Sabroe (Johnson Controls)

Sabroe SAB 128 200/10

Sabroe (Johnson Controls) Sabroe SAB 128 200/10 is listed as a marine refrigeration compressor in the Compressors / Refrigeration Compressor category. Equipment of this class is typically installed in a refrigeration machinery room, provision plant, reefer system, HVAC chiller, or cargo refrigeration installation. Its shipboard purpose is to compress refrigerant vapor and maintain circulation through the refrigeration cycle. The exact piping, electrical, control, foundation, and accessory arrangement depends on the vessel and the supplied configuration. No additional verified rating, capacity, weight, dimension, or other model-specific figure is supplied in the structured source data. Any differences from adjacent models in the same family, including rating, size, material, control, certification, or accessory differences not explicitly listed here, should be confirmed in the manufacturer documentation.

Sabroe (Johnson Controls) Sabroe SAB 128 200/10

Components & Design

Component data being added…

Technical Data

compressor type refrigeration_compressor
pressure bar 10
capacity nm3h 200
refrigerant R717

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Refrigerant leakage from shaft seals, gaskets, valves, or piping causes reduced charge, poor cooling, or low suction pressure
Lubrication failure from low oil level, contamination, poor oil return, or pump faults causes noise, overheating, or low-oil-pressure trips
Valve, piston, screw, bearing, or internal wear reduces compression efficiency and appears as poor capacity or abnormal pressure balance
Condenser fouling or restricted cooling medium raises discharge pressure and temperature and may trigger high-pressure protection
Capacity-control, solenoid, sensor, motor, or protection faults cause unstable loading, short cycling, or failed starting

Service & Maintenance

Trend suction and discharge pressures and temperatures, oil level and condition, refrigerant condition, vibration, leakage, and compressor loading. Inspect cooling, filters or strainers, valves, safety devices, electrical protection, and control history; exact refrigerant charge, pressure limits, and internal clearances must follow manufacturer documentation.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

Replacement Parts

Keep approved seals and gaskets, filters or driers, oil-system parts, solenoid and control-valve items, sensors, motor or starter components, and manufacturer-recommended internal service parts.
Equipment Model #80602 · ✓ still in production