pack ✓ verified
Application
Commercial marine vessel emergency evacuation
Common Failures & Inspection Points
  • Area: Faserstruktur und Nahtintegrität - Vollständige Inspektion auf Beschädigungen, Risse, Verformungen bei vollständiger Aufblasung
    Check: Faserstruktur und Nahtintegrität - Vollständige Inspektion auf Beschädigungen, Risse, Verformungen bei vollständiger Aufblasung
  • Area: Auftriebskammer-Funktionalität und Drucktest - Prüfung beider Luftkammern auf Dichtheit und Druckabbau
    Check: Auftriebskammer-Funktionalität und Drucktest - Prüfung beider Luftkammern auf Dichtheit und Druckabbau
  • Area: Hydrostatic Release Unit (HRU) Gültigkeit und Funktion - Austausch alle 2 Jahre unabhängig vom Zustand während jeder Inspektion
    Check: Hydrostatic Release Unit (HRU) Gültigkeit und Funktion - Austausch alle 2 Jahre unabhängig vom Zustand während jeder Inspektion
  • Area: Ausrüstungsinventar nach SOLAS-B Packungsliste - Vollständigkeit aller geforderten Rettungsmittel und Notfallausrüstung
    Check: Ausrüstungsinventar nach SOLAS-B Packungsliste - Vollständigkeit aller geforderten Rettungsmittel und Notfallausrüstung
  • Area: Pyrotechnische Mittel - Verfallsdatum prüfen, Austausch aller abgelaufenen Leuchtkörper und Signalraketen
    Check: Pyrotechnische Mittel - Verfallsdatum prüfen, Austausch aller abgelaufenen Leuchtkörper und Signalraketen
  • Area: Aufblassystem - Test der manuellen Handpumpe und automatischen Aufblasanlage
    Check: Aufblassystem - Test der manuellen Handpumpe und automatischen Aufblasanlage
  • Area: Behälter und Cradle Inspektion - Wöchentliches visuelles Check, Verwitterung, Befestigung, Hydrostatic-Release-Vorrichtung
    Check: Behälter und Cradle Inspektion - Wöchentliches visuelles Check, Verwitterung, Befestigung, Hydrostatic-Release-Vorrichtung
  • Area: Trink- und Notproviant - Verfallsdatum prüfen und austauschen, Thermische Schutzausrüstung überprüfen
    Check: Trink- und Notproviant - Verfallsdatum prüfen und austauschen, Thermische Schutzausrüstung überprüfen

Typ-universelle Inspektionspunkte fuer Life Rafts (verifiziert, 2026-06).

Revere Survival Inc. REVERE USCG/SOLAS Low Profile Life Raft, 8-Person B-Pack
REVERE USCG/SOLAS Low Profile Life Raft, 8-Person B-Pack ✓ verified
Application
Commercial marine vessel emergency evacuation
Common Failures & Inspection Points
  • Area: Faserstruktur und Nahtintegrität - Vollständige Inspektion auf Beschädigungen, Risse, Verformungen bei vollständiger Aufblasung
    Check: Faserstruktur und Nahtintegrität - Vollständige Inspektion auf Beschädigungen, Risse, Verformungen bei vollständiger Aufblasung
  • Area: Auftriebskammer-Funktionalität und Drucktest - Prüfung beider Luftkammern auf Dichtheit und Druckabbau
    Check: Auftriebskammer-Funktionalität und Drucktest - Prüfung beider Luftkammern auf Dichtheit und Druckabbau
  • Area: Hydrostatic Release Unit (HRU) Gültigkeit und Funktion - Austausch alle 2 Jahre unabhängig vom Zustand während jeder Inspektion
    Check: Hydrostatic Release Unit (HRU) Gültigkeit und Funktion - Austausch alle 2 Jahre unabhängig vom Zustand während jeder Inspektion
  • Area: Ausrüstungsinventar nach SOLAS-B Packungsliste - Vollständigkeit aller geforderten Rettungsmittel und Notfallausrüstung
    Check: Ausrüstungsinventar nach SOLAS-B Packungsliste - Vollständigkeit aller geforderten Rettungsmittel und Notfallausrüstung
  • Area: Pyrotechnische Mittel - Verfallsdatum prüfen, Austausch aller abgelaufenen Leuchtkörper und Signalraketen
    Check: Pyrotechnische Mittel - Verfallsdatum prüfen, Austausch aller abgelaufenen Leuchtkörper und Signalraketen
  • Area: Aufblassystem - Test der manuellen Handpumpe und automatischen Aufblasanlage
    Check: Aufblassystem - Test der manuellen Handpumpe und automatischen Aufblasanlage
  • Area: Behälter und Cradle Inspektion - Wöchentliches visuelles Check, Verwitterung, Befestigung, Hydrostatic-Release-Vorrichtung
    Check: Behälter und Cradle Inspektion - Wöchentliches visuelles Check, Verwitterung, Befestigung, Hydrostatic-Release-Vorrichtung
  • Area: Trink- und Notproviant - Verfallsdatum prüfen und austauschen, Thermische Schutzausrüstung überprüfen
    Check: Trink- und Notproviant - Verfallsdatum prüfen und austauschen, Thermische Schutzausrüstung überprüfen

Typ-universelle Inspektionspunkte fuer Life Rafts (verifiziert, 2026-06).

Revere Survival Inc. REVERE USCG/SOLAS Round Life Raft, 6-Person B-Pack
REVERE USCG/SOLAS Round Life Raft, 6-Person B-Pack ✓ verified
Application
Commercial marine vessel emergency evacuation
Common Failures & Inspection Points
  • Area: Faserstruktur und Nahtintegrität - Vollständige Inspektion auf Beschädigungen, Risse, Verformungen bei vollständiger Aufblasung
    Check: Faserstruktur und Nahtintegrität - Vollständige Inspektion auf Beschädigungen, Risse, Verformungen bei vollständiger Aufblasung
  • Area: Auftriebskammer-Funktionalität und Drucktest - Prüfung beider Luftkammern auf Dichtheit und Druckabbau
    Check: Auftriebskammer-Funktionalität und Drucktest - Prüfung beider Luftkammern auf Dichtheit und Druckabbau
  • Area: Hydrostatic Release Unit (HRU) Gültigkeit und Funktion - Austausch alle 2 Jahre unabhängig vom Zustand während jeder Inspektion
    Check: Hydrostatic Release Unit (HRU) Gültigkeit und Funktion - Austausch alle 2 Jahre unabhängig vom Zustand während jeder Inspektion
  • Area: Ausrüstungsinventar nach SOLAS-B Packungsliste - Vollständigkeit aller geforderten Rettungsmittel und Notfallausrüstung
    Check: Ausrüstungsinventar nach SOLAS-B Packungsliste - Vollständigkeit aller geforderten Rettungsmittel und Notfallausrüstung
  • Area: Pyrotechnische Mittel - Verfallsdatum prüfen, Austausch aller abgelaufenen Leuchtkörper und Signalraketen
    Check: Pyrotechnische Mittel - Verfallsdatum prüfen, Austausch aller abgelaufenen Leuchtkörper und Signalraketen
  • Area: Aufblassystem - Test der manuellen Handpumpe und automatischen Aufblasanlage
    Check: Aufblassystem - Test der manuellen Handpumpe und automatischen Aufblasanlage
  • Area: Behälter und Cradle Inspektion - Wöchentliches visuelles Check, Verwitterung, Befestigung, Hydrostatic-Release-Vorrichtung
    Check: Behälter und Cradle Inspektion - Wöchentliches visuelles Check, Verwitterung, Befestigung, Hydrostatic-Release-Vorrichtung
  • Area: Trink- und Notproviant - Verfallsdatum prüfen und austauschen, Thermische Schutzausrüstung überprüfen
    Check: Trink- und Notproviant - Verfallsdatum prüfen und austauschen, Thermische Schutzausrüstung überprüfen

Typ-universelle Inspektionspunkte fuer Life Rafts (verifiziert, 2026-06).

Revere Survival Inc. REVERE USCG/SOLAS Round Life Raft, 8-Person B-Pack
REVERE USCG/SOLAS Round Life Raft, 8-Person B-Pack ✓ verified
Application
Commercial marine vessel emergency evacuation
Common Failures & Inspection Points
  • Area: Faserstruktur und Nahtintegrität - Vollständige Inspektion auf Beschädigungen, Risse, Verformungen bei vollständiger Aufblasung
    Check: Faserstruktur und Nahtintegrität - Vollständige Inspektion auf Beschädigungen, Risse, Verformungen bei vollständiger Aufblasung
  • Area: Auftriebskammer-Funktionalität und Drucktest - Prüfung beider Luftkammern auf Dichtheit und Druckabbau
    Check: Auftriebskammer-Funktionalität und Drucktest - Prüfung beider Luftkammern auf Dichtheit und Druckabbau
  • Area: Hydrostatic Release Unit (HRU) Gültigkeit und Funktion - Austausch alle 2 Jahre unabhängig vom Zustand während jeder Inspektion
    Check: Hydrostatic Release Unit (HRU) Gültigkeit und Funktion - Austausch alle 2 Jahre unabhängig vom Zustand während jeder Inspektion
  • Area: Ausrüstungsinventar nach SOLAS-B Packungsliste - Vollständigkeit aller geforderten Rettungsmittel und Notfallausrüstung
    Check: Ausrüstungsinventar nach SOLAS-B Packungsliste - Vollständigkeit aller geforderten Rettungsmittel und Notfallausrüstung
  • Area: Pyrotechnische Mittel - Verfallsdatum prüfen, Austausch aller abgelaufenen Leuchtkörper und Signalraketen
    Check: Pyrotechnische Mittel - Verfallsdatum prüfen, Austausch aller abgelaufenen Leuchtkörper und Signalraketen
  • Area: Aufblassystem - Test der manuellen Handpumpe und automatischen Aufblasanlage
    Check: Aufblassystem - Test der manuellen Handpumpe und automatischen Aufblasanlage
  • Area: Behälter und Cradle Inspektion - Wöchentliches visuelles Check, Verwitterung, Befestigung, Hydrostatic-Release-Vorrichtung
    Check: Behälter und Cradle Inspektion - Wöchentliches visuelles Check, Verwitterung, Befestigung, Hydrostatic-Release-Vorrichtung
  • Area: Trink- und Notproviant - Verfallsdatum prüfen und austauschen, Thermische Schutzausrüstung überprüfen
    Check: Trink- und Notproviant - Verfallsdatum prüfen und austauschen, Thermische Schutzausrüstung überprüfen

Typ-universelle Inspektionspunkte fuer Life Rafts (verifiziert, 2026-06).

Revere Survival Inc. REVERE USCG/SOLAS Round Life Raft, 10-Person B-Pack
REVERE USCG/SOLAS Round Life Raft, 10-Person B-Pack ✓ verified
Application
Commercial marine vessel emergency evacuation
Common Failures & Inspection Points
  • Area: Faserstruktur und Nahtintegrität - Vollständige Inspektion auf Beschädigungen, Risse, Verformungen bei vollständiger Aufblasung
    Check: Faserstruktur und Nahtintegrität - Vollständige Inspektion auf Beschädigungen, Risse, Verformungen bei vollständiger Aufblasung
  • Area: Auftriebskammer-Funktionalität und Drucktest - Prüfung beider Luftkammern auf Dichtheit und Druckabbau
    Check: Auftriebskammer-Funktionalität und Drucktest - Prüfung beider Luftkammern auf Dichtheit und Druckabbau
  • Area: Hydrostatic Release Unit (HRU) Gültigkeit und Funktion - Austausch alle 2 Jahre unabhängig vom Zustand während jeder Inspektion
    Check: Hydrostatic Release Unit (HRU) Gültigkeit und Funktion - Austausch alle 2 Jahre unabhängig vom Zustand während jeder Inspektion
  • Area: Ausrüstungsinventar nach SOLAS-B Packungsliste - Vollständigkeit aller geforderten Rettungsmittel und Notfallausrüstung
    Check: Ausrüstungsinventar nach SOLAS-B Packungsliste - Vollständigkeit aller geforderten Rettungsmittel und Notfallausrüstung
  • Area: Pyrotechnische Mittel - Verfallsdatum prüfen, Austausch aller abgelaufenen Leuchtkörper und Signalraketen
    Check: Pyrotechnische Mittel - Verfallsdatum prüfen, Austausch aller abgelaufenen Leuchtkörper und Signalraketen
  • Area: Aufblassystem - Test der manuellen Handpumpe und automatischen Aufblasanlage
    Check: Aufblassystem - Test der manuellen Handpumpe und automatischen Aufblasanlage
  • Area: Behälter und Cradle Inspektion - Wöchentliches visuelles Check, Verwitterung, Befestigung, Hydrostatic-Release-Vorrichtung
    Check: Behälter und Cradle Inspektion - Wöchentliches visuelles Check, Verwitterung, Befestigung, Hydrostatic-Release-Vorrichtung
  • Area: Trink- und Notproviant - Verfallsdatum prüfen und austauschen, Thermische Schutzausrüstung überprüfen
    Check: Trink- und Notproviant - Verfallsdatum prüfen und austauschen, Thermische Schutzausrüstung überprüfen

Typ-universelle Inspektionspunkte fuer Life Rafts (verifiziert, 2026-06).

Revere Survival Inc. REVERE USCG/SOLAS Round Life Raft, 12-Person B-Pack
REVERE USCG/SOLAS Round Life Raft, 12-Person B-Pack ✓ verified
Application
Commercial marine vessel emergency evacuation
Common Failures & Inspection Points
  • Area: Faserstruktur und Nahtintegrität - Vollständige Inspektion auf Beschädigungen, Risse, Verformungen bei vollständiger Aufblasung
    Check: Faserstruktur und Nahtintegrität - Vollständige Inspektion auf Beschädigungen, Risse, Verformungen bei vollständiger Aufblasung
  • Area: Auftriebskammer-Funktionalität und Drucktest - Prüfung beider Luftkammern auf Dichtheit und Druckabbau
    Check: Auftriebskammer-Funktionalität und Drucktest - Prüfung beider Luftkammern auf Dichtheit und Druckabbau
  • Area: Hydrostatic Release Unit (HRU) Gültigkeit und Funktion - Austausch alle 2 Jahre unabhängig vom Zustand während jeder Inspektion
    Check: Hydrostatic Release Unit (HRU) Gültigkeit und Funktion - Austausch alle 2 Jahre unabhängig vom Zustand während jeder Inspektion
  • Area: Ausrüstungsinventar nach SOLAS-B Packungsliste - Vollständigkeit aller geforderten Rettungsmittel und Notfallausrüstung
    Check: Ausrüstungsinventar nach SOLAS-B Packungsliste - Vollständigkeit aller geforderten Rettungsmittel und Notfallausrüstung
  • Area: Pyrotechnische Mittel - Verfallsdatum prüfen, Austausch aller abgelaufenen Leuchtkörper und Signalraketen
    Check: Pyrotechnische Mittel - Verfallsdatum prüfen, Austausch aller abgelaufenen Leuchtkörper und Signalraketen
  • Area: Aufblassystem - Test der manuellen Handpumpe und automatischen Aufblasanlage
    Check: Aufblassystem - Test der manuellen Handpumpe und automatischen Aufblasanlage
  • Area: Behälter und Cradle Inspektion - Wöchentliches visuelles Check, Verwitterung, Befestigung, Hydrostatic-Release-Vorrichtung
    Check: Behälter und Cradle Inspektion - Wöchentliches visuelles Check, Verwitterung, Befestigung, Hydrostatic-Release-Vorrichtung
  • Area: Trink- und Notproviant - Verfallsdatum prüfen und austauschen, Thermische Schutzausrüstung überprüfen
    Check: Trink- und Notproviant - Verfallsdatum prüfen und austauschen, Thermische Schutzausrüstung überprüfen

Typ-universelle Inspektionspunkte fuer Life Rafts (verifiziert, 2026-06).

Revere Survival Inc. REVERE USCG/SOLAS Round Life Raft, 16-Person B-Pack
REVERE USCG/SOLAS Round Life Raft, 16-Person B-Pack ✓ verified
Application
Commercial marine vessel emergency evacuation
Common Failures & Inspection Points
  • Area: Faserstruktur und Nahtintegrität - Vollständige Inspektion auf Beschädigungen, Risse, Verformungen bei vollständiger Aufblasung
    Check: Faserstruktur und Nahtintegrität - Vollständige Inspektion auf Beschädigungen, Risse, Verformungen bei vollständiger Aufblasung
  • Area: Auftriebskammer-Funktionalität und Drucktest - Prüfung beider Luftkammern auf Dichtheit und Druckabbau
    Check: Auftriebskammer-Funktionalität und Drucktest - Prüfung beider Luftkammern auf Dichtheit und Druckabbau
  • Area: Hydrostatic Release Unit (HRU) Gültigkeit und Funktion - Austausch alle 2 Jahre unabhängig vom Zustand während jeder Inspektion
    Check: Hydrostatic Release Unit (HRU) Gültigkeit und Funktion - Austausch alle 2 Jahre unabhängig vom Zustand während jeder Inspektion
  • Area: Ausrüstungsinventar nach SOLAS-B Packungsliste - Vollständigkeit aller geforderten Rettungsmittel und Notfallausrüstung
    Check: Ausrüstungsinventar nach SOLAS-B Packungsliste - Vollständigkeit aller geforderten Rettungsmittel und Notfallausrüstung
  • Area: Pyrotechnische Mittel - Verfallsdatum prüfen, Austausch aller abgelaufenen Leuchtkörper und Signalraketen
    Check: Pyrotechnische Mittel - Verfallsdatum prüfen, Austausch aller abgelaufenen Leuchtkörper und Signalraketen
  • Area: Aufblassystem - Test der manuellen Handpumpe und automatischen Aufblasanlage
    Check: Aufblassystem - Test der manuellen Handpumpe und automatischen Aufblasanlage
  • Area: Behälter und Cradle Inspektion - Wöchentliches visuelles Check, Verwitterung, Befestigung, Hydrostatic-Release-Vorrichtung
    Check: Behälter und Cradle Inspektion - Wöchentliches visuelles Check, Verwitterung, Befestigung, Hydrostatic-Release-Vorrichtung
  • Area: Trink- und Notproviant - Verfallsdatum prüfen und austauschen, Thermische Schutzausrüstung überprüfen
    Check: Trink- und Notproviant - Verfallsdatum prüfen und austauschen, Thermische Schutzausrüstung überprüfen

Typ-universelle Inspektionspunkte fuer Life Rafts (verifiziert, 2026-06).

Revere Survival Inc. REVERE USCG/SOLAS Round Life Raft, 20-Person B-Pack
REVERE USCG/SOLAS Round Life Raft, 20-Person B-Pack ✓ verified
Application
Commercial marine vessel emergency evacuation
Common Failures & Inspection Points
  • Area: Faserstruktur und Nahtintegrität - Vollständige Inspektion auf Beschädigungen, Risse, Verformungen bei vollständiger Aufblasung
    Check: Faserstruktur und Nahtintegrität - Vollständige Inspektion auf Beschädigungen, Risse, Verformungen bei vollständiger Aufblasung
  • Area: Auftriebskammer-Funktionalität und Drucktest - Prüfung beider Luftkammern auf Dichtheit und Druckabbau
    Check: Auftriebskammer-Funktionalität und Drucktest - Prüfung beider Luftkammern auf Dichtheit und Druckabbau
  • Area: Hydrostatic Release Unit (HRU) Gültigkeit und Funktion - Austausch alle 2 Jahre unabhängig vom Zustand während jeder Inspektion
    Check: Hydrostatic Release Unit (HRU) Gültigkeit und Funktion - Austausch alle 2 Jahre unabhängig vom Zustand während jeder Inspektion
  • Area: Ausrüstungsinventar nach SOLAS-B Packungsliste - Vollständigkeit aller geforderten Rettungsmittel und Notfallausrüstung
    Check: Ausrüstungsinventar nach SOLAS-B Packungsliste - Vollständigkeit aller geforderten Rettungsmittel und Notfallausrüstung
  • Area: Pyrotechnische Mittel - Verfallsdatum prüfen, Austausch aller abgelaufenen Leuchtkörper und Signalraketen
    Check: Pyrotechnische Mittel - Verfallsdatum prüfen, Austausch aller abgelaufenen Leuchtkörper und Signalraketen
  • Area: Aufblassystem - Test der manuellen Handpumpe und automatischen Aufblasanlage
    Check: Aufblassystem - Test der manuellen Handpumpe und automatischen Aufblasanlage
  • Area: Behälter und Cradle Inspektion - Wöchentliches visuelles Check, Verwitterung, Befestigung, Hydrostatic-Release-Vorrichtung
    Check: Behälter und Cradle Inspektion - Wöchentliches visuelles Check, Verwitterung, Befestigung, Hydrostatic-Release-Vorrichtung
  • Area: Trink- und Notproviant - Verfallsdatum prüfen und austauschen, Thermische Schutzausrüstung überprüfen
    Check: Trink- und Notproviant - Verfallsdatum prüfen und austauschen, Thermische Schutzausrüstung überprüfen

Typ-universelle Inspektionspunkte fuer Life Rafts (verifiziert, 2026-06).

Revere Survival Inc. REVERE USCG/SOLAS Round Life Raft, 25-Person B-Pack
REVERE USCG/SOLAS Round Life Raft, 25-Person B-Pack ✓ verified
Application
Commercial marine vessel emergency evacuation
Common Failures & Inspection Points
  • Area: Faserstruktur und Nahtintegrität - Vollständige Inspektion auf Beschädigungen, Risse, Verformungen bei vollständiger Aufblasung
    Check: Faserstruktur und Nahtintegrität - Vollständige Inspektion auf Beschädigungen, Risse, Verformungen bei vollständiger Aufblasung
  • Area: Auftriebskammer-Funktionalität und Drucktest - Prüfung beider Luftkammern auf Dichtheit und Druckabbau
    Check: Auftriebskammer-Funktionalität und Drucktest - Prüfung beider Luftkammern auf Dichtheit und Druckabbau
  • Area: Hydrostatic Release Unit (HRU) Gültigkeit und Funktion - Austausch alle 2 Jahre unabhängig vom Zustand während jeder Inspektion
    Check: Hydrostatic Release Unit (HRU) Gültigkeit und Funktion - Austausch alle 2 Jahre unabhängig vom Zustand während jeder Inspektion
  • Area: Ausrüstungsinventar nach SOLAS-B Packungsliste - Vollständigkeit aller geforderten Rettungsmittel und Notfallausrüstung
    Check: Ausrüstungsinventar nach SOLAS-B Packungsliste - Vollständigkeit aller geforderten Rettungsmittel und Notfallausrüstung
  • Area: Pyrotechnische Mittel - Verfallsdatum prüfen, Austausch aller abgelaufenen Leuchtkörper und Signalraketen
    Check: Pyrotechnische Mittel - Verfallsdatum prüfen, Austausch aller abgelaufenen Leuchtkörper und Signalraketen
  • Area: Aufblassystem - Test der manuellen Handpumpe und automatischen Aufblasanlage
    Check: Aufblassystem - Test der manuellen Handpumpe und automatischen Aufblasanlage
  • Area: Behälter und Cradle Inspektion - Wöchentliches visuelles Check, Verwitterung, Befestigung, Hydrostatic-Release-Vorrichtung
    Check: Behälter und Cradle Inspektion - Wöchentliches visuelles Check, Verwitterung, Befestigung, Hydrostatic-Release-Vorrichtung
  • Area: Trink- und Notproviant - Verfallsdatum prüfen und austauschen, Thermische Schutzausrüstung überprüfen
    Check: Trink- und Notproviant - Verfallsdatum prüfen und austauschen, Thermische Schutzausrüstung überprüfen

Typ-universelle Inspektionspunkte fuer Life Rafts (verifiziert, 2026-06).

