Certificate MEDD00000Z2
Certificate MEDD00000Z2 by VIKING Life-Saving Equipment Norway AS. DNV MED certificate MEDD00000Z2.
Inspector Detail
▸
Common issues
- Hard starting after extended lay-up from fuel system varnishing
- Starter battery degradation from infrequent test runs
- Release hook or hydrostatic interlock corrosion from saltwater exposure
- Davit falls wire corrosion, kinking or under-lubrication
- Air supply system filter contamination on enclosed variants
- Canopy/hull gelcoat cracking and UV degradation over time
Inspection checklist
- Weekly engine start and minimum 3-minute run with cooling/exhaust check
- Monthly dry test of the on-load release gear
- Monthly battery and charging circuit check
- Quarterly falls wire inspection for broken strands and corrosion
- Annual winch brake function and holding test
- Annual hook/interlock overhaul per maker instructions
- 5-yearly on-load release gear load test per MSC.1/Circ.1206/Rev.1
- Bilge pump and self-bailing arrangement check
Service intervals
| Engine test run | weekly, minimum 3 minutes under load |
| On-load release gear test | annual dry test; 5-yearly load test per SOLAS |
| Falls wire inspection and lubrication | every 3 months |
| Winch brake overhaul | annual or per maker schedule |
| Battery renewal | typically every 2-4 years |
| Hook/interlock mechanism overhaul | annual, per davit maker instructions |
Typical wear limits
| Falls wire rope diameter loss | condemn per the wire rope maker's table, commonly around 10% diameter reduction - confirm against SOLAS/maker limits |
| Release hook jaw wear | renew when wear exceeds the maker's stated limit - confirm against the maker manual, no generic figure should be assumed |
Ranges are typical for this design class. Always confirm against the manufacturer documentation for your serial number.
Critical spares
- Fuel injector / injector nozzle set
- Starter battery
- Release hook and hydrostatic interlock overhaul kit
- Falls wire (davit wire rope)
- Raw water pump impeller
- Hatch/canopy seal gasket set
Safety
- Uncontrolled or premature release during launch drills - strict permit-to-work procedure required
- Crush/impact injury during freefall launch testing - maintain an exclusion zone
- Heat and fume build-up inside an enclosed boat during engine test runs
- Fall-from-height risk during davit and falls inspection
Class survey
Falls under SOLAS Ch. III / LSA Code. Annual thorough examination and 5-yearly operational load test of the on-load release gear (MSC.1/Circ.1206/Rev.1) are typically required; class expects dated maintenance and release-gear test records retained on board.
Components & Design
Component data being added…
Technical Data
🤖 Ask about this model
One free question — answered like a marine engineer. No account needed.
Suppliers & Spare Parts
Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.
📄 Request sourcing links & documentsCases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.
Start free trial →Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.
Maritime Network →DNV type approval
Verified against the DNV Approval Finder — the certificate below is issued by DNV, not by us.
- Certificate
- MEDD00000Z2
- Certificate holder
- VIKING Life-Saving Equipment Norway AS (Norway)
- Valid until
- 2026-12-28