Common failures & inspection points

Absorber/venturi erosion and wear

Six-monthly visual inspection of absorber for signs of erosion and corrosion; pressure test of spray headers (low pressure = erosion); inspection for wear on venturi walls and deflector plates

Spray nozzle plugging and erosion

Weekly inspection of spray headers and header on plugging or erosion; inspection of liquid pressure gauges to detect abnormally low pressures (indicator of erosion); six-monthly internal inspections for plugged or eroded nozzles

Effluent sensor and pH probe calibration

Annual full service and calibration of all sensors by certified technicians; regular inspection for probe fouling and sensor sensitivity; calibrate CEMS and water monitoring systems per manufacturer specifications

Abwasserqualität: pH, PAH, Trübung, Temperatur Monitoring

Continuous monitoring of inlet and outlet water quality; documentation of pH (min. 6.5), PAH, turbidity, temperature (max. 60°C); annual sampling to be performed no later than after first year of operation; 3-year retention of all test results

Corrosion on effluent pipes and discharge lines

Wall thickness measurements of all effluent pipes and overboard lines at every annual class survey (DNV requirement); visual inspections for signs of corrosion and erosion; inspection of integrity of pipe supports and welds; particular attention to acid corrosion prior to seawater dilution

Mist eliminator fouling and blockage

Six-monthly internal inspections of mist eliminator for fouling, plugging and corrosion; inspection for solids accumulation in eliminator; functional test of eliminator washdown systems; cleaning or replacement when damaged

Type-general inspection and maintenance points for this equipment category — not model-specific.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →
Equipment Model #44391 · ✓ still in production