Deyuan Marine Fitting Co., Ltd

9 ✓ 9 verified
Deyuan Marine Fitting Co., Ltd ASR Type (Self-Righting Inflatable Life Raft) - 100 Person
ASR Type (Self-Righting Inflatable Life Raft) - 100 Person ✓ verified
Application
Commercial ocean-going vessels, international voyages
Common Failures & Inspection Points
  • Area: Visuelle Inspektion des Rumpfs und der Kammern auf Verschlei, Risse, Beschaedigungen und Verfaerbungen
    Check: Visuelle Inspektion des Rumpfs und der Kammern auf Verschlei, Risse, Beschaedigungen und Verfaerbungen
  • Area: Kontrolle aller Ventile, Relie und Manometer auf Funktionsfaehigkeit und dichte
    Check: Kontrolle aller Ventile, Relie und Manometer auf Funktionsfaehigkeit und dichte
  • Area: Pruefung der Rettungsausruestung (Rettungsleinen, Messer, Angelausruestung, Signalbehoerde, Erste-Hilfe-Paket)
    Check: Pruefung der Rettungsausruestung (Rettungsleinen, Messer, Angelausruestung, Signalbehoerde, Erste-Hilfe-Paket)
  • Area: Ueberpruefung der Haltegurte und Befestigungspunkte auf Verschleiss und Beschaedigungen
    Check: Ueberpruefung der Haltegurte und Befestigungspunkte auf Verschleiss und Beschaedigungen
  • Area: Kontrolle der Dichtheit durch Druck- und Lecktests
    Check: Kontrolle der Dichtheit durch Druck- und Lecktests
  • Area: Ueberprueung des Bezugssystems (Vormann, Anker) auf Verschleiss und Korrosion
    Check: Ueberprueung des Bezugssystems (Vormann, Anker) auf Verschleiss und Korrosion
  • Area: Inspektion des Baldachins (Markise) auf Staendigkeit, Teile und Befestigung
    Check: Inspektion des Baldachins (Markise) auf Staendigkeit, Teile und Befestigung
  • Area: Ueberprueung der Gass-Inflationszylinder auf Ausloesung, Druck und Verfallsdatum
    Check: Ueberprueung der Gass-Inflationszylinder auf Ausloesung, Druck und Verfallsdatum

Typ-universelle Inspektionspunkte fuer Life Rafts (verifiziert, 2026-06).

Deyuan Marine Fitting Co., Ltd HSR-Y-12
HSR-Y-12 ✓ verified
Application
Marine fishing boats and commercial vessels
Common Failures & Inspection Points
  • Area: Visuelle Inspektion des Rumpfs und der Kammern auf Verschlei, Risse, Beschaedigungen und Verfaerbungen
    Check: Visuelle Inspektion des Rumpfs und der Kammern auf Verschlei, Risse, Beschaedigungen und Verfaerbungen
  • Area: Kontrolle aller Ventile, Relie und Manometer auf Funktionsfaehigkeit und dichte
    Check: Kontrolle aller Ventile, Relie und Manometer auf Funktionsfaehigkeit und dichte
  • Area: Pruefung der Rettungsausruestung (Rettungsleinen, Messer, Angelausruestung, Signalbehoerde, Erste-Hilfe-Paket)
    Check: Pruefung der Rettungsausruestung (Rettungsleinen, Messer, Angelausruestung, Signalbehoerde, Erste-Hilfe-Paket)
  • Area: Ueberpruefung der Haltegurte und Befestigungspunkte auf Verschleiss und Beschaedigungen
    Check: Ueberpruefung der Haltegurte und Befestigungspunkte auf Verschleiss und Beschaedigungen
  • Area: Kontrolle der Dichtheit durch Druck- und Lecktests
    Check: Kontrolle der Dichtheit durch Druck- und Lecktests
  • Area: Ueberprueung des Bezugssystems (Vormann, Anker) auf Verschleiss und Korrosion
    Check: Ueberprueung des Bezugssystems (Vormann, Anker) auf Verschleiss und Korrosion
  • Area: Inspektion des Baldachins (Markise) auf Staendigkeit, Teile und Befestigung
    Check: Inspektion des Baldachins (Markise) auf Staendigkeit, Teile und Befestigung
  • Area: Ueberprueung der Gass-Inflationszylinder auf Ausloesung, Druck und Verfallsdatum
    Check: Ueberprueung der Gass-Inflationszylinder auf Ausloesung, Druck und Verfallsdatum

Typ-universelle Inspektionspunkte fuer Life Rafts (verifiziert, 2026-06).

Deyuan Marine Fitting Co., Ltd ADL-15 (SOLAS Standard Davit-Launched Type)
ADL-15 (SOLAS Standard Davit-Launched Type) ✓ verified
Application
Commercial vessels requiring davit-launch deployment
Common Failures & Inspection Points
  • Area: Visuelle Inspektion des Rumpfs und der Kammern auf Verschlei, Risse, Beschaedigungen und Verfaerbungen
    Check: Visuelle Inspektion des Rumpfs und der Kammern auf Verschlei, Risse, Beschaedigungen und Verfaerbungen
  • Area: Kontrolle aller Ventile, Relie und Manometer auf Funktionsfaehigkeit und dichte
    Check: Kontrolle aller Ventile, Relie und Manometer auf Funktionsfaehigkeit und dichte
  • Area: Pruefung der Rettungsausruestung (Rettungsleinen, Messer, Angelausruestung, Signalbehoerde, Erste-Hilfe-Paket)
    Check: Pruefung der Rettungsausruestung (Rettungsleinen, Messer, Angelausruestung, Signalbehoerde, Erste-Hilfe-Paket)
  • Area: Ueberpruefung der Haltegurte und Befestigungspunkte auf Verschleiss und Beschaedigungen
    Check: Ueberpruefung der Haltegurte und Befestigungspunkte auf Verschleiss und Beschaedigungen
  • Area: Kontrolle der Dichtheit durch Druck- und Lecktests
    Check: Kontrolle der Dichtheit durch Druck- und Lecktests
  • Area: Ueberprueung des Bezugssystems (Vormann, Anker) auf Verschleiss und Korrosion
    Check: Ueberprueung des Bezugssystems (Vormann, Anker) auf Verschleiss und Korrosion
  • Area: Inspektion des Baldachins (Markise) auf Staendigkeit, Teile und Befestigung
    Check: Inspektion des Baldachins (Markise) auf Staendigkeit, Teile und Befestigung
  • Area: Ueberprueung der Gass-Inflationszylinder auf Ausloesung, Druck und Verfallsdatum
    Check: Ueberprueung der Gass-Inflationszylinder auf Ausloesung, Druck und Verfallsdatum

Typ-universelle Inspektionspunkte fuer Life Rafts (verifiziert, 2026-06).

Deyuan Marine Fitting Co., Ltd HSR-YJ-6 (Throw-Overboard Type)
HSR-YJ-6 (Throw-Overboard Type) ✓ verified
Application
Marine vessels, international voyages
Common Failures & Inspection Points
  • Area: Visuelle Inspektion des Rumpfs und der Kammern auf Verschlei, Risse, Beschaedigungen und Verfaerbungen
    Check: Visuelle Inspektion des Rumpfs und der Kammern auf Verschlei, Risse, Beschaedigungen und Verfaerbungen
  • Area: Kontrolle aller Ventile, Relie und Manometer auf Funktionsfaehigkeit und dichte
    Check: Kontrolle aller Ventile, Relie und Manometer auf Funktionsfaehigkeit und dichte
  • Area: Pruefung der Rettungsausruestung (Rettungsleinen, Messer, Angelausruestung, Signalbehoerde, Erste-Hilfe-Paket)
    Check: Pruefung der Rettungsausruestung (Rettungsleinen, Messer, Angelausruestung, Signalbehoerde, Erste-Hilfe-Paket)
  • Area: Ueberpruefung der Haltegurte und Befestigungspunkte auf Verschleiss und Beschaedigungen
    Check: Ueberpruefung der Haltegurte und Befestigungspunkte auf Verschleiss und Beschaedigungen
  • Area: Kontrolle der Dichtheit durch Druck- und Lecktests
    Check: Kontrolle der Dichtheit durch Druck- und Lecktests
  • Area: Ueberprueung des Bezugssystems (Vormann, Anker) auf Verschleiss und Korrosion
    Check: Ueberprueung des Bezugssystems (Vormann, Anker) auf Verschleiss und Korrosion
  • Area: Inspektion des Baldachins (Markise) auf Staendigkeit, Teile und Befestigung
    Check: Inspektion des Baldachins (Markise) auf Staendigkeit, Teile und Befestigung
  • Area: Ueberprueung der Gass-Inflationszylinder auf Ausloesung, Druck und Verfallsdatum
    Check: Ueberprueung der Gass-Inflationszylinder auf Ausloesung, Druck und Verfallsdatum

Typ-universelle Inspektionspunkte fuer Life Rafts (verifiziert, 2026-06).

Deyuan Marine Fitting Co., Ltd ATOB-30 (Throw-Over Type)
ATOB-30 (Throw-Over Type) ✓ verified
Application
Commercial ocean-going vessels
Common Failures & Inspection Points
  • Area: Visuelle Inspektion des Rumpfs und der Kammern auf Verschlei, Risse, Beschaedigungen und Verfaerbungen
    Check: Visuelle Inspektion des Rumpfs und der Kammern auf Verschlei, Risse, Beschaedigungen und Verfaerbungen
  • Area: Kontrolle aller Ventile, Relie und Manometer auf Funktionsfaehigkeit und dichte
    Check: Kontrolle aller Ventile, Relie und Manometer auf Funktionsfaehigkeit und dichte
  • Area: Pruefung der Rettungsausruestung (Rettungsleinen, Messer, Angelausruestung, Signalbehoerde, Erste-Hilfe-Paket)
    Check: Pruefung der Rettungsausruestung (Rettungsleinen, Messer, Angelausruestung, Signalbehoerde, Erste-Hilfe-Paket)
  • Area: Ueberpruefung der Haltegurte und Befestigungspunkte auf Verschleiss und Beschaedigungen
    Check: Ueberpruefung der Haltegurte und Befestigungspunkte auf Verschleiss und Beschaedigungen
  • Area: Kontrolle der Dichtheit durch Druck- und Lecktests
    Check: Kontrolle der Dichtheit durch Druck- und Lecktests
  • Area: Ueberprueung des Bezugssystems (Vormann, Anker) auf Verschleiss und Korrosion
    Check: Ueberprueung des Bezugssystems (Vormann, Anker) auf Verschleiss und Korrosion
  • Area: Inspektion des Baldachins (Markise) auf Staendigkeit, Teile und Befestigung
    Check: Inspektion des Baldachins (Markise) auf Staendigkeit, Teile und Befestigung
  • Area: Ueberprueung der Gass-Inflationszylinder auf Ausloesung, Druck und Verfallsdatum
    Check: Ueberprueung der Gass-Inflationszylinder auf Ausloesung, Druck und Verfallsdatum

Typ-universelle Inspektionspunkte fuer Life Rafts (verifiziert, 2026-06).

Deyuan Marine Fitting Co., Ltd ATOB-35 (Throw-Over Type)
ATOB-35 (Throw-Over Type) ✓ verified
Application
Commercial ocean-going vessels
Common Failures & Inspection Points
  • Area: Visuelle Inspektion des Rumpfs und der Kammern auf Verschlei, Risse, Beschaedigungen und Verfaerbungen
    Check: Visuelle Inspektion des Rumpfs und der Kammern auf Verschlei, Risse, Beschaedigungen und Verfaerbungen
  • Area: Kontrolle aller Ventile, Relie und Manometer auf Funktionsfaehigkeit und dichte
    Check: Kontrolle aller Ventile, Relie und Manometer auf Funktionsfaehigkeit und dichte
  • Area: Pruefung der Rettungsausruestung (Rettungsleinen, Messer, Angelausruestung, Signalbehoerde, Erste-Hilfe-Paket)
    Check: Pruefung der Rettungsausruestung (Rettungsleinen, Messer, Angelausruestung, Signalbehoerde, Erste-Hilfe-Paket)
  • Area: Ueberpruefung der Haltegurte und Befestigungspunkte auf Verschleiss und Beschaedigungen
    Check: Ueberpruefung der Haltegurte und Befestigungspunkte auf Verschleiss und Beschaedigungen
  • Area: Kontrolle der Dichtheit durch Druck- und Lecktests
    Check: Kontrolle der Dichtheit durch Druck- und Lecktests
  • Area: Ueberprueung des Bezugssystems (Vormann, Anker) auf Verschleiss und Korrosion
    Check: Ueberprueung des Bezugssystems (Vormann, Anker) auf Verschleiss und Korrosion
  • Area: Inspektion des Baldachins (Markise) auf Staendigkeit, Teile und Befestigung
    Check: Inspektion des Baldachins (Markise) auf Staendigkeit, Teile und Befestigung
  • Area: Ueberprueung der Gass-Inflationszylinder auf Ausloesung, Druck und Verfallsdatum
    Check: Ueberprueung der Gass-Inflationszylinder auf Ausloesung, Druck und Verfallsdatum

Typ-universelle Inspektionspunkte fuer Life Rafts (verifiziert, 2026-06).

Deyuan Marine Fitting Co., Ltd ADL-20 (ABS Offshore Davit-Launching Type)
ADL-20 (ABS Offshore Davit-Launching Type) ✓ verified
Application
International voyage commercial vessels
Common Failures & Inspection Points
  • Area: Visuelle Inspektion des Rumpfs und der Kammern auf Verschlei, Risse, Beschaedigungen und Verfaerbungen
    Check: Visuelle Inspektion des Rumpfs und der Kammern auf Verschlei, Risse, Beschaedigungen und Verfaerbungen
  • Area: Kontrolle aller Ventile, Relie und Manometer auf Funktionsfaehigkeit und dichte
    Check: Kontrolle aller Ventile, Relie und Manometer auf Funktionsfaehigkeit und dichte
  • Area: Pruefung der Rettungsausruestung (Rettungsleinen, Messer, Angelausruestung, Signalbehoerde, Erste-Hilfe-Paket)
    Check: Pruefung der Rettungsausruestung (Rettungsleinen, Messer, Angelausruestung, Signalbehoerde, Erste-Hilfe-Paket)
  • Area: Ueberpruefung der Haltegurte und Befestigungspunkte auf Verschleiss und Beschaedigungen
    Check: Ueberpruefung der Haltegurte und Befestigungspunkte auf Verschleiss und Beschaedigungen
  • Area: Kontrolle der Dichtheit durch Druck- und Lecktests
    Check: Kontrolle der Dichtheit durch Druck- und Lecktests
  • Area: Ueberprueung des Bezugssystems (Vormann, Anker) auf Verschleiss und Korrosion
    Check: Ueberprueung des Bezugssystems (Vormann, Anker) auf Verschleiss und Korrosion
  • Area: Inspektion des Baldachins (Markise) auf Staendigkeit, Teile und Befestigung
    Check: Inspektion des Baldachins (Markise) auf Staendigkeit, Teile und Befestigung
  • Area: Ueberprueung der Gass-Inflationszylinder auf Ausloesung, Druck und Verfallsdatum
    Check: Ueberprueung der Gass-Inflationszylinder auf Ausloesung, Druck und Verfallsdatum

Typ-universelle Inspektionspunkte fuer Life Rafts (verifiziert, 2026-06).

Deyuan Marine Fitting Co., Ltd HSR-Y-20
HSR-Y-20 ✓ verified
Application
Fishing boat vessels
Common Failures & Inspection Points
  • Area: Visuelle Inspektion des Rumpfs und der Kammern auf Verschlei, Risse, Beschaedigungen und Verfaerbungen
    Check: Visuelle Inspektion des Rumpfs und der Kammern auf Verschlei, Risse, Beschaedigungen und Verfaerbungen
  • Area: Kontrolle aller Ventile, Relie und Manometer auf Funktionsfaehigkeit und dichte
    Check: Kontrolle aller Ventile, Relie und Manometer auf Funktionsfaehigkeit und dichte
  • Area: Pruefung der Rettungsausruestung (Rettungsleinen, Messer, Angelausruestung, Signalbehoerde, Erste-Hilfe-Paket)
    Check: Pruefung der Rettungsausruestung (Rettungsleinen, Messer, Angelausruestung, Signalbehoerde, Erste-Hilfe-Paket)
  • Area: Ueberpruefung der Haltegurte und Befestigungspunkte auf Verschleiss und Beschaedigungen
    Check: Ueberpruefung der Haltegurte und Befestigungspunkte auf Verschleiss und Beschaedigungen
  • Area: Kontrolle der Dichtheit durch Druck- und Lecktests
    Check: Kontrolle der Dichtheit durch Druck- und Lecktests
  • Area: Ueberprueung des Bezugssystems (Vormann, Anker) auf Verschleiss und Korrosion
    Check: Ueberprueung des Bezugssystems (Vormann, Anker) auf Verschleiss und Korrosion
  • Area: Inspektion des Baldachins (Markise) auf Staendigkeit, Teile und Befestigung
    Check: Inspektion des Baldachins (Markise) auf Staendigkeit, Teile und Befestigung
  • Area: Ueberprueung der Gass-Inflationszylinder auf Ausloesung, Druck und Verfallsdatum
    Check: Ueberprueung der Gass-Inflationszylinder auf Ausloesung, Druck und Verfallsdatum

Typ-universelle Inspektionspunkte fuer Life Rafts (verifiziert, 2026-06).

Deyuan Marine Fitting Co., Ltd ATOB-16 (Throw-Overboard Type)
ATOB-16 (Throw-Overboard Type) ✓ verified
Application
Commercial vessels, international voyages
Common Failures & Inspection Points
  • Area: Visuelle Inspektion des Rumpfs und der Kammern auf Verschlei, Risse, Beschaedigungen und Verfaerbungen
    Check: Visuelle Inspektion des Rumpfs und der Kammern auf Verschlei, Risse, Beschaedigungen und Verfaerbungen
  • Area: Kontrolle aller Ventile, Relie und Manometer auf Funktionsfaehigkeit und dichte
    Check: Kontrolle aller Ventile, Relie und Manometer auf Funktionsfaehigkeit und dichte
  • Area: Pruefung der Rettungsausruestung (Rettungsleinen, Messer, Angelausruestung, Signalbehoerde, Erste-Hilfe-Paket)
    Check: Pruefung der Rettungsausruestung (Rettungsleinen, Messer, Angelausruestung, Signalbehoerde, Erste-Hilfe-Paket)
  • Area: Ueberpruefung der Haltegurte und Befestigungspunkte auf Verschleiss und Beschaedigungen
    Check: Ueberpruefung der Haltegurte und Befestigungspunkte auf Verschleiss und Beschaedigungen
  • Area: Kontrolle der Dichtheit durch Druck- und Lecktests
    Check: Kontrolle der Dichtheit durch Druck- und Lecktests
  • Area: Ueberprueung des Bezugssystems (Vormann, Anker) auf Verschleiss und Korrosion
    Check: Ueberprueung des Bezugssystems (Vormann, Anker) auf Verschleiss und Korrosion
  • Area: Inspektion des Baldachins (Markise) auf Staendigkeit, Teile und Befestigung
    Check: Inspektion des Baldachins (Markise) auf Staendigkeit, Teile und Befestigung
  • Area: Ueberprueung der Gass-Inflationszylinder auf Ausloesung, Druck und Verfallsdatum
    Check: Ueberprueung der Gass-Inflationszylinder auf Ausloesung, Druck und Verfallsdatum

Typ-universelle Inspektionspunkte fuer Life Rafts (verifiziert, 2026-06).

Matchau

8 ✓ 8 verified
Matchau MMR-A6
MMR-A6 ✓ verified
Application
Throw Overboard SOLAS Inflatable Life Raft
Common Failures & Inspection Points
  • Area: Visual hull and seam integrity inspection for damage, punctures, or delamination
    Check: Visual hull and seam integrity inspection for damage, punctures, or delamination
  • Area: Air pressure testing and inflation system valve functionality verification
    Check: Air pressure testing and inflation system valve functionality verification
  • Area: Emergency equipment pack contents shelf-life and completeness inspection (first aid kit, signaling flares, sea anchors, fishing kits)
    Check: Emergency equipment pack contents shelf-life and completeness inspection (first aid kit, signaling flares, sea anchors, fishing kits)
  • Area: Canopy and tarpaulin condition, UV damage assessment, and securing system functionality
    Check: Canopy and tarpaulin condition, UV damage assessment, and securing system functionality
  • Area: Sea anchors, painter lines, and boarding ladders structural integrity and attachment points
    Check: Sea anchors, painter lines, and boarding ladders structural integrity and attachment points
  • Area: Annual hydrostatic release unit (HRU) inspection and certification verification
    Check: Annual hydrostatic release unit (HRU) inspection and certification verification
  • Area: Five-year certified maintenance and recertification compliance documentation review
    Check: Five-year certified maintenance and recertification compliance documentation review
  • Area: Container or cradle condition and securing mechanisms for deployment readiness
    Check: Container or cradle condition and securing mechanisms for deployment readiness

Typ-universelle Inspektionspunkte fuer Life Rafts (verifiziert, 2026-06).

Matchau MMR-A10
MMR-A10 ✓ verified
Application
Throw Overboard SOLAS Inflatable Life Raft
Common Failures & Inspection Points
  • Area: Visual hull and seam integrity inspection for damage, punctures, or delamination
    Check: Visual hull and seam integrity inspection for damage, punctures, or delamination
  • Area: Air pressure testing and inflation system valve functionality verification
    Check: Air pressure testing and inflation system valve functionality verification
  • Area: Emergency equipment pack contents shelf-life and completeness inspection (first aid kit, signaling flares, sea anchors, fishing kits)
    Check: Emergency equipment pack contents shelf-life and completeness inspection (first aid kit, signaling flares, sea anchors, fishing kits)
  • Area: Canopy and tarpaulin condition, UV damage assessment, and securing system functionality
    Check: Canopy and tarpaulin condition, UV damage assessment, and securing system functionality
  • Area: Sea anchors, painter lines, and boarding ladders structural integrity and attachment points
    Check: Sea anchors, painter lines, and boarding ladders structural integrity and attachment points
  • Area: Annual hydrostatic release unit (HRU) inspection and certification verification
    Check: Annual hydrostatic release unit (HRU) inspection and certification verification
  • Area: Five-year certified maintenance and recertification compliance documentation review
    Check: Five-year certified maintenance and recertification compliance documentation review
  • Area: Container or cradle condition and securing mechanisms for deployment readiness
    Check: Container or cradle condition and securing mechanisms for deployment readiness

Typ-universelle Inspektionspunkte fuer Life Rafts (verifiziert, 2026-06).

Matchau MMR-A15
MMR-A15 ✓ verified
Application
Throw Overboard SOLAS Inflatable Life Raft
Common Failures & Inspection Points
  • Area: Visual hull and seam integrity inspection for damage, punctures, or delamination
    Check: Visual hull and seam integrity inspection for damage, punctures, or delamination
  • Area: Air pressure testing and inflation system valve functionality verification
    Check: Air pressure testing and inflation system valve functionality verification
  • Area: Emergency equipment pack contents shelf-life and completeness inspection (first aid kit, signaling flares, sea anchors, fishing kits)
    Check: Emergency equipment pack contents shelf-life and completeness inspection (first aid kit, signaling flares, sea anchors, fishing kits)
  • Area: Canopy and tarpaulin condition, UV damage assessment, and securing system functionality
    Check: Canopy and tarpaulin condition, UV damage assessment, and securing system functionality
  • Area: Sea anchors, painter lines, and boarding ladders structural integrity and attachment points
    Check: Sea anchors, painter lines, and boarding ladders structural integrity and attachment points
  • Area: Annual hydrostatic release unit (HRU) inspection and certification verification
    Check: Annual hydrostatic release unit (HRU) inspection and certification verification
  • Area: Five-year certified maintenance and recertification compliance documentation review
    Check: Five-year certified maintenance and recertification compliance documentation review
  • Area: Container or cradle condition and securing mechanisms for deployment readiness
    Check: Container or cradle condition and securing mechanisms for deployment readiness

Typ-universelle Inspektionspunkte fuer Life Rafts (verifiziert, 2026-06).

