OceanSphereFree accountLog inDEENPL
OceanSphereENGINES
Library› Cargo› Inert Gas Systems› Nitrogen Generator (Membrane)› Parker Hannifin Marine N2 Membrane N2-200 97%

N2 Membrane N2-200 97%

Nitrogen Generator (Membrane) · Inert Gas Systems

Class-certified type (DNV register) · technical data sheet not yet verified

Parker Hannifin Marine N2 Membrane N2-200 97% — 2200 m³/h capacity.

Specifications

Technical data.reference — unverified

Do you have the manufacturer datasheet for this model? Send it with the enquiry form — we check it and name the source.

Capacity (m³/h)2200
Oxygen Content (%)3
Dew Point (°C)-40
Inert Gas Systemmembrane N2
Inspection

Inspector Detail

Common issues

  • Reduced N2 purity from feed air contamination (oil carryover from the compressor)
  • Membrane fibre fouling from moisture or oil aerosols, shortening membrane life
  • Pre-filter/coalescing filter elements clogging, raising differential pressure
  • Feed air compressor undersized or worn, reducing achievable purity/flow
  • Condensate drain traps failing, allowing water ingress to the membrane bundle
  • Feed air temperature outside the membrane's rated window, reducing separation efficiency

Inspection checklist

  • Check feed air pressure and temperature at membrane inlet against nameplate values
  • Check O2 analyzer calibration and function
  • Inspect pre-filters/coalescing filters and note differential pressure trend
  • Check condensate drains and traps operate correctly
  • Verify feed air compressor oil carryover is within the membrane maker's limits
  • Log N2 purity and flow rate trend over time
  • Check membrane housing for external leaks or corrosion
  • Confirm downstream distribution and non-return valves operate correctly

Service intervals

Pre-filter/coalescing filter elementstypically every 4,000-8,000 running hours or on differential pressure alarm, whichever comes first - confirm against the maker's manual
O2 analyzer sensorreplace every 6-12 months, sensor is a consumable
Feed air compressor serviceper the compressor manufacturer's own schedule
Condensate drain/trap checkmonthly running check

Typical wear limits

Filter differential pressurereplace the element as it approaches the manufacturer's stated alarm/trip value - the exact figure depends on filter grade, check the filter's own dataplate
Product gas O2 contentshould track within the stated spec (approx. 3% O2 for 97% N2) at rated flow - persistent drift beyond spec points to membrane or filter degradation

Ranges are typical for this design class. Always confirm against the manufacturer documentation for your serial number.

Critical spares

  • Pre-filter element set (particulate and coalescing)
  • O2 analyzer sensor/cell
  • Condensate drain trap/solenoid
  • Feed air pressure regulator
  • Membrane bundle (long lead item, order in advance)

Safety

  • Discharge/vent lines can create an oxygen-deficient atmosphere in enclosed spaces - confined space precautions apply
  • Spaces placed under N2-enriched atmosphere require atmosphere testing before entry
  • Oil-contaminated feed air is a fire risk if it reaches downstream components not rated for it

Class survey

Where the N2 generator feeds a classed inert gas or tank atmosphere control system, class checks O2 analyzer calibration records, filter maintenance log, and a functional demonstration at Continuous Machinery Survey / IGS annual survey; keep purity and flow trend logs available for the surveyor.

Estimated lifetime: Membrane bundle life is typically several years of continuous service under clean, dry, oil-free feed air (often quoted in the 5-10 year range by membrane makers), but is highly sensitive to feed air quality - confirm against Parker's own membrane life data.

Need this part?

Request a quote for this model.

Free of charge — send us your request for Parker Hannifin Marine equipment. Our team checks it and replies by e-mail.

Makers and authorised dealers rarely quote marine equipment without the vessel. With these details we can check availability and prices faster; without them we may have to ask first, which can cost a few days. If you cannot share the vessel, a photo of the equipment’s rating plate does the same job — attach it below or send it as a reply to our confirmation e-mail.

Your contact details are not published. No account required.
Related models

Also in Nitrogen Generator (Membrane).

Other models of the same equipment type, Parker Hannifin Marine first.

By manufacturer Wartsila MossParker Hannifin MarineAir Products MarineMahler AGSSAACKEGeneronPanasiaSurvitecParker BalstonHanla IMSAlfa LavalParker (Domnick Hunter)All manufacturersSpare parts by equipmentNew here? Create a free account Can't read the plate? Try the nameplate scanner All Parker Hannifin Marine models More like N2 Membrane N2-200 97%
Would you like to know more?

A person reads every request and replies by e-mail.

Tell us what you need for this Parker Hannifin Marine N2 Membrane N2-200 97% — a part, a service call, a second opinion. Are you Parker Hannifin Marine? Claim this brand page.

Service engineer? Write the day report for this N2 Membrane N2-200 97% in OceanSphere Work — photos, hours and parts, as a PDF for the owner. Try it free for 14 days →

Frequently asked

Three things people ask first.

Is this model's data free?

Yes. Specifications, documents and service notes for this model are readable without an account. An account adds saved searches and requests, nothing is taken away.

Can you find a part for this exact model?

Yes. Tell us the manufacturer, the model and what you need — a person reads every request and replies by e-mail.

The specifications look wrong — what now?

Send us the nameplate or the correct value. We check it against the manufacturer datasheet or class-society record and update the page.