Carrier

Carrier 42CE-08

Carrier Carrier 42CE-08 — Air Conditioning, marine air handling; source metadata also lists power 8.0 kW, capacity 4000 m³/h. The supplied category identifies the equipment as AHU (Air Handling Unit), and it is normally installed in an accommodation, machinery or technical HVAC space connected to ventilation ductwork and cooling, heating or refrigerant services as applicable. In that listed role, its primary purpose is to cool, heat, dehumidify, filter and circulate air for occupied or technical spaces. Self-contained AC units, AHUs and central-chiller interfaces differ in refrigeration and air-distribution arrangement, but all depend on clean heat-transfer surfaces and reliable airflow and controls. Within the supplied list, this variant is distinguished from neighbouring entries by its model designation and the explicitly listed power and capacity; further hardware differences are not stated in the source. No additional performance, approval or construction detail is inferred from the model code beyond the information supplied in the source record. For exact ratings, dimensions, settings, capacities, materials and variant-specific limits, refer to the manufacturer documentation for the exact figure.

8.0 kW
Power
4000 m³/h
Capacity

Components & Design

Component data being added…

Technical Data

unit type AHU
airflow 4000 m³/h
fan power kw 8

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Dirty filters, coils or air passages reduce airflow and cause poor temperature control or fan overload
Fan, motor, belt or bearing wear causes vibration, abnormal noise or reduced air circulation
Refrigerant or chilled-water leakage causes loss of cooling capacity and long running periods
Condensate drain blockage causes water leakage, corrosion or microbial growth
Sensor, thermostat, valve or control faults cause unstable temperature, icing or repeated protective trips

Service & Maintenance

Inspect filters, fans, bearings, belts or couplings, coils, refrigerant or water connections, condensate drains and controls. Clean heat-transfer surfaces and drains and check for corrosion, leakage and abnormal vibration. Verify temperature and airflow control using the approved system settings. Refer to the manufacturer documentation for the exact figure for refrigerant charge, airflow, pressure and control limits.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

Replacement Parts

Carry filters, belts, fan bearings or motors, temperature sensors, condensate parts, refrigeration valve or seal items, fuses and control relays.
Equipment Model #68529 · ✓ still in production