Matchau MMR-A25
MMR-A25 ✓ verified
Application
Throw Overboard SOLAS Inflatable Life Raft
Common Failures & Inspection Points
  • Area: Visual hull and seam integrity inspection for damage, punctures, or delamination
    Check: Visual hull and seam integrity inspection for damage, punctures, or delamination
  • Area: Air pressure testing and inflation system valve functionality verification
    Check: Air pressure testing and inflation system valve functionality verification
  • Area: Emergency equipment pack contents shelf-life and completeness inspection (first aid kit, signaling flares, sea anchors, fishing kits)
    Check: Emergency equipment pack contents shelf-life and completeness inspection (first aid kit, signaling flares, sea anchors, fishing kits)
  • Area: Canopy and tarpaulin condition, UV damage assessment, and securing system functionality
    Check: Canopy and tarpaulin condition, UV damage assessment, and securing system functionality
  • Area: Sea anchors, painter lines, and boarding ladders structural integrity and attachment points
    Check: Sea anchors, painter lines, and boarding ladders structural integrity and attachment points
  • Area: Annual hydrostatic release unit (HRU) inspection and certification verification
    Check: Annual hydrostatic release unit (HRU) inspection and certification verification
  • Area: Five-year certified maintenance and recertification compliance documentation review
    Check: Five-year certified maintenance and recertification compliance documentation review
  • Area: Container or cradle condition and securing mechanisms for deployment readiness
    Check: Container or cradle condition and securing mechanisms for deployment readiness

Typ-universelle Inspektionspunkte fuer Life Rafts (verifiziert, 2026-06).

Matchau MSC-A6
MSC-A6 ✓ verified
Application
A Pack Container Packing Throw Over Board Inflatable Life Raft
Common Failures & Inspection Points
  • Area: Visual hull and seam integrity inspection for damage, punctures, or delamination
    Check: Visual hull and seam integrity inspection for damage, punctures, or delamination
  • Area: Air pressure testing and inflation system valve functionality verification
    Check: Air pressure testing and inflation system valve functionality verification
  • Area: Emergency equipment pack contents shelf-life and completeness inspection (first aid kit, signaling flares, sea anchors, fishing kits)
    Check: Emergency equipment pack contents shelf-life and completeness inspection (first aid kit, signaling flares, sea anchors, fishing kits)
  • Area: Canopy and tarpaulin condition, UV damage assessment, and securing system functionality
    Check: Canopy and tarpaulin condition, UV damage assessment, and securing system functionality
  • Area: Sea anchors, painter lines, and boarding ladders structural integrity and attachment points
    Check: Sea anchors, painter lines, and boarding ladders structural integrity and attachment points
  • Area: Annual hydrostatic release unit (HRU) inspection and certification verification
    Check: Annual hydrostatic release unit (HRU) inspection and certification verification
  • Area: Five-year certified maintenance and recertification compliance documentation review
    Check: Five-year certified maintenance and recertification compliance documentation review
  • Area: Container or cradle condition and securing mechanisms for deployment readiness
    Check: Container or cradle condition and securing mechanisms for deployment readiness

Typ-universelle Inspektionspunkte fuer Life Rafts (verifiziert, 2026-06).

Matchau MSC-A10
MSC-A10 ✓ verified
Application
A Pack Container Packing Throw Over Board Inflatable Life Raft
Common Failures & Inspection Points
  • Area: Visual hull and seam integrity inspection for damage, punctures, or delamination
    Check: Visual hull and seam integrity inspection for damage, punctures, or delamination
  • Area: Air pressure testing and inflation system valve functionality verification
    Check: Air pressure testing and inflation system valve functionality verification
  • Area: Emergency equipment pack contents shelf-life and completeness inspection (first aid kit, signaling flares, sea anchors, fishing kits)
    Check: Emergency equipment pack contents shelf-life and completeness inspection (first aid kit, signaling flares, sea anchors, fishing kits)
  • Area: Canopy and tarpaulin condition, UV damage assessment, and securing system functionality
    Check: Canopy and tarpaulin condition, UV damage assessment, and securing system functionality
  • Area: Sea anchors, painter lines, and boarding ladders structural integrity and attachment points
    Check: Sea anchors, painter lines, and boarding ladders structural integrity and attachment points
  • Area: Annual hydrostatic release unit (HRU) inspection and certification verification
    Check: Annual hydrostatic release unit (HRU) inspection and certification verification
  • Area: Five-year certified maintenance and recertification compliance documentation review
    Check: Five-year certified maintenance and recertification compliance documentation review
  • Area: Container or cradle condition and securing mechanisms for deployment readiness
    Check: Container or cradle condition and securing mechanisms for deployment readiness

Typ-universelle Inspektionspunkte fuer Life Rafts (verifiziert, 2026-06).

Matchau MSC-A15
MSC-A15 ✓ verified
Application
A Pack Container Packing Throw Over Board Inflatable Life Raft
Common Failures & Inspection Points
  • Area: Visual hull and seam integrity inspection for damage, punctures, or delamination
    Check: Visual hull and seam integrity inspection for damage, punctures, or delamination
  • Area: Air pressure testing and inflation system valve functionality verification
    Check: Air pressure testing and inflation system valve functionality verification
  • Area: Emergency equipment pack contents shelf-life and completeness inspection (first aid kit, signaling flares, sea anchors, fishing kits)
    Check: Emergency equipment pack contents shelf-life and completeness inspection (first aid kit, signaling flares, sea anchors, fishing kits)
  • Area: Canopy and tarpaulin condition, UV damage assessment, and securing system functionality
    Check: Canopy and tarpaulin condition, UV damage assessment, and securing system functionality
  • Area: Sea anchors, painter lines, and boarding ladders structural integrity and attachment points
    Check: Sea anchors, painter lines, and boarding ladders structural integrity and attachment points
  • Area: Annual hydrostatic release unit (HRU) inspection and certification verification
    Check: Annual hydrostatic release unit (HRU) inspection and certification verification
  • Area: Five-year certified maintenance and recertification compliance documentation review
    Check: Five-year certified maintenance and recertification compliance documentation review
  • Area: Container or cradle condition and securing mechanisms for deployment readiness
    Check: Container or cradle condition and securing mechanisms for deployment readiness

Typ-universelle Inspektionspunkte fuer Life Rafts (verifiziert, 2026-06).

Matchau MSC-A25
MSC-A25 ✓ verified
Application
A Pack Container Packing Throw Over Board Inflatable Life Raft
Common Failures & Inspection Points
  • Area: Visual hull and seam integrity inspection for damage, punctures, or delamination
    Check: Visual hull and seam integrity inspection for damage, punctures, or delamination
  • Area: Air pressure testing and inflation system valve functionality verification
    Check: Air pressure testing and inflation system valve functionality verification
  • Area: Emergency equipment pack contents shelf-life and completeness inspection (first aid kit, signaling flares, sea anchors, fishing kits)
    Check: Emergency equipment pack contents shelf-life and completeness inspection (first aid kit, signaling flares, sea anchors, fishing kits)
  • Area: Canopy and tarpaulin condition, UV damage assessment, and securing system functionality
    Check: Canopy and tarpaulin condition, UV damage assessment, and securing system functionality
  • Area: Sea anchors, painter lines, and boarding ladders structural integrity and attachment points
    Check: Sea anchors, painter lines, and boarding ladders structural integrity and attachment points
  • Area: Annual hydrostatic release unit (HRU) inspection and certification verification
    Check: Annual hydrostatic release unit (HRU) inspection and certification verification
  • Area: Five-year certified maintenance and recertification compliance documentation review
    Check: Five-year certified maintenance and recertification compliance documentation review
  • Area: Container or cradle condition and securing mechanisms for deployment readiness
    Check: Container or cradle condition and securing mechanisms for deployment readiness

Typ-universelle Inspektionspunkte fuer Life Rafts (verifiziert, 2026-06).

Seago Ltd

7 ✓ 7 verified
Seago Ltd SOLAS B - 6 Man Cylinder
SOLAS B - 6 Man Cylinder ✓ verified
Application
Offshore sailing on coded craft - Coastal configuration (SOLAS B pack)
Common Failures & Inspection Points
  • Area: Annual servicing by approved service stations at intervals not exceeding 12 months (per SOLAS III/20.8.1)
    Check: Annual servicing by approved service stations at intervals not exceeding 12 months (per SOLAS III/20.8.1)
  • Area: Visual inspection of canopy, grab lines, buoyancy chambers, and all seams for integrity and fabric damage
    Check: Visual inspection of canopy, grab lines, buoyancy chambers, and all seams for integrity and fabric damage
  • Area: Examination of seam connections (floor-to-buoyancy tube) for slippage, rupture, and lifting of edges
    Check: Examination of seam connections (floor-to-buoyancy tube) for slippage, rupture, and lifting of edges
  • Area: Verification and replacement of expired pyrotechnics, water rations, and emergency food supplies
    Check: Verification and replacement of expired pyrotechnics, water rations, and emergency food supplies
  • Area: Functional testing of mechanical components: inflation/deflation cylinders, pressure relief valves, boarding ramps
    Check: Functional testing of mechanical components: inflation/deflation cylinders, pressure relief valves, boarding ramps
  • Area: Inspection and verification of retro-reflective tape condition and adhesion (canopy perimeter and floor cross pattern)
    Check: Inspection and verification of retro-reflective tape condition and adhesion (canopy perimeter and floor cross pattern)
  • Area: Pressure-retention test on buoyancy chambers: minimum 5% pressure loss tolerance over 5 minutes after inflation
    Check: Pressure-retention test on buoyancy chambers: minimum 5% pressure loss tolerance over 5 minutes after inflation
  • Area: Inspection of inflation cylinder condition, hydrostatic testing, and cylinder weight verification (recharge if >5% weight loss)
    Check: Inspection of inflation cylinder condition, hydrostatic testing, and cylinder weight verification (recharge if >5% weight loss)

Typ-universelle Inspektionspunkte fuer Life Rafts (verifiziert, 2026-06).

Seago Ltd SOLAS B - 8 Man Cylinder
SOLAS B - 8 Man Cylinder ✓ verified
Application
Offshore sailing on coded craft - Coastal configuration (SOLAS B pack)
Common Failures & Inspection Points
  • Area: Annual servicing by approved service stations at intervals not exceeding 12 months (per SOLAS III/20.8.1)
    Check: Annual servicing by approved service stations at intervals not exceeding 12 months (per SOLAS III/20.8.1)
  • Area: Visual inspection of canopy, grab lines, buoyancy chambers, and all seams for integrity and fabric damage
    Check: Visual inspection of canopy, grab lines, buoyancy chambers, and all seams for integrity and fabric damage
  • Area: Examination of seam connections (floor-to-buoyancy tube) for slippage, rupture, and lifting of edges
    Check: Examination of seam connections (floor-to-buoyancy tube) for slippage, rupture, and lifting of edges
  • Area: Verification and replacement of expired pyrotechnics, water rations, and emergency food supplies
    Check: Verification and replacement of expired pyrotechnics, water rations, and emergency food supplies
  • Area: Functional testing of mechanical components: inflation/deflation cylinders, pressure relief valves, boarding ramps
    Check: Functional testing of mechanical components: inflation/deflation cylinders, pressure relief valves, boarding ramps
  • Area: Inspection and verification of retro-reflective tape condition and adhesion (canopy perimeter and floor cross pattern)
    Check: Inspection and verification of retro-reflective tape condition and adhesion (canopy perimeter and floor cross pattern)
  • Area: Pressure-retention test on buoyancy chambers: minimum 5% pressure loss tolerance over 5 minutes after inflation
    Check: Pressure-retention test on buoyancy chambers: minimum 5% pressure loss tolerance over 5 minutes after inflation
  • Area: Inspection of inflation cylinder condition, hydrostatic testing, and cylinder weight verification (recharge if >5% weight loss)
    Check: Inspection of inflation cylinder condition, hydrostatic testing, and cylinder weight verification (recharge if >5% weight loss)

Typ-universelle Inspektionspunkte fuer Life Rafts (verifiziert, 2026-06).

Seago Ltd SOLAS B - 10 Man Cylinder
SOLAS B - 10 Man Cylinder ✓ verified
Application
Offshore sailing on coded craft - Coastal configuration (SOLAS B pack)
Common Failures & Inspection Points
  • Area: Annual servicing by approved service stations at intervals not exceeding 12 months (per SOLAS III/20.8.1)
    Check: Annual servicing by approved service stations at intervals not exceeding 12 months (per SOLAS III/20.8.1)
  • Area: Visual inspection of canopy, grab lines, buoyancy chambers, and all seams for integrity and fabric damage
    Check: Visual inspection of canopy, grab lines, buoyancy chambers, and all seams for integrity and fabric damage
  • Area: Examination of seam connections (floor-to-buoyancy tube) for slippage, rupture, and lifting of edges
    Check: Examination of seam connections (floor-to-buoyancy tube) for slippage, rupture, and lifting of edges
  • Area: Verification and replacement of expired pyrotechnics, water rations, and emergency food supplies
    Check: Verification and replacement of expired pyrotechnics, water rations, and emergency food supplies
  • Area: Functional testing of mechanical components: inflation/deflation cylinders, pressure relief valves, boarding ramps
    Check: Functional testing of mechanical components: inflation/deflation cylinders, pressure relief valves, boarding ramps
  • Area: Inspection and verification of retro-reflective tape condition and adhesion (canopy perimeter and floor cross pattern)
    Check: Inspection and verification of retro-reflective tape condition and adhesion (canopy perimeter and floor cross pattern)
  • Area: Pressure-retention test on buoyancy chambers: minimum 5% pressure loss tolerance over 5 minutes after inflation
    Check: Pressure-retention test on buoyancy chambers: minimum 5% pressure loss tolerance over 5 minutes after inflation
  • Area: Inspection of inflation cylinder condition, hydrostatic testing, and cylinder weight verification (recharge if >5% weight loss)
    Check: Inspection of inflation cylinder condition, hydrostatic testing, and cylinder weight verification (recharge if >5% weight loss)

Typ-universelle Inspektionspunkte fuer Life Rafts (verifiziert, 2026-06).

Seago Ltd SOLAS B - 12 Man Cylinder
SOLAS B - 12 Man Cylinder ✓ verified
Application
Offshore sailing on coded craft - Coastal configuration (SOLAS B pack)
Common Failures & Inspection Points
  • Area: Annual servicing by approved service stations at intervals not exceeding 12 months (per SOLAS III/20.8.1)
    Check: Annual servicing by approved service stations at intervals not exceeding 12 months (per SOLAS III/20.8.1)
  • Area: Visual inspection of canopy, grab lines, buoyancy chambers, and all seams for integrity and fabric damage
    Check: Visual inspection of canopy, grab lines, buoyancy chambers, and all seams for integrity and fabric damage
  • Area: Examination of seam connections (floor-to-buoyancy tube) for slippage, rupture, and lifting of edges
    Check: Examination of seam connections (floor-to-buoyancy tube) for slippage, rupture, and lifting of edges
  • Area: Verification and replacement of expired pyrotechnics, water rations, and emergency food supplies
    Check: Verification and replacement of expired pyrotechnics, water rations, and emergency food supplies
  • Area: Functional testing of mechanical components: inflation/deflation cylinders, pressure relief valves, boarding ramps
    Check: Functional testing of mechanical components: inflation/deflation cylinders, pressure relief valves, boarding ramps
  • Area: Inspection and verification of retro-reflective tape condition and adhesion (canopy perimeter and floor cross pattern)
    Check: Inspection and verification of retro-reflective tape condition and adhesion (canopy perimeter and floor cross pattern)
  • Area: Pressure-retention test on buoyancy chambers: minimum 5% pressure loss tolerance over 5 minutes after inflation
    Check: Pressure-retention test on buoyancy chambers: minimum 5% pressure loss tolerance over 5 minutes after inflation
  • Area: Inspection of inflation cylinder condition, hydrostatic testing, and cylinder weight verification (recharge if >5% weight loss)
    Check: Inspection of inflation cylinder condition, hydrostatic testing, and cylinder weight verification (recharge if >5% weight loss)

Typ-universelle Inspektionspunkte fuer Life Rafts (verifiziert, 2026-06).

Seago Ltd SOLAS B - 16 Man Cylinder
SOLAS B - 16 Man Cylinder ✓ verified
Application
Offshore sailing on coded craft - Coastal configuration (SOLAS B pack)
Common Failures & Inspection Points
  • Area: Annual servicing by approved service stations at intervals not exceeding 12 months (per SOLAS III/20.8.1)
    Check: Annual servicing by approved service stations at intervals not exceeding 12 months (per SOLAS III/20.8.1)
  • Area: Visual inspection of canopy, grab lines, buoyancy chambers, and all seams for integrity and fabric damage
    Check: Visual inspection of canopy, grab lines, buoyancy chambers, and all seams for integrity and fabric damage
  • Area: Examination of seam connections (floor-to-buoyancy tube) for slippage, rupture, and lifting of edges
    Check: Examination of seam connections (floor-to-buoyancy tube) for slippage, rupture, and lifting of edges
  • Area: Verification and replacement of expired pyrotechnics, water rations, and emergency food supplies
    Check: Verification and replacement of expired pyrotechnics, water rations, and emergency food supplies
  • Area: Functional testing of mechanical components: inflation/deflation cylinders, pressure relief valves, boarding ramps
    Check: Functional testing of mechanical components: inflation/deflation cylinders, pressure relief valves, boarding ramps
  • Area: Inspection and verification of retro-reflective tape condition and adhesion (canopy perimeter and floor cross pattern)
    Check: Inspection and verification of retro-reflective tape condition and adhesion (canopy perimeter and floor cross pattern)
  • Area: Pressure-retention test on buoyancy chambers: minimum 5% pressure loss tolerance over 5 minutes after inflation
    Check: Pressure-retention test on buoyancy chambers: minimum 5% pressure loss tolerance over 5 minutes after inflation
  • Area: Inspection of inflation cylinder condition, hydrostatic testing, and cylinder weight verification (recharge if >5% weight loss)
    Check: Inspection of inflation cylinder condition, hydrostatic testing, and cylinder weight verification (recharge if >5% weight loss)

Typ-universelle Inspektionspunkte fuer Life Rafts (verifiziert, 2026-06).

Seago Ltd SOLAS B - 20 Man Cylinder
SOLAS B - 20 Man Cylinder ✓ verified
Application
Offshore sailing on coded craft - Coastal configuration (SOLAS B pack)
Common Failures & Inspection Points
  • Area: Annual servicing by approved service stations at intervals not exceeding 12 months (per SOLAS III/20.8.1)
    Check: Annual servicing by approved service stations at intervals not exceeding 12 months (per SOLAS III/20.8.1)
  • Area: Visual inspection of canopy, grab lines, buoyancy chambers, and all seams for integrity and fabric damage
    Check: Visual inspection of canopy, grab lines, buoyancy chambers, and all seams for integrity and fabric damage
  • Area: Examination of seam connections (floor-to-buoyancy tube) for slippage, rupture, and lifting of edges
    Check: Examination of seam connections (floor-to-buoyancy tube) for slippage, rupture, and lifting of edges
  • Area: Verification and replacement of expired pyrotechnics, water rations, and emergency food supplies
    Check: Verification and replacement of expired pyrotechnics, water rations, and emergency food supplies
  • Area: Functional testing of mechanical components: inflation/deflation cylinders, pressure relief valves, boarding ramps
    Check: Functional testing of mechanical components: inflation/deflation cylinders, pressure relief valves, boarding ramps
  • Area: Inspection and verification of retro-reflective tape condition and adhesion (canopy perimeter and floor cross pattern)
    Check: Inspection and verification of retro-reflective tape condition and adhesion (canopy perimeter and floor cross pattern)
  • Area: Pressure-retention test on buoyancy chambers: minimum 5% pressure loss tolerance over 5 minutes after inflation
    Check: Pressure-retention test on buoyancy chambers: minimum 5% pressure loss tolerance over 5 minutes after inflation
  • Area: Inspection of inflation cylinder condition, hydrostatic testing, and cylinder weight verification (recharge if >5% weight loss)
    Check: Inspection of inflation cylinder condition, hydrostatic testing, and cylinder weight verification (recharge if >5% weight loss)

Typ-universelle Inspektionspunkte fuer Life Rafts (verifiziert, 2026-06).

Seago Ltd SOLAS B - 25 Man Cylinder
SOLAS B - 25 Man Cylinder ✓ verified
Application
Offshore sailing on coded craft - Coastal configuration (SOLAS B pack)
Common Failures & Inspection Points
  • Area: Annual servicing by approved service stations at intervals not exceeding 12 months (per SOLAS III/20.8.1)
    Check: Annual servicing by approved service stations at intervals not exceeding 12 months (per SOLAS III/20.8.1)
  • Area: Visual inspection of canopy, grab lines, buoyancy chambers, and all seams for integrity and fabric damage
    Check: Visual inspection of canopy, grab lines, buoyancy chambers, and all seams for integrity and fabric damage
  • Area: Examination of seam connections (floor-to-buoyancy tube) for slippage, rupture, and lifting of edges
    Check: Examination of seam connections (floor-to-buoyancy tube) for slippage, rupture, and lifting of edges
  • Area: Verification and replacement of expired pyrotechnics, water rations, and emergency food supplies
    Check: Verification and replacement of expired pyrotechnics, water rations, and emergency food supplies
  • Area: Functional testing of mechanical components: inflation/deflation cylinders, pressure relief valves, boarding ramps
    Check: Functional testing of mechanical components: inflation/deflation cylinders, pressure relief valves, boarding ramps
  • Area: Inspection and verification of retro-reflective tape condition and adhesion (canopy perimeter and floor cross pattern)
    Check: Inspection and verification of retro-reflective tape condition and adhesion (canopy perimeter and floor cross pattern)
  • Area: Pressure-retention test on buoyancy chambers: minimum 5% pressure loss tolerance over 5 minutes after inflation
    Check: Pressure-retention test on buoyancy chambers: minimum 5% pressure loss tolerance over 5 minutes after inflation
  • Area: Inspection of inflation cylinder condition, hydrostatic testing, and cylinder weight verification (recharge if >5% weight loss)
    Check: Inspection of inflation cylinder condition, hydrostatic testing, and cylinder weight verification (recharge if >5% weight loss)

Typ-universelle Inspektionspunkte fuer Life Rafts (verifiziert, 2026-06).

Ocean Safety

6 ✓ 6 verified
Ocean Safety Ltd Ocean ISO Liferaft - SOLAS B Container
Ocean ISO Liferaft - SOLAS B Container ✓ verified
Application
Leisure/Commercial - ISO 9650 Type 1 compliant liferaft for offshore sailing
Common Failures & Inspection Points
  • Area: Annual servicing at approved station within 12-month intervals (17 months with extension)
    Check: Annual servicing at approved station within 12-month intervals (17 months with extension)
  • Area: Full inflation inspection of fabric, seams, and all structural components for damage or deterioration
    Check: Full inflation inspection of fabric, seams, and all structural components for damage or deterioration
  • Area: Verify all SOLAS equipment against manufacturer packing list (flares, mirrors, whistles, sea anchors, paddles, thermal protective aids)
    Check: Verify all SOLAS equipment against manufacturer packing list (flares, mirrors, whistles, sea anchors, paddles, thermal protective aids)
  • Area: Test and replace expired pyrotechnics, water rations, and food supplies
    Check: Test and replace expired pyrotechnics, water rations, and food supplies
  • Area: Inspect and test mechanical components: CO2 inflation cylinders, relief valves, boarding ramps, ladders
    Check: Inspect and test mechanical components: CO2 inflation cylinders, relief valves, boarding ramps, ladders
  • Area: Inspect retroreflective material marking to IMO revised recommendation standards
    Check: Inspect retroreflective material marking to IMO revised recommendation standards
  • Area: Hydrostatic Release Unit (HRU) replacement at maximum 2-year intervals regardless of condition
    Check: Hydrostatic Release Unit (HRU) replacement at maximum 2-year intervals regardless of condition
  • Area: Manual inflation pump functional testing and verification
    Check: Manual inflation pump functional testing and verification
  • Area: Check all instruction labels, lighting systems (internal/external), and signaling equipment functionality
    Check: Check all instruction labels, lighting systems (internal/external), and signaling equipment functionality

Typ-universelle Inspektionspunkte fuer Life Rafts (verifiziert, 2026-06).

