OceanSphere
Engines
⚓ Working on this equipment?
Ask the AI troubleshooter, log your hours on board and turn them into invoice-ready service reports — for this exact model.
Start free — 14 days →
No credit card required
🔧 4 verified suppliers & service companies for Seago Ltd in the Maritime Network Find suppliers →
Seago Ltd

SOLAS B - 6 Man Cylinder

Seago Ltd SOLAS B - 6 Man Cylinder — Offshore sailing on coded craft - Coastal configuration (SOLAS B pack).

Components & Design

Component data being added…

Technical Data

capacity persons 6
SOLAS approval SOLAS B
length m 1.05
weight kg 73

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Annual servicing by approved service stations at intervals not exceeding 12 months (per SOLAS III/20.8.1)

Annual servicing by approved service stations at intervals not exceeding 12 months (per SOLAS III/20.8.1)

Visual inspection of canopy, grab lines, buoyancy chambers, and all seams for integrity and fabric damage

Visual inspection of canopy, grab lines, buoyancy chambers, and all seams for integrity and fabric damage

Examination of seam connections (floor-to-buoyancy tube) for slippage, rupture, and lifting of edges

Examination of seam connections (floor-to-buoyancy tube) for slippage, rupture, and lifting of edges

Verification and replacement of expired pyrotechnics, water rations, and emergency food supplies

Verification and replacement of expired pyrotechnics, water rations, and emergency food supplies

Functional testing of mechanical components: inflation/deflation cylinders, pressure relief valves, boarding ramps

Functional testing of mechanical components: inflation/deflation cylinders, pressure relief valves, boarding ramps

Inspection and verification of retro-reflective tape condition and adhesion (canopy perimeter and floor cross pattern)

Inspection and verification of retro-reflective tape condition and adhesion (canopy perimeter and floor cross pattern)

Pressure-retention test on buoyancy chambers: minimum 5% pressure loss tolerance over 5 minutes after inflation

Pressure-retention test on buoyancy chambers: minimum 5% pressure loss tolerance over 5 minutes after inflation

Inspection of inflation cylinder condition, hydrostatic testing, and cylinder weight verification (recharge if >5% weight loss)

Inspection of inflation cylinder condition, hydrostatic testing, and cylinder weight verification (recharge if >5% weight loss)

Type-general inspection and maintenance points for this equipment category — not model-specific.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →
Equipment Model #151568 · ✓ still in production

Need spare parts for this model?

We know 4+ companies supplying Seago Ltd SOLASB-6MANCYLINDER. Tell us what you need — we obtain the quotations for you.

Gibyachts Pinmar Yacht Supply Reta · GibraltarSeago Shipping CorpSeago Yachting Ltd. · United KingdomNorfolk Marine · United Kingdom