Alfa Laval

Aalborg JWP-25

Alfa Laval Freshwater Generators. Alfa Laval JWP freshwater generators are plate heat transfer evaporators for seawater desalination via vacuum distillation. The JWP series (single-stage) operates with titanium plate heat exchangers for evaporator and condenser, two-stage salt/air ejectors for vacuum maintenance (85–95%), demisters for salt droplet separation and integrated sa

Components & Design

Component data being added…

Technical Data

capacity t day 25
process vacuum distillation
energy source waste heat
salinity ppm out 2

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Plate scaling and corrosion (calcium carbonate, magnesium hydroxide, calcium sulfate deposits)

Every 6 months: visually inspect plate packages, soak with mild acid solution (e.g. Descalex), use soft brush for gentle cleaning, check for pinholes/cracks, monitor ring surface damage (pitting, scratches, erosion)

Gasket wear and sealing leaks (neoprene coating flaking, gasket damage)

Every 12 months: visually inspect gasket surface damage (wear, deformation, traces of salt crystallization), mark leak points during pressure test, replace worn gaskets, clean and dry seal surfaces before re-fastening

Ejector vacuum loss and air leaks (ejector nozzle wear, poor vacuum retention, seal wear)

Weekly check vacuum gauge (shall maintain 85–95%); if difficult: air pressure loss test (if vacuum drops >2% in 8 h = leak present). Remove inspection plug, inspect ejector throat with flashlight, remove deposits with scraper, ejector pump inlet pressure must be ≥3 bar

Demister contamination and salt carryover (demister blocked by salt deposit → high salinity)

Every 6 months: visually inspect demister element (blockages, salt build-up), test condenser for tube leaks (pressure test), at high salt content: chemically clean or replace condenser and demister. Monitor brine level via sight tube

Salinometer sensor contamination and incorrect quality measurement (salt content sensor contaminated, calibrated incorrectly, electrode deposits)

Daily: check salinometer reading (shall be <10 ppm); if measurement fault: clean sensor with dry brush, NEVER touch with bare hands, check electrodes for contamination, if necessary descale with solvent. Target: salt content of distillate <10 ppm

Hygiene and biofilm formation in pipelines/tank (legionella risk, microbial contamination during storage)

Every 3 months check tank water quality (microbial count); perform monthly CIP cleaning (cleaning-in-place), flush pipelines with biocide/chlorine, check tank cover for light ingress/contamination, maintain freshwater temperature ≥55°C to prevent legionella proliferation

Type-general inspection and maintenance points for this equipment category — not model-specific.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →
Equipment Model #69900 · ✓ still in production