Ocean Safety Ltd Ocean ISO Liferaft - SOLAS B Valise
Ocean ISO Liferaft - SOLAS B Valise ✓ verified
Application
Leisure/Commercial - ISO 9650 Type 1 compliant liferaft for offshore sailing, soft-bag packaging
Common Failures & Inspection Points
  • Area: Annual servicing at approved station within 12-month intervals (17 months with extension)
    Check: Annual servicing at approved station within 12-month intervals (17 months with extension)
  • Area: Full inflation inspection of fabric, seams, and all structural components for damage or deterioration
    Check: Full inflation inspection of fabric, seams, and all structural components for damage or deterioration
  • Area: Verify all SOLAS equipment against manufacturer packing list (flares, mirrors, whistles, sea anchors, paddles, thermal protective aids)
    Check: Verify all SOLAS equipment against manufacturer packing list (flares, mirrors, whistles, sea anchors, paddles, thermal protective aids)
  • Area: Test and replace expired pyrotechnics, water rations, and food supplies
    Check: Test and replace expired pyrotechnics, water rations, and food supplies
  • Area: Inspect and test mechanical components: CO2 inflation cylinders, relief valves, boarding ramps, ladders
    Check: Inspect and test mechanical components: CO2 inflation cylinders, relief valves, boarding ramps, ladders
  • Area: Inspect retroreflective material marking to IMO revised recommendation standards
    Check: Inspect retroreflective material marking to IMO revised recommendation standards
  • Area: Hydrostatic Release Unit (HRU) replacement at maximum 2-year intervals regardless of condition
    Check: Hydrostatic Release Unit (HRU) replacement at maximum 2-year intervals regardless of condition
  • Area: Manual inflation pump functional testing and verification
    Check: Manual inflation pump functional testing and verification
  • Area: Check all instruction labels, lighting systems (internal/external), and signaling equipment functionality
    Check: Check all instruction labels, lighting systems (internal/external), and signaling equipment functionality

Typ-universelle Inspektionspunkte fuer Life Rafts (verifiziert, 2026-06).

Ocean Safety Ltd Ocean Regatta Liferaft - SOLAS B Container
Ocean Regatta Liferaft - SOLAS B Container ✓ verified
Application
Leisure/Commercial - Ultra-compact ISO 9650 Type 1 for space-constrained vessels
Common Failures & Inspection Points
  • Area: Annual servicing at approved station within 12-month intervals (17 months with extension)
    Check: Annual servicing at approved station within 12-month intervals (17 months with extension)
  • Area: Full inflation inspection of fabric, seams, and all structural components for damage or deterioration
    Check: Full inflation inspection of fabric, seams, and all structural components for damage or deterioration
  • Area: Verify all SOLAS equipment against manufacturer packing list (flares, mirrors, whistles, sea anchors, paddles, thermal protective aids)
    Check: Verify all SOLAS equipment against manufacturer packing list (flares, mirrors, whistles, sea anchors, paddles, thermal protective aids)
  • Area: Test and replace expired pyrotechnics, water rations, and food supplies
    Check: Test and replace expired pyrotechnics, water rations, and food supplies
  • Area: Inspect and test mechanical components: CO2 inflation cylinders, relief valves, boarding ramps, ladders
    Check: Inspect and test mechanical components: CO2 inflation cylinders, relief valves, boarding ramps, ladders
  • Area: Inspect retroreflective material marking to IMO revised recommendation standards
    Check: Inspect retroreflective material marking to IMO revised recommendation standards
  • Area: Hydrostatic Release Unit (HRU) replacement at maximum 2-year intervals regardless of condition
    Check: Hydrostatic Release Unit (HRU) replacement at maximum 2-year intervals regardless of condition
  • Area: Manual inflation pump functional testing and verification
    Check: Manual inflation pump functional testing and verification
  • Area: Check all instruction labels, lighting systems (internal/external), and signaling equipment functionality
    Check: Check all instruction labels, lighting systems (internal/external), and signaling equipment functionality

Typ-universelle Inspektionspunkte fuer Life Rafts (verifiziert, 2026-06).

Ocean Safety Ltd Ocean SOLAS Compact Liferaft - SOLAS B Container
Ocean SOLAS Compact Liferaft - SOLAS B Container ✓ verified
Application
Commercial SOLAS - Flat-pack container design for 18m freeboard vessels
Common Failures & Inspection Points
  • Area: Annual servicing at approved station within 12-month intervals (17 months with extension)
    Check: Annual servicing at approved station within 12-month intervals (17 months with extension)
  • Area: Full inflation inspection of fabric, seams, and all structural components for damage or deterioration
    Check: Full inflation inspection of fabric, seams, and all structural components for damage or deterioration
  • Area: Verify all SOLAS equipment against manufacturer packing list (flares, mirrors, whistles, sea anchors, paddles, thermal protective aids)
    Check: Verify all SOLAS equipment against manufacturer packing list (flares, mirrors, whistles, sea anchors, paddles, thermal protective aids)
  • Area: Test and replace expired pyrotechnics, water rations, and food supplies
    Check: Test and replace expired pyrotechnics, water rations, and food supplies
  • Area: Inspect and test mechanical components: CO2 inflation cylinders, relief valves, boarding ramps, ladders
    Check: Inspect and test mechanical components: CO2 inflation cylinders, relief valves, boarding ramps, ladders
  • Area: Inspect retroreflective material marking to IMO revised recommendation standards
    Check: Inspect retroreflective material marking to IMO revised recommendation standards
  • Area: Hydrostatic Release Unit (HRU) replacement at maximum 2-year intervals regardless of condition
    Check: Hydrostatic Release Unit (HRU) replacement at maximum 2-year intervals regardless of condition
  • Area: Manual inflation pump functional testing and verification
    Check: Manual inflation pump functional testing and verification
  • Area: Check all instruction labels, lighting systems (internal/external), and signaling equipment functionality
    Check: Check all instruction labels, lighting systems (internal/external), and signaling equipment functionality

Typ-universelle Inspektionspunkte fuer Life Rafts (verifiziert, 2026-06).

Ocean Safety Ltd Ocean SOLAS Throw-Over Liferaft - SOLAS B Container
Ocean SOLAS Throw-Over Liferaft - SOLAS B Container ✓ verified
Application
Commercial SOLAS - Cylindrical container throw-over type for vessels to 25m freeboard
Common Failures & Inspection Points
  • Area: Annual servicing at approved station within 12-month intervals (17 months with extension)
    Check: Annual servicing at approved station within 12-month intervals (17 months with extension)
  • Area: Full inflation inspection of fabric, seams, and all structural components for damage or deterioration
    Check: Full inflation inspection of fabric, seams, and all structural components for damage or deterioration
  • Area: Verify all SOLAS equipment against manufacturer packing list (flares, mirrors, whistles, sea anchors, paddles, thermal protective aids)
    Check: Verify all SOLAS equipment against manufacturer packing list (flares, mirrors, whistles, sea anchors, paddles, thermal protective aids)
  • Area: Test and replace expired pyrotechnics, water rations, and food supplies
    Check: Test and replace expired pyrotechnics, water rations, and food supplies
  • Area: Inspect and test mechanical components: CO2 inflation cylinders, relief valves, boarding ramps, ladders
    Check: Inspect and test mechanical components: CO2 inflation cylinders, relief valves, boarding ramps, ladders
  • Area: Inspect retroreflective material marking to IMO revised recommendation standards
    Check: Inspect retroreflective material marking to IMO revised recommendation standards
  • Area: Hydrostatic Release Unit (HRU) replacement at maximum 2-year intervals regardless of condition
    Check: Hydrostatic Release Unit (HRU) replacement at maximum 2-year intervals regardless of condition
  • Area: Manual inflation pump functional testing and verification
    Check: Manual inflation pump functional testing and verification
  • Area: Check all instruction labels, lighting systems (internal/external), and signaling equipment functionality
    Check: Check all instruction labels, lighting systems (internal/external), and signaling equipment functionality

Typ-universelle Inspektionspunkte fuer Life Rafts (verifiziert, 2026-06).

Ocean Safety Ltd Ocean SOLAS Ellipse Liferaft - SOLAS B Container
Ocean SOLAS Ellipse Liferaft - SOLAS B Container ✓ verified
Application
Commercial SOLAS - Ellipse-shaped container design for throw-over deployment
Common Failures & Inspection Points
  • Area: Annual servicing at approved station within 12-month intervals (17 months with extension)
    Check: Annual servicing at approved station within 12-month intervals (17 months with extension)
  • Area: Full inflation inspection of fabric, seams, and all structural components for damage or deterioration
    Check: Full inflation inspection of fabric, seams, and all structural components for damage or deterioration
  • Area: Verify all SOLAS equipment against manufacturer packing list (flares, mirrors, whistles, sea anchors, paddles, thermal protective aids)
    Check: Verify all SOLAS equipment against manufacturer packing list (flares, mirrors, whistles, sea anchors, paddles, thermal protective aids)
  • Area: Test and replace expired pyrotechnics, water rations, and food supplies
    Check: Test and replace expired pyrotechnics, water rations, and food supplies
  • Area: Inspect and test mechanical components: CO2 inflation cylinders, relief valves, boarding ramps, ladders
    Check: Inspect and test mechanical components: CO2 inflation cylinders, relief valves, boarding ramps, ladders
  • Area: Inspect retroreflective material marking to IMO revised recommendation standards
    Check: Inspect retroreflective material marking to IMO revised recommendation standards
  • Area: Hydrostatic Release Unit (HRU) replacement at maximum 2-year intervals regardless of condition
    Check: Hydrostatic Release Unit (HRU) replacement at maximum 2-year intervals regardless of condition
  • Area: Manual inflation pump functional testing and verification
    Check: Manual inflation pump functional testing and verification
  • Area: Check all instruction labels, lighting systems (internal/external), and signaling equipment functionality
    Check: Check all instruction labels, lighting systems (internal/external), and signaling equipment functionality

Typ-universelle Inspektionspunkte fuer Life Rafts (verifiziert, 2026-06).

Survitec Group

6 ✓ 6 verified
Survitec Group RFD Surviva
RFD Surviva ✓ verified
Application
Commercial marine life raft, throw-over and davit-launched configurations
Common Failures & Inspection Points
  • Area: Visual inspection of buoyancy chambers for deterioration, cracks, or abrasion damage to the fabric and seams
    Check: Visual inspection of buoyancy chambers for deterioration, cracks, or abrasion damage to the fabric and seams
  • Area: Examination of inflatable canopy for tears, corrosion of retro-reflective materials, and structural integrity
    Check: Examination of inflatable canopy for tears, corrosion of retro-reflective materials, and structural integrity
  • Area: Functional testing of manual inflation pump and CO2 inflation system for proper operation
    Check: Functional testing of manual inflation pump and CO2 inflation system for proper operation
  • Area: Verification and replacement of expired emergency supplies (pyrotechnics, food rations, fresh water bottles, first aid kit contents)
    Check: Verification and replacement of expired emergency supplies (pyrotechnics, food rations, fresh water bottles, first aid kit contents)
  • Area: Testing of hydrostatic release unit (HRU) within validity period and functionality verification
    Check: Testing of hydrostatic release unit (HRU) within validity period and functionality verification
  • Area: Inspection and functionality test of boarding ramps, grab lines, and emergency equipment securing mechanisms
    Check: Inspection and functionality test of boarding ramps, grab lines, and emergency equipment securing mechanisms
  • Area: Verification of all SOLAS-B emergency equipment pack contents against packing list and certification documentation
    Check: Verification of all SOLAS-B emergency equipment pack contents against packing list and certification documentation
  • Area: Annual servicing compliance verification and certification maintenance by approved service station within 12-month intervals
    Check: Annual servicing compliance verification and certification maintenance by approved service station within 12-month intervals

Typ-universelle Inspektionspunkte fuer Life Rafts (verifiziert, 2026-06).

Survitec Group DSB LR07
DSB LR07 ✓ verified
Application
Davit-launched commercial liferaft
Common Failures & Inspection Points
  • Area: Visual inspection of buoyancy chambers for deterioration, cracks, or abrasion damage to the fabric and seams
    Check: Visual inspection of buoyancy chambers for deterioration, cracks, or abrasion damage to the fabric and seams
  • Area: Examination of inflatable canopy for tears, corrosion of retro-reflective materials, and structural integrity
    Check: Examination of inflatable canopy for tears, corrosion of retro-reflective materials, and structural integrity
  • Area: Functional testing of manual inflation pump and CO2 inflation system for proper operation
    Check: Functional testing of manual inflation pump and CO2 inflation system for proper operation
  • Area: Verification and replacement of expired emergency supplies (pyrotechnics, food rations, fresh water bottles, first aid kit contents)
    Check: Verification and replacement of expired emergency supplies (pyrotechnics, food rations, fresh water bottles, first aid kit contents)
  • Area: Testing of hydrostatic release unit (HRU) within validity period and functionality verification
    Check: Testing of hydrostatic release unit (HRU) within validity period and functionality verification
  • Area: Inspection and functionality test of boarding ramps, grab lines, and emergency equipment securing mechanisms
    Check: Inspection and functionality test of boarding ramps, grab lines, and emergency equipment securing mechanisms
  • Area: Verification of all SOLAS-B emergency equipment pack contents against packing list and certification documentation
    Check: Verification of all SOLAS-B emergency equipment pack contents against packing list and certification documentation
  • Area: Annual servicing compliance verification and certification maintenance by approved service station within 12-month intervals
    Check: Annual servicing compliance verification and certification maintenance by approved service station within 12-month intervals

Typ-universelle Inspektionspunkte fuer Life Rafts (verifiziert, 2026-06).

Survitec Group DSB LR97SR Self-Righting
DSB LR97SR Self-Righting ✓ verified
Application
Self-righting throw-over and davit-launched commercial liferaft
Common Failures & Inspection Points
  • Area: Visual inspection of buoyancy chambers for deterioration, cracks, or abrasion damage to the fabric and seams
    Check: Visual inspection of buoyancy chambers for deterioration, cracks, or abrasion damage to the fabric and seams
  • Area: Examination of inflatable canopy for tears, corrosion of retro-reflective materials, and structural integrity
    Check: Examination of inflatable canopy for tears, corrosion of retro-reflective materials, and structural integrity
  • Area: Functional testing of manual inflation pump and CO2 inflation system for proper operation
    Check: Functional testing of manual inflation pump and CO2 inflation system for proper operation
  • Area: Verification and replacement of expired emergency supplies (pyrotechnics, food rations, fresh water bottles, first aid kit contents)
    Check: Verification and replacement of expired emergency supplies (pyrotechnics, food rations, fresh water bottles, first aid kit contents)
  • Area: Testing of hydrostatic release unit (HRU) within validity period and functionality verification
    Check: Testing of hydrostatic release unit (HRU) within validity period and functionality verification
  • Area: Inspection and functionality test of boarding ramps, grab lines, and emergency equipment securing mechanisms
    Check: Inspection and functionality test of boarding ramps, grab lines, and emergency equipment securing mechanisms
  • Area: Verification of all SOLAS-B emergency equipment pack contents against packing list and certification documentation
    Check: Verification of all SOLAS-B emergency equipment pack contents against packing list and certification documentation
  • Area: Annual servicing compliance verification and certification maintenance by approved service station within 12-month intervals
    Check: Annual servicing compliance verification and certification maintenance by approved service station within 12-month intervals

Typ-universelle Inspektionspunkte fuer Life Rafts (verifiziert, 2026-06).

Survitec Group Survitec Zodiac Xtrem
Survitec Zodiac Xtrem ✓ verified
Application
Compact throw-over liferaft for yachts and small vessels
Common Failures & Inspection Points
  • Area: Visual inspection of buoyancy chambers for deterioration, cracks, or abrasion damage to the fabric and seams
    Check: Visual inspection of buoyancy chambers for deterioration, cracks, or abrasion damage to the fabric and seams
  • Area: Examination of inflatable canopy for tears, corrosion of retro-reflective materials, and structural integrity
    Check: Examination of inflatable canopy for tears, corrosion of retro-reflective materials, and structural integrity
  • Area: Functional testing of manual inflation pump and CO2 inflation system for proper operation
    Check: Functional testing of manual inflation pump and CO2 inflation system for proper operation
  • Area: Verification and replacement of expired emergency supplies (pyrotechnics, food rations, fresh water bottles, first aid kit contents)
    Check: Verification and replacement of expired emergency supplies (pyrotechnics, food rations, fresh water bottles, first aid kit contents)
  • Area: Testing of hydrostatic release unit (HRU) within validity period and functionality verification
    Check: Testing of hydrostatic release unit (HRU) within validity period and functionality verification
  • Area: Inspection and functionality test of boarding ramps, grab lines, and emergency equipment securing mechanisms
    Check: Inspection and functionality test of boarding ramps, grab lines, and emergency equipment securing mechanisms
  • Area: Verification of all SOLAS-B emergency equipment pack contents against packing list and certification documentation
    Check: Verification of all SOLAS-B emergency equipment pack contents against packing list and certification documentation
  • Area: Annual servicing compliance verification and certification maintenance by approved service station within 12-month intervals
    Check: Annual servicing compliance verification and certification maintenance by approved service station within 12-month intervals

Typ-universelle Inspektionspunkte fuer Life Rafts (verifiziert, 2026-06).

Survitec Group Elliot
Elliot ✓ verified
Application
Commercial throw-over liferaft, USCG/SOLAS approved
Common Failures & Inspection Points
  • Area: Visual inspection of buoyancy chambers for deterioration, cracks, or abrasion damage to the fabric and seams
    Check: Visual inspection of buoyancy chambers for deterioration, cracks, or abrasion damage to the fabric and seams
  • Area: Examination of inflatable canopy for tears, corrosion of retro-reflective materials, and structural integrity
    Check: Examination of inflatable canopy for tears, corrosion of retro-reflective materials, and structural integrity
  • Area: Functional testing of manual inflation pump and CO2 inflation system for proper operation
    Check: Functional testing of manual inflation pump and CO2 inflation system for proper operation
  • Area: Verification and replacement of expired emergency supplies (pyrotechnics, food rations, fresh water bottles, first aid kit contents)
    Check: Verification and replacement of expired emergency supplies (pyrotechnics, food rations, fresh water bottles, first aid kit contents)
  • Area: Testing of hydrostatic release unit (HRU) within validity period and functionality verification
    Check: Testing of hydrostatic release unit (HRU) within validity period and functionality verification
  • Area: Inspection and functionality test of boarding ramps, grab lines, and emergency equipment securing mechanisms
    Check: Inspection and functionality test of boarding ramps, grab lines, and emergency equipment securing mechanisms
  • Area: Verification of all SOLAS-B emergency equipment pack contents against packing list and certification documentation
    Check: Verification of all SOLAS-B emergency equipment pack contents against packing list and certification documentation
  • Area: Annual servicing compliance verification and certification maintenance by approved service station within 12-month intervals
    Check: Annual servicing compliance verification and certification maintenance by approved service station within 12-month intervals

Typ-universelle Inspektionspunkte fuer Life Rafts (verifiziert, 2026-06).

Survitec Group Crewsaver
Crewsaver ✓ verified
Application
Commercial throw-over liferaft, USCG/SOLAS approved
Common Failures & Inspection Points
  • Area: Visual inspection of buoyancy chambers for deterioration, cracks, or abrasion damage to the fabric and seams
    Check: Visual inspection of buoyancy chambers for deterioration, cracks, or abrasion damage to the fabric and seams
  • Area: Examination of inflatable canopy for tears, corrosion of retro-reflective materials, and structural integrity
    Check: Examination of inflatable canopy for tears, corrosion of retro-reflective materials, and structural integrity
  • Area: Functional testing of manual inflation pump and CO2 inflation system for proper operation
    Check: Functional testing of manual inflation pump and CO2 inflation system for proper operation
  • Area: Verification and replacement of expired emergency supplies (pyrotechnics, food rations, fresh water bottles, first aid kit contents)
    Check: Verification and replacement of expired emergency supplies (pyrotechnics, food rations, fresh water bottles, first aid kit contents)
  • Area: Testing of hydrostatic release unit (HRU) within validity period and functionality verification
    Check: Testing of hydrostatic release unit (HRU) within validity period and functionality verification
  • Area: Inspection and functionality test of boarding ramps, grab lines, and emergency equipment securing mechanisms
    Check: Inspection and functionality test of boarding ramps, grab lines, and emergency equipment securing mechanisms
  • Area: Verification of all SOLAS-B emergency equipment pack contents against packing list and certification documentation
    Check: Verification of all SOLAS-B emergency equipment pack contents against packing list and certification documentation
  • Area: Annual servicing compliance verification and certification maintenance by approved service station within 12-month intervals
    Check: Annual servicing compliance verification and certification maintenance by approved service station within 12-month intervals

Typ-universelle Inspektionspunkte fuer Life Rafts (verifiziert, 2026-06).

Winslow LifeRaft Company

3 ✓ 3 verified
Winslow LifeRaft Company Ultra-Light Offshore (ULO)
Ultra-Light Offshore (ULO) ✓ verified
Application
Recreational marine, offshore
Common Failures & Inspection Points
  • Area: Visual exterior inspection of raft container and retroreflective material for damage or deterioration; replace if damaged or faded
    Check: Visual exterior inspection of raft container and retroreflective material for damage or deterioration; replace if damaged or faded
  • Area: Internal full inflation and structural integrity check: inspect fabric, seams, and all buoyancy tubes for tears, punctures, cracks, or seam slippage
    Check: Internal full inflation and structural integrity check: inspect fabric, seams, and all buoyancy tubes for tears, punctures, cracks, or seam slippage
  • Area: Pressurized seam test (NAP - Necessary Additional Pressure): pressurize to specified level, monitor for 5-minute hold with maximum 5% pressure drop allowed
    Check: Pressurized seam test (NAP - Necessary Additional Pressure): pressurize to specified level, monitor for 5-minute hold with maximum 5% pressure drop allowed
  • Area: Inflation system functionality: test CO2/N2 inflation cylinders for proper pressure and deploy mechanisms; inspect relief and topping-up valves
    Check: Inflation system functionality: test CO2/N2 inflation cylinders for proper pressure and deploy mechanisms; inspect relief and topping-up valves
  • Area: Seawater activation and manual inflation pump testing for proper operation and response
    Check: Seawater activation and manual inflation pump testing for proper operation and response
  • Area: Survival equipment inventory verification against SOLAS packing list: expired pyrotechnics, food rations, water packets, first aid kits must be current
    Check: Survival equipment inventory verification against SOLAS packing list: expired pyrotechnics, food rations, water packets, first aid kits must be current
  • Area: Hydrostatic Release Unit (HRU) replacement: must be replaced at maximum 2-year intervals regardless of condition; expired HRU renders entire assembly non-compli
    Check: Hydrostatic Release Unit (HRU) replacement: must be replaced at maximum 2-year intervals regardless of condition; expired HRU renders entire assembly non-compliant
  • Area: Floor seam integrity testing (from 10th year service onward): full pressurization test on floor compartments with soapy water leak detection at seams
    Check: Floor seam integrity testing (from 10th year service onward): full pressurization test on floor compartments with soapy water leak detection at seams

Typ-universelle Inspektionspunkte fuer Life Rafts (verifiziert, 2026-06).

