Graviner

Mk6 12ch

Graviner Mk6 12ch is listed in this library as a marine oil-mist detection equipment in the Oil Mist Detection / Oil Mist Detector category. Equipment of this class is typically installed on or adjacent to the engine crankcase with sampling points or sensors connected to the monitored crankcase compartments. Its shipboard purpose is to detect abnormal oil-mist conditions that can indicate overheating and an increased risk of crankcase fire or explosion. The exact piping, electrical, control, foundation, and accessory arrangement depends on the vessel and the supplied configuration. No additional verified rating, capacity, weight, dimension, or operating limit is provided in the source entry. Where adjacent models in the same product family differ in rating, size, materials, control options, certification, or accessories, refer to the manufacturer documentation for the exact model-specific differences.

Components & Design

Component data being added…

Technical Data

detection method scattered light
alarm threshold mg l 2.0
channels 12
engine cylinders max 12

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Contaminated optics, sample paths, or sensor chambers from oil deposits cause drifting readings, false alarms, or failed self-tests
Blocked sampling pipe or ejector flow prevents representative crankcase atmosphere reaching the detector and can cause low or missing readings
Fan, pump, ejector, or flow-monitor faults reduce sample flow and trigger flow alarms
Electrical supply, processor, or communication failure can disable one or more channels or the complete monitor
Incorrect zeroing, calibration, or sensor replacement can cause inconsistent channel readings or nuisance alarms

Service & Maintenance

Inspect sampling pipes, drains, optics or sensing chambers, fans or ejectors, channel identification, alarm and shutdown interfaces, power supply, and self-test results. Cleaning, zeroing, and functional testing must follow the engine and detector manufacturer procedures.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

Replacement Parts

Carry approved filters, sampling-line seals, cleaning materials, fans or pumps where applicable, sensor or optical service components, fuses, and critical electronic modules recommended for the installed detector.
Equipment Model #70722 · ✓ still in production