Graviner

Mark 5 16ch

Graviner Mark 5 16ch is a crankcase oil-mist detection system. It is normally installed on a large diesel engine with sampling or detector points connected to crankcase compartments and an alarm/control unit. Its primary purpose is to warn of abnormal oil-mist formation that can precede a crankcase hot spot or explosion. Unlike ordinary temperature monitoring, oil-mist detection responds to aerosol concentration within the crankcase and is therefore sensitive to sampling cleanliness and optical condition. The supplied record already contains the available concise model or rating information, so those existing figures are not duplicated here and no additional meaning is inferred from the model code. For exact ratings, dimensions, settings, capacities, materials and variant-specific limits, refer to the manufacturer documentation for the exact figure.

Components & Design

Component data being added…

Technical Data

detection method scattered light
alarm threshold mg l 2.0
channels 16
engine cylinders max 16

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Contaminated detector optics or sampling passages cause false alarms, slow response or detector-fault indications
Blocked or leaking sample lines cause unequal sampling and unreliable compartment comparison
Fan, pump or suction faults on aspirating systems cause low-flow alarms or loss of monitoring
Sensor or electronics faults cause unstable baseline, repeated alarms or channel failure
Incorrect cleaning, calibration or reassembly after service causes persistent imbalance between channels

Service & Maintenance

Inspect sampling pipes, detector chamber, optics, filters, fan or pump where fitted, drain arrangements and alarm interfaces. Keep sample passages clean and investigate repeated channel deviations rather than simply resetting alarms. Function-test alarms under the approved procedure. Exact alarm levels and calibration methods require manufacturer and engine documentation.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

Replacement Parts

Carry filters, seals, cleaning materials, sampling-line fittings, fan or pump service parts, fuses and supported sensor or electronic modules.
Equipment Model #70744 · ✓ still in production