Winslow LifeRaft Company Super-Light Rescue Raft 2 (SLRR2)
Super-Light Rescue Raft 2 (SLRR2) ✓ verified
Application
Inshore/day sailing, rescue
Common Failures & Inspection Points
  • Area: Visual exterior inspection of raft container and retroreflective material for damage or deterioration; replace if damaged or faded
    Check: Visual exterior inspection of raft container and retroreflective material for damage or deterioration; replace if damaged or faded
  • Area: Internal full inflation and structural integrity check: inspect fabric, seams, and all buoyancy tubes for tears, punctures, cracks, or seam slippage
    Check: Internal full inflation and structural integrity check: inspect fabric, seams, and all buoyancy tubes for tears, punctures, cracks, or seam slippage
  • Area: Pressurized seam test (NAP - Necessary Additional Pressure): pressurize to specified level, monitor for 5-minute hold with maximum 5% pressure drop allowed
    Check: Pressurized seam test (NAP - Necessary Additional Pressure): pressurize to specified level, monitor for 5-minute hold with maximum 5% pressure drop allowed
  • Area: Inflation system functionality: test CO2/N2 inflation cylinders for proper pressure and deploy mechanisms; inspect relief and topping-up valves
    Check: Inflation system functionality: test CO2/N2 inflation cylinders for proper pressure and deploy mechanisms; inspect relief and topping-up valves
  • Area: Seawater activation and manual inflation pump testing for proper operation and response
    Check: Seawater activation and manual inflation pump testing for proper operation and response
  • Area: Survival equipment inventory verification against SOLAS packing list: expired pyrotechnics, food rations, water packets, first aid kits must be current
    Check: Survival equipment inventory verification against SOLAS packing list: expired pyrotechnics, food rations, water packets, first aid kits must be current
  • Area: Hydrostatic Release Unit (HRU) replacement: must be replaced at maximum 2-year intervals regardless of condition; expired HRU renders entire assembly non-compli
    Check: Hydrostatic Release Unit (HRU) replacement: must be replaced at maximum 2-year intervals regardless of condition; expired HRU renders entire assembly non-compliant
  • Area: Floor seam integrity testing (from 10th year service onward): full pressurization test on floor compartments with soapy water leak detection at seams
    Check: Floor seam integrity testing (from 10th year service onward): full pressurization test on floor compartments with soapy water leak detection at seams

Typ-universelle Inspektionspunkte fuer Life Rafts (verifiziert, 2026-06).

Winslow LifeRaft Company Law Enforcement Emergency Pac (LEEP)
Law Enforcement Emergency Pac (LEEP) ✓ verified
Application
Law enforcement, emergency rescue, helicopter deployment
Common Failures & Inspection Points
  • Area: Visual exterior inspection of raft container and retroreflective material for damage or deterioration; replace if damaged or faded
    Check: Visual exterior inspection of raft container and retroreflective material for damage or deterioration; replace if damaged or faded
  • Area: Internal full inflation and structural integrity check: inspect fabric, seams, and all buoyancy tubes for tears, punctures, cracks, or seam slippage
    Check: Internal full inflation and structural integrity check: inspect fabric, seams, and all buoyancy tubes for tears, punctures, cracks, or seam slippage
  • Area: Pressurized seam test (NAP - Necessary Additional Pressure): pressurize to specified level, monitor for 5-minute hold with maximum 5% pressure drop allowed
    Check: Pressurized seam test (NAP - Necessary Additional Pressure): pressurize to specified level, monitor for 5-minute hold with maximum 5% pressure drop allowed
  • Area: Inflation system functionality: test CO2/N2 inflation cylinders for proper pressure and deploy mechanisms; inspect relief and topping-up valves
    Check: Inflation system functionality: test CO2/N2 inflation cylinders for proper pressure and deploy mechanisms; inspect relief and topping-up valves
  • Area: Seawater activation and manual inflation pump testing for proper operation and response
    Check: Seawater activation and manual inflation pump testing for proper operation and response
  • Area: Survival equipment inventory verification against SOLAS packing list: expired pyrotechnics, food rations, water packets, first aid kits must be current
    Check: Survival equipment inventory verification against SOLAS packing list: expired pyrotechnics, food rations, water packets, first aid kits must be current
  • Area: Hydrostatic Release Unit (HRU) replacement: must be replaced at maximum 2-year intervals regardless of condition; expired HRU renders entire assembly non-compli
    Check: Hydrostatic Release Unit (HRU) replacement: must be replaced at maximum 2-year intervals regardless of condition; expired HRU renders entire assembly non-compliant
  • Area: Floor seam integrity testing (from 10th year service onward): full pressurization test on floor compartments with soapy water leak detection at seams
    Check: Floor seam integrity testing (from 10th year service onward): full pressurization test on floor compartments with soapy water leak detection at seams

Typ-universelle Inspektionspunkte fuer Life Rafts (verifiziert, 2026-06).

Survitec / RFD

36
Survitec / RFD Survitec Eurocompact 4P
Survitec Eurocompact 4P unverified
Capacity (persons)
4
SOLAS Approved
ja
Survitec / RFD Survitec Eurocompact 6P
Survitec Eurocompact 6P unverified
Capacity (persons)
6
SOLAS Approved
ja
Survitec / RFD Survitec Eurocompact 8P
Survitec Eurocompact 8P unverified
Capacity (persons)
8
SOLAS Approved
ja
Survitec / RFD Survitec Eurocompact 10P
Survitec Eurocompact 10P unverified
Capacity (persons)
10
SOLAS Approved
ja
Survitec / RFD Survitec Eurocompact 12P
Survitec Eurocompact 12P unverified
Capacity (persons)
12
SOLAS Approved
ja
Survitec / RFD Survitec Eurocompact 16P
Survitec Eurocompact 16P unverified
Capacity (persons)
16
SOLAS Approved
ja
Survitec / RFD Survitec Eurocompact 20P
Survitec Eurocompact 20P unverified
Capacity (persons)
20
SOLAS Approved
ja
Survitec / RFD Survitec Eurocompact 25P
Survitec Eurocompact 25P unverified
Capacity (persons)
25
SOLAS Approved
ja
Survitec / RFD Survitec Eurocompact 35P
Survitec Eurocompact 35P unverified
Capacity (persons)
35
SOLAS Approved
ja
Survitec / RFD Survitec Eurocompact 50P
Survitec Eurocompact 50P unverified
Capacity (persons)
50
SOLAS Approved
ja
Survitec / RFD Survitec SOLAS-B Container 4P
Survitec SOLAS-B Container 4P unverified
Capacity (persons)
4
Packing
Container
Survitec / RFD Survitec SOLAS-B Container 6P
Survitec SOLAS-B Container 6P unverified
Capacity (persons)
6
Packing
Container
Survitec / RFD Survitec SOLAS-B Container 8P
Survitec SOLAS-B Container 8P unverified
Capacity (persons)
8
Packing
Container
Survitec / RFD Survitec SOLAS-B Container 10P
Survitec SOLAS-B Container 10P unverified
Capacity (persons)
10
Packing
Container
Survitec / RFD Survitec SOLAS-B Container 12P
Survitec SOLAS-B Container 12P unverified
Capacity (persons)
12
Packing
Container
Survitec / RFD Survitec SOLAS-B Container 16P
Survitec SOLAS-B Container 16P unverified
Capacity (persons)
16
Packing
Container
Survitec / RFD Survitec SOLAS-B Container 20P
Survitec SOLAS-B Container 20P unverified
Capacity (persons)
20
Packing
Container
Survitec / RFD Survitec SOLAS-B Container 25P
Survitec SOLAS-B Container 25P unverified
Capacity (persons)
25
Packing
Container
Survitec / RFD Survitec SOLAS-B Valise 4P
Survitec SOLAS-B Valise 4P unverified
Capacity (persons)
4
Packing
Valise
Survitec / RFD Survitec SOLAS-B Valise 6P
Survitec SOLAS-B Valise 6P unverified
Capacity (persons)
6
Packing
Valise
Survitec / RFD Survitec SOLAS-B Valise 8P
Survitec SOLAS-B Valise 8P unverified
Capacity (persons)
8
Packing
Valise
Survitec / RFD Survitec SOLAS-B Valise 10P
Survitec SOLAS-B Valise 10P unverified
Capacity (persons)
10
Packing
Valise
Survitec / RFD Survitec SOLAS-B Valise 12P
Survitec SOLAS-B Valise 12P unverified
Capacity (persons)
12
Packing
Valise
Survitec / RFD Survitec SOLAS-B Valise 16P
Survitec SOLAS-B Valise 16P unverified
Capacity (persons)
16
Packing
Valise
Survitec / RFD Survitec SOLAS-B Valise 20P
Survitec SOLAS-B Valise 20P unverified
Capacity (persons)
20
Packing
Valise
Survitec / RFD Survitec SOLAS-B Valise 25P
Survitec SOLAS-B Valise 25P unverified
Capacity (persons)
25
Packing
Valise
Survitec / RFD Survitec SOLAS-B Soft Valise 4P-B
Survitec SOLAS-B Soft Valise 4P-B unverified
Capacity (persons)
4
Packing
Soft Valise
Survitec / RFD Survitec SOLAS-B Soft Valise 6P-B
Survitec SOLAS-B Soft Valise 6P-B unverified
Capacity (persons)
6
Packing
Soft Valise
Survitec / RFD Survitec SOLAS-B Soft Valise 8P-B
Survitec SOLAS-B Soft Valise 8P-B unverified
Capacity (persons)
8
Packing
Soft Valise
Survitec / RFD Survitec SOLAS-B Soft Valise 10P-B
Survitec SOLAS-B Soft Valise 10P-B unverified
Capacity (persons)
10
Packing
Soft Valise
Survitec / RFD Survitec SOLAS-B Soft Valise 12P-B
Survitec SOLAS-B Soft Valise 12P-B unverified
Capacity (persons)
12
Packing
Soft Valise
Survitec / RFD Survitec SOLAS-B Rigid Container 4P-B
Survitec SOLAS-B Rigid Container 4P-B unverified
Capacity (persons)
4
Packing
Rigid Container
Survitec / RFD Survitec SOLAS-B Rigid Container 6P-B
Survitec SOLAS-B Rigid Container 6P-B unverified
Capacity (persons)
6
Packing
Rigid Container
Survitec / RFD Survitec SOLAS-B Rigid Container 8P-B
Survitec SOLAS-B Rigid Container 8P-B unverified
Capacity (persons)
8
Packing
Rigid Container
Survitec / RFD Survitec SOLAS-B Rigid Container 10P-B
Survitec SOLAS-B Rigid Container 10P-B unverified
Capacity (persons)
10
Packing
Rigid Container
Survitec / RFD Survitec SOLAS-B Rigid Container 12P-B
Survitec SOLAS-B Rigid Container 12P-B unverified
Capacity (persons)
12
Packing
Rigid Container

Zodiac Marine

26
Zodiac Marine Zodiac Coastal 4P
Zodiac Coastal 4P unverified
Capacity (persons)
4
Zodiac Marine Zodiac Coastal 6P
Zodiac Coastal 6P unverified
Capacity (persons)
6
Zodiac Marine Zodiac Coastal 8P
Zodiac Coastal 8P unverified
Capacity (persons)
8
Zodiac Marine Zodiac Coastal 10P
Zodiac Coastal 10P unverified
Capacity (persons)
10
Zodiac Marine Zodiac Coastal 12P
Zodiac Coastal 12P unverified
Capacity (persons)
12
Zodiac Marine Zodiac Coastal 16P
Zodiac Coastal 16P unverified
Capacity (persons)
16
Zodiac Marine Zodiac Coastal 20P
Zodiac Coastal 20P unverified
Capacity (persons)
20
Zodiac Marine Zodiac Coastal 25P
Zodiac Coastal 25P unverified
Capacity (persons)
25
Zodiac Marine Zodiac Offshore 4P
Zodiac Offshore 4P unverified
Capacity (persons)
4
Zodiac Marine Zodiac Offshore 6P
Zodiac Offshore 6P unverified
Capacity (persons)
6
Zodiac Marine Zodiac Offshore 8P
Zodiac Offshore 8P unverified
Capacity (persons)
8
Zodiac Marine Zodiac Offshore 10P
Zodiac Offshore 10P unverified
Capacity (persons)
10
Zodiac Marine Zodiac Offshore 12P
Zodiac Offshore 12P unverified
Capacity (persons)
12
Zodiac Marine Zodiac Offshore 16P
Zodiac Offshore 16P unverified
Capacity (persons)
16
Zodiac Marine Zodiac Offshore 20P
Zodiac Offshore 20P unverified
Capacity (persons)
20
Zodiac Marine Zodiac Offshore 25P
Zodiac Offshore 25P unverified
Capacity (persons)
25
Zodiac Marine Zodiac Marine SOLAS-B Soft Valise 4P-B
Zodiac Marine SOLAS-B Soft Valise 4P-B unverified
Capacity (persons)
4
Packing
Soft Valise
Zodiac Marine Zodiac Marine SOLAS-B Soft Valise 6P-B
Zodiac Marine SOLAS-B Soft Valise 6P-B unverified
Capacity (persons)
6
Packing
Soft Valise
Zodiac Marine Zodiac Marine SOLAS-B Soft Valise 8P-B
Zodiac Marine SOLAS-B Soft Valise 8P-B unverified
Capacity (persons)
8
Packing
Soft Valise
Zodiac Marine Zodiac Marine SOLAS-B Soft Valise 10P-B
Zodiac Marine SOLAS-B Soft Valise 10P-B unverified
Capacity (persons)
10
Packing
Soft Valise
Zodiac Marine Zodiac Marine SOLAS-B Soft Valise 12P-B
Zodiac Marine SOLAS-B Soft Valise 12P-B unverified
Capacity (persons)
12
Packing
Soft Valise
Zodiac Marine Zodiac Marine SOLAS-B Rigid Container 4P-B
Zodiac Marine SOLAS-B Rigid Container 4P-B unverified
Capacity (persons)
4
Packing
Rigid Container
Zodiac Marine Zodiac Marine SOLAS-B Rigid Container 6P-B
Zodiac Marine SOLAS-B Rigid Container 6P-B unverified
Capacity (persons)
6
Packing
Rigid Container
Zodiac Marine Zodiac Marine SOLAS-B Rigid Container 8P-B
Zodiac Marine SOLAS-B Rigid Container 8P-B unverified
Capacity (persons)
8
Packing
Rigid Container
Zodiac Marine Zodiac Marine SOLAS-B Rigid Container 10P-B
Zodiac Marine SOLAS-B Rigid Container 10P-B unverified
Capacity (persons)
10
Packing
Rigid Container
Zodiac Marine Zodiac Marine SOLAS-B Rigid Container 12P-B
Zodiac Marine SOLAS-B Rigid Container 12P-B unverified
Capacity (persons)
12
Packing
Rigid Container

Plastimo

20
Plastimo Plastimo Cruiser 4P
Plastimo Cruiser 4P unverified
Capacity (persons)
4
Plastimo Plastimo Cruiser 6P
Plastimo Cruiser 6P unverified
Capacity (persons)
6
Plastimo Plastimo Cruiser 8P
Plastimo Cruiser 8P unverified
Capacity (persons)
8
Plastimo Plastimo Cruiser 10P
Plastimo Cruiser 10P unverified
Capacity (persons)
10
Plastimo Plastimo Cruiser 12P
Plastimo Cruiser 12P unverified
Capacity (persons)
12
Plastimo Plastimo Transocean 4P
Plastimo Transocean 4P unverified
Capacity (persons)
4
Plastimo Plastimo Transocean 6P
Plastimo Transocean 6P unverified
Capacity (persons)
6
Plastimo Plastimo Transocean 8P
Plastimo Transocean 8P unverified
Capacity (persons)
8
Plastimo Plastimo Transocean 10P
Plastimo Transocean 10P unverified
Capacity (persons)
10
Plastimo Plastimo Transocean 12P
Plastimo Transocean 12P unverified
Capacity (persons)
12
Plastimo Plastimo SOLAS-B Soft Valise 4P-B
Plastimo SOLAS-B Soft Valise 4P-B unverified
Capacity (persons)
4
Packing
Soft Valise
Plastimo Plastimo SOLAS-B Soft Valise 6P-B
Plastimo SOLAS-B Soft Valise 6P-B unverified
Capacity (persons)
6
Packing
Soft Valise
Plastimo Plastimo SOLAS-B Soft Valise 8P-B
Plastimo SOLAS-B Soft Valise 8P-B unverified
Capacity (persons)
8
Packing
Soft Valise
Plastimo Plastimo SOLAS-B Soft Valise 10P-B
Plastimo SOLAS-B Soft Valise 10P-B unverified
Capacity (persons)
10
Packing
Soft Valise
Plastimo Plastimo SOLAS-B Soft Valise 12P-B
Plastimo SOLAS-B Soft Valise 12P-B unverified
Capacity (persons)
12
Packing
Soft Valise
Plastimo Plastimo SOLAS-B Rigid Container 4P-B
Plastimo SOLAS-B Rigid Container 4P-B unverified
Capacity (persons)
4
Packing
Rigid Container
Plastimo Plastimo SOLAS-B Rigid Container 6P-B
Plastimo SOLAS-B Rigid Container 6P-B unverified
Capacity (persons)
6
Packing
Rigid Container
Plastimo Plastimo SOLAS-B Rigid Container 8P-B
Plastimo SOLAS-B Rigid Container 8P-B unverified
Capacity (persons)
8
Packing
Rigid Container
Plastimo Plastimo SOLAS-B Rigid Container 10P-B
Plastimo SOLAS-B Rigid Container 10P-B unverified
Capacity (persons)
10
Packing
Rigid Container
Plastimo Plastimo SOLAS-B Rigid Container 12P-B
Plastimo SOLAS-B Rigid Container 12P-B unverified
Capacity (persons)
12
Packing
Rigid Container

VIKING Life-Saving

20
Viking Life-Saving Equipment Viking SOLAS-B 4P
Viking SOLAS-B 4P
Capacity (persons)
4
SOLAS Approved
ja
Technical Specifications
Kapazitätsbereich
4 bis 35 Personen (DK+ & DKF+ Serien)
Behältertypen
Rund, Quadratisch, Low-Profile (Fiberglas)
Funktionstemperatur
-30°C bis +65°C (Standard); -50°C für Polar-Versionen
Inflation
Automatisch durch Painter-Linie oder CO2-Zylinder; Inflation innerhalb 1 Minute (Throw-overboard)
Notfall-packungen
SOLAS A (Standard) oder SOLAS B
Behälter-Material
Starrer Fiberglas-Container mit Schaumstoff-Polsterung
Stabilität
Zwei unabhängige Auftriebskammern; bleibt stabil auch bei einer deflatierten Kammer
Product Lines
  • DK+ Throw-overboard (4-35 Personen)
  • DKF+ Davit-launched (12-35 Personen)
  • S30 Extended Service Interval (alle Kapazitäten)
  • RescYou Recreational Series (Yachting)
Common Failures & Inspection Points
  • Area: Jährliches Service-Intervall (SOLAS)
    Check: Inspekteur prüft auf Serviceetiketten-Datum (nicht älter als 12 Monate); Standard SOLAS erfordert vollständige Inspektion, Inflations-Test, Zylinder-Kontrolle, Ausrüstungs-Inventar (Pyrotechnik, Wasser, Rationen)
  • Area: HRU (Hydrostatic Release Unit) - Austausch maximal alle 24 Monate
    Check: Inspekteur verifiziert HRU-Verfallsdatum unabhängig vom Raft-Service-Datum; PSC prüft beide Daten separat; muss mit Raft-Modell kompatibel sein; Hammar H20 oder ähnliche zertifizierte Modelle verwenden
  • Area: Painter-Linie und Weak-Link-System
    Check: Inspekteur prüft: Painter permanent mit Schiff verbunden; Weak-Link korrekt an HRU angebracht; Weak-Link-Bruchfestigkeit 1.6-2.0 kN; rote Farbe und 30 ft (ca. 10m) Länge bei Throw-overboard; Befestigung muss Aufzugskraft aushalten und bei Schiffsuntergang unter Raft-Gewicht reißen
  • Area: Behälter-Integrität und Lashing-Straps
    Check: Inspekteur kontrolliert: Behälter auf Risse, Verformungen, Wasserschäden; Lashing-Straps fest und unbeschädigt; Wiege/Cradle sicher befestigt; Container horizontal stabil gelagert; Siegel intakt
  • Area: Davit-System Prüfung (nur DKF+-Modelle)
    Check: Inspekteur prüft: Davit mit Schnellen/Seilen verbunden; Raft-Anschlussgurte intakt; Laterale Impact-Prüfung: Raft muss Aufprall 3.5 m/s gegen Schiffswand aushalten; Wasser-Eintauch-Test aus 3m Höhe ohne Funktionsverlust; Launching-Muster dokumentieren
  • Area: S30 Extended Service Interval - Jährliche Bordsinspektion (30-Monate-Option)
    Check: Inspekteur (Crew) führt 3-Schritt-Bordsinspektion durch: Test-Panel für Umgebung in Aluminium-Beutel; Sichtprüfung Container; keine elektrische Ausrüstung nötig; vollständiger Service alle 30 Monate an zertifizierter Viking-Station (statt 12 Monate Standard); keine Interval-Verlängerungen möglich für S30

Typ-universelle Inspektions-/Wartungspunkte fuer Life Rafts (Viking Life-Saving Equipment, Mega-Schwarm 2026-06). Per-Modell-Specs nicht auto-gefuellt.

Viking Life-Saving Equipment Viking SOLAS-B 6P
Viking SOLAS-B 6P
Capacity (persons)
6
SOLAS Approved
ja
Technical Specifications
Kapazitätsbereich
4 bis 35 Personen (DK+ & DKF+ Serien)
Behältertypen
Rund, Quadratisch, Low-Profile (Fiberglas)
Funktionstemperatur
-30°C bis +65°C (Standard); -50°C für Polar-Versionen
Inflation
Automatisch durch Painter-Linie oder CO2-Zylinder; Inflation innerhalb 1 Minute (Throw-overboard)
Notfall-packungen
SOLAS A (Standard) oder SOLAS B
Behälter-Material
Starrer Fiberglas-Container mit Schaumstoff-Polsterung
Stabilität
Zwei unabhängige Auftriebskammern; bleibt stabil auch bei einer deflatierten Kammer
Product Lines
  • DK+ Throw-overboard (4-35 Personen)
  • DKF+ Davit-launched (12-35 Personen)
  • S30 Extended Service Interval (alle Kapazitäten)
  • RescYou Recreational Series (Yachting)
Common Failures & Inspection Points
  • Area: Jährliches Service-Intervall (SOLAS)
    Check: Inspekteur prüft auf Serviceetiketten-Datum (nicht älter als 12 Monate); Standard SOLAS erfordert vollständige Inspektion, Inflations-Test, Zylinder-Kontrolle, Ausrüstungs-Inventar (Pyrotechnik, Wasser, Rationen)
  • Area: HRU (Hydrostatic Release Unit) - Austausch maximal alle 24 Monate
    Check: Inspekteur verifiziert HRU-Verfallsdatum unabhängig vom Raft-Service-Datum; PSC prüft beide Daten separat; muss mit Raft-Modell kompatibel sein; Hammar H20 oder ähnliche zertifizierte Modelle verwenden
  • Area: Painter-Linie und Weak-Link-System
    Check: Inspekteur prüft: Painter permanent mit Schiff verbunden; Weak-Link korrekt an HRU angebracht; Weak-Link-Bruchfestigkeit 1.6-2.0 kN; rote Farbe und 30 ft (ca. 10m) Länge bei Throw-overboard; Befestigung muss Aufzugskraft aushalten und bei Schiffsuntergang unter Raft-Gewicht reißen
  • Area: Behälter-Integrität und Lashing-Straps
    Check: Inspekteur kontrolliert: Behälter auf Risse, Verformungen, Wasserschäden; Lashing-Straps fest und unbeschädigt; Wiege/Cradle sicher befestigt; Container horizontal stabil gelagert; Siegel intakt
  • Area: Davit-System Prüfung (nur DKF+-Modelle)
    Check: Inspekteur prüft: Davit mit Schnellen/Seilen verbunden; Raft-Anschlussgurte intakt; Laterale Impact-Prüfung: Raft muss Aufprall 3.5 m/s gegen Schiffswand aushalten; Wasser-Eintauch-Test aus 3m Höhe ohne Funktionsverlust; Launching-Muster dokumentieren
  • Area: S30 Extended Service Interval - Jährliche Bordsinspektion (30-Monate-Option)
    Check: Inspekteur (Crew) führt 3-Schritt-Bordsinspektion durch: Test-Panel für Umgebung in Aluminium-Beutel; Sichtprüfung Container; keine elektrische Ausrüstung nötig; vollständiger Service alle 30 Monate an zertifizierter Viking-Station (statt 12 Monate Standard); keine Interval-Verlängerungen möglich für S30

Typ-universelle Inspektions-/Wartungspunkte fuer Life Rafts (Viking Life-Saving Equipment, Mega-Schwarm 2026-06). Per-Modell-Specs nicht auto-gefuellt.

