OceanSphereENGINES
Library› Engine Room› Exhaust Gas Cleaning› SOx Scrubber› Wärtsilä Moss WM385-HS installed onboard MEIN SCHIFF 5 (IMO 9753193)

WM385-HS installed onboard MEIN SCHIFF 5 (IMO 9753193)

SOx Scrubber · Exhaust Gas Cleaning

Class-certified type (DNV register) · technical data sheet not yet verified​​‍‍‍⁠‌‌⁠‍⁠‌​​‌⁠⁠​​⁠

WM385-HS installed onboard MEIN SCHIFF 5 (IMO 9753193) by Wärtsilä Moss AS. DNV MED certificate MEDG000004U.

Specifications

Technical data.

Every value below comes from the manufacturer datasheet or class-society record on file for this model.

IMO ApprovedYes
📄
Download datasheet (PDF) (1339 KB)
Inspection

Inspector Detail

Common issues

  • Wash water pH excursions outside permitted discharge limits due to caustic dosing system faults
  • Scrubber tower packing or spray nozzle fouling with soot/particulate reducing SOx removal efficiency
  • Exhaust gas bypass/damper actuator sticking, risking incorrect flow routing
  • Wash water circulation pump cavitation or seal wear from abrasive particulate content
  • CEMS sensor drift or fouling giving unreliable SO2/CO2 ratio readings
  • Corrosion of scrubber tower internals and ducting from acidic wash water, especially in open-loop operation
  • Open/closed loop changeover valve or control logic faults in hybrid mode
  • Residue/sludge holding tank overfilling in closed-loop mode due to separator underperformance

Inspection checklist

  • Verify CEMS calibration certificate and function against reference gas
  • Check wash water pH and turbidity readings against the IMO 2015 EGCS Guidelines (MEPC.259(68)) thresholds
  • Inspect scrubber tower internals for scale, soot deposits and corrosion at manholes
  • Check spray nozzles for blockage/wear during tower opening
  • Inspect wash water circulation pumps for seal leakage and vibration
  • Verify caustic dosing system function and tank level
  • Check bypass damper operation and position indication
  • Confirm the exhaust gas cleaning system record book entries are current
  • Inspect ducting and expansion joints for corrosion and leaks
  • Verify residue/sludge tank level alarms and discharge records for closed-loop mode

Service intervals

CEMS calibrationper maker/class requirement, typically every 3 months plus an annual full calibration - confirm against maker manual
Wash water pump seal inspectionannually or at first sign of leakage
Scrubber tower internal inspectionannually, with a fuller internal check at dry-docking opportunity
Caustic dosing system checkquarterly
pH/turbidity sensor cleaningmonthly or per observed fouling rate

Typical intervals for this design class, not the manufacturer’s figures for your model. The manufacturer’s manual is binding.

Critical spares

  • Wash water circulation pump seal kit
  • Spray nozzle set
  • pH and turbidity sensor probes
  • Bypass damper actuator
  • CEMS sample line filters and reference gas bottles
  • Caustic dosing pump diaphragm/seal kit

Safety

  • Caustic soda handling in the dosing system - chemical burn risk, requires PPE and eyewash station access
  • Acidic wash water in open-loop mode - corrosive contact hazard during inspection
  • Confined space entry for scrubber tower internal inspection - follow enclosed space procedure and confirm gas-free
  • Hot exhaust ducting and tower surfaces - burn hazard
  • SO2 exposure risk if sampling lines or the CEMS enclosure are opened without isolation

Class survey

Class reviews the EGCS Onboard Monitoring Manual, wash water discharge records, CEMS calibration certificates and the SOx compliance/deviation log against MEPC.259(68); confirm current survey scope against the vessel's EGCS approval certificate.

Need this part?

Request a quote for this model.

Free of charge — send us your request for Wärtsilä Moss equipment. Our team checks it and replies by e-mail.

For marine equipment hardly any maker or authorised dealer will name a price while the vessel is unknown. With the vessel details, availability and price can be settled faster; without them we may have to ask first, which costs a few days. If you are not allowed to name the vessel, a photo of the rating plate is enough — attach it below or send it as a reply to our confirmation e-mail.

Your contact details are not published. No account required.
Related models

Also in SOx Scrubber.

Other models of the same equipment type, Wärtsilä Moss first.

By manufacturer Wärtsilä MossYara MarineEcoSprayME ProductionLangh TechHyundai Heavy Industries Power SystemsPanasiaZHEJIANG ENERGY MARINE ENVIRONMENTAL TECHNOLOGY CO.,LTDAndritz MarineHI AIR KOREA Co., Ltd.Alfa LavalPacific Green MarineCR OceanMitsubishi Heavy IndustriesClean Marine ASAll manufacturersSpare parts by equipmentNew here? Create a free account Can't read the plate? Try the nameplate scanner All Wärtsilä Moss models More like WM385-HS installed onboard MEIN SCHIFF 5 (IMO 9753193)
More than the data sheet shows

We answer by e-mail, never with an automatic reply.

Tell us what you need for this Wärtsilä Moss WM385-HS installed onboard MEIN SCHIFF 5 (IMO 9753193) — a part, a service call, a second opinion. Are you Wärtsilä Moss? Claim this brand page.

Service engineer? Write the day report for this WM385-HS installed onboard MEIN SCHIFF 5 (IMO 9753193) in OceanSphere Work — photos, hours and parts, as a PDF for the owner. Try it free for 14 days →

Frequently asked

Questions that come up with this equipment.

Is this model's data free?

Yes. Specifications, documents and service notes for this model are readable without an account. An account adds saved searches and requests, nothing is taken away.

Can you find a part for this exact model?

Yes. Tell us the manufacturer, the model and what you need — a person reads every request and replies by e-mail.

The specifications look wrong — what now?

Send us the nameplate or the correct value. We check it against the manufacturer datasheet or class-society record and update the page.