Library› Engine Room› Pumps› Fire Pump (Main + Emergency)› Taiko Kikai EVH 100/70

EVH 100/70

Fire Pump (Main + Emergency) · Pumps

Class-certified type (DNV register) · technical data sheet not yet verified​‌​‍⁠​⁠‌⁠‌​‌‍​⁠‍‌‍​⁠

Taiko Kikai Taiko EVH 100/70 — Pumps, fire.

Specifications

Technical data.reference — unverified

Do you have the manufacturer datasheet for this model? Send it with the enquiry form — we check it and name the source.

Pump Typecentrifugal
Flow Rate (m³/h)100
Head (m)70
Inspection

Inspector Detail

Common issues

  • Impeller wear or cavitation damage reducing capacity/head below the rated duty point
  • Mechanical seal leakage from dry-running events or seal face wear
  • Bearing wear or misalignment at the pump/driver coupling
  • Priming system faults on self-priming units, causing slow or failed priming
  • Casing or wear-ring corrosion from prolonged seawater service
  • Relief/pressure-control valve drift, allowing over- or under-pressure at the fire main

Inspection checklist

  • Run the annual capacity/pressure test at the required duty point per SOLAS (rated pressure with the required number of jets running)
  • Check mechanical seal for leakage during and after the test run
  • Check bearing temperature and vibration, and coupling alignment
  • Inspect suction strainer for fouling
  • Verify relief valve setting against the fire main's required pressure
  • Confirm remote/emergency start arrangement functions (including any fuel/battery readiness for an independently driven emergency pump)
  • Check isolation valves segregating the emergency pump's space from the space it protects, per SOLAS arrangement requirements

Service intervals

Annual capacity/pressure testannually, as required for SOLAS fire pumps
Mechanical seal inspection/renewalcondition-based; renew on leakage rather than a fixed calendar figure, typically within 1-3 years of continuous exposure
Bearing grease/renewalper maker's schedule, typically annually to every few years depending on running hours
Impeller/wear-ring clearance checkat overhaul or when capacity test results trend downward
Priming system service (self-priming units)annually or on any priming failure

Typical intervals for this design class, not the manufacturer’s figures for your model. The manufacturer’s manual is binding.

Typical wear limits

Impeller-to-casing/wear-ring clearancerenew wear rings once clearance opens beyond the maker's limit - figure varies by pump size, confirm against this model's manual
Shaft runout at the couplingre-align once runout exceeds the coupling maker's tolerance

Ranges are typical for this design class. Always confirm against the manufacturer documentation for your serial number.

Critical spares

  • Mechanical seal kit
  • Impeller
  • Wear rings
  • Shaft bearings
  • Coupling element
  • Priming pump/ejector components (if self-priming)

Safety

  • Never run the pump dry - seal damage and overheating are rapid and can itself become a fire/hot-surface hazard
  • Relief valve must be correctly set; an over-pressurised fire main risks hose/coupling failure under crew hands during firefighting
  • Emergency fire pump space isolation must be verified so a fire in the main machinery space cannot disable the emergency pump
  • Rotating shaft and coupling guards must be fitted before running
  • Diesel-driven emergency pump fuel supply and starting arrangement must remain independent and ready at all times

Class survey

SOLAS requires an annual capacity/pressure test of fire pumps at the rated duty point, and verification that the emergency fire pump and its space meet the required independence/isolation from the main machinery space. Class will want dated test records showing the achieved pressure and flow, not just a running confirmation.

Estimated lifetime: Not meaningfully expressed in running hours given intermittent duty; centrifugal fire pumps commonly remain in service 20+ years with periodic seal, bearing and impeller renewal

Need this part?

Request a quote for this model.

Free of charge — send us your request for Taiko Kikai equipment. Our team checks it and replies by e-mail.

For marine equipment hardly any maker or authorised dealer will name a price while the vessel is unknown. With the vessel details, availability and price can be settled faster; without them we may have to ask first, which costs a few days. If you are not allowed to name the vessel, a photo of the rating plate is enough — attach it below or send it as a reply to our confirmation e-mail.

Your contact details are not published. No account required.
Related models

Also in Fire Pump (Main + Emergency).

Other models of the same equipment type, Taiko Kikai first.

By manufacturer GrundfosKSBEbara MarineRuhrpumpenSulzerTaiko KikaiKawamotoCalpeda MarineHamworthy (Waertsila)FikeNaniwa PumpSEIMIShinkoAurora PumpDESMIAll manufacturersSpare parts by equipmentNew here? Create a free account Can't read the plate? Try the nameplate scanner All Taiko Kikai models More like Taiko EVH 100/70
More than the data sheet shows

We answer by e-mail, never with an automatic reply.

Tell us what you need for this Taiko Kikai EVH 100/70 — a part, a service call, a second opinion. Are you Taiko Kikai? Claim this brand page.

Service engineer? Write the day report for this EVH 100/70 in OceanSphere Work — photos, hours and parts, as a PDF for the owner. Try it free for 14 days →

Frequently asked

Questions that come up with this equipment.

Is this model's data free?

Yes. Specifications, documents and service notes for this model are readable without an account. An account adds saved searches and requests, nothing is taken away.

Can you find a part for this exact model?

Yes. Tell us the manufacturer, the model and what you need — a person reads every request and replies by e-mail.

The specifications look wrong — what now?

Send us the nameplate or the correct value. We check it against the manufacturer datasheet or class-society record and update the page.