Viking Life-Saving Equipment Viking SOLAS-B 8P
Viking SOLAS-B 8P
Capacity (persons)
8
SOLAS Approved
ja
Technical Specifications
Kapazitätsbereich
4 bis 35 Personen (DK+ & DKF+ Serien)
Behältertypen
Rund, Quadratisch, Low-Profile (Fiberglas)
Funktionstemperatur
-30°C bis +65°C (Standard); -50°C für Polar-Versionen
Inflation
Automatisch durch Painter-Linie oder CO2-Zylinder; Inflation innerhalb 1 Minute (Throw-overboard)
Notfall-packungen
SOLAS A (Standard) oder SOLAS B
Behälter-Material
Starrer Fiberglas-Container mit Schaumstoff-Polsterung
Stabilität
Zwei unabhängige Auftriebskammern; bleibt stabil auch bei einer deflatierten Kammer
Product Lines
  • DK+ Throw-overboard (4-35 Personen)
  • DKF+ Davit-launched (12-35 Personen)
  • S30 Extended Service Interval (alle Kapazitäten)
  • RescYou Recreational Series (Yachting)
Common Failures & Inspection Points
  • Area: Jährliches Service-Intervall (SOLAS)
    Check: Inspekteur prüft auf Serviceetiketten-Datum (nicht älter als 12 Monate); Standard SOLAS erfordert vollständige Inspektion, Inflations-Test, Zylinder-Kontrolle, Ausrüstungs-Inventar (Pyrotechnik, Wasser, Rationen)
  • Area: HRU (Hydrostatic Release Unit) - Austausch maximal alle 24 Monate
    Check: Inspekteur verifiziert HRU-Verfallsdatum unabhängig vom Raft-Service-Datum; PSC prüft beide Daten separat; muss mit Raft-Modell kompatibel sein; Hammar H20 oder ähnliche zertifizierte Modelle verwenden
  • Area: Painter-Linie und Weak-Link-System
    Check: Inspekteur prüft: Painter permanent mit Schiff verbunden; Weak-Link korrekt an HRU angebracht; Weak-Link-Bruchfestigkeit 1.6-2.0 kN; rote Farbe und 30 ft (ca. 10m) Länge bei Throw-overboard; Befestigung muss Aufzugskraft aushalten und bei Schiffsuntergang unter Raft-Gewicht reißen
  • Area: Behälter-Integrität und Lashing-Straps
    Check: Inspekteur kontrolliert: Behälter auf Risse, Verformungen, Wasserschäden; Lashing-Straps fest und unbeschädigt; Wiege/Cradle sicher befestigt; Container horizontal stabil gelagert; Siegel intakt
  • Area: Davit-System Prüfung (nur DKF+-Modelle)
    Check: Inspekteur prüft: Davit mit Schnellen/Seilen verbunden; Raft-Anschlussgurte intakt; Laterale Impact-Prüfung: Raft muss Aufprall 3.5 m/s gegen Schiffswand aushalten; Wasser-Eintauch-Test aus 3m Höhe ohne Funktionsverlust; Launching-Muster dokumentieren
  • Area: S30 Extended Service Interval - Jährliche Bordsinspektion (30-Monate-Option)
    Check: Inspekteur (Crew) führt 3-Schritt-Bordsinspektion durch: Test-Panel für Umgebung in Aluminium-Beutel; Sichtprüfung Container; keine elektrische Ausrüstung nötig; vollständiger Service alle 30 Monate an zertifizierter Viking-Station (statt 12 Monate Standard); keine Interval-Verlängerungen möglich für S30

Typ-universelle Inspektions-/Wartungspunkte fuer Life Rafts (Viking Life-Saving Equipment, Mega-Schwarm 2026-06). Per-Modell-Specs nicht auto-gefuellt.

Viking Life-Saving Equipment Viking SOLAS-B 10P
Viking SOLAS-B 10P
Capacity (persons)
10
SOLAS Approved
ja
Technical Specifications
Kapazitätsbereich
4 bis 35 Personen (DK+ & DKF+ Serien)
Behältertypen
Rund, Quadratisch, Low-Profile (Fiberglas)
Funktionstemperatur
-30°C bis +65°C (Standard); -50°C für Polar-Versionen
Inflation
Automatisch durch Painter-Linie oder CO2-Zylinder; Inflation innerhalb 1 Minute (Throw-overboard)
Notfall-packungen
SOLAS A (Standard) oder SOLAS B
Behälter-Material
Starrer Fiberglas-Container mit Schaumstoff-Polsterung
Stabilität
Zwei unabhängige Auftriebskammern; bleibt stabil auch bei einer deflatierten Kammer
Product Lines
  • DK+ Throw-overboard (4-35 Personen)
  • DKF+ Davit-launched (12-35 Personen)
  • S30 Extended Service Interval (alle Kapazitäten)
  • RescYou Recreational Series (Yachting)
Common Failures & Inspection Points
  • Area: Jährliches Service-Intervall (SOLAS)
    Check: Inspekteur prüft auf Serviceetiketten-Datum (nicht älter als 12 Monate); Standard SOLAS erfordert vollständige Inspektion, Inflations-Test, Zylinder-Kontrolle, Ausrüstungs-Inventar (Pyrotechnik, Wasser, Rationen)
  • Area: HRU (Hydrostatic Release Unit) - Austausch maximal alle 24 Monate
    Check: Inspekteur verifiziert HRU-Verfallsdatum unabhängig vom Raft-Service-Datum; PSC prüft beide Daten separat; muss mit Raft-Modell kompatibel sein; Hammar H20 oder ähnliche zertifizierte Modelle verwenden
  • Area: Painter-Linie und Weak-Link-System
    Check: Inspekteur prüft: Painter permanent mit Schiff verbunden; Weak-Link korrekt an HRU angebracht; Weak-Link-Bruchfestigkeit 1.6-2.0 kN; rote Farbe und 30 ft (ca. 10m) Länge bei Throw-overboard; Befestigung muss Aufzugskraft aushalten und bei Schiffsuntergang unter Raft-Gewicht reißen
  • Area: Behälter-Integrität und Lashing-Straps
    Check: Inspekteur kontrolliert: Behälter auf Risse, Verformungen, Wasserschäden; Lashing-Straps fest und unbeschädigt; Wiege/Cradle sicher befestigt; Container horizontal stabil gelagert; Siegel intakt
  • Area: Davit-System Prüfung (nur DKF+-Modelle)
    Check: Inspekteur prüft: Davit mit Schnellen/Seilen verbunden; Raft-Anschlussgurte intakt; Laterale Impact-Prüfung: Raft muss Aufprall 3.5 m/s gegen Schiffswand aushalten; Wasser-Eintauch-Test aus 3m Höhe ohne Funktionsverlust; Launching-Muster dokumentieren
  • Area: S30 Extended Service Interval - Jährliche Bordsinspektion (30-Monate-Option)
    Check: Inspekteur (Crew) führt 3-Schritt-Bordsinspektion durch: Test-Panel für Umgebung in Aluminium-Beutel; Sichtprüfung Container; keine elektrische Ausrüstung nötig; vollständiger Service alle 30 Monate an zertifizierter Viking-Station (statt 12 Monate Standard); keine Interval-Verlängerungen möglich für S30

Typ-universelle Inspektions-/Wartungspunkte fuer Life Rafts (Viking Life-Saving Equipment, Mega-Schwarm 2026-06). Per-Modell-Specs nicht auto-gefuellt.

Viking Life-Saving Equipment Viking SOLAS-B 12P
Viking SOLAS-B 12P
Capacity (persons)
12
SOLAS Approved
ja
Technical Specifications
Kapazitätsbereich
4 bis 35 Personen (DK+ & DKF+ Serien)
Behältertypen
Rund, Quadratisch, Low-Profile (Fiberglas)
Funktionstemperatur
-30°C bis +65°C (Standard); -50°C für Polar-Versionen
Inflation
Automatisch durch Painter-Linie oder CO2-Zylinder; Inflation innerhalb 1 Minute (Throw-overboard)
Notfall-packungen
SOLAS A (Standard) oder SOLAS B
Behälter-Material
Starrer Fiberglas-Container mit Schaumstoff-Polsterung
Stabilität
Zwei unabhängige Auftriebskammern; bleibt stabil auch bei einer deflatierten Kammer
Product Lines
  • DK+ Throw-overboard (4-35 Personen)
  • DKF+ Davit-launched (12-35 Personen)
  • S30 Extended Service Interval (alle Kapazitäten)
  • RescYou Recreational Series (Yachting)
Common Failures & Inspection Points
  • Area: Jährliches Service-Intervall (SOLAS)
    Check: Inspekteur prüft auf Serviceetiketten-Datum (nicht älter als 12 Monate); Standard SOLAS erfordert vollständige Inspektion, Inflations-Test, Zylinder-Kontrolle, Ausrüstungs-Inventar (Pyrotechnik, Wasser, Rationen)
  • Area: HRU (Hydrostatic Release Unit) - Austausch maximal alle 24 Monate
    Check: Inspekteur verifiziert HRU-Verfallsdatum unabhängig vom Raft-Service-Datum; PSC prüft beide Daten separat; muss mit Raft-Modell kompatibel sein; Hammar H20 oder ähnliche zertifizierte Modelle verwenden
  • Area: Painter-Linie und Weak-Link-System
    Check: Inspekteur prüft: Painter permanent mit Schiff verbunden; Weak-Link korrekt an HRU angebracht; Weak-Link-Bruchfestigkeit 1.6-2.0 kN; rote Farbe und 30 ft (ca. 10m) Länge bei Throw-overboard; Befestigung muss Aufzugskraft aushalten und bei Schiffsuntergang unter Raft-Gewicht reißen
  • Area: Behälter-Integrität und Lashing-Straps
    Check: Inspekteur kontrolliert: Behälter auf Risse, Verformungen, Wasserschäden; Lashing-Straps fest und unbeschädigt; Wiege/Cradle sicher befestigt; Container horizontal stabil gelagert; Siegel intakt
  • Area: Davit-System Prüfung (nur DKF+-Modelle)
    Check: Inspekteur prüft: Davit mit Schnellen/Seilen verbunden; Raft-Anschlussgurte intakt; Laterale Impact-Prüfung: Raft muss Aufprall 3.5 m/s gegen Schiffswand aushalten; Wasser-Eintauch-Test aus 3m Höhe ohne Funktionsverlust; Launching-Muster dokumentieren
  • Area: S30 Extended Service Interval - Jährliche Bordsinspektion (30-Monate-Option)
    Check: Inspekteur (Crew) führt 3-Schritt-Bordsinspektion durch: Test-Panel für Umgebung in Aluminium-Beutel; Sichtprüfung Container; keine elektrische Ausrüstung nötig; vollständiger Service alle 30 Monate an zertifizierter Viking-Station (statt 12 Monate Standard); keine Interval-Verlängerungen möglich für S30

Typ-universelle Inspektions-/Wartungspunkte fuer Life Rafts (Viking Life-Saving Equipment, Mega-Schwarm 2026-06). Per-Modell-Specs nicht auto-gefuellt.

Viking Life-Saving Equipment Viking SOLAS-B 16P
Viking SOLAS-B 16P
Capacity (persons)
16
SOLAS Approved
ja
Technical Specifications
Kapazitätsbereich
4 bis 35 Personen (DK+ & DKF+ Serien)
Behältertypen
Rund, Quadratisch, Low-Profile (Fiberglas)
Funktionstemperatur
-30°C bis +65°C (Standard); -50°C für Polar-Versionen
Inflation
Automatisch durch Painter-Linie oder CO2-Zylinder; Inflation innerhalb 1 Minute (Throw-overboard)
Notfall-packungen
SOLAS A (Standard) oder SOLAS B
Behälter-Material
Starrer Fiberglas-Container mit Schaumstoff-Polsterung
Stabilität
Zwei unabhängige Auftriebskammern; bleibt stabil auch bei einer deflatierten Kammer
Product Lines
  • DK+ Throw-overboard (4-35 Personen)
  • DKF+ Davit-launched (12-35 Personen)
  • S30 Extended Service Interval (alle Kapazitäten)
  • RescYou Recreational Series (Yachting)
Common Failures & Inspection Points
  • Area: Jährliches Service-Intervall (SOLAS)
    Check: Inspekteur prüft auf Serviceetiketten-Datum (nicht älter als 12 Monate); Standard SOLAS erfordert vollständige Inspektion, Inflations-Test, Zylinder-Kontrolle, Ausrüstungs-Inventar (Pyrotechnik, Wasser, Rationen)
  • Area: HRU (Hydrostatic Release Unit) - Austausch maximal alle 24 Monate
    Check: Inspekteur verifiziert HRU-Verfallsdatum unabhängig vom Raft-Service-Datum; PSC prüft beide Daten separat; muss mit Raft-Modell kompatibel sein; Hammar H20 oder ähnliche zertifizierte Modelle verwenden
  • Area: Painter-Linie und Weak-Link-System
    Check: Inspekteur prüft: Painter permanent mit Schiff verbunden; Weak-Link korrekt an HRU angebracht; Weak-Link-Bruchfestigkeit 1.6-2.0 kN; rote Farbe und 30 ft (ca. 10m) Länge bei Throw-overboard; Befestigung muss Aufzugskraft aushalten und bei Schiffsuntergang unter Raft-Gewicht reißen
  • Area: Behälter-Integrität und Lashing-Straps
    Check: Inspekteur kontrolliert: Behälter auf Risse, Verformungen, Wasserschäden; Lashing-Straps fest und unbeschädigt; Wiege/Cradle sicher befestigt; Container horizontal stabil gelagert; Siegel intakt
  • Area: Davit-System Prüfung (nur DKF+-Modelle)
    Check: Inspekteur prüft: Davit mit Schnellen/Seilen verbunden; Raft-Anschlussgurte intakt; Laterale Impact-Prüfung: Raft muss Aufprall 3.5 m/s gegen Schiffswand aushalten; Wasser-Eintauch-Test aus 3m Höhe ohne Funktionsverlust; Launching-Muster dokumentieren
  • Area: S30 Extended Service Interval - Jährliche Bordsinspektion (30-Monate-Option)
    Check: Inspekteur (Crew) führt 3-Schritt-Bordsinspektion durch: Test-Panel für Umgebung in Aluminium-Beutel; Sichtprüfung Container; keine elektrische Ausrüstung nötig; vollständiger Service alle 30 Monate an zertifizierter Viking-Station (statt 12 Monate Standard); keine Interval-Verlängerungen möglich für S30

Typ-universelle Inspektions-/Wartungspunkte fuer Life Rafts (Viking Life-Saving Equipment, Mega-Schwarm 2026-06). Per-Modell-Specs nicht auto-gefuellt.

Viking Life-Saving Equipment Viking SOLAS-B 20P
Viking SOLAS-B 20P
Capacity (persons)
20
SOLAS Approved
ja
Technical Specifications
Kapazitätsbereich
4 bis 35 Personen (DK+ & DKF+ Serien)
Behältertypen
Rund, Quadratisch, Low-Profile (Fiberglas)
Funktionstemperatur
-30°C bis +65°C (Standard); -50°C für Polar-Versionen
Inflation
Automatisch durch Painter-Linie oder CO2-Zylinder; Inflation innerhalb 1 Minute (Throw-overboard)
Notfall-packungen
SOLAS A (Standard) oder SOLAS B
Behälter-Material
Starrer Fiberglas-Container mit Schaumstoff-Polsterung
Stabilität
Zwei unabhängige Auftriebskammern; bleibt stabil auch bei einer deflatierten Kammer
Product Lines
  • DK+ Throw-overboard (4-35 Personen)
  • DKF+ Davit-launched (12-35 Personen)
  • S30 Extended Service Interval (alle Kapazitäten)
  • RescYou Recreational Series (Yachting)
Common Failures & Inspection Points
  • Area: Jährliches Service-Intervall (SOLAS)
    Check: Inspekteur prüft auf Serviceetiketten-Datum (nicht älter als 12 Monate); Standard SOLAS erfordert vollständige Inspektion, Inflations-Test, Zylinder-Kontrolle, Ausrüstungs-Inventar (Pyrotechnik, Wasser, Rationen)
  • Area: HRU (Hydrostatic Release Unit) - Austausch maximal alle 24 Monate
    Check: Inspekteur verifiziert HRU-Verfallsdatum unabhängig vom Raft-Service-Datum; PSC prüft beide Daten separat; muss mit Raft-Modell kompatibel sein; Hammar H20 oder ähnliche zertifizierte Modelle verwenden
  • Area: Painter-Linie und Weak-Link-System
    Check: Inspekteur prüft: Painter permanent mit Schiff verbunden; Weak-Link korrekt an HRU angebracht; Weak-Link-Bruchfestigkeit 1.6-2.0 kN; rote Farbe und 30 ft (ca. 10m) Länge bei Throw-overboard; Befestigung muss Aufzugskraft aushalten und bei Schiffsuntergang unter Raft-Gewicht reißen
  • Area: Behälter-Integrität und Lashing-Straps
    Check: Inspekteur kontrolliert: Behälter auf Risse, Verformungen, Wasserschäden; Lashing-Straps fest und unbeschädigt; Wiege/Cradle sicher befestigt; Container horizontal stabil gelagert; Siegel intakt
  • Area: Davit-System Prüfung (nur DKF+-Modelle)
    Check: Inspekteur prüft: Davit mit Schnellen/Seilen verbunden; Raft-Anschlussgurte intakt; Laterale Impact-Prüfung: Raft muss Aufprall 3.5 m/s gegen Schiffswand aushalten; Wasser-Eintauch-Test aus 3m Höhe ohne Funktionsverlust; Launching-Muster dokumentieren
  • Area: S30 Extended Service Interval - Jährliche Bordsinspektion (30-Monate-Option)
    Check: Inspekteur (Crew) führt 3-Schritt-Bordsinspektion durch: Test-Panel für Umgebung in Aluminium-Beutel; Sichtprüfung Container; keine elektrische Ausrüstung nötig; vollständiger Service alle 30 Monate an zertifizierter Viking-Station (statt 12 Monate Standard); keine Interval-Verlängerungen möglich für S30

Typ-universelle Inspektions-/Wartungspunkte fuer Life Rafts (Viking Life-Saving Equipment, Mega-Schwarm 2026-06). Per-Modell-Specs nicht auto-gefuellt.

Viking Life-Saving Equipment Viking SOLAS-B 25P
Viking SOLAS-B 25P
Capacity (persons)
25
SOLAS Approved
ja
Technical Specifications
Kapazitätsbereich
4 bis 35 Personen (DK+ & DKF+ Serien)
Behältertypen
Rund, Quadratisch, Low-Profile (Fiberglas)
Funktionstemperatur
-30°C bis +65°C (Standard); -50°C für Polar-Versionen
Inflation
Automatisch durch Painter-Linie oder CO2-Zylinder; Inflation innerhalb 1 Minute (Throw-overboard)
Notfall-packungen
SOLAS A (Standard) oder SOLAS B
Behälter-Material
Starrer Fiberglas-Container mit Schaumstoff-Polsterung
Stabilität
Zwei unabhängige Auftriebskammern; bleibt stabil auch bei einer deflatierten Kammer
Product Lines
  • DK+ Throw-overboard (4-35 Personen)
  • DKF+ Davit-launched (12-35 Personen)
  • S30 Extended Service Interval (alle Kapazitäten)
  • RescYou Recreational Series (Yachting)
Common Failures & Inspection Points
  • Area: Jährliches Service-Intervall (SOLAS)
    Check: Inspekteur prüft auf Serviceetiketten-Datum (nicht älter als 12 Monate); Standard SOLAS erfordert vollständige Inspektion, Inflations-Test, Zylinder-Kontrolle, Ausrüstungs-Inventar (Pyrotechnik, Wasser, Rationen)
  • Area: HRU (Hydrostatic Release Unit) - Austausch maximal alle 24 Monate
    Check: Inspekteur verifiziert HRU-Verfallsdatum unabhängig vom Raft-Service-Datum; PSC prüft beide Daten separat; muss mit Raft-Modell kompatibel sein; Hammar H20 oder ähnliche zertifizierte Modelle verwenden
  • Area: Painter-Linie und Weak-Link-System
    Check: Inspekteur prüft: Painter permanent mit Schiff verbunden; Weak-Link korrekt an HRU angebracht; Weak-Link-Bruchfestigkeit 1.6-2.0 kN; rote Farbe und 30 ft (ca. 10m) Länge bei Throw-overboard; Befestigung muss Aufzugskraft aushalten und bei Schiffsuntergang unter Raft-Gewicht reißen
  • Area: Behälter-Integrität und Lashing-Straps
    Check: Inspekteur kontrolliert: Behälter auf Risse, Verformungen, Wasserschäden; Lashing-Straps fest und unbeschädigt; Wiege/Cradle sicher befestigt; Container horizontal stabil gelagert; Siegel intakt
  • Area: Davit-System Prüfung (nur DKF+-Modelle)
    Check: Inspekteur prüft: Davit mit Schnellen/Seilen verbunden; Raft-Anschlussgurte intakt; Laterale Impact-Prüfung: Raft muss Aufprall 3.5 m/s gegen Schiffswand aushalten; Wasser-Eintauch-Test aus 3m Höhe ohne Funktionsverlust; Launching-Muster dokumentieren
  • Area: S30 Extended Service Interval - Jährliche Bordsinspektion (30-Monate-Option)
    Check: Inspekteur (Crew) führt 3-Schritt-Bordsinspektion durch: Test-Panel für Umgebung in Aluminium-Beutel; Sichtprüfung Container; keine elektrische Ausrüstung nötig; vollständiger Service alle 30 Monate an zertifizierter Viking-Station (statt 12 Monate Standard); keine Interval-Verlängerungen möglich für S30

Typ-universelle Inspektions-/Wartungspunkte fuer Life Rafts (Viking Life-Saving Equipment, Mega-Schwarm 2026-06). Per-Modell-Specs nicht auto-gefuellt.

Viking Life-Saving Equipment Viking SOLAS-B 35P
Viking SOLAS-B 35P
Capacity (persons)
35
SOLAS Approved
ja
Technical Specifications
Kapazitätsbereich
4 bis 35 Personen (DK+ & DKF+ Serien)
Behältertypen
Rund, Quadratisch, Low-Profile (Fiberglas)
Funktionstemperatur
-30°C bis +65°C (Standard); -50°C für Polar-Versionen
Inflation
Automatisch durch Painter-Linie oder CO2-Zylinder; Inflation innerhalb 1 Minute (Throw-overboard)
Notfall-packungen
SOLAS A (Standard) oder SOLAS B
Behälter-Material
Starrer Fiberglas-Container mit Schaumstoff-Polsterung
Stabilität
Zwei unabhängige Auftriebskammern; bleibt stabil auch bei einer deflatierten Kammer
Product Lines
  • DK+ Throw-overboard (4-35 Personen)
  • DKF+ Davit-launched (12-35 Personen)
  • S30 Extended Service Interval (alle Kapazitäten)
  • RescYou Recreational Series (Yachting)
Common Failures & Inspection Points
  • Area: Jährliches Service-Intervall (SOLAS)
    Check: Inspekteur prüft auf Serviceetiketten-Datum (nicht älter als 12 Monate); Standard SOLAS erfordert vollständige Inspektion, Inflations-Test, Zylinder-Kontrolle, Ausrüstungs-Inventar (Pyrotechnik, Wasser, Rationen)
  • Area: HRU (Hydrostatic Release Unit) - Austausch maximal alle 24 Monate
    Check: Inspekteur verifiziert HRU-Verfallsdatum unabhängig vom Raft-Service-Datum; PSC prüft beide Daten separat; muss mit Raft-Modell kompatibel sein; Hammar H20 oder ähnliche zertifizierte Modelle verwenden
  • Area: Painter-Linie und Weak-Link-System
    Check: Inspekteur prüft: Painter permanent mit Schiff verbunden; Weak-Link korrekt an HRU angebracht; Weak-Link-Bruchfestigkeit 1.6-2.0 kN; rote Farbe und 30 ft (ca. 10m) Länge bei Throw-overboard; Befestigung muss Aufzugskraft aushalten und bei Schiffsuntergang unter Raft-Gewicht reißen
  • Area: Behälter-Integrität und Lashing-Straps
    Check: Inspekteur kontrolliert: Behälter auf Risse, Verformungen, Wasserschäden; Lashing-Straps fest und unbeschädigt; Wiege/Cradle sicher befestigt; Container horizontal stabil gelagert; Siegel intakt
  • Area: Davit-System Prüfung (nur DKF+-Modelle)
    Check: Inspekteur prüft: Davit mit Schnellen/Seilen verbunden; Raft-Anschlussgurte intakt; Laterale Impact-Prüfung: Raft muss Aufprall 3.5 m/s gegen Schiffswand aushalten; Wasser-Eintauch-Test aus 3m Höhe ohne Funktionsverlust; Launching-Muster dokumentieren
  • Area: S30 Extended Service Interval - Jährliche Bordsinspektion (30-Monate-Option)
    Check: Inspekteur (Crew) führt 3-Schritt-Bordsinspektion durch: Test-Panel für Umgebung in Aluminium-Beutel; Sichtprüfung Container; keine elektrische Ausrüstung nötig; vollständiger Service alle 30 Monate an zertifizierter Viking-Station (statt 12 Monate Standard); keine Interval-Verlängerungen möglich für S30

Typ-universelle Inspektions-/Wartungspunkte fuer Life Rafts (Viking Life-Saving Equipment, Mega-Schwarm 2026-06). Per-Modell-Specs nicht auto-gefuellt.

Viking Life-Saving Equipment Viking SOLAS-B 50P
Viking SOLAS-B 50P
Capacity (persons)
50
SOLAS Approved
ja
Technical Specifications
Kapazitätsbereich
4 bis 35 Personen (DK+ & DKF+ Serien)
Behältertypen
Rund, Quadratisch, Low-Profile (Fiberglas)
Funktionstemperatur
-30°C bis +65°C (Standard); -50°C für Polar-Versionen
Inflation
Automatisch durch Painter-Linie oder CO2-Zylinder; Inflation innerhalb 1 Minute (Throw-overboard)
Notfall-packungen
SOLAS A (Standard) oder SOLAS B
Behälter-Material
Starrer Fiberglas-Container mit Schaumstoff-Polsterung
Stabilität
Zwei unabhängige Auftriebskammern; bleibt stabil auch bei einer deflatierten Kammer
Product Lines
  • DK+ Throw-overboard (4-35 Personen)
  • DKF+ Davit-launched (12-35 Personen)
  • S30 Extended Service Interval (alle Kapazitäten)
  • RescYou Recreational Series (Yachting)
Common Failures & Inspection Points
  • Area: Jährliches Service-Intervall (SOLAS)
    Check: Inspekteur prüft auf Serviceetiketten-Datum (nicht älter als 12 Monate); Standard SOLAS erfordert vollständige Inspektion, Inflations-Test, Zylinder-Kontrolle, Ausrüstungs-Inventar (Pyrotechnik, Wasser, Rationen)
  • Area: HRU (Hydrostatic Release Unit) - Austausch maximal alle 24 Monate
    Check: Inspekteur verifiziert HRU-Verfallsdatum unabhängig vom Raft-Service-Datum; PSC prüft beide Daten separat; muss mit Raft-Modell kompatibel sein; Hammar H20 oder ähnliche zertifizierte Modelle verwenden
  • Area: Painter-Linie und Weak-Link-System
    Check: Inspekteur prüft: Painter permanent mit Schiff verbunden; Weak-Link korrekt an HRU angebracht; Weak-Link-Bruchfestigkeit 1.6-2.0 kN; rote Farbe und 30 ft (ca. 10m) Länge bei Throw-overboard; Befestigung muss Aufzugskraft aushalten und bei Schiffsuntergang unter Raft-Gewicht reißen
  • Area: Behälter-Integrität und Lashing-Straps
    Check: Inspekteur kontrolliert: Behälter auf Risse, Verformungen, Wasserschäden; Lashing-Straps fest und unbeschädigt; Wiege/Cradle sicher befestigt; Container horizontal stabil gelagert; Siegel intakt
  • Area: Davit-System Prüfung (nur DKF+-Modelle)
    Check: Inspekteur prüft: Davit mit Schnellen/Seilen verbunden; Raft-Anschlussgurte intakt; Laterale Impact-Prüfung: Raft muss Aufprall 3.5 m/s gegen Schiffswand aushalten; Wasser-Eintauch-Test aus 3m Höhe ohne Funktionsverlust; Launching-Muster dokumentieren
  • Area: S30 Extended Service Interval - Jährliche Bordsinspektion (30-Monate-Option)
    Check: Inspekteur (Crew) führt 3-Schritt-Bordsinspektion durch: Test-Panel für Umgebung in Aluminium-Beutel; Sichtprüfung Container; keine elektrische Ausrüstung nötig; vollständiger Service alle 30 Monate an zertifizierter Viking-Station (statt 12 Monate Standard); keine Interval-Verlängerungen möglich für S30

Typ-universelle Inspektions-/Wartungspunkte fuer Life Rafts (Viking Life-Saving Equipment, Mega-Schwarm 2026-06). Per-Modell-Specs nicht auto-gefuellt.

Viking Life-Saving Equipment Viking Life-Saving Equipment SOLAS-B Soft Valise 4P-B
Viking Life-Saving Equipment SOLAS-B Soft Valise 4P-B
Capacity (persons)
4
Packing
Soft Valise
Technical Specifications
Kapazitätsbereich
4 bis 35 Personen (DK+ & DKF+ Serien)
Behältertypen
Rund, Quadratisch, Low-Profile (Fiberglas)
Funktionstemperatur
-30°C bis +65°C (Standard); -50°C für Polar-Versionen
Inflation
Automatisch durch Painter-Linie oder CO2-Zylinder; Inflation innerhalb 1 Minute (Throw-overboard)
Notfall-packungen
SOLAS A (Standard) oder SOLAS B
Behälter-Material
Starrer Fiberglas-Container mit Schaumstoff-Polsterung
Stabilität
Zwei unabhängige Auftriebskammern; bleibt stabil auch bei einer deflatierten Kammer
Product Lines
  • DK+ Throw-overboard (4-35 Personen)
  • DKF+ Davit-launched (12-35 Personen)
  • S30 Extended Service Interval (alle Kapazitäten)
  • RescYou Recreational Series (Yachting)
Common Failures & Inspection Points
  • Area: Jährliches Service-Intervall (SOLAS)
    Check: Inspekteur prüft auf Serviceetiketten-Datum (nicht älter als 12 Monate); Standard SOLAS erfordert vollständige Inspektion, Inflations-Test, Zylinder-Kontrolle, Ausrüstungs-Inventar (Pyrotechnik, Wasser, Rationen)
  • Area: HRU (Hydrostatic Release Unit) - Austausch maximal alle 24 Monate
    Check: Inspekteur verifiziert HRU-Verfallsdatum unabhängig vom Raft-Service-Datum; PSC prüft beide Daten separat; muss mit Raft-Modell kompatibel sein; Hammar H20 oder ähnliche zertifizierte Modelle verwenden
  • Area: Painter-Linie und Weak-Link-System
    Check: Inspekteur prüft: Painter permanent mit Schiff verbunden; Weak-Link korrekt an HRU angebracht; Weak-Link-Bruchfestigkeit 1.6-2.0 kN; rote Farbe und 30 ft (ca. 10m) Länge bei Throw-overboard; Befestigung muss Aufzugskraft aushalten und bei Schiffsuntergang unter Raft-Gewicht reißen
  • Area: Behälter-Integrität und Lashing-Straps
    Check: Inspekteur kontrolliert: Behälter auf Risse, Verformungen, Wasserschäden; Lashing-Straps fest und unbeschädigt; Wiege/Cradle sicher befestigt; Container horizontal stabil gelagert; Siegel intakt
  • Area: Davit-System Prüfung (nur DKF+-Modelle)
    Check: Inspekteur prüft: Davit mit Schnellen/Seilen verbunden; Raft-Anschlussgurte intakt; Laterale Impact-Prüfung: Raft muss Aufprall 3.5 m/s gegen Schiffswand aushalten; Wasser-Eintauch-Test aus 3m Höhe ohne Funktionsverlust; Launching-Muster dokumentieren
  • Area: S30 Extended Service Interval - Jährliche Bordsinspektion (30-Monate-Option)
    Check: Inspekteur (Crew) führt 3-Schritt-Bordsinspektion durch: Test-Panel für Umgebung in Aluminium-Beutel; Sichtprüfung Container; keine elektrische Ausrüstung nötig; vollständiger Service alle 30 Monate an zertifizierter Viking-Station (statt 12 Monate Standard); keine Interval-Verlängerungen möglich für S30

Typ-universelle Inspektions-/Wartungspunkte fuer Life Rafts (Viking Life-Saving Equipment, Mega-Schwarm 2026-06). Per-Modell-Specs nicht auto-gefuellt.

Viking Life-Saving Equipment Viking Life-Saving Equipment SOLAS-B Soft Valise 6P-B
Viking Life-Saving Equipment SOLAS-B Soft Valise 6P-B
Capacity (persons)
6
Packing
Soft Valise
Technical Specifications
Kapazitätsbereich
4 bis 35 Personen (DK+ & DKF+ Serien)
Behältertypen
Rund, Quadratisch, Low-Profile (Fiberglas)
Funktionstemperatur
-30°C bis +65°C (Standard); -50°C für Polar-Versionen
Inflation
Automatisch durch Painter-Linie oder CO2-Zylinder; Inflation innerhalb 1 Minute (Throw-overboard)
Notfall-packungen
SOLAS A (Standard) oder SOLAS B
Behälter-Material
Starrer Fiberglas-Container mit Schaumstoff-Polsterung
Stabilität
Zwei unabhängige Auftriebskammern; bleibt stabil auch bei einer deflatierten Kammer
Product Lines
  • DK+ Throw-overboard (4-35 Personen)
  • DKF+ Davit-launched (12-35 Personen)
  • S30 Extended Service Interval (alle Kapazitäten)
  • RescYou Recreational Series (Yachting)
Common Failures & Inspection Points
  • Area: Jährliches Service-Intervall (SOLAS)
    Check: Inspekteur prüft auf Serviceetiketten-Datum (nicht älter als 12 Monate); Standard SOLAS erfordert vollständige Inspektion, Inflations-Test, Zylinder-Kontrolle, Ausrüstungs-Inventar (Pyrotechnik, Wasser, Rationen)
  • Area: HRU (Hydrostatic Release Unit) - Austausch maximal alle 24 Monate
    Check: Inspekteur verifiziert HRU-Verfallsdatum unabhängig vom Raft-Service-Datum; PSC prüft beide Daten separat; muss mit Raft-Modell kompatibel sein; Hammar H20 oder ähnliche zertifizierte Modelle verwenden
  • Area: Painter-Linie und Weak-Link-System
    Check: Inspekteur prüft: Painter permanent mit Schiff verbunden; Weak-Link korrekt an HRU angebracht; Weak-Link-Bruchfestigkeit 1.6-2.0 kN; rote Farbe und 30 ft (ca. 10m) Länge bei Throw-overboard; Befestigung muss Aufzugskraft aushalten und bei Schiffsuntergang unter Raft-Gewicht reißen
  • Area: Behälter-Integrität und Lashing-Straps
    Check: Inspekteur kontrolliert: Behälter auf Risse, Verformungen, Wasserschäden; Lashing-Straps fest und unbeschädigt; Wiege/Cradle sicher befestigt; Container horizontal stabil gelagert; Siegel intakt
  • Area: Davit-System Prüfung (nur DKF+-Modelle)
    Check: Inspekteur prüft: Davit mit Schnellen/Seilen verbunden; Raft-Anschlussgurte intakt; Laterale Impact-Prüfung: Raft muss Aufprall 3.5 m/s gegen Schiffswand aushalten; Wasser-Eintauch-Test aus 3m Höhe ohne Funktionsverlust; Launching-Muster dokumentieren
  • Area: S30 Extended Service Interval - Jährliche Bordsinspektion (30-Monate-Option)
    Check: Inspekteur (Crew) führt 3-Schritt-Bordsinspektion durch: Test-Panel für Umgebung in Aluminium-Beutel; Sichtprüfung Container; keine elektrische Ausrüstung nötig; vollständiger Service alle 30 Monate an zertifizierter Viking-Station (statt 12 Monate Standard); keine Interval-Verlängerungen möglich für S30

Typ-universelle Inspektions-/Wartungspunkte fuer Life Rafts (Viking Life-Saving Equipment, Mega-Schwarm 2026-06). Per-Modell-Specs nicht auto-gefuellt.

Viking Life-Saving Equipment Viking Life-Saving Equipment SOLAS-B Soft Valise 8P-B
Viking Life-Saving Equipment SOLAS-B Soft Valise 8P-B
Capacity (persons)
8
Packing
Soft Valise
Technical Specifications
Kapazitätsbereich
4 bis 35 Personen (DK+ & DKF+ Serien)
Behältertypen
Rund, Quadratisch, Low-Profile (Fiberglas)
Funktionstemperatur
-30°C bis +65°C (Standard); -50°C für Polar-Versionen
Inflation
Automatisch durch Painter-Linie oder CO2-Zylinder; Inflation innerhalb 1 Minute (Throw-overboard)
Notfall-packungen
SOLAS A (Standard) oder SOLAS B
Behälter-Material
Starrer Fiberglas-Container mit Schaumstoff-Polsterung
Stabilität
Zwei unabhängige Auftriebskammern; bleibt stabil auch bei einer deflatierten Kammer
Product Lines
  • DK+ Throw-overboard (4-35 Personen)
  • DKF+ Davit-launched (12-35 Personen)
  • S30 Extended Service Interval (alle Kapazitäten)
  • RescYou Recreational Series (Yachting)
Common Failures & Inspection Points
  • Area: Jährliches Service-Intervall (SOLAS)
    Check: Inspekteur prüft auf Serviceetiketten-Datum (nicht älter als 12 Monate); Standard SOLAS erfordert vollständige Inspektion, Inflations-Test, Zylinder-Kontrolle, Ausrüstungs-Inventar (Pyrotechnik, Wasser, Rationen)
  • Area: HRU (Hydrostatic Release Unit) - Austausch maximal alle 24 Monate
    Check: Inspekteur verifiziert HRU-Verfallsdatum unabhängig vom Raft-Service-Datum; PSC prüft beide Daten separat; muss mit Raft-Modell kompatibel sein; Hammar H20 oder ähnliche zertifizierte Modelle verwenden
  • Area: Painter-Linie und Weak-Link-System
    Check: Inspekteur prüft: Painter permanent mit Schiff verbunden; Weak-Link korrekt an HRU angebracht; Weak-Link-Bruchfestigkeit 1.6-2.0 kN; rote Farbe und 30 ft (ca. 10m) Länge bei Throw-overboard; Befestigung muss Aufzugskraft aushalten und bei Schiffsuntergang unter Raft-Gewicht reißen
  • Area: Behälter-Integrität und Lashing-Straps
    Check: Inspekteur kontrolliert: Behälter auf Risse, Verformungen, Wasserschäden; Lashing-Straps fest und unbeschädigt; Wiege/Cradle sicher befestigt; Container horizontal stabil gelagert; Siegel intakt
  • Area: Davit-System Prüfung (nur DKF+-Modelle)
    Check: Inspekteur prüft: Davit mit Schnellen/Seilen verbunden; Raft-Anschlussgurte intakt; Laterale Impact-Prüfung: Raft muss Aufprall 3.5 m/s gegen Schiffswand aushalten; Wasser-Eintauch-Test aus 3m Höhe ohne Funktionsverlust; Launching-Muster dokumentieren
  • Area: S30 Extended Service Interval - Jährliche Bordsinspektion (30-Monate-Option)
    Check: Inspekteur (Crew) führt 3-Schritt-Bordsinspektion durch: Test-Panel für Umgebung in Aluminium-Beutel; Sichtprüfung Container; keine elektrische Ausrüstung nötig; vollständiger Service alle 30 Monate an zertifizierter Viking-Station (statt 12 Monate Standard); keine Interval-Verlängerungen möglich für S30

Typ-universelle Inspektions-/Wartungspunkte fuer Life Rafts (Viking Life-Saving Equipment, Mega-Schwarm 2026-06). Per-Modell-Specs nicht auto-gefuellt.

Viking Life-Saving Equipment Viking Life-Saving Equipment SOLAS-B Soft Valise 10P-B
Viking Life-Saving Equipment SOLAS-B Soft Valise 10P-B
Capacity (persons)
10
Packing
Soft Valise
Technical Specifications
Kapazitätsbereich
4 bis 35 Personen (DK+ & DKF+ Serien)
Behältertypen
Rund, Quadratisch, Low-Profile (Fiberglas)
Funktionstemperatur
-30°C bis +65°C (Standard); -50°C für Polar-Versionen
Inflation
Automatisch durch Painter-Linie oder CO2-Zylinder; Inflation innerhalb 1 Minute (Throw-overboard)
Notfall-packungen
SOLAS A (Standard) oder SOLAS B
Behälter-Material
Starrer Fiberglas-Container mit Schaumstoff-Polsterung
Stabilität
Zwei unabhängige Auftriebskammern; bleibt stabil auch bei einer deflatierten Kammer
Product Lines
  • DK+ Throw-overboard (4-35 Personen)
  • DKF+ Davit-launched (12-35 Personen)
  • S30 Extended Service Interval (alle Kapazitäten)
  • RescYou Recreational Series (Yachting)
Common Failures & Inspection Points
  • Area: Jährliches Service-Intervall (SOLAS)
    Check: Inspekteur prüft auf Serviceetiketten-Datum (nicht älter als 12 Monate); Standard SOLAS erfordert vollständige Inspektion, Inflations-Test, Zylinder-Kontrolle, Ausrüstungs-Inventar (Pyrotechnik, Wasser, Rationen)
  • Area: HRU (Hydrostatic Release Unit) - Austausch maximal alle 24 Monate
    Check: Inspekteur verifiziert HRU-Verfallsdatum unabhängig vom Raft-Service-Datum; PSC prüft beide Daten separat; muss mit Raft-Modell kompatibel sein; Hammar H20 oder ähnliche zertifizierte Modelle verwenden
  • Area: Painter-Linie und Weak-Link-System
    Check: Inspekteur prüft: Painter permanent mit Schiff verbunden; Weak-Link korrekt an HRU angebracht; Weak-Link-Bruchfestigkeit 1.6-2.0 kN; rote Farbe und 30 ft (ca. 10m) Länge bei Throw-overboard; Befestigung muss Aufzugskraft aushalten und bei Schiffsuntergang unter Raft-Gewicht reißen
  • Area: Behälter-Integrität und Lashing-Straps
    Check: Inspekteur kontrolliert: Behälter auf Risse, Verformungen, Wasserschäden; Lashing-Straps fest und unbeschädigt; Wiege/Cradle sicher befestigt; Container horizontal stabil gelagert; Siegel intakt
  • Area: Davit-System Prüfung (nur DKF+-Modelle)
    Check: Inspekteur prüft: Davit mit Schnellen/Seilen verbunden; Raft-Anschlussgurte intakt; Laterale Impact-Prüfung: Raft muss Aufprall 3.5 m/s gegen Schiffswand aushalten; Wasser-Eintauch-Test aus 3m Höhe ohne Funktionsverlust; Launching-Muster dokumentieren
  • Area: S30 Extended Service Interval - Jährliche Bordsinspektion (30-Monate-Option)
    Check: Inspekteur (Crew) führt 3-Schritt-Bordsinspektion durch: Test-Panel für Umgebung in Aluminium-Beutel; Sichtprüfung Container; keine elektrische Ausrüstung nötig; vollständiger Service alle 30 Monate an zertifizierter Viking-Station (statt 12 Monate Standard); keine Interval-Verlängerungen möglich für S30

Typ-universelle Inspektions-/Wartungspunkte fuer Life Rafts (Viking Life-Saving Equipment, Mega-Schwarm 2026-06). Per-Modell-Specs nicht auto-gefuellt.

Viking Life-Saving Equipment Viking Life-Saving Equipment SOLAS-B Soft Valise 12P-B
Viking Life-Saving Equipment SOLAS-B Soft Valise 12P-B
Capacity (persons)
12
Packing
Soft Valise
Technical Specifications
Kapazitätsbereich
4 bis 35 Personen (DK+ & DKF+ Serien)
Behältertypen
Rund, Quadratisch, Low-Profile (Fiberglas)
Funktionstemperatur
-30°C bis +65°C (Standard); -50°C für Polar-Versionen
Inflation
Automatisch durch Painter-Linie oder CO2-Zylinder; Inflation innerhalb 1 Minute (Throw-overboard)
Notfall-packungen
SOLAS A (Standard) oder SOLAS B
Behälter-Material
Starrer Fiberglas-Container mit Schaumstoff-Polsterung
Stabilität
Zwei unabhängige Auftriebskammern; bleibt stabil auch bei einer deflatierten Kammer
Product Lines
  • DK+ Throw-overboard (4-35 Personen)
  • DKF+ Davit-launched (12-35 Personen)
  • S30 Extended Service Interval (alle Kapazitäten)
  • RescYou Recreational Series (Yachting)
Common Failures & Inspection Points
  • Area: Jährliches Service-Intervall (SOLAS)
    Check: Inspekteur prüft auf Serviceetiketten-Datum (nicht älter als 12 Monate); Standard SOLAS erfordert vollständige Inspektion, Inflations-Test, Zylinder-Kontrolle, Ausrüstungs-Inventar (Pyrotechnik, Wasser, Rationen)
  • Area: HRU (Hydrostatic Release Unit) - Austausch maximal alle 24 Monate
    Check: Inspekteur verifiziert HRU-Verfallsdatum unabhängig vom Raft-Service-Datum; PSC prüft beide Daten separat; muss mit Raft-Modell kompatibel sein; Hammar H20 oder ähnliche zertifizierte Modelle verwenden
  • Area: Painter-Linie und Weak-Link-System
    Check: Inspekteur prüft: Painter permanent mit Schiff verbunden; Weak-Link korrekt an HRU angebracht; Weak-Link-Bruchfestigkeit 1.6-2.0 kN; rote Farbe und 30 ft (ca. 10m) Länge bei Throw-overboard; Befestigung muss Aufzugskraft aushalten und bei Schiffsuntergang unter Raft-Gewicht reißen
  • Area: Behälter-Integrität und Lashing-Straps
    Check: Inspekteur kontrolliert: Behälter auf Risse, Verformungen, Wasserschäden; Lashing-Straps fest und unbeschädigt; Wiege/Cradle sicher befestigt; Container horizontal stabil gelagert; Siegel intakt
  • Area: Davit-System Prüfung (nur DKF+-Modelle)
    Check: Inspekteur prüft: Davit mit Schnellen/Seilen verbunden; Raft-Anschlussgurte intakt; Laterale Impact-Prüfung: Raft muss Aufprall 3.5 m/s gegen Schiffswand aushalten; Wasser-Eintauch-Test aus 3m Höhe ohne Funktionsverlust; Launching-Muster dokumentieren
  • Area: S30 Extended Service Interval - Jährliche Bordsinspektion (30-Monate-Option)
    Check: Inspekteur (Crew) führt 3-Schritt-Bordsinspektion durch: Test-Panel für Umgebung in Aluminium-Beutel; Sichtprüfung Container; keine elektrische Ausrüstung nötig; vollständiger Service alle 30 Monate an zertifizierter Viking-Station (statt 12 Monate Standard); keine Interval-Verlängerungen möglich für S30

Typ-universelle Inspektions-/Wartungspunkte fuer Life Rafts (Viking Life-Saving Equipment, Mega-Schwarm 2026-06). Per-Modell-Specs nicht auto-gefuellt.

Viking Life-Saving Equipment Viking Life-Saving Equipment SOLAS-B Rigid Container 4P-B
Viking Life-Saving Equipment SOLAS-B Rigid Container 4P-B
Capacity (persons)
4
Packing
Rigid Container
Technical Specifications
Kapazitätsbereich
4 bis 35 Personen (DK+ & DKF+ Serien)
Behältertypen
Rund, Quadratisch, Low-Profile (Fiberglas)
Funktionstemperatur
-30°C bis +65°C (Standard); -50°C für Polar-Versionen
Inflation
Automatisch durch Painter-Linie oder CO2-Zylinder; Inflation innerhalb 1 Minute (Throw-overboard)
Notfall-packungen
SOLAS A (Standard) oder SOLAS B
Behälter-Material
Starrer Fiberglas-Container mit Schaumstoff-Polsterung
Stabilität
Zwei unabhängige Auftriebskammern; bleibt stabil auch bei einer deflatierten Kammer
Product Lines
  • DK+ Throw-overboard (4-35 Personen)
  • DKF+ Davit-launched (12-35 Personen)
  • S30 Extended Service Interval (alle Kapazitäten)
  • RescYou Recreational Series (Yachting)
Common Failures & Inspection Points
  • Area: Jährliches Service-Intervall (SOLAS)
    Check: Inspekteur prüft auf Serviceetiketten-Datum (nicht älter als 12 Monate); Standard SOLAS erfordert vollständige Inspektion, Inflations-Test, Zylinder-Kontrolle, Ausrüstungs-Inventar (Pyrotechnik, Wasser, Rationen)
  • Area: HRU (Hydrostatic Release Unit) - Austausch maximal alle 24 Monate
    Check: Inspekteur verifiziert HRU-Verfallsdatum unabhängig vom Raft-Service-Datum; PSC prüft beide Daten separat; muss mit Raft-Modell kompatibel sein; Hammar H20 oder ähnliche zertifizierte Modelle verwenden
  • Area: Painter-Linie und Weak-Link-System
    Check: Inspekteur prüft: Painter permanent mit Schiff verbunden; Weak-Link korrekt an HRU angebracht; Weak-Link-Bruchfestigkeit 1.6-2.0 kN; rote Farbe und 30 ft (ca. 10m) Länge bei Throw-overboard; Befestigung muss Aufzugskraft aushalten und bei Schiffsuntergang unter Raft-Gewicht reißen
  • Area: Behälter-Integrität und Lashing-Straps
    Check: Inspekteur kontrolliert: Behälter auf Risse, Verformungen, Wasserschäden; Lashing-Straps fest und unbeschädigt; Wiege/Cradle sicher befestigt; Container horizontal stabil gelagert; Siegel intakt
  • Area: Davit-System Prüfung (nur DKF+-Modelle)
    Check: Inspekteur prüft: Davit mit Schnellen/Seilen verbunden; Raft-Anschlussgurte intakt; Laterale Impact-Prüfung: Raft muss Aufprall 3.5 m/s gegen Schiffswand aushalten; Wasser-Eintauch-Test aus 3m Höhe ohne Funktionsverlust; Launching-Muster dokumentieren
  • Area: S30 Extended Service Interval - Jährliche Bordsinspektion (30-Monate-Option)
    Check: Inspekteur (Crew) führt 3-Schritt-Bordsinspektion durch: Test-Panel für Umgebung in Aluminium-Beutel; Sichtprüfung Container; keine elektrische Ausrüstung nötig; vollständiger Service alle 30 Monate an zertifizierter Viking-Station (statt 12 Monate Standard); keine Interval-Verlängerungen möglich für S30

Typ-universelle Inspektions-/Wartungspunkte fuer Life Rafts (Viking Life-Saving Equipment, Mega-Schwarm 2026-06). Per-Modell-Specs nicht auto-gefuellt.

Viking Life-Saving Equipment Viking Life-Saving Equipment SOLAS-B Rigid Container 6P-B
Viking Life-Saving Equipment SOLAS-B Rigid Container 6P-B
Capacity (persons)
6
Packing
Rigid Container
Technical Specifications
Kapazitätsbereich
4 bis 35 Personen (DK+ & DKF+ Serien)
Behältertypen
Rund, Quadratisch, Low-Profile (Fiberglas)
Funktionstemperatur
-30°C bis +65°C (Standard); -50°C für Polar-Versionen
Inflation
Automatisch durch Painter-Linie oder CO2-Zylinder; Inflation innerhalb 1 Minute (Throw-overboard)
Notfall-packungen
SOLAS A (Standard) oder SOLAS B
Behälter-Material
Starrer Fiberglas-Container mit Schaumstoff-Polsterung
Stabilität
Zwei unabhängige Auftriebskammern; bleibt stabil auch bei einer deflatierten Kammer
Product Lines
  • DK+ Throw-overboard (4-35 Personen)
  • DKF+ Davit-launched (12-35 Personen)
  • S30 Extended Service Interval (alle Kapazitäten)
  • RescYou Recreational Series (Yachting)
Common Failures & Inspection Points
  • Area: Jährliches Service-Intervall (SOLAS)
    Check: Inspekteur prüft auf Serviceetiketten-Datum (nicht älter als 12 Monate); Standard SOLAS erfordert vollständige Inspektion, Inflations-Test, Zylinder-Kontrolle, Ausrüstungs-Inventar (Pyrotechnik, Wasser, Rationen)
  • Area: HRU (Hydrostatic Release Unit) - Austausch maximal alle 24 Monate
    Check: Inspekteur verifiziert HRU-Verfallsdatum unabhängig vom Raft-Service-Datum; PSC prüft beide Daten separat; muss mit Raft-Modell kompatibel sein; Hammar H20 oder ähnliche zertifizierte Modelle verwenden
  • Area: Painter-Linie und Weak-Link-System
    Check: Inspekteur prüft: Painter permanent mit Schiff verbunden; Weak-Link korrekt an HRU angebracht; Weak-Link-Bruchfestigkeit 1.6-2.0 kN; rote Farbe und 30 ft (ca. 10m) Länge bei Throw-overboard; Befestigung muss Aufzugskraft aushalten und bei Schiffsuntergang unter Raft-Gewicht reißen
  • Area: Behälter-Integrität und Lashing-Straps
    Check: Inspekteur kontrolliert: Behälter auf Risse, Verformungen, Wasserschäden; Lashing-Straps fest und unbeschädigt; Wiege/Cradle sicher befestigt; Container horizontal stabil gelagert; Siegel intakt
  • Area: Davit-System Prüfung (nur DKF+-Modelle)
    Check: Inspekteur prüft: Davit mit Schnellen/Seilen verbunden; Raft-Anschlussgurte intakt; Laterale Impact-Prüfung: Raft muss Aufprall 3.5 m/s gegen Schiffswand aushalten; Wasser-Eintauch-Test aus 3m Höhe ohne Funktionsverlust; Launching-Muster dokumentieren
  • Area: S30 Extended Service Interval - Jährliche Bordsinspektion (30-Monate-Option)
    Check: Inspekteur (Crew) führt 3-Schritt-Bordsinspektion durch: Test-Panel für Umgebung in Aluminium-Beutel; Sichtprüfung Container; keine elektrische Ausrüstung nötig; vollständiger Service alle 30 Monate an zertifizierter Viking-Station (statt 12 Monate Standard); keine Interval-Verlängerungen möglich für S30

Typ-universelle Inspektions-/Wartungspunkte fuer Life Rafts (Viking Life-Saving Equipment, Mega-Schwarm 2026-06). Per-Modell-Specs nicht auto-gefuellt.

Viking Life-Saving Equipment Viking Life-Saving Equipment SOLAS-B Rigid Container 8P-B
Viking Life-Saving Equipment SOLAS-B Rigid Container 8P-B
Capacity (persons)
8
Packing
Rigid Container
Technical Specifications
Kapazitätsbereich
4 bis 35 Personen (DK+ & DKF+ Serien)
Behältertypen
Rund, Quadratisch, Low-Profile (Fiberglas)
Funktionstemperatur
-30°C bis +65°C (Standard); -50°C für Polar-Versionen
Inflation
Automatisch durch Painter-Linie oder CO2-Zylinder; Inflation innerhalb 1 Minute (Throw-overboard)
Notfall-packungen
SOLAS A (Standard) oder SOLAS B
Behälter-Material
Starrer Fiberglas-Container mit Schaumstoff-Polsterung
Stabilität
Zwei unabhängige Auftriebskammern; bleibt stabil auch bei einer deflatierten Kammer
Product Lines
  • DK+ Throw-overboard (4-35 Personen)
  • DKF+ Davit-launched (12-35 Personen)
  • S30 Extended Service Interval (alle Kapazitäten)
  • RescYou Recreational Series (Yachting)
Common Failures & Inspection Points
  • Area: Jährliches Service-Intervall (SOLAS)
    Check: Inspekteur prüft auf Serviceetiketten-Datum (nicht älter als 12 Monate); Standard SOLAS erfordert vollständige Inspektion, Inflations-Test, Zylinder-Kontrolle, Ausrüstungs-Inventar (Pyrotechnik, Wasser, Rationen)
  • Area: HRU (Hydrostatic Release Unit) - Austausch maximal alle 24 Monate
    Check: Inspekteur verifiziert HRU-Verfallsdatum unabhängig vom Raft-Service-Datum; PSC prüft beide Daten separat; muss mit Raft-Modell kompatibel sein; Hammar H20 oder ähnliche zertifizierte Modelle verwenden
  • Area: Painter-Linie und Weak-Link-System
    Check: Inspekteur prüft: Painter permanent mit Schiff verbunden; Weak-Link korrekt an HRU angebracht; Weak-Link-Bruchfestigkeit 1.6-2.0 kN; rote Farbe und 30 ft (ca. 10m) Länge bei Throw-overboard; Befestigung muss Aufzugskraft aushalten und bei Schiffsuntergang unter Raft-Gewicht reißen
  • Area: Behälter-Integrität und Lashing-Straps
    Check: Inspekteur kontrolliert: Behälter auf Risse, Verformungen, Wasserschäden; Lashing-Straps fest und unbeschädigt; Wiege/Cradle sicher befestigt; Container horizontal stabil gelagert; Siegel intakt
  • Area: Davit-System Prüfung (nur DKF+-Modelle)
    Check: Inspekteur prüft: Davit mit Schnellen/Seilen verbunden; Raft-Anschlussgurte intakt; Laterale Impact-Prüfung: Raft muss Aufprall 3.5 m/s gegen Schiffswand aushalten; Wasser-Eintauch-Test aus 3m Höhe ohne Funktionsverlust; Launching-Muster dokumentieren
  • Area: S30 Extended Service Interval - Jährliche Bordsinspektion (30-Monate-Option)
    Check: Inspekteur (Crew) führt 3-Schritt-Bordsinspektion durch: Test-Panel für Umgebung in Aluminium-Beutel; Sichtprüfung Container; keine elektrische Ausrüstung nötig; vollständiger Service alle 30 Monate an zertifizierter Viking-Station (statt 12 Monate Standard); keine Interval-Verlängerungen möglich für S30

Typ-universelle Inspektions-/Wartungspunkte fuer Life Rafts (Viking Life-Saving Equipment, Mega-Schwarm 2026-06). Per-Modell-Specs nicht auto-gefuellt.

Viking Life-Saving Equipment Viking Life-Saving Equipment SOLAS-B Rigid Container 10P-B
Viking Life-Saving Equipment SOLAS-B Rigid Container 10P-B
Capacity (persons)
10
Packing
Rigid Container
Technical Specifications
Kapazitätsbereich
4 bis 35 Personen (DK+ & DKF+ Serien)
Behältertypen
Rund, Quadratisch, Low-Profile (Fiberglas)
Funktionstemperatur
-30°C bis +65°C (Standard); -50°C für Polar-Versionen
Inflation
Automatisch durch Painter-Linie oder CO2-Zylinder; Inflation innerhalb 1 Minute (Throw-overboard)
Notfall-packungen
SOLAS A (Standard) oder SOLAS B
Behälter-Material
Starrer Fiberglas-Container mit Schaumstoff-Polsterung
Stabilität
Zwei unabhängige Auftriebskammern; bleibt stabil auch bei einer deflatierten Kammer
Product Lines
  • DK+ Throw-overboard (4-35 Personen)
  • DKF+ Davit-launched (12-35 Personen)
  • S30 Extended Service Interval (alle Kapazitäten)
  • RescYou Recreational Series (Yachting)
Common Failures & Inspection Points
  • Area: Jährliches Service-Intervall (SOLAS)
    Check: Inspekteur prüft auf Serviceetiketten-Datum (nicht älter als 12 Monate); Standard SOLAS erfordert vollständige Inspektion, Inflations-Test, Zylinder-Kontrolle, Ausrüstungs-Inventar (Pyrotechnik, Wasser, Rationen)
  • Area: HRU (Hydrostatic Release Unit) - Austausch maximal alle 24 Monate
    Check: Inspekteur verifiziert HRU-Verfallsdatum unabhängig vom Raft-Service-Datum; PSC prüft beide Daten separat; muss mit Raft-Modell kompatibel sein; Hammar H20 oder ähnliche zertifizierte Modelle verwenden
  • Area: Painter-Linie und Weak-Link-System
    Check: Inspekteur prüft: Painter permanent mit Schiff verbunden; Weak-Link korrekt an HRU angebracht; Weak-Link-Bruchfestigkeit 1.6-2.0 kN; rote Farbe und 30 ft (ca. 10m) Länge bei Throw-overboard; Befestigung muss Aufzugskraft aushalten und bei Schiffsuntergang unter Raft-Gewicht reißen
  • Area: Behälter-Integrität und Lashing-Straps
    Check: Inspekteur kontrolliert: Behälter auf Risse, Verformungen, Wasserschäden; Lashing-Straps fest und unbeschädigt; Wiege/Cradle sicher befestigt; Container horizontal stabil gelagert; Siegel intakt
  • Area: Davit-System Prüfung (nur DKF+-Modelle)
    Check: Inspekteur prüft: Davit mit Schnellen/Seilen verbunden; Raft-Anschlussgurte intakt; Laterale Impact-Prüfung: Raft muss Aufprall 3.5 m/s gegen Schiffswand aushalten; Wasser-Eintauch-Test aus 3m Höhe ohne Funktionsverlust; Launching-Muster dokumentieren
  • Area: S30 Extended Service Interval - Jährliche Bordsinspektion (30-Monate-Option)
    Check: Inspekteur (Crew) führt 3-Schritt-Bordsinspektion durch: Test-Panel für Umgebung in Aluminium-Beutel; Sichtprüfung Container; keine elektrische Ausrüstung nötig; vollständiger Service alle 30 Monate an zertifizierter Viking-Station (statt 12 Monate Standard); keine Interval-Verlängerungen möglich für S30

Typ-universelle Inspektions-/Wartungspunkte fuer Life Rafts (Viking Life-Saving Equipment, Mega-Schwarm 2026-06). Per-Modell-Specs nicht auto-gefuellt.

Viking Life-Saving Equipment Viking Life-Saving Equipment SOLAS-B Rigid Container 12P-B
Viking Life-Saving Equipment SOLAS-B Rigid Container 12P-B
Capacity (persons)
12
Packing
Rigid Container
Technical Specifications
Kapazitätsbereich
4 bis 35 Personen (DK+ & DKF+ Serien)
Behältertypen
Rund, Quadratisch, Low-Profile (Fiberglas)
Funktionstemperatur
-30°C bis +65°C (Standard); -50°C für Polar-Versionen
Inflation
Automatisch durch Painter-Linie oder CO2-Zylinder; Inflation innerhalb 1 Minute (Throw-overboard)
Notfall-packungen
SOLAS A (Standard) oder SOLAS B
Behälter-Material
Starrer Fiberglas-Container mit Schaumstoff-Polsterung
Stabilität
Zwei unabhängige Auftriebskammern; bleibt stabil auch bei einer deflatierten Kammer
Product Lines
  • DK+ Throw-overboard (4-35 Personen)
  • DKF+ Davit-launched (12-35 Personen)
  • S30 Extended Service Interval (alle Kapazitäten)
  • RescYou Recreational Series (Yachting)
Common Failures & Inspection Points
  • Area: Jährliches Service-Intervall (SOLAS)
    Check: Inspekteur prüft auf Serviceetiketten-Datum (nicht älter als 12 Monate); Standard SOLAS erfordert vollständige Inspektion, Inflations-Test, Zylinder-Kontrolle, Ausrüstungs-Inventar (Pyrotechnik, Wasser, Rationen)
  • Area: HRU (Hydrostatic Release Unit) - Austausch maximal alle 24 Monate
    Check: Inspekteur verifiziert HRU-Verfallsdatum unabhängig vom Raft-Service-Datum; PSC prüft beide Daten separat; muss mit Raft-Modell kompatibel sein; Hammar H20 oder ähnliche zertifizierte Modelle verwenden
  • Area: Painter-Linie und Weak-Link-System
    Check: Inspekteur prüft: Painter permanent mit Schiff verbunden; Weak-Link korrekt an HRU angebracht; Weak-Link-Bruchfestigkeit 1.6-2.0 kN; rote Farbe und 30 ft (ca. 10m) Länge bei Throw-overboard; Befestigung muss Aufzugskraft aushalten und bei Schiffsuntergang unter Raft-Gewicht reißen
  • Area: Behälter-Integrität und Lashing-Straps
    Check: Inspekteur kontrolliert: Behälter auf Risse, Verformungen, Wasserschäden; Lashing-Straps fest und unbeschädigt; Wiege/Cradle sicher befestigt; Container horizontal stabil gelagert; Siegel intakt
  • Area: Davit-System Prüfung (nur DKF+-Modelle)
    Check: Inspekteur prüft: Davit mit Schnellen/Seilen verbunden; Raft-Anschlussgurte intakt; Laterale Impact-Prüfung: Raft muss Aufprall 3.5 m/s gegen Schiffswand aushalten; Wasser-Eintauch-Test aus 3m Höhe ohne Funktionsverlust; Launching-Muster dokumentieren
  • Area: S30 Extended Service Interval - Jährliche Bordsinspektion (30-Monate-Option)
    Check: Inspekteur (Crew) führt 3-Schritt-Bordsinspektion durch: Test-Panel für Umgebung in Aluminium-Beutel; Sichtprüfung Container; keine elektrische Ausrüstung nötig; vollständiger Service alle 30 Monate an zertifizierter Viking-Station (statt 12 Monate Standard); keine Interval-Verlängerungen möglich für S30

Typ-universelle Inspektions-/Wartungspunkte fuer Life Rafts (Viking Life-Saving Equipment, Mega-Schwarm 2026-06). Per-Modell-Specs nicht auto-gefuellt.

Crewsaver / Survitec

15
Crewsaver / Survitec Crewsaver ISO 4P
Crewsaver ISO 4P unverified
Capacity (persons)
4
Crewsaver / Survitec Crewsaver ISO 6P
Crewsaver ISO 6P unverified
Capacity (persons)
6
Crewsaver / Survitec Crewsaver ISO 8P
Crewsaver ISO 8P unverified
Capacity (persons)
8
Crewsaver / Survitec Crewsaver ISO 10P
Crewsaver ISO 10P unverified
Capacity (persons)
10
Crewsaver / Survitec Crewsaver ISO 12P
Crewsaver ISO 12P unverified
Capacity (persons)
12
Crewsaver / Survitec Crewsaver SOLAS-B Soft Valise 4P-B
Crewsaver SOLAS-B Soft Valise 4P-B unverified
Capacity (persons)
4
Packing
Soft Valise
Crewsaver / Survitec Crewsaver SOLAS-B Soft Valise 6P-B
Crewsaver SOLAS-B Soft Valise 6P-B unverified
Capacity (persons)
6
Packing
Soft Valise
Crewsaver / Survitec Crewsaver SOLAS-B Soft Valise 8P-B
Crewsaver SOLAS-B Soft Valise 8P-B unverified
Capacity (persons)
8
Packing
Soft Valise
Crewsaver / Survitec Crewsaver SOLAS-B Soft Valise 10P-B
Crewsaver SOLAS-B Soft Valise 10P-B unverified
Capacity (persons)
10
Packing
Soft Valise
Crewsaver / Survitec Crewsaver SOLAS-B Soft Valise 12P-B
Crewsaver SOLAS-B Soft Valise 12P-B unverified
Capacity (persons)
12
Packing
Soft Valise
Crewsaver / Survitec Crewsaver SOLAS-B Rigid Container 4P-B
Crewsaver SOLAS-B Rigid Container 4P-B unverified
Capacity (persons)
4
Packing
Rigid Container
Crewsaver / Survitec Crewsaver SOLAS-B Rigid Container 6P-B
Crewsaver SOLAS-B Rigid Container 6P-B unverified
Capacity (persons)
6
Packing
Rigid Container
Crewsaver / Survitec Crewsaver SOLAS-B Rigid Container 8P-B
Crewsaver SOLAS-B Rigid Container 8P-B unverified
Capacity (persons)
8
Packing
Rigid Container
Crewsaver / Survitec Crewsaver SOLAS-B Rigid Container 10P-B
Crewsaver SOLAS-B Rigid Container 10P-B unverified
Capacity (persons)
10
Packing
Rigid Container
Crewsaver / Survitec Crewsaver SOLAS-B Rigid Container 12P-B
Crewsaver SOLAS-B Rigid Container 12P-B unverified
Capacity (persons)
12
Packing
Rigid Container

Lalizas

15
Lalizas Lalizas ISO 4P
Lalizas ISO 4P unverified
Capacity (persons)
4
Lalizas Lalizas ISO 6P
Lalizas ISO 6P unverified
Capacity (persons)
6
Lalizas Lalizas ISO 8P
Lalizas ISO 8P unverified
Capacity (persons)
8
Lalizas Lalizas ISO 10P
Lalizas ISO 10P unverified
Capacity (persons)
10
Lalizas Lalizas ISO 12P
Lalizas ISO 12P unverified
Capacity (persons)
12
Lalizas Lalizas SOLAS-B Soft Valise 4P-B
Lalizas SOLAS-B Soft Valise 4P-B unverified
Capacity (persons)
4
Packing
Soft Valise
Lalizas Lalizas SOLAS-B Soft Valise 6P-B
Lalizas SOLAS-B Soft Valise 6P-B unverified
Capacity (persons)
6
Packing
Soft Valise
Lalizas Lalizas SOLAS-B Soft Valise 8P-B
Lalizas SOLAS-B Soft Valise 8P-B unverified
Capacity (persons)
8
Packing
Soft Valise
Lalizas Lalizas SOLAS-B Soft Valise 10P-B
Lalizas SOLAS-B Soft Valise 10P-B unverified
Capacity (persons)
10
Packing
Soft Valise
Lalizas Lalizas SOLAS-B Soft Valise 12P-B
Lalizas SOLAS-B Soft Valise 12P-B unverified
Capacity (persons)
12
Packing
Soft Valise
Lalizas Lalizas SOLAS-B Rigid Container 4P-B
Lalizas SOLAS-B Rigid Container 4P-B unverified
Capacity (persons)
4
Packing
Rigid Container
Lalizas Lalizas SOLAS-B Rigid Container 6P-B
Lalizas SOLAS-B Rigid Container 6P-B unverified
Capacity (persons)
6
Packing
Rigid Container
Lalizas Lalizas SOLAS-B Rigid Container 8P-B
Lalizas SOLAS-B Rigid Container 8P-B unverified
Capacity (persons)
8
Packing
Rigid Container
Lalizas Lalizas SOLAS-B Rigid Container 10P-B
Lalizas SOLAS-B Rigid Container 10P-B unverified
Capacity (persons)
10
Packing
Rigid Container
Lalizas Lalizas SOLAS-B Rigid Container 12P-B
Lalizas SOLAS-B Rigid Container 12P-B unverified
Capacity (persons)
12
Packing
Rigid Container

DSB Marine

7
DSB Marine DSB SOLAS-B 6P
DSB SOLAS-B 6P unverified
Capacity (persons)
6
DSB Marine DSB SOLAS-B 8P
DSB SOLAS-B 8P unverified
Capacity (persons)
8
DSB Marine DSB SOLAS-B 10P
DSB SOLAS-B 10P unverified
Capacity (persons)
10
DSB Marine DSB SOLAS-B 12P
DSB SOLAS-B 12P unverified
Capacity (persons)
12
DSB Marine DSB SOLAS-B 16P
DSB SOLAS-B 16P unverified
Capacity (persons)
16
DSB Marine DSB SOLAS-B 20P
DSB SOLAS-B 20P unverified
Capacity (persons)
20
DSB Marine DSB SOLAS-B 25P
DSB SOLAS-B 25P unverified
Capacity (